You are on page 1of 16

COMFORT APPLICATION

HYDRONIC TERMINALS

ELEGANCE AND DESIGN


FOR YOUR RESIDENTIAL
COMFORT

climaveneta.com
COMFORT APPLICATION
HYDRONIC TERMINALS

between elegance, comfort


and energy savings
Conceived to make every kind of residential environment
more comfortable, the new i-LIFE2 Slim fan coil integrates
excellent performance with an irresistible charm.

02/03
02/03

13 cm

ELEGANT DESIGN
i-LIFE2 Slim is the new Climaveneta brand fan coil specially
designed to perfectly fit the environment where it is installed.

Featuring a harmonious design and an extraordinary depth of only


13 cm, i-LIFE2 Slim complements the real interior design and fits
perfectly in modern architectures.

-50% REDUCED ENERGY CONSUMPTION


Thanks to the DC motor with Inverter technology, i-LIFE2 Slim features
an electrical absorption rate 50% lower than traditional fan coil units
with the same size.

The innovative combination of the radiant effect with the finned coil
ensures the heating function with lower water temperature compared
to a traditional radiator (45°C instead of 65°C), with a very low energy
expense.
COMFORT APPLICATION
HYDRONIC TERMINALS

04/05
04/05

for heating, cooling


and dehumidifying
Breathing clean air is a key element for a healthy lifestyle.
i-LIFE2 Slim is the wellness that you can see and feel.

SILENT COMFORT
The i-LIFE2 Slim fan coil is a synonym of perfect comfort in the
environment, in every season.
The brushless motor quickly reaches the desired comfort level to keep
this general wellness over time, without any temperature fluctuation.

Centrifugal fans operate through continuous air flow modulation,


generating extremely low sound emissions.

CLEAN AIR FOR A HEALTHY LIFESTYLE


Your wellness is in the air: with i-LIFE2 Slim you can breathe cleaner air.

The fan coil is equipped with an UVC emitter that helps environmental
sterilization and ensures a high quality of indoor air treatment.
It is well-known that UVC rays have high antibacterial efficacy.
The use of this component guarantees a cleaner and healthier
environment and provides a feeling of well-being and relaxation.
COMFORT APPLICATION
HYDRONIC TERMINALS

AIR DEFLECTORS CABINET


The new automatic opening and closing system smartly The elegant layout of the i-LIFE2 Slim
manages the airflow from the deflectors, ensuring quick has been specifically designed to
comfort in the environment. perfectly fit into its environment.
The linear and modern design of
its casing with minimal lines and
gentle curves is obtained by using
high quality plastic materials
combined with traditional galvanized
sheet steel and epoxy powder coating.

AIR FILTER AND FRONT AIR INTAKE


All the units are provided with a honeycomb
polypropylene regenerable filter (Class G1).
There is easy access to the filter through the
removable front grid in order to make cleaning easier.
For environments with high air quality requirements,
an UVC emitter is available as an accessory. The UV
rays guarantee antibacterial efficacy, ensuring perfect
sterilization and providing the feeling of well-being
for the occupants.

06/07
06/07

Smart and functional technological choices conceived to ensure perfect comfort


in every moment. Cooling, heating, ventilation and air purification combined with
reduced energy consumption and sound emissions: this is now possible thanks
to high quality components designed for the well-being of the tenants.

DESIRED TEMPERATURE
REACHED QUICKLY
Thanks to the advanced functions
of the panel with PID logic, the desired
temperature is reached quickly.
With a simple click, in a few minutes
you can achieve the desired level
of comfort, without wasting precious
energy.

HEAT EXCHANGER
The heat exchanger has an extensive
front surface that ensures high airflows
to be achieved with low pressure loss.
All units are supplied with hydraulic
connections on the left, and upon
request on the right.

VENTILATION SECTION
The fan is tangential with asymmetric
blades and a DC electronic inverter motor.
Thanks to the inverter technology, the fan
speed is continuously modulated for better
comfort and real energy savings.
COMFORT APPLICATION
HYDRONIC TERMINALS

Thanks to 4 versions with cabinet and built-in mounting,


for horizontal or vertical installation, the ideal solution
is guaranteed for any project.

i-LIFE2 Slim DLRV


With cabinet
and radiating effect
for vertical wall
installation

08/09
08/09

i-LIFE2 Slim DLMO


With cabinet, for horizontal
ceiling installation i-LIFE Slim Box

i-LIFE Slim DLIU

i-LIFE2 Slim DLMO


Box module for wall installation

i-LIFE2 Slim DLIU


Built-in version, for vertical/horizontal
installation

i-LIFE2 Slim DLMV


With cabinet and feet, for vertical
floor installation
COMFORT APPLICATION
HYDRONIC TERMINALS

With cabinet and radiating effect for vertical installation

Heat dispersion
and convention
towards the
environment

The key feature of the DLRV version is the


micro fans positioned between the heat Micro
exchanger and the front panel. fans

These micro fans are connected in


parallel to the water valves and they start
functioning when the water temperature
rises above 35°C.

Through a simple function selection on


the control panel, the tangential fan stops
and the micro fans start working releasing
hot air through the frontal panel, thus Hot air
ensuring natural radiant heat dispersion transit
and convection with the lowest sound
emissions.

Air
intake

10/11
10/11

Box module for wall installation

Galvanized steel
Built-in wall niche
DLIU unit

Closure panel
manufactured in
galvanized steel

Different sizes
available according
to the different sizes
of the fan coil units

Quick and easy


cleaning of the
components

Painted external frame


to perfectly hide eventual
imperfections in the wall

i-LIFE2 Slim Box has been specifically designed Simplified operations on the construction sites
to fit the rational architecture of modern buildings.
During the first stages of installation, the casing
From the first stage of the building’s construction, for built-in installation is placed in the wall niche and
the unit can be positioned into the wall niches and the electrical and water connections are prepared.
render the execution of the system more rational,
efficient and aesthetically harmonious. The positioning of the fan coil is easy and can be
carried out when site operations are concluded.
The fan coil, accurately embedded inside the wall
module, will be practically invisible and hidden behind Thanks to its reduced thickness, i-LIFE2 Slim can
the wall. blend easily into all types of walls and false ceilings,
including thin ones.
COMFORT APPLICATION
HYDRONIC TERMINALS

Controllers

The wide range of available wall-mounted and on-board controllers,


allows for a user-friendly and complete regulation of all the functions.
The advanced management system with PID logic modulates the fan
speed maintaining a perfect temperature and humidity level, reducing
the sound emissions and ensuring high efficiency.

iKS2
On-board control for units with cabinet complete
with keypad with 8 touch keys, LCD display with
white light symbols.
 Modulating fan speed with PID logic,
 Temperature regulation,
 Winter/Summer mode,
 Automatic mode for speed regulation,
 Night mode for a silent operation
 Minimum water temperature probe
and solenoid valve management.

ATS2
On-board controller for units with cabinet.
Interface with 4 keys for the temperature
selection.
 Winter/Summer mode,
 4 speed regulation,
 Display for the visualization
of the room temperature,
 Minimum water temperature probe
and solenoid valve management.

All i-LIFE2 Slim units can be part of a network of units managed by the Idrorelax centalized system.
In this case a IRS bridge will be included in each fan coil.

On board or
remote controls in Remote Control
multiple connection IKW2
configuration

Power Board Power Board Power Board Power Board Power Board
IHBS2 IHBS2 IHBS2 iHBS2 iHBS2

It’s possible to connect up to 31 units with 1 remote control IKSW2

12/13
12/13

iKSW2+iHBS2
Remote controller for built-in and with cabinet units complete
with keypad with 8 touch keys, LCD display with white
light symbols.
 Modulating fan speed with PID logic,
 Temperature regulation,
 Winter/Summer mode,
 Automatic mode for speed regulation,
 Night mode for a silent operation,
 Minimum water temperature probe and
solenoid valve management.
A maximum of 31 fan coils can be connected to the iKSW2
controller for open space rooms.

iHBS2 control board


Simple control board for built-in and with cabinet units
to be coupled with remote controller iKSW2. iHBS2 features
an ON/OFF touch button and a LED for the visualization
of the device’s operation.
All the parameters are set from the iKSW2.

Remote Control
ATW2+HBS2 IKW2

Room thermostat for built-in and with cabinet units.


 Manual and automatic speed regulation,
Power Board Power Board Power Board Power Board Power Board
 Room probe and minimum
IHBS2 temperature probe
IHBS2 IHBS2 iHBS2 iHBS2
 Control of solenoid valves,
 Multifunctional digital contact
 Dip switch configuration.
The ATW2 control must be coupled
with the HBS2 power board.
The HBS2 0-10V power board is available
for the 0-10V signal.

On board and remote


Remote Control Remote Control
controllers, multiple IKSW2 IKSW2
connections and idrorelax.
Power Power Power
Board Board Board Bridge
IHBS2 IHBS2 IS2 IRS2

i-LIFE SLIM w/o casing i-LIFE SLIM w/o casing i-LIFE SLIM w/o casing

Control Control Power Board


Remote
IKS2 IKS2 IHBS2
Control
IKSW2
Bridge Bridge
IRS2 IRS2
COMFORT APPLICATION
HYDRONIC TERMINALS

FAN COIL UNIT WITH


DC INVERTER MOTOR
AND TANGENTIAL FAN

i-LIFE2 Slim units are managed by a DC motor with


Inverter technology that continuously modulates the fan VERSIONS
speed. The values at high, medium and low speed are
Eurovent certified and are presented below. DLIU Built-in version for universal installation
DLMV Version with cabinet for vertical installation
DLMO Version with cabinet for horizontal installation
DLRV Radiant Version with cabinet for vertical installation

i-LIFE2 SLIM / DLMO - DLMV


i-LIFE2 SLIM 080
080 170
170 270
270 320
320 370
370
ELECTRICAL DATA
Power supply V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
2 PIPES SYSTEM CONFIGURATION
ENERGY EFFICIENCY
COOLING (EN14511 VALUE)
FCEER (1)(6) kW/kW 150 197 320 294 275
FCEER Class B A A A A
HEATING ONLY (EN14511 VALUE)
FCCOP (2)(6) kW/kW 183 262 387 401 346
FCCOP Class B B A A A
PERFORMANCE
MIN SPEED
Fan Power Input (1) W 0,70 1,62 1,82 2,47 4,91
Air flow rate (1) m³/h 51 122 189 258 367
Total capacity in cooling mode (1) kW 0,40 0,81 1,32 1,62 2,00
Total Net Cooling Capacity (1)(6)(7) kW 0,40 0,81 1,32 1,62 2,00
Sensible capacity in cooling mode (1) kW 0,30 0,67 1,03 1,38 1,71
Net sensible cooling capacity (1)(6)(7) kW 0,30 0,67 1,03 1,38 1,70
Net latent power in cooling (1)(6)(7) kW 0,10 0,14 0,29 0,24 0,30
Max water flow (1) l/s 0,02 0,04 0,06 0,08 0,10
Pressure Drop in cooling mode (1) kPa 2 1 6 5 6
Total capacity (heating mode) (2) kW 0,50 1,06 1,54 2,22 2,48
Total Net Heating Capacity (2)(6) kW 0,50 1,06 1,54 2,22 2,48
Water flow in heating mode (2) l/s 0,02 0,05 0,07 0,11 0,12
Pressure drop in heating mode (2) kPa 3 2 8 9 10
Sound Pressure (3) dB(A) 24 26 27 27 31
Sound Power (4)(7) dB(A) 33 35 36 36 40
MED SPEED
Fan Power Input (1) W 4,46 10,1 9,86 11,3 12,3
Air flow rate (1) m³/h 93 221 334 430 499
Total capacity in cooling mode (1) kW 0,69 1,39 2,18 2,52 2,82
Total Net Cooling Capacity (1)(6)(7) kW 0,69 1,38 2,17 2,51 2,81
Sensible capacity in cooling mode (1) kW 0,54 1,17 1,72 2,24 2,40
Net sensible cooling capacity (1)(6)(7) kW 0,54 1,16 1,71 2,23 2,39
Net latent power in cooling (1)(6)(7) kW 0,15 0,22 0,46 0,28 0,42
Max water flow (1) l/s 0,03 0,07 0,10 0,12 0,14
Pressure Drop in cooling mode (1) kPa 5 3 15 11 13
Total capacity (heating mode) (2) kW 0,78 1,65 2,40 3,07 3,41
Total Net Heating Capacity (2)(6) kW 0,78 1,66 2,41 3,08 3,43
Water flow in heating mode (2) l/s 0,04 0,08 0,12 0,15 0,16
Pressure drop in heating mode (2) kPa 6 5 19 16 20
Sound Pressure (3) dB(A) 35 36 37 38 39
Sound Power (4)(7) dB(A) 44 45 46 47 48
MAX SPEED
Fan Power Input (1) W 10,7 19,0 20,0 29,0 33,0
Air flow rate (1) m³/h 125 277 425 593 697
Total capacity in cooling mode (1) kW 0,76 1,75 2,75 3,22 3,76
Total Net Cooling Capacity (1)(6)(7) kW 0,75 1,73 2,73 3,19 3,73
Sensible capacity in cooling mode (1) kW 0,66 1,53 2,21 3,02 3,30
14/15 Net sensible cooling capacity (1)(6)(7) kW 0,65 1,51 2,19 2,99 3,27
Net latent power in cooling (1)(6)(7) kW 0,10 0,22 0,54 0,20 0,46
FCEER
i-LIFE2 SLIM / DLMO - DLMV (1)(6) kW/kW 150
080 197
170 320
270 294
320 275
370
FCEER Class B A A A A
ELECTRICAL DATA
HEATING ONLY (EN14511 VALUE)
Power supply V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 14/15
FCCOP (2)(6) kW/kW 183 262 387 401 346
2 PIPESClass
FCCOP SYSTEM CONFIGURATION B B A A A
ENERGY
PERFORMANCE EFFICIENCY
COOLING
MIN SPEED (EN14511 VALUE)
FCEER
Fan Power Input/ DLIU
(1)(6)
(1) kW/kW W 150
FANCOIL
0,70 1972 PIPES
1,62 320 TANGENT. 2,47
1,82 294 CONTROL 4,91 275
i-LIFE2
FCEER
SLIM
Class
080
B
170
A
270
A
320
A
370
A
Air flow rate (1) m³/h 51 122 189 258 367
ELECTRICAL
HEATING ONLY DATA
Total capacity in(EN14511
cooling mode VALUE) (1) kW 0,40 0,81 1,32 1,62 2,00
Power supply
FCCOP (2)(6) V/ph/Hz
kW/kW 230/1/50
183 230/1/50
262 230/1/50
387 230/1/50
401 230/1/50
346
Total Net Cooling Capacity (1)(6)(7) kW 0,40 0,81 1,32 1,62 2,00
2 PIPESClass
FCCOP
Sensible SYSTEM
capacity inCONFIGURATION
cooling mode (1) kW B
0,30 B
0,67 A
1,03 A
1,38 A
1,71
ENERGY
PERFORMANCE
Net sensible EFFICIENCY
cooling capacity (1)(6)(7) kW 0,30 0,67 1,03 1,38 1,70
COOLING
Net latent
MIN SPEED (EN14511
power VALUE)
in cooling (1)(6)(7) kW 0,10 0,14 0,29 0,24 0,30
FCEER
i-LIFE2
waterSLIM
Max Power
Fan Input/ DLRV
flow (1)(6)
(1) kW/kW l/s
W 150
080
0,02
0,70 197
170
0,04
1,62 320
270
0,06
1,82 294
320
0,08
2,47 275
370
0,10
4,91
FCEER
Pressure
Air Class
flow rateDrop DATA
in cooling mode (1) kPa
m³/h B
2
51 A1
122 A6
189 A5
258 A
6
367
ELECTRICAL
HEATING
Total
Powercapacity ONLY
supply in (EN14511
(heating
cooling mode)VALUE)
mode (2)
(1)
V/ph/HzkW 0,50
0,40
230/1/50 1,06
0,81
230/1/50 1,54
1,32
230/1/50 2,22
1,62
230/1/50 2,48
2,00
230/1/50
FCCOP
Total Heating Capacity
NetSYSTEM
Cooling (2)(6)
(1)(6)(7) kW/kW kW 183
0,50
0,40 262
1,06
0,81 387
1,54
1,32 401
2,22
1,62 346
2,48
2,00
2 PIPES CONFIGURATION
FCCOP
Water flow
Sensible Class
in heating
capacity mode mode
in cooling (2)
(1) l/s
kW B
0,02
0,30 B
0,05
0,67 A
0,07
1,03 A
0,11
1,38 A
0,12
1,71
ENERGY
Pressure EFFICIENCY
dropcooling
in heating mode kPa 3 2 8 9 10
Net sensible
PERFORMANCE capacity (2)
(1)(6)(7) kW 0,30 0,67 1,03 1,38 1,70
COOLING
Sound
Net latent (EN14511
Pressure
power in cooling VALUE) (3)
(1)(6)(7) dB(A)
kW 24
0,10 26
0,14 27
0,29 27
0,24 31
0,30
MIN SPEED
FCEER
i-LIFE2
Sound
Max SLIM
Power
water flow (1)(6)
(4)(7)
(1) kW/kW
dB(A)l/s 150
080
33
0,02 197
170
35
0,04 320
270
36
0,06 294
320
36
0,08 275
370
40
0,10
Fan Power Input (1) W 0,70 1,62 1,82 2,47 4,91
FCEER
Pressure
MED Class
SPEEDDrop in cooling mode (1) kPa B
2 A1 A6 A5 A
6
Air flow rate (1) m³/h 51 122 189 258 367
HEATING
Total
Fan Power
Total ONLY
capacity
capacity in(EN14511
Input(heating
cooling mode)VALUE)
mode (2)
(1) kW
W
kW 0,50
4,46
0,40 1,06
10,1
0,81 1,54
9,86
1,32 2,22
11,3
1,62 2,48
12,3
2,00
FCCOP
Total
Air flow
Total Net
Net Heating Capacity
rate
Cooling Capacity
(2)(6)
(2)(6)
(1)
(1)(6)(7) kW/kW kW
m³/h
kW 183
0,50
93
0,40 262
1,06
221
0,81 387
1,54
334
1,32 401
2,22
430
1,62 346
2,48
499
2,00
FCCOP
Water Class
flow
Total capacity
Sensible in heating
capacity in in modemode
cooling
cooling mode (2)
(1) l/s
kW B
0,02
0,69
0,30 B
0,05
1,39
0,67 A
0,07
2,18
1,03 A
0,11
2,52
1,38 A
0,12
2,82
1,71
i-LIFE2
PERFORMANCE
Pressure
Total
Net sensible
SLIM
Netdrop
Cooling /
cooling
DLRV
in heating
Capacitymode
capacity (2)
(1)(6)(7) kPa
kW
080
3
0,69
0,30
170
2
1,38
0,67
2708
2,17
1,03
3209
2,51
1,38
370
10
2,81
1,70
Sound
ELECTRICAL
MIN
Net Pressure
SPEED
Sensible
latent power DATA
capacity inincooling
cooling mode (3)
(1)
(1)(6)(7) dB(A)
kW 24
0,54
0,10 26
1,17
0,14 27
1,72
0,29 27
2,24
0,24 31
2,40
0,30
Sound
Power
Fan Power
supply
Power
Net sensible
Max water Input
cooling capacity
flow (4)(7)
(1)
(1)(6)(7)
(1) dB(A)
V/ph/Hz W
kW
l/s 33
230/1/50
0,70
0,54
0,02 35
230/1/50
1,62
1,16
0,04 36
230/1/50
1,82
1,71
0,06 36
230/1/50
2,47
2,23
0,08 40
230/1/50
4,91
2,39
0,10
Air
Net
MED
2 flow
latent
PIPES
Pressure rate
SPEED power
SYSTEM
Drop in in cooling
CONFIGURATION
cooling mode (1)
(1)(6)(7)
(1) m³/h
kW
kPa 51
0,15
2 122
0,22
1 189
0,46
6 258
0,28
5 367
0,42
6
Total
Max
Fan
ENERGY capacity
water
Power Inputin
flow cooling
(heating
EFFICIENCY mode
mode) (1)
(2) l/s
W
kW 0,40
0,03
4,46
0,50 0,81
0,07
10,1
1,06 1,32
0,10
9,86
1,54 1,62
0,12
11,3
2,22 2,00
0,14
12,3
2,48
Total
Pressure
Air flow
COOLING Net Cooling
Drop
rate
Heatingin cooling
(EN14511 Capacitymode
VALUE) (1)(6)(7)
(1)
(2)(6) kPa
m³/h
kW 0,40
5
93
0,50 0,81
3
221
1,06 1,32
15
334
1,54 1,62
11
430
2,22 2,00
13
499
2,48
Sensible
Total
Water
FCEER flowcapacity
capacity in
in heating in
(heatingcooling
cooling
mode mode)mode
mode (1)
(2)
(1)(6) kW/kW kW
l/s 0,30
0,78
0,69
0,02
150 0,67
1,65
1,39
0,05
197 1,03
2,40
2,18
0,07
320 1,38
3,07
2,52
0,11
294 1,71
3,41
2,82
0,12
275
Net
Totalsensible
Pressure
FCEER Net drop
Class cooling
Heating
Cooling
in heating capacity
Capacitymode (2)(6)
(1)(6)(7)
(2) kW
kPa 0,30
0,78
0,69
3
B 0,67
1,66
1,38
A2 1,03
2,41
2,17
A8 1,38
3,08
2,51
A9 1,70
3,43
2,81
10
A
Net
Waterlatent
Sensible
Sound flow power
in heating
capacity
Pressure inincooling
mode mode
cooling (1)(6)(7)
(2)
(1)
(3) l/s
kW
dB(A) 0,10
0,04
0,54
24 0,14
0,08
1,17
26 0,29
0,12
1,72
27 0,24
0,15
2,24
27 0,30
0,16
2,40
31
HEATING ONLY (EN14511 VALUE)
Max
Net
Sound water
Pressure
sensible
Powerflow
drop in
coolingheating mode
capacity (1)
(2)
(1)(6)(7)
(4)(7) l/s
kPa
kW
dB(A) 0,02
6
0,54
33 0,04
5
1,16
35 0,06
19
1,71
36 0,08
16
2,23
36 0,10
20
2,39
40
FCCOP (2)(6) kW/kW 183 262 387 401 346
Pressure
Sound
Net
MED latent
SPEEDDrop
Pressure
power in incooling
cooling mode (1)
(3)
(1)(6)(7) kPa
dB(A)
kW 2
35
0,15 1
36
0,22 6
37
0,46 5
38
0,28 6
39
0,42
FCCOP Class B B A A A
Total
Sound
Max
Fan capacity
Power
water flow
Power Input (heating mode) (2)
(4)(7)
(1)
(1) kW
dB(A)l/s
W 0,50
44
0,03
4,46 1,06
45
0,07
10,1 1,54
46
0,10
9,86 2,22
47
0,12
11,3 2,48
48
0,14
12,3
PERFORMANCE
Total Net Heating Capacity (2)(6) kW 0,50 1,06 1,54 2,22 2,48
Pressure
MAX
Air flowSPEEDDrop
rate in cooling mode (1)
(1) kPa
m³/h 5
93 3
221 15
334 11
430 13
499
MIN SPEED
Water
Total flow in
capacity heating
(heating mode mode) (2) l/s
kW 0,02
0,78 0,05
1,65 0,07
2,40 0,11
3,07 0,12
3,41
Fan
TotalPower
capacityInput in cooling mode (1) W
kW 10,7
0,69 19,0
1,39 20,0
2,18 29,0
2,52 33,0
2,82
Fan Power
Pressure
Total Net Input
drop in heating
Heating Capacitymode (1)
(2)
(2)(6) W
kPa
kW 0,70
3
0,78 1,62
2
1,66 1,82
8
2,41 2,47
9
3,08 4,91
10
3,43
Air flow
Total Netrate
Cooling Capacity (1)
(1)(6)(7) m³/h
kW 125
0,69 277
1,38 425
2,17 593
2,51 697
2,81
Air flowflow
Sound
Water ratein heating mode
Pressure (1)
(3)
(2) m³/h
dB(A)l/s 51
24
0,04 122
26
0,08 189
27
0,12 258
27
0,15 367
31
0,16
Total
Sensiblecapacity
capacity in incooling
coolingmode mode (1) kW 0,76
0,54 1,75
1,17 2,75
1,72 3,22
2,24 3,76
2,40
Total capacity
Sound
Pressure Power
drop ininheating
coolingmode mode (1)
(4)(7)
(2) kW
dB(A)
kPa 0,40
33
6 0,81
35
5 1,32
36
19 1,62
36
16 2,00
40
20
Total Net
Net sensible Cooling
cooling Capacity
capacity (1)(6)(7) kW 0,75
0,54 1,73
1,16 2,73
1,71 3,19
2,23 3,73
2,39
Total SPEED
Sound
MED Net Cooling Capacity
Pressure
(1)(6)(7)
(3) kW
dB(A) 0,40
35 0,81
36 1,32
37 1,62
38 2,00
39
Sensible
Net latent capacity
power inincooling
cooling mode (1)
(1)(6)(7) kW 0,66
0,15 1,53
0,22 2,21
0,46 3,02
0,28 3,30
0,42
Sensible
Sound
Fan Power capacity
Power Input in cooling mode (1)
(4)(7)
(1) kW
dB(A)W 0,30
44
4,46 0,67
45
10,1 1,03
46
9,86 1,38
47
11,3 1,71
48
12,3
Net
Maxsensible
water cooling capacity
flow (1)(6)(7)
(1) kW
l/s 0,65
0,03 1,51
0,07 2,19
0,10 2,99
0,12 3,27
0,14
Netflow
Air sensible
rate cooling capacity (1)(6)(7)
(1) kW
m³/h 0,30
93 0,67
221 1,03
334 1,38
430 1,70
499
Net
MAX latent
PressureSPEED power
Drop in in cooling
cooling mode (1)(6)(7)
(1) kW
kPa 0,10
5 0,22
3 0,54
15 0,20
11 0,46
13
Net latent
Total powerinincooling
capacity cooling mode (1)(6)(7) kW
kW 0,10
0,69 0,14
1,39 0,29
2,18 0,24
2,52 0,30
2,82
Max Power
Fan water flow
Input(heating mode) (1)
(2) l/s
W 0,04
10,7
0,78 0,08
19,0
1,65 0,13
20,0
2,40 0,15
29,0
3,07 0,18
33,0
3,41
Max water
Total Net flow
Cooling Capacity
(1)
(1)(6)(7) l/s
kW 0,02
0,69 0,04
1,38 0,06
2,17 0,08
2,51 0,10
2,81
Pressure
Air flow Drop
rate
Heatingin cooling mode (1)
(2)(6) kPa
m³/h 6
125
0,78 5
277
1,66 24
425
2,41 17
593
3,08 24
697
3,43
Pressure capacity
Sensible Drop in cooling
in coolingmode mode
(1) kPa 2
0,54 1
1,17 6
1,72 5
2,24 6
2,40
Total
Watercapacity (heating
in
flow in heating cooling
mode mode)
mode (1)
(2) kW
l/s 0,88
0,76
0,04 2,11
1,75
0,08 3,27
2,75
0,12 3,88
3,22
0,15 4,33
3,76
0,16
Total
Net capacity
sensible (heating
cooling mode)
capacity
(2) kW 0,50
0,54 1,06
1,16 1,54
1,71 2,22
2,23 2,48
2,39
Total
Pressure Heating
Netdrop
Cooling Capacity
in heating mode (2)(6)
(1)(6)(7)
(2) kW
kPa 0,89
0,75
6 2,13
1,73
5 3,29
2,73
19 3,91
3,19
16 4,36
3,73
20
Total
Net Net Heating
latent power ininCapacity
cooling
(2)(6)
(1)(6)(7) kW 0,50
0,15 1,06
0,22 1,54
0,46 2,22
0,28 2,48
0,42
Water
Sensible
Sound flow in heating
capacity
Pressure mode mode
cooling (2)
(1)
(3) dB(A)l/s
kW 0,04
0,66
35 0,10
1,53
36 0,16
2,21
37 0,19
3,02
38 0,21
3,30
39
Waterwater
Max flow flow
in heating mode (2)
(1) l/s
l/s 0,02
0,03 0,05
0,07 0,07
0,10 0,11
0,12 0,12
0,14
Pressure
Net
Soundsensibledropcooling
Power in heating mode
capacity (2)
(1)(6)(7)
(4)(7) kPa
kW
dB(A) 8
0,65
44 8
1,51
45 33
2,19
46 25
2,99
47 32
3,27
48
Pressure Drop
Pressure drop in in heating
cooling mode
mode
(2)
(1) kPa
kPa 3
5 2
3 8
15 9
11 10
13
Sound
Net
MAX Pressure
latent
SPEED power in cooling (3)
(1)(6)(7) dB(A)
kW 41
0,10 42
0,22 44
0,54 46
0,20 47
0,46
Soundcapacity
Total Pressure(heating mode) (3)
(2) dB(A)
kW 24
0,78 26
1,65 27
2,40 27
3,07 31
3,41
Sound
Max
Fan Power
water
Power flow
Input (4)(7)
(1)
(1) dB(A)l/s
W 50
0,04
10,7 51
0,08
19,0 53
0,13
20,0 55
0,15
29,0 56
0,18
33,0
SoundNet
Total Power
Heating Capacity
(4)(7)
(2)(6) dB(A)
kW 33
0,78 35
1,66 36
2,41 36
3,08 40
3,43
Pressure
SIZE
Air flowAND Drop
rateWEIGHTin cooling mode (1)
(1) kPa
m³/h 6
125 5
277 24
425 17
593 24
697
MED SPEED
Water
Total flow in heating
capacity (heating mode mode) (2) l/s
kW 0,04
0,88 0,08
2,11 0,12
3,27 0,15
3,88 0,16
4,33
A
Total capacity in cooling mode (5)
(1) mm
kW 737
0,76 937
1,75 1137
2,75 1337
3,22 1537
3,76
Fan Power
Pressure Input (1) W 4,46 10,1 9,86 11,3 12,3
Total
B
Total Netdrop
Net in heating
Heating
Cooling Capacity
Capacitymode (2)
(2)(6)
(5)
(1)(6)(7) kPa
kW
mm
kW 6
0,89
131
0,75 5
2,13
131
1,73 19
3,29
131
2,73 16
3,91
131
3,19 20
4,36
131
3,73
Air flowflow
Sound
Water ratein heating mode
Pressure (1)
(3)
(2) m³/h
dB(A)l/s 93
35
0,04 221
36
0,10 334
37
0,16 430
38
0,19 499
39
0,21
H
Sensible capacity in cooling mode (5)
(1) mm
kW 579
0,66 579
1,53 579
2,21 579
3,02 579
3,30
Total capacity
Sound
Pressure Power
drop ininheating
coolingmode mode (1)
(4)(7)
(2) kW
dB(A)
kPa 0,69
44
8 1,39
45
8 2,18
46
33 2,52
47
25 2,82
48
32
Operating
Net sensible weight
cooling capacity (5)
(1)(6)(7) kg
kW 17
0,65 20
1,51 23
2,19 26
2,99 29
3,27
Total
Sound
MAX Net Cooling Capacity
Pressure
SPEED
(1)(6)(7)
(3) kW
dB(A) 0,69
41 1,38
42 2,17
44 2,51
46 2,81
47
Net latent
Notes: power in cooling (1)(6)(7) kW 0,10 0,22 0,54 0,20 0,46
Sensible
i-LIFE2 capacity
SLIM
Input/ 27 in cooling
DLMO mode
- DLMV (1) kW 0,54
080
50 1,17
170
51 1,72
270
53 2,24
320
55 2,40
370
1Sound
Fan
Max
Room Power
Power
water flow
temperature °C d.b./19 °C w.b.; Chilled water(4)(7)(1)
(1)
(in/out) dB(A)
7/12 W
l/s
°C. 10,7
0,04 19,0
0,08 20,0
0,13 29,0
0,15 56
33,0
0,18
2Net sensible cooling capacity kW 0,54 1,16 1,71 2,23 2,39
(1)(6)(7)
Air
SIZEflow
Room
PressureANDrateWEIGHT
temperature
Drop 20 °C
in cooling d.b.;
modeHot water (in/out) 45/40 °C (1)
(1) m³/h
kPa 125
6 277
5 425
24 593
17 697
24
3Net
Totallatent
ASoundcapacity
power
pressure in incooling
level cooling
in freemode)
(heating field
modeon a reflective surface,(1)(6)(7)
(1)1 m from fan
(5)
(2)
kW
mm
0,15
kWfront and 0,88
0,76
737
0,22
1 m from the ground.
937
0,46
Non -binding value
1,75
2,11 2,75
1137
3,27
0,28
obtained fron sound 0,42
3,88power level. 1537
3,22
1337 3,76
4,33
4Max
Sound
Total
B
water
powerflow
on
Net Cooling the basis of measurements made in (1)
compliance
(1)(6)(7)
(5) with
mm
l/s
ISO 3741 0,03
and
0,75
131 Eurovent 8/2. 0,07
1,73
131
0,10
2,73
131
0,12
3,19
131
0,14
3,73
131
5Pressure
Heating Capacity (2)(6) kW 0,89 2,13 3,29 3,91 4,36
Sensible Drop configuration/execution,
Unit in standard
capacityin cooling
in coolingmode mode without optional(5)
(1)
accessories.
(1) kPa
kW 5
0,66 3
1,53 15
2,21 11
3,02 13
3,30
HValuesflow
6Water in heating mode (2) mml/s 579
0,04 579
0,10 579
0,16 579
0,19 579
0,21
Total capacity (heating
in compliance with mode)
EN14511-3:2013. (2) kW 0,78 1,65 2,40 3,07 3,41
7Net sensible cooling capacity kW 0,65 1,51 2,19 2,99 3,27
Operating
Pressure weight
drop in heating mode (1)(6)(7)
(5)
(2) kg
kPa 17
8 20
8 23
33 26
25 29
32
Values
Total in compliance
Net Heating with [REGULATION (UE) N.2016/2281]
in Capacity kW 0,78 1,66 2,41 3,08 3,43
(2)(6)
Net
Soundlatent
Certified power
Pressure
data cooling (1)(6)(7)
(3) kW
dB(A) 0,10
41 0,22
42 0,54
44 0,20
46 0,46
47
Notes:
Water flow ininheating
EUROVENT
mode (2) l/s 0,04 0,08 0,12 0,15 0,16
1Max
Sound
Room water
i-LIFE2 Powerflow
SLIM
temperature / DLMO
27 -
°C d.b./19 DLIU
°C w.b.; (1)
Chilled water(4)(7)
(in/out) dB(A)
7/12 l/s
°C. 0,04
080
50 0,08
170
51 0,13
270
53 0,15
320
55 0,18
370
56
Pressure
2Pressure
RoomAND
drop
Drop
temperature
in heating
in cooling
20 °C d.b.;
mode
modeHot water (in/out) 45/40 °C
(2)
(1) kPa
kPa 6
6 5
5 19
24 16
17 20
24
SIZE WEIGHT
3Sound
Total
Sound Pressure
capacity (heating mode)
pressure level in free field on a reflective surface, (3)1 m fromdB(A)
(2) fan
kW front and 35
1 m
0,88 from the 36
ground. Non
2,11 -binding value37
3,27obtained fron 38
sound
3,88 power level. 39
4,33
A (5) mm 525 725 925 1125 1325
4Sound
Sound
Total Power
power on the
Net Heating Capacitybasis of measurements made in (4)(7)
compliance
(2)(6) dB(A)
withkWISO 3741 44
and
0,89 Eurovent 8/2. 45
2,13 46
3,29 47
3,91 48
4,36
B
5MAX
Unit inSPEED
standard configuration/execution, without optional(2)
(5)
accessories.mm 126 126 126 126 126
Water
H flow in heating mode (5) mml/s 0,04
576 0,10
576 0,16
576 0,19
576 0,21
576
6Fan
Values in compliance
Power Input with EN14511-3:2013. (1) W 10,7 19,0 20,0 29,0 33,0
7Pressure drop in heating mode kPa 8 8 33 25 32
Operating weight (2)
(5) kg 9 12 15 18 21
Values
Air flowinrate
compliance with [REGULATION (UE) N.2016/2281](1) m³/h 125 277 425 593 697
Sound
CertifiedPressure
data in EUROVENT (3) dB(A) 41 42 44 46 47
Notes:
Total capacity in cooling mode (1) kW 0,76 1,75 2,75 3,22 3,76
i-LIFE2
1Sound SLIM
Power
Room temperature / DLMO - DLRV
27 °C d.b./19 °C w.b.; Chilled water
(4)(7) dB(A)
(in/out) 7/12 °C. 080
50 170
51 270
53 320
55 370
56
Total Net Cooling Capacity (1)(6)(7) kW 0,75 1,73 2,73 3,19 3,73
2SIZE
RoomAND WEIGHT
temperature 20 °C d.b.; Hot water (in/out) 45/40 °C
Sensible capacity in cooling mode (1)
3ASound pressure level in free field on a reflective surface,(5)1 m from fan kW 0,66
mmfront and 737 1,53
937
1 m from the ground. 2,21
1137
Non -binding value 3,02
1337
obtained fron sound 3,30
power level. 1537
4Net sensible
BSound power oncooling
the basiscapacity
of measurements made in (1)(6)(7) compliance
(5) withkW
mm ISO 3741 0,65
131Eurovent 8/2. 1,51
and 131 2,19
131 2,99
131 3,27
131
5Net
HUnitlatent
in power
standard in cooling
configuration/execution, without (1)(6)(7)
optional accessories.
(5) kW
mm 0,10
579 0,22
579 0,54
579 0,20
579 0,46
579
6Max water
Values flow
in compliance with EN14511-3:2013. (1) l/s 0,04 0,08 0,13 0,15 0,18
Operating weight (5) kg 17 20 23 26 29
7Pressure
Values in compliance
Drop in cooling with [REGULATION
mode (UE) N.2016/2281](1) kPa 6 5 24 17 24
Notes:
Certified data in EUROVENT
Total capacity (heating mode) (2) kW 0,88 2,11 3,27 3,88 4,33
1 Room temperature 27 °C d.b./19 °C w.b.; Chilled water (in/out) 7/12 °C.
2Total
RoomNet Heating20Capacity kW 0,89 2,13 3,29 3,91 4,36
(2)(6)
temperature °C d.b.; Hot water (in/out) 45/40 °C
3Water
Sound flow in heating
pressure mode
level in free field on a reflective surface,(2) 1 m from fanl/s front and 0,04 0,10
1 m from the ground. 0,16
Non -binding value 0,19power level.= 0,21
obtained fron sound
4Pressure
Sound power drop onintheheating
basis ofmode
measurements made in compliance (2) kPa
with ISO 3741 and 8 Eurovent 8/2.= 8 33 25 32
5Sound Pressure
Unit in standard configuration/execution, without optional(3) dB(A)
accessories. 41 42 44 46 47
6Sound
Values Power
in compliance with EN14511-3:2013. (4)(7) dB(A) 50 51 53 55 56
7 Values in compliance with [REGULATION (UE) N.2016/2281]
SIZE AND WEIGHT
2
Certified data in EUROVENT
A (5) mm 737 937 1137 1337 1537
B (5) mm 131 131 131 131 131
H (5) mm 579 579 579 579 579
Operating weight (5) kg 17 20 23 26 29
Notes:
1 Room temperature 27 °C d.b./19 °C w.b.; Chilled water (in/out) 7/12 °C.
2 Room temperature 20 °C d.b.; Hot water (in/out) 45/40 °C
2
3 Sound pressure level in free field on a reflective surface, 1 m from fan front and 1 m from the ground. Non -binding value obtained fron sound power level.=
4 Sound power on the basis of measurements made in compliance with ISO 3741 and Eurovent 8/2.=
5 Unit in standard configuration/execution, without optional accessories.
6 Values in compliance with EN14511-3:2013.
7 Values in compliance with [REGULATION (UE) N.2016/2281]
Certified data in EUROVENT