You are on page 1of 15

SAG TENSION

CALCULATION

Sensitivity: LNT Construction Internal Use


Sag Tension Calculation

TABLE OF CONTENT

1. SUBSTATION ENGINEERING AND DESIGN - HOME PAGE……………………………3

2. CALCULATION CONSOLE……………………………………………………..………….….….3

2.1 Project Selection…………………………………………………….……….….….3

2.2 Copy Project / System ……………………………………..…....……………..…….........4

3. PROJECT PARAMETERS…..……………………………………………..…………………..…..5

4. DOCUMENT PARAMETERS …………………….…………………..………………….…...….6

5. FEEDER BAY CONFIGURATION……………….....………….……….…….....................….7

6. SAG TENSION CALCULATION INPUTS…….……...................................................….9

6.1. Sag Tension Calculation – Main Conductor Inputs…………………..…..…….…….10

6.2. Sag Tension Calculation – Shield Wire Inputs …………………………………..…….11

7. SAG TENSION CALCULATION OUTPUT…...........................................................….12

8. STRINGING CHART CALCULATION…….……...........................................................13

9. DOCUMENT CREATION……………………………….……….…..................................…14

2|Page

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

1. SUBSTATION ENGINEERING AND DESIGN - HOME PAGE

Select Sag Tension Calculation


to perform the calculation

2. CALCULATION CONSOLE

2.1 Project Selection

If you want to go to the


STEP1: Please select the Menu Page, Please click this
project button
STEP2: Please select the If you want to clear the
system STEP3: Click Go project, please click this
button

3|Page

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

2.2 Copy Project / System

If this current project has the same details as


some previous existing project, Please Click the
Copy Project / System.

STEP1: Please select the


required Source Project.

STEP3: Click the Copy button if the


current project requires copy of the
STEP2: Please select the
previous project.
required Source System.

4|Page

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

3. PROJECT PARAMETERS

Please select “Project Level


Parameters”

STEP 1: Please choose the


STEP 2: Please fill all mandatory
Climatic Condition
fields

All mandatory fields are


marked with *

STEP3: Click on “Save” to


Save the Details

5|Page

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

Please select “System


Parameters”

4. DOCUMENT PARAMETERS

Please select “Document


Parameters”

Click this button to go to


Calculation Console Page

6|Page

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

STEP 1: Please fill all mandatory


fields

STEP2: Choose the Language

STEP3: Choose whether and


Page Numbering is
Required or not.

STEP4: Click on “Save” to


Save the Details

5. FEEDER BAY CONFIGURATION

Please select “Feeder Bay


Configuration”

7|Page

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

Edit/Delete options can be


used to edit/delete details

Click on “Add New”


Please enter Feeder/ Bay
Name and SLD Reference

Please select “Input /


Output Console”

8|Page

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

6. SAG TENSION CALCULATION INPUTS

Please click on “Input” to


provide the inputs for Main
Conductor and Shield Wire

9|Page

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

6.1. Sag Tension Calculation – Main Conductor Inputs

Please fill all


mandatory fields

Please select the condition –


Equal / Non Equal

All mandatory fields are


marked with *

New conductors can be added


in General Masters -> Overhead
Conductors

Additional parameter details can be


edited only in General Masters ->
Overhead Conductors

Please click this button to


view the output

10 | P a g e

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

6.2. Sag Tension Calculation – Shield Wire Inputs

Please select the condition –


Equal / Non Equal

Please fill all


mandatory fields

All mandatory fields are


marked with *

New conductors can be added


in General Masters -> Overhead
Conductors

Additional parameter details can be


edited only in General Masters ->
If any notes is required, Overhead Conductors
please enter here

Arrows can be moved up / down


according to required order of
Temperature in Sag Tension
table in the output.

Please click this button to


view the output

11 | P a g e

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

7.SAG TENSION CALCULATION OUTPUT

Click to provide Stringing Click to view the


Chart Inputs if necessary PDF File.

After checking the Calculation output,


If you want to go to the Previous
Please freeze the calculation so that
Page, click this button
document creation can be performed.

12 | P a g e

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

8. STRINGING CHART CALCULATION

Please enter the Wind


Percentage Inputs for the
Temperature and click
“Calculate”

Click to view the


PDF File.

13 | P a g e

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

9. DOCUMENT CREATION

Please Enter the


Revision Code and
Document Date
Enter the document index and please
click “Add to Document “

14 | P a g e

Sensitivity: LNT
L&T Construction Internal Use
Sag Tension Calculation

Step1: Please Enter Document index and


Annexure name If any annexures
has to be added in
between the
calculation, it can
be added in Other
Step2: Please upload the File Attachments
section

Click on “download” to get the complete


generated pdf document

Please enter the remarks for next revision and click


on “Submit” to enter the next revision.

15 | P a g e

Sensitivity: LNT
L&T Construction Internal Use