The DSE7510(Deepsea) Controller as standard, BGC-L(Deif) optional.
Page:1/3
○
R
○
R
Introduction
A composite floor standing multi-bay control cubicle
for automatic synchronization of multiple diesel
generators set installation.
LED/LCD display
Generator control section(s)
·Charge fail
Automatic generator control module。 ·Low oil pressure
·Underspeed
Microprocessor based and fully programmable with
·Overspeed
event logging and communications if required .
·Fail to start
Features as follows:
·Low battery voltage
·High battery voltage
Pushbuttons:
·Fail to stop
·Start
·Under voltage
·Stop/reset
·Over voltage
·Auto
·Under frequency
·Manual
·Over frequency
·Mute/lamp test
·Reverse power
·CB closed
Page:2/3
○
R
○
R
Communications Dimensions
·RS232 link
·RJ45 link
·PC interface 100
Each cubicles dimension: 800(L)×1050(W)×2250(H)
Controller choice:
BGC-L
DSE7510
(optional)
(standard)
Page:3/3
®
DSEPOWER
®
SHARING
WITH
SIMPLICITY.
DSE7510 SPECIFICATION
AUTO START CONTROL MODULE
DC SUPPLY
8V to 35V continuous
CRANKING DROPOUTS
Able to survive 0V for 50mS, providing supply
was at least 10V before dropout and supply
recovers to 5V. This is achieved without the
need for internal batteries
generating sets that include non- sequence and loss of excitation. • kW on mains (utility) level
AUXILIARY RELAY OUTPUTS
electronic and electronic engines. • Mains (utility) decoupling test mode Three outputs 2A DC at supply voltage
The module also provides • Manual speed/frequency adjust Two outputs volt free 2A at 250V AC
FEATURES
• ROCOF & vector shift
excellent engine monitoring and • Electronic engine capability DIMENSIONS
• Generator load demand
protection features. • RS232 or RS485 remote 240mm x 172mm x 57mm
• Automatic hours run balancing 9.4” x 6.8” x 2.2”
communications
• Dead bus sensing
The module’s load share functions • Modbus RTU
• Existing load share line interfacing PANEL CUTOUT
include automatic synchronising • Pin number protected front panel 220mm x 160mm
(P123 required)
with built in synchroscope and programming 8.7” x 6.3”
• Direct governor & AVR
closing onto dead bus. Direct and • Exercise timer
communication CHARGE FAIL/EXCITATION RANGE
• Back-lit LCD 4-line text display
flexible outputs from the module • Volts & frequency matching 0V to 35V
• Multiple display languages
are provided to allow connection • kW and kVAr load sharing
• Voltage measurement BUILT IN GOVERNOR CONTROL
to the most commonly used speed • Manual voltage adjust Fully Isolated
• Configurable inputs (9)
governors and automatic voltage • Auto ID negotiation Minimum Load Impedence:
• Configurable outputs (5) 1000Ω
regulators (AVRs). • Automatic start Gain Volts 0V - 10V DC
BENEFITS
• Manual start Offset Volts + / - 10V DC
The module has been designed to • Sends SMS messages to
• Audible alarm
combine a maximum of 16 engineers to notify specific BUILT IN AVR CONTROL
• LED indicators
engine problems (GSM Modem Fully Isolated
generators and 16 mains (utility) • Built-in governor and AVR control Minimum Load Impedence: 1000Ω
and SIM card required)
supplies up to a maximum of 20 in • Engine history event log Gain Volts 0V - 10V DC
• On-site and remote (modem Offset Volts + / - 10V DC
one system, e.g. 16 generators • Engine protection
required) module configuration
and 4 mains (utility) supplies – • Fault condition notification to a
• In-built engine diagnostics ENCLOSURE PROTECTION
DSE7560 required to synchronise designated PC (front of module)
removes the requirement for
with the mains (utility). • Front panel mounting IP65 (with optional gasket)
service equipment IP42 (without gasket)
• PC configuration
• Full engine protection &
• Bus failure detection
The module has the ability to instrumentation without the need
• Configurable alarm timers
monitor generator under/over volts, for additional senders (Electronic
• Configurable start & stop timers
over current, generator under/over engines only)
• Automatic load transfer
frequency, under speed, over speed, • Remote monitoring of the module
• SMS alert messaging
charge fail, emergency stop, low oil using comprehensive DSE PC
• Remote monitoring
pressure, high engine temperature, software
• Magnetic pick-up
fail to start, low/high DC battery • License free PC software
• kW overload alarms
volts, fail to stop, generator short • Engine temperature alarms
circuit protection, reverse power,
TIMERS & INPUT FUNCTIONS TELEMETRY
ENVIRONMENTAL TESTING The module has been designed to include the following timers and input functions: The module gives the user full
STANDARDS telemetry facilities when using the
• Start delay timer optional communications software.
ELECTRO MAGNETIC COMPATIBILITY • Stop delay timer The module can be connected to a
BS EN 61000-6-2 • Crank timer PC using the DSE810 PC interface
EMC Generic Immunity Standard for the • Crank rest timer or by using a suitable modem.
Industrial Environment
BS EN 61000-6-4 • Engage attempt & manual crank limit timers
EMC Generic Emission Standard for the • Safety on delay timer The PC software is Microsoft
Industrial Environment • Warm up timer Windows™ based. All access into
• Cooling timer the module can be configured to
ELECTRICAL SAFETY
BS EN 60950 • Energise to stop hold timer become password protected to
Safety of Information Technology Equipment, • Pre-heat timer prevent unauthorised entry. The PC
including Electrical Business Equipment • Pre-heat bypass timer software allows the module to be
• Smoke limiting control timer controlled from a remote location.
TEMPERATURE
BS EN 60068-2-2 • Fail to stop timer
Test Ab to +70oC 60068-2-2 Hot • Over speed over-shoot timer COMMUNICATIONS
Test Ab to -30oC 60068-2-1 Cold • Breaker pulse control timers The DSE7510 has a number of
• DC battery alarm delay timers different communication capabilities:-
VIBRATION
BS EN 60068-2-6 • Sync/fail to sync timer
Ten sweeps in each of three major axes SMS Messaging
5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn BUILT-IN FUNCTIONS When the module detects an alarm
• Alternator under/over volts condition, it has the ability to send
HUMIDITY
BS 2011 part 2.1 60068-2-30 • Alternator under/over frequency an SMS message to a dedicated
Test Cb Ob Cyclic • Warning or shutdown on engine temperature, over/under speed, oil mobile number, notifying an engineer
93% RH @ 40oC for 48 hours pressure of the problem. (GSM Modem and
• Warning, shutdown or electrical trip on battery volts or over current data enabled SIM Card required).
SHOCK
BS EN 60068-2-27 • Shutdown or electrical trip on reverse power, phase rotation or short
Three shocks in each of three major axes circuit fault Remote Communications
15gn in 11mS • Earth fault shutdown When the module detects an
• Adjustable crank cycle/attempts alarm condition, it dials out to a PC
• Full remote control and telemetry notifying the user of the exact alarm
• 9 configurable digital inputs condition (modem required).
• 5 configurable and 2 fixed relay/FET outputs
OPERATION
• System lock input Building Management
The module is operated using the
• Load switching control push-button inputs The module has been designed to
front STOP/RESET, MANUAL, AUTO
• ROCOF/vector shift (mains/utility decoupling) be integrated with new and existing
and START push buttons. Three of
• Negative phase sequence building management systems.
these push buttons include an LED
• Loss of excitation
indicator. Additional push buttons
• PIN number SCADA/PC Software
provide LCD display scroll, lamp test,
The module has the ability to be
mute functionality and breaker control.
INSTRUMENTATION AND ALARMS configured and monitored from a
The DSE7510 module provides advanced metering and alarm functionality remote PC, using the DSE810
TYPICAL LOAD SHARE via the LCD display. The information can be accessed using the display scroll interface.
APPLICATION push buttons. The table below shows the instrumentation and alarm features
the module provides. EVENT LOG
The module includes a
Generator Volts L1-N, L2-N, L3-N comprehensive event log that
Generator Volts L1-L2, L2-L3, L3-L1 shows the 25 most recent alarm
G1
Generator Amps L1, L2, L3 conditions and the date and time
Generator Frequency Hz that they occurred.
Generator kVA L1, L2, L3, Total This function assists the user when
Generator kW L1, L2, L3, Total fault finding and maintaining the
G2
Generator pf L1, L2, L3, Average generating set.
Generator kVAr L1, L2, L3, Total
Generator kWh EXPANSION MODULES
Generator kVAh DSE123 Load Share Lines Interface
G3 LOAD Generator kVArh Module
Generator Phase Sequence DSE157 Relay Output Expansion
Synchroscope Display Module
Engine Speed RPM DSE545 & DSE548 Remote
Engine Oil Pressure Annunciation Expansion Module
Engine Temperature DSE130 Input Expansion Module
Plant Battery Volts
Charge Alternator Volts ELECTRONIC ENGINE
Fuel Level COMPATIBILITY
Generator Earth Current • Cummins
Bus Volts (L-L&LN) • Deutz
Bus Frequency (Hz) • John Deere
Bus Phase Sequence • MTU
Engine Hours Run • Perkins
Number of Start Attempts • Scania
Maintenance Display • Volvo
Engine ECU diagnostics information via industry standard CAN interface • Isuzu
Enhanced metering via CAN when connected to an electronic engine • Generic
• Plus additional manufacturers
®
DSE7510
P1 P2
L1
S1 S2
L2
L3
2 AMP 2 AMP
TO ALL OTHER 7510 AND 7560
TO GEN SWITCHING
FUSES FUSES
DEVICE CIRCUITRY
MSC CONNECTIONS
MAX 250 METERS
120 OHM SCREENED CABLE
51 52 53 55 54 43 44 45 46 41 42 24 22 23 39 40 56 57 47 48 49 50 33 31 32
CT1 CT2 CT3 CT4 COM U V W N SCR R S T N SCR H L
L1S1 L2S1 L3S1 NS2 L1 L2 L3 L1 L2 L3
RS485 OUTPUT C
CLOSE GEN MPU
RS232 GEN CURRENT BUS VOLTS MSC
GEN VOLTS OUTPUT D
A
FUEL LEVEL (FLEXIBLE)
P810
B
COMMON GROUND
MODULE 7510
CRANK
157
OIL PRESSURE
FUEL
SCR
WATER TEMP
3 OUTPUTS
CHG ALT
-VE
B A B A SCR H L
2 1 3 4 5 16 17 18 15 6 60 61 62 63 64 65 66 67 68 8 9 10 7 34 35 36 37 38 27 25 26
USER CONFIGURABLE +VE OUTPUT E
TO
MIN 2 AMPS MAX 20 AMP ANTI-SURGE FUSE
TO
CONNECT SCREEN AT
CONNECT SCREEN AT
GOVERNOR
GENERATOR ONLY
AVR
GENERATOR ONLY
USER CONFIGURABLE -VE INPUT D
SCREEN EARTHED
AT THIS END ONLY
UPTO32 AMPS
TO ENGINE EARTH
FUSE
02/2010 ISSUE 5
RELATED MATERIALS
TITLE PART NO’S DSE123 Data Sheet 055-044
DSE7510 Manual 057-088 Load Share Design and Commissioning 057-047
DSE7510 Installation Instructions 053-052 Guide to Synchronising and Load
DSE75xx PC Software Manual 057-078 Sharing 057-045/6
DSE7520 Data Sheet 055-066 CAN and DSE Wiring Guide 057-004
DSE7560 Data Sheet 055-067 DSE850 Comms Software Data Sheet 055-072
Data sheet Basic Gen-set Controller
multi-line 2
4921240273D
Standard functions
© DEIF A/S
Data sheet Basic Gen-set Controller
Application
The Basic Gen-set Controller is a micro-processor The generator and mains breaker types can be
based control unit containing all necessary functions for configured to be either a circuit breaker or a contactor.
protection of a gen-set and control of mains and Speed governor control and automatic voltage
generator breaker. It contains all necessary 3-phase regulation are optional functions.
measuring circuits and all values and alarms are
presented on the LCD display. Setup
Setup is easily done via a menu structure in the display
The BGC is a compact all-in-one unit designed for the (password protected, 3 levels) or via the RJ45/RS232
following applications: PC connection and the multi-line 2 Windows® based PC
utility software. The PC interface box needed for this
1. Automatic mains failure (no back sync.) operation is optional equipment for the BGC. The utility
2. Island operation software offers additional features such as monitoring
of all relevant information during commissioning, saving
Optional applications: and downloading of settings and downloading of
software updates.
3. Multiple gen-sets, load sharing
4. Peak shaving Options
5. Fixed power to mains In order to perfectly match the product solution to
6. Automatic mains failure (back sync.) specific applications, the functionality of the BGC can
be equipped with a number of available options. The
The BGC automatically carries out a cyclical self-test at options selected by the customer will be integrated in
start-up. If any errors are found, they will be displayed the standard BGC hereby securing the same user
in clear text in the display. interface unaffected by whether the application needs a
highly complex or a more basic gen-set controller.
Optional
Multiple gen-sets, load sharing (3) Peak shaving (4)
Fixed power to mains (5) Automatic mains failure (back sync.) (6)
Due to the fact that the BGC is limited to two option slots, there is an upper limit of two hardware options per
unit (except G2 + G3). Please visit www.deif.com or contact us directly for detailed information about
available options.