UMTH12 - Rev.1 - 17/04/2018
index
1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.0
2
UMTH12 - Rev.1 - 17/04/2018
1.0 INTRODUCTION
This manual gives all the necessary information for a proper use of HC CRYO
TSHOCK unit, APHRODITE. This device is not a medical device HC CRYO T-SHOCK
offers a practical innovation; is an almost exclusive product.
On year 2014, HC CRYO T-SHOCK has been awarded by an international jury at
the Gicare Exhibition in Paris for the most innovative device both in terms of techno-
logy and application. Cold and heat exchanges are obtained thanks to a solid state
system, which allows us to use a quite compact device. There is no use of gas, ice,
liquid. Temperatures and fast exchange between heat and cold make HC CRYO
TSHOCK a special device.
HC CRYO T-SHOCK is provided with wide coloured graphic display. A very simple
software is allowing the operators to use some pre-set programs and also to operate
manually by setting all parameters. Software is using Windows CE platform for gran-
ting versatility and up-grading. Free memory allows the most expert operators to store
several customised programs. All functions are automatically checked while the main
switch is turned on and are continuously monitored during application.
2.0 INSTALLATION
Before apply the unit to your Clients, we suggest to switch the unit on and carry out
a safety test and a working test, in order to check the integrity of the unit after the car-
riage.
Read the all this manual and all further annexed information.
WARNING!
Any application must be carried out on CONSCIOUS people. Furthermore, pay always
attention to the client’s feeling during application. Adjust temperature with reference to the
feedback of each person.
3
UMTH12 - Rev.1 - 17/04/2018
Desktop device
Device on trolley
4
UMTH12 - Rev.1 - 17/04/2018
The second one is granting electronic signals between desk-top device and trolley.
Take the metal connector coming from the top of the trolley and push it into the socket
placed on the bottom of the desk-top device, by screwing it for assuring it.
Two screws are available under the top of the trolley. While
the desk-top device has been placed over the trolley, use the
two screws for fixing it.
5
UMTH12 - Rev.1 - 17/04/2018
FEMALE
MALE
Place the hand-piece in a stable position over the relevant holder on the left side of
the unit.
6
UMTH12 - Rev.1 - 17/04/2018
6.0 SWITCHING ON
Press on/off switch placed on the back of the unit
7
UMTH12 - Rev.1 - 17/04/2018
If you wish to start the program without changing the parameters, press the button ►
otherwise turn the knob and you can select the desired parameter. After selecting the
8
UMTH12 - Rev.1 - 17/04/2018
The parameters marked by using the padlock symbol on the left, as pictured below,
can not be modified
At the end of application time, the device shall generate an acoustic signal and the
following message may appear.
Press to exit.
9
UMTH12 - Rev.1 - 17/04/2018
The following screen shall appear with two icons, the first one concerning programs
and the second one concerning memories. Use the knob for selecting "programs"
and press .
10
UMTH12 - Rev.1 - 17/04/2018
Knob
To select the desired part of the body turn the knob and press
11
UMTH12 - Rev.1 - 17/04/2018
Should you select a program made by more than one single step, the following screen
shall appear:
To have a look at the parameters for a special step it’s necessary to scroll through the
step by pressing F1 and F2 keys. If you wish to change the value of a parameter select
the parameter by turning the knob and then press the - and + buttons.
Press d for starting application.
The following screen shall appear:
12
UMTH12 - Rev.1 - 17/04/2018
13
UMTH12 - Rev.1 - 17/04/2018
The following screen shall appear with 3 icons, the first one concerning programs, the
second one concerning memories and third one concerning target.
14
UMTH12 - Rev.1 - 17/04/2018
the following screen shall appear
Downloaded from www.Manualslib.com manuals search engine
CRYO T-SHOCK USER MANUAL
15
UMTH12 - Rev.1 - 17/04/2018
Choose each word by turning the knob; to select adjacent space pressing key + and
-. Press to save and to esc without saving.
Press F2
The following screen shall appear:
16
UMTH12 - Rev.1 - 17/04/2018
Use the knob for choosing the second icon "MEMORY" and press , the following
screen appears
If multiple memories are present turn the knob to select the desired one, and press
17
UMTH12 - Rev.1 - 17/04/2018
18
UMTH12 - Rev.1 - 17/04/2018
19
UMTH12 - Rev.1 - 17/04/2018
1.0 INTRODUCTION
This is a device based on the technology of Péltier cells, with two components:
● Diathermy, capable of generating heat;
Coupling System for reducing radiating area at 29 mm large for facial applications
● Highest performances thanks to real-time temperature control with sensor attesting
skin’s temperature
● Standard accessories: main unit, hand-piece with detachable connector, 29 mm
adapter for treating small parts and doing facial applications, power cord with “shuc-
ko” plug, cryo-gel 1 Kg, operating manual
The three effects (hyperthermia, hypothermia and thermal shock) can be modulated in
depth and intensity.
● Automatic adjustment (feedback system) of the energy administered in relation to
target temperature
● Use of temperature
● Localised system
● No operating costs
The new CRYO T-SHOCK system allows adjusting the operating temperature of the
applicator from -18°C to 41 °C.
The cold produced by the Peltier cell is applied on the client’s body and a temperature
sensor measures the body temperature viewing it on the display to allow the operator
to immediately control the temperature change on the treated person.
The risk of freezing the treated area is a remote possibility, but there is a risk of an
ice burn if not used correctly.
21
UMTH12 - Rev.1 - 17/04/2018
primarily involve necrotic cell death by damaging fat with heat, high-intensity focused
ultrasound, or chemical injections.
Each approach poses potential technical challenges, particularly with respect to tar-
geting the right tissue depth and unintended damage to other structures close to or
within the fat layer. Predictability of efficacy using these other techniques is also uncer-
tain.
In contrast, the Cool-Sculpting procedure using Cryolipolysis induces apoptosis only
in fat cells to gently and gradually reduce the fat layer while preserving all other tissue
The result of this therapy is a reduction in cellulite and a more wholesome appearan-
ce.
Individuals are not all the time aware of what to anticipate when going by means of
a Cryo cellulite treatment. There are a couple of basic points that must be understood.
22
UMTH12 - Rev.1 - 17/04/2018
This will smooth out facial lines, reduce blemishes, wrinkles and makes tighter appea-
rance within few minutes. A full set of applications (from 4 to 8) will naturally begin
to renew production of collagen. Consequently, the result of a course of treatments is
a long lasting return of a more youthful, clear and youngest skin.
- Appearance of wrinkles and fine lines shall be highly reduced.
· Production of collagen resulting in fuller, more youthful and beautiful rejuvenated
skin.
- Puffiness around the eyes shall be significantly reduced or totally eliminated.
· Pores on the face and neck shall be reduced in size, limiting the intake of toxins, dirt
and grime.
- Benefits over lymphatic system, flushing away built up toxins, soothe inflammation
and irritation, removing puffiness, and redness.
· Skin conditions like Dermatitis, Eczema, Acne and Psoriasis could be reduced.
· Metabolic rate increases, Endorphin levels shall be stimulated.
After one session you can clearly see the reduction of lines, puffiness and clearing of
skin colour. Cryo Face-Lifts safely performed with high benefits and without any spe-
cial collateral effects and contra-contraindications by using not so hard temperature
for respecting comfort of each client without any limit into the age. This modality is
executed using high technological solutions belonging to HC CRYO T-SHOCK a new
and innovative device, using gas and liquid free system, handling from the operator
who can follow step by step all evolution of treatment.
23
UMTH12 - Rev.1 - 17/04/2018
TARGET
Body part Woman Body part Woman
Medium Medium
3 min 39°C 1 min 37°C
30 min - 2°C 20 min 4°C
3 min 39°C
Large
Large 2 min 37°C
3 min 39°C 20 min 4°C
30 min - 3°C
3 min 39°C XLarge
2 min 37°C
XLarge
24
UMTH12 - Rev.1 - 17/04/2018
WOMAN PROGRAMS
Face/Neck Face-lifts
2 min 37°C Nettoyage/Cleaning
8 min 6°C - 2°C 15 min
1 min 37°C
Cuperose
Anti-aging 8 min 5°
Anti-aging
1 min 37° Décolleté Décolleté
6 min 4° 2 min 36°
1 min 37° 12 min 4°C
25
UMTH12 - Rev.1 - 17/04/2018
WOMAN PROGRAMS
Body part Programs Body part Programs
Drainage Drainage
5 min 38°C 5 min 38°C
5° min 7°C 5 min 7°C
5 min 39°C 5 min 39°C
5 min 5°C 5 min 5°C
5 min 39 5 min 39
Slimming Slimming
5 min 39 5 min 39
20 min 0°C 30 min 0°C
5 min 39°C 5 min 39°C
26
UMTH12 - Rev.1 - 17/04/2018
27
UMTH12 - Rev.1 - 17/04/2018
28
UMTH12 - Rev.1 - 17/04/2018
MAN PROGRAMS
29
UMTH12 - Rev.1 - 17/04/2018
Chest Firming
5 min 4°C
1 min 37°C
5 min 4°C
30
UMTH12 - Rev.1 - 17/04/2018
31
UMTH12 - Rev.1 - 17/04/2018
32
UMTH12 - Rev.1 - 17/04/2018
Sculping application
Fat removal
33
UMTH12 - Rev.1 - 17/04/2018
34
UMTH12 - Rev.1 - 17/04/2018
35
UMTH12 - Rev.1 - 17/04/2018
36
UMTH12 - Rev.1 - 17/04/2018
1.0 INTRODUCTION
Tests we do before supplying each unit are essential pre-requisites for meeting all safe-
ty conditions coming from the laws in force as far as electro-medical equipment are
taken into consideration (Cfr. par. 9).
However, don't forget that according laws in force, reliability and the efficiency of an
electro-medical unit can be guaranteed only if:
l Installation, new settings and repairs are carried out only by the manufacturer or
PAGANI’s authorised technical staff;
l The electrical installation in the treatment room complies with the laws force;
l The unit is used in accordance with the operating instructions;
l Only original accessories are used.
All the units have to be kept in good conditions by regularly checking them and doing
the necessary repairs. This preventive maintenance should avoid possible break-
downs and guarantee:
l A correct functioning;
l Safety of both client and the user, as well as of the room in which the treatment is
performed;
l The best performance of the unit.
Preventive maintenance must be made by the operator, whereas the periodic controls
and repairs must be carried out by the Technical Assistance Service (T.A.S.). If no
regularly verification, including leakage currents testing has been made, PAGANI
decline all responsibility.
WARNING
Use of alcool is forbidden
37
UMTH12 - Rev.1 - 17/04/2018
WARNING
A whole electric security test must be carried out after any repair of the unit.
The symbol of the crossed box present on the equipment or in visible way on the con-
fection of the same one, indicates that the equipment is on the market after 13 August
2005 and that must be object of separate disposal.
In the case of irregular disposal of such refusals, the customer will be object of endor-
sements.
In the table written here below, some indications for the disposal of the unit and all
its parts are given. However, we suggest referring to the laws in force in your Country.
38
UMTH12 - Rev.1 - 17/04/2018
WARNING
The operator is advised against using the pressure therapy in case of pregnant women, can-
cers in the treatment area. Before treating clients with implanted heart pacemakers or with
cochlea transplant, consult a specialist.
Before treating clients with lower limb ischemia, cardiovascular disease consult a physician.
39
UMTH12 - Rev.1 - 17/04/2018
WARNING
All applications must be carried out on conscious patients, only. Furthermore always pay
attention to the patient’s feeling while the output energy is increasing.
If you have any question, not sufficiently dealt in this handbook, please do not hesitate
to consult Elettronica Pagani or your authorised dealer.
The end-user is recommended to keep a list of its unit, to conserve scrupulously the
operating manual, and to schedule an organic maintenance programme for all the
units.
The unit must be used exclusively by persons who, thanks to their professional forma-
tion and their experience, may offer the guarantee of a proper use and have been
trained; in particular the unit should be used by a doctor or under the responsibility
of a doctor.
WARNING
In case of a serious accident, please inform Elettronica Pagani immediately.
7.0 WARRANTY
Guarantee is covering all the defects of materials and workmanship for twelve month
for the applicators and two years for the other parts, starting from the purchase date,
if not differently agreed.
If the unit doesn’t work properly during the warranty, Elettronica Pagani would repair
it without any charges for the customer; in fact, guarantee includes the cost of spare
parts and labour, expect for the following conditions:
l Guarantee is valid only if the identification data (model, mark and technical featu-
res, etc) are available.
l Elettronica Pagani will repair only breakdowns. Costs and risks during removal,
transport and installation aren't covered by the guarantee.
l Elettronica Pagani or technical assistance centres authorised by Elettronica Pagani
do all repairs as per the a/m conditions. If non-authorised personnel carry out repairs,
guarantee is automatically invalid.
l Guarantee does not cover periodic checks, calibrations, maintenance and modifi-
cations, disposable and consumable parts and accessories.
l Guarantee is not valid when:
- damages have been caused by accidents, no correct uses, modifications, and use
of non-original spare parts and/or accessories;
- cables, electrodes and any other accessory subject to deterioration.
l Elettronica Pagani reserves the right to introduce changes or improvements without
being obliged to modify the units manufactured before.
40
UMTH12 - Rev.1 - 17/04/2018
- Temperature
working: from 15°C to 35°C (from 50°F to 95°F)
storage : from 0°C to 45°C (from 32°F to 113°F)
- Humidity
working: from 45% to 75% RH (not condensed)
storage: from 20% to 80% RH (not condensed)
- Pressure
working: from 860hPa to 1060hPa
(from 0.860bar to 1.060bar)
storage : from 860hPa to 1060hPa
(from 0.860bar to 1.060bar)
Simbol Meaning
Warning! Refer to instruction
manual/booklet (Table D 2 - Sign 10).
Device with Applied Part type B
(Table D 1 - Sign 19)
Alternating current
(Table D 1 - Sign 1)
ON (power)
(Table D 1 - Sign 12)
OFF (power)
(Table D 1 - Sign 13)
41
UMTH12 - Rev.1 - 17/04/2018
42
UMTH12 - Rev.1 - 17/04/2018