You are on page 1of 10

Job Number Sheet

Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

S12
Beam - Column Connection - Ver W2.5.03 - 21 Oct 2010

Title : Default Connection


Code of Practice : AISC - 1999 LRFD
Created : 7/19/2013 4:18:34 AM

Notes and Assumptions


1 All bolt holes are assumed to be normal clearance holes.
2 All bolts are assumed to have threads in their shear planes.
3 It is assumed that the connection is deep enough for the flanges
to resist the compressive and tensile forces in them.
4 It is assumed that compressive forces in flanges and stiffeners
are conveyed through welds and not through bearing.
5 Axial force in the column is not considered in the design.

Summary

Summary of Forces and Capacities for Design to AISC - 1999 LRFD

Check Member Type LC Applied Capacity Units % of Cap. ?

1 Weld Flange 1 114.3 243.6 kN 46.9 O.K.

2 Weld Web 1 19.6 580.3 kN 3.4 O.K.

3 Column Web Tension Yielding 1 111.7 507.9 kN 22 O.K.

4 Column Web Compression Crippling 1 114.3 194.7 kN 58.7 O.K.

5 Column Web Compression Buckling 1 114.3 197.8 kN 57.8 O.K.

6 Column Web Shear 1 114.3 234.8 kN 48.7 O.K.

7 Bolts & Flange Tension & Bending 1 43.9 42.4 kN 103.4 Fail

8 Column Flange Bearing 1 2 186.3 kN 1 O.K.

9 Bolts & End Plate Tension & Bending 1 43.9 47.3 kN 92.7 O.K.

10 End Plate Bearing 1 2 243 kN 0.8 O.K.

11 Bolts Shear 1 2 37.7 kN 5.2 O.K.

12 Bolts Shear & Tension 1 21.9 70.6 kN 31.1 O.K.

13 Bolts Slip N/A N/A N/A kN N/A N/A

Input
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

General Settings
Bolt Tension Analysis Plastic
Bolt Type Bearing
Bolt Grade 4.6
Member Ultimate Strength 450
Member Yield Strength 240
Weld Ultimate Strength 480

Connection Type Flush End Plate


Column IPE300A I1
Beam IPE300A I1
Column Extent Above(mm) 30
Beam Angle -8
Haunch Depth (mm) 90
Haunch Length (mm) 200
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Ultimate Limit State Loads in Beam SLS Factor


(Divide to
Load Case Shear Axial Moment
get Loads)
(kN) (kN) (kNm)
1 19 5.3 43 1

Width (mm) 165


Extent Above Beam Flange (mm) N/A
End Plate Extent Below Haunch (mm) N/A
Thickness (mm) 12
Stiffeners N/A
Width (mm) None
Top Stiffener Thickness (mm) None
Column Stiffeners Bottom Stiffener Thickness (mm) None
Shear Stiffener Thickness (mm) None
Shear Stiffener Orientation None
Layout None
Web Plates
Thickness (mm) 10
Top Backing Plate Thickness (mm) None
Bottom Backing Plate Thickness (mm) None
Bolts Diameter (mm) 20
Above Top Flange N/A
Below Top Flange 4
Rows of Bolts Above Haunch 1
Below Haunch N/A
Row Spacing (mm) 65
Web (mm) 40
Bolt Offsets Flange (mm) 40
Above Haunch (mm) 50
Beam & Haunch Flanges 6
Beam Web (mm) 6
Welds Top Stiffener (mm) N/A
Bottom Stiffener (mm) N/A
Shear Stiffener (mm) N/A

Check 1 : Capacity of the Beam Flange Welds


The worst load is encountered for Load Case : 1
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Fw = 114.273 kN

Table J2.5

 . Fw. Aw
Rw =
1000
0.75 ×288 ×1 127.589
=
1000
= 243.559 kN

Beam Flange Weld is safe

Check 2 : Capacity of the Beam Web Welds


The worst load is encountered for Load Case : 1
Fw = 19.553 kN

Table J2.5

 . Fw. Aw
Rw =
1000
0.75 ×288 ×2 686.485
=
1000
= 580.281 kN

Beam Web Weld is safe

Check 3 : Capacity of the Column web in tension


Opposite Top flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =111.669 kN

The Capacity of the web is :


K1-3
tw. leff . f y
Rn =
1000
6.1 ×346.938 ×240
=
1000
= 507.917 kN

No tensile forces in the beam bottom flange

Column web is safe in tension

Check 4 : Crippling Capacity of the Column web in Compression


No compressive forces in the beam top flange
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Opposite Bottom flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =114.273 kN

The Capacity of the web is :


K1-3
tw. leff . f y
Rn =
1000
6.1 ×133 ×240
=
1000
= 194.712 kN

Column web is safe in compression for crippling

Check 5 : Buckling Capacity of the Column web in Compression


No compressive forces in the top beam flange

Opposite Bottom flange of the beam :

The worst load is encountered for Load Case : 1


when Fn =114.273 kN

K1-4
3 . N. tw 1.5 . f y. tf
 . 354.5 . tw2 . 1 +
d tf tw
Rn =
1000
3 ×9.29 6.1 1.5 240 ×9.2
0.75 ×354.5 ×6.1 2 × 1 + × ×
297 9.2 6.1
=
1000
= 197.759 kN

Column web is safe in compression for buckling

Check 6 : Shear Capacity of the Column Web


The worst load is encountered for Load Case : 1
when Pv =114.273 kN

K1-7
0.9 . 0.6 . f y. tw. dc
Rv =
1000
0.9 ×0.6 ×240 ×6.1 ×297
=
1000
= 234.796 kN

Column web shear is safe


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Check 7 : Bolt tension and Column Flange Bending


The worst load is encountered for Load Case : 1

Fmax = 43.89 kN
The resistance is the smaller of the 3 possible failure modes :

Mode 1 : Complete yielding of the flange

4 . Mpl + 2 . Mbp.
R1 = 1000
m
4 ×0.29709 + 2 ×0
= ×1000
28
= 42.441 kN

Mode 2 : Bolt Failure with yielding of the flange

2 . Mpl . 1000 + n . 2 . Bt
R2 =
m+n
2 ×0.29709 ×1000 + 31.95 ×2 ×73.5
=
28 + 31.95
= 88.254 kN

Mode 3 : Bolt Failure only

R3 = 2 . Bt
= 2 ×73.5
= 147.000 kN

Therefore R = R1 = 42.441

Bolt tension or Column flange bending failure

Check 8 : Bearing on the Column Flange


There are two checks : Check 1 :
The worst load is encountered for Load Case : 1
Fn = 1.955 kN

The Bearing Capacity of the flange at any Bolt is :


J3.10
 . 1.5 . Fu. Lc. t
Rn =
1000
0.75 ×1.5 ×450 ×40 ×9.2
=
1000
= 186.300 kN

Check 2 :
The Bearing Capacity of the Plate at any Bolt is :
J3.10
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

 . 3.0 . Fu. d . t
Rn =
1000
0.75 ×3.0 ×450 ×20 ×9.2
=
1000
= 186.300 kN

Column flange bearing is safe

Check 9 : Bolt tension and End Plate Bending


The worst load is encountered for Load Case : 1

Fmax = 43.89 kN
The resistance is the smaller of the 3 possible failure modes :

Mode 1 : Complete yielding of the End Plate

4 . Mpl .
R1 = 1000
m
4 ×0.50544
= ×1000
42.7
= 47.348 kN

Mode 2 : Bolt Failure with yielding of the End Plate

2 . Mpl . 1000 + n . 2 . Bt
R2 =
m+n
2 ×0.50544 ×1000 + 31.95 ×2 ×73.5
=
42.7 + 31.95
= 76.457 kN

Mode 3 : Bolt Failure only

R3 = 2 . Bt
= 2 ×73.5
= 147.000 kN

Therefore R = R1 = 47.348

Bolt tension and End Plate bending is safe

Check 10 : Bearing on the End Plate


There are two checks : Check 1 :
The worst load is encountered for Load Case : 1
Fn = 1.955 kN

The Bearing Capacity of the Plate at any Bolt is :


J3.10
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

 . 1.5 . Fu. Lc. t


Rn =
1000
0.75 ×1.5 ×450 ×40 ×12
=
1000
= 243.000 kN

Check 2 :
The Bearing Capacity of the Plate at any Bolt is :
J3.10
 . 3.0 . Fu. d . t
Rn =
1000
0.75 ×3.0 ×450 ×20 ×12
=
1000
= 243.000 kN

End plate bearing is safe

Check 11 : Shear Capacity of the Bolts


The worst load is encountered for Load Case : 1
when Fn =1.955 kN

J3.6
C-J3-4
Fn = 0.4 . Fu
= 0.4 ×400
= 160.000 MPa

The resistance of any bolt is :

n .  . F n. A b
Rshear =
1000
1 ×0.75 ×160.000 ×314.159
=
1000
= 37.699 kN

Bolt shear is safe

Check 12 : Shear and Tension Capacity of the Bolts


The worst load is encountered for Load Case : 1
when Fn =21.945 kN

C-J3.7
J3.7
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

The resistance of any bolt is :

 . Ft . A b
Rn =
1000
0.75 ×299.773 ×314.159
=
1000
= 70.632 kN

Bolt shear and tension is safe


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Bolt Forces

Bolt Forces for Load Case : 1

21.94 kN

21.94 kN

21.94 kN

21.94 kN

0 kN

Shear force per bolt : 1.96 kN