ABB RS232 wiring standards
Signal/pin primer
Note: This is NOT the same as the DB25 Parallel port on a PC.
8-5-07 Page 2
ABB RS232 wiring standards
RS232 on RJ45 (RS-232D)
More properly EIA/TIA - 561. Use when connecting to or from a serial port with a 8
position Modular Jack (RJ45). If you are cross-connecting from a DB9 or a DB25 use
the signal names to cross connect the appropriate connections.
Signal/pin primer
Note: Pin 1 is a multi-function pin sharing with DSR (Data Set Ready) and RI (Ring
Indicator). This means it is impossible to differentiate between a incoming ring signal
and when the modem has finally connected and synched up. With local (null modem
connections) or if the modem is run in auto-answer mode this is not normally a
problem. If used with a modem and the DTE (the computer end) wants to control the
connection the problem is more real. DSR would normally indicate the 'connected
and synched-up' state following DTR from the DTE. DCD will indicate that a carrier
has been received but does not indicate synchronization of both ends. In most cases
however CTS (Clear To Send) in response to RTS (Request To Send) will not
normally be returned until an end-to-end connection is available.
8-5-07 Page 3
ABB RS232 wiring standards
RS232 DB9 to DB25 Pinout
Use when connecting a DB9 (e.g. a PC) to a DB25 (e.g. a modem) interface. See the
full signal names in the DB9 and DB25 section.
Signal/pin primer
1 DCD 8
2 RD 3
3 TD 2
4 DTR 20
5 SGND 7
6 DSR 6
7 RTS 4
8 CTS 5
9 RI 22
8-5-07 Page 4
ABB RS232 wiring standards
RS232 DB25 NULL Modem Pinout
Use when connecting two systems (e.g. PCs) via their DB25 interfaces without a
modem (i.e. back-to-back). See the full signal names in the DB25 sections.
If this pinout does not work for you then you could try our Signal/pin primer because
you may need to SPOOF connections.
Note: This DB25 is NOT the same as the DB25 Parallel port on a PC which is defined
here.
3 RD 2 TD
2 TD 3 RD
20 DTR 6,8 DSR, DCD
6,8 DSR, DCD 20 DTR
4 RTS 5 CTS
5 CTS 4 RTS
7 SGND 7 SGND
22 RI 22 RI
NOTE:
8-5-07 Page 5
ABB RS232 wiring standards
RS232 DB9 NULL Modem Pinout
Use when connecting two systems (e.g. PCs) via their DB9 interfaces without a
modem (i.e. back-to-back). See the full signal names in the DB9 section.
If this pinout does not work for you then you could try our Signal/pin primer because
you may need to SPOOF connections.
2 RD 3 TD
3 TD 2 RD
4 DTR 6,1 DSR, DCD
6,1 DSR, DCD 4 DTR
7 RTS 8 CTS
8 CTS 7 RTS
5 SGND 5 SGND
9 RI 9 RI
NOTE:
1. We have received email suggesting that the above pinout looks like DTR from
one side is driving into DSR/DCD on the other side - not normally a healthy
situation. The emails miss the point that in a peer-to-peer, Null modem,
configuration both ends are DTEs. NEITHER should be attempting to drive the
DSR/DCD signals. They are essentially RX only signals on both sides.
8-5-07 Page 6
ABB RS232 wiring standards
RS232 DB9 to DB25 & RJ45 Wiring for ICI
Use when connecting a DB9 (e.g. a PC) to a DB25 (e.g. a modem) interface. See the
full signal names in the DB9 and DB25 section. Light blue indicates wiring used on
TMF and TMP ICI wiring.
Signal/pin primer
8-5-07 Page 7