You are on page 1of 1

CANOPY

ROLLING SHUTTER W1 W1

GUARD ROOM
2800 X 3780
W1

W1
LEGEND -

OFFICE SPACE
5100 X 3120
FSL FULL SUPPLY LEVEL
MWL MAXIMUM WATER LEVEL

508
MDDL MINIMUM DRAWDOWN LEVEL

2200 X 3780
508

TOILET
W1
NGL NATURAL GROUND LEVEL

V1
FGL FINISHED GROUND LEVEL

B
864

V1
PS PIPE SUPPORT
PW PARTITION WALL

5250
VT VERTICAL TURBINE PUMP
GATE HOISTPLATFORM

CBL CANAL BED LEVEL

W1

1034
864
RB ROOF BEAM
ING
PC C LIN
HICK TB TIE BEAM
mT
50m

500
SW SIDE WALL
1034
X

762 TR TRASH RACK

X
A CBL:+239.515

GR GUIDE RAIL
DETAILS OF PUMP PLATE

MAINTENANCE
W1

BAY
SALIENT FEATURES OF BERKHEDA IRRIGATION PROJECT
1:5.67 Slope
1.LSL -240.00
PIPE
1000

2000

2.LSL/MDDL -240.00
FORE BAY 5.BARREL INVERT RL (AT PH) -239.515
6.FLOOR RL OF PUMP HOUSE -242.515
7.DESIGN DISCHARGE -1.92 CUMEC
8.POWER REQUIREMENT - 1.30 MW

W1
MAIN CANAL/BARREL

450
TRASH RACK
TRASH RACK
A

TRASH RACK
GATE (1MX1.9M)

NOTE :-
50m
mT
HIC
1. ALL DIMENSIONS ARE IN MM EXCEPT ELEVATION IN M
KP 2. FOLLOW WRITTEN DIMENSIONS DO NOT SCALE
CC
LIN
ING 3. FOUNDATION DEPTH WILL BE AS SOIL REPORT OR UP
TO FIRM GROUND WHICH EVER IS MORE

W1
4. SPECIFICATIONS OF THE TENDER DOCUMENT WILL
BE FOLLOWED IN GENERAL.
2500
5. STRUCTURAL DIMENSIONS SHOWN ARE INDICATIVE
W1 W1 W1 W1 W1
MAY CHANGE AS PER ACTUAL DESIGN.
6. THE GENERAL ARRANGEMENT HAS BEEN FREEZED
CONSIDERING THE STANDARD DIMENSIONS AND THE

ROLLING SHUTTER
B

W1
SPACE PROVIDED IS ON SAFER SIDE FOR INSTALLATION OF PUMPS
7. THE DRAWING SUBMITTED IS FOR FINALIZATION OF OVER
ALL SIZE OF THE PUMP HOUSE.
8. SLOPE IS REPRESENTED IN V:H FORMAT
9. THE HYDRAULIC & PUMP DIMENSIONS CONFER TO THE SPECIFICATIONS
W1
MENTIONED IN TECHNICAL DATA SHEET OF XYLEM WATER SOLUTIONS

ELECTRICAL
PVT. LTD

BAY
PROVIDED BY CONTRACTOR & H.I.S
10. THE DISTANCE OF ELECTRIC ROOM IS TENTATIVE & SHALL BE
FINALISED
W1

AFTER CONSULTATION WITH PUMP VENDOR


11. GROUND PROFILE IS TENTATIVE, DETAILED SURVEY IS NEEDED FOR
ACCURATE
DEPICTION OF PROFILE
W1

ROLLING SHUTTER W1 W1 W1 W1 W1 W1

CANOPY

PLAN OF PUMP HOUSE @ 242.60 LEV.

+250.60M SELF SUPPORTED


ROOFING

GOVT. OF MADHYA PRADESH


GL GL
WATER RESOURCES DEPARTMENT
1.5 :1 BARKHEDA MEDIUM IRRIGATION PROJECT
:1
FSL -241.515 1.5
INTERMEDIATE
3.0
LVL+246.60M Title: BARKHEDA MEDIUM IRRIGATION PROJECT GAD OF PUMP HOUSE

HR :1
Dwg. No.-:BARKHEDA PH/GAD/ 01

0.25
0.25
HR
:1
Prepared by : Checked by : Checked by :
CBL+239.515

PUMP

GATE LIFTING ASSEMBLY


TYPICAL SECTION A-A OF
Vindhya Telelinks Ltd A.K. AHIRWAR
FL./PLINTH LVL.
+242.60M APPROACH CHANNEL SUB ENGINEER
2nd Floor, Wing-B Commercial Plaza, URIBAG WRSD.
FI LE Radisson Hotel NH-8, Mahipalpur New Delhi VTL-PCIPL JV KUKSHI DISST. DHAR (M.P)
ND PRO GL GL
L GROU (RL+242.40m) FSL.+241.60M
NATURA 1 Checked by : Checked by : Submitted by :
1:
1:

INSPECTION RAMP

643.0
1

FSL -241.515
2500
GL.
+240.30M
0.25

(RL+241.515m)

0.25:1
GR

HR
HR

MDDL LWL.
:1

APPROACH
+239.50M
50 mm thick PCC Lining
B.S. SANKAT
GATE(1.9m x 1m)
1:5.67
Slope SHIVAM JOHARI YOGESH BIRLA
FROM BARREL
(2mx2.5m) CBL +236.785 SUB DIVISIONAL OFFICER SUB DIVISIONAL OFFICER EXECUTIVE ENGINEER
/ CANAL TR
FORE BAY WRSD. GANDHWANI URIBAG WRSD. WATER RESOURCES DIVISION
(RL+239.515m) DISST. DHAR (M.P) KUKSHI DISST. DHAR (M.P) MANAWAR DISST. DHAR (M.P)
TYPICAL SECTION B-B OF APPROACH Recommended by : Approved by :
50mm THIC
K PCC LININ
G
CHANNEL AT FORE-BAY
+236.50

+236.10M

P.JOSHI Y.C. SHARMA


SUPERINTENDING ENGINEER CHIEF ENGINEER
SECTION A-A WATER RESOURCES CIRCLE, DHAR (M.P) NARMADA-TAPTI BASIN WRD INDORE (M.P)

SCALE - NTS (A1)

You might also like