Millennium Power Manufacturing Corp.

Multiple Generator Automatic Synchronising System


Synchronising System Type Choice

Independent Control Cabinet Type Feature:


Functions:
1. Independent control and bus bar cabinet;
2. Paralleling function (auto-tripping, closing, auto-paralleling,
disconnection, auto-load shifting, distribution).
Safety:
1. Auto-tripping, closing;
2. Touch operation;
Independent Control Cabinet Type 3. Fully auto control, avoiding misoperation by man.
Humanized operation:
Digital humanized operation interface.

Simple Type Feature:


Functions:
Paralleling function (auto-tripping, closing, auto-paralleling,
disconnection, auto-load shifting, distribution).
Safety:
4. Auto-tripping, closing;
5. Touch operation;
6. Fully auto control, avoiding misoperation by man.
Simple Type Humanized operation:
Digital humanized operation interface.

DSE7520 Single generator no break solution

Parallel With Mains

Remark:
The DSE7510(Deepsea) Controller as standard, BGC-L(Deif) optional.

Page:1/3

R

R

Millennium Power Manufacturing Corp.

Independent Control Cabinet Type

Introduction
A composite floor standing multi-bay control cubicle
for automatic synchronization of multiple diesel
generators set installation.

Each bay has a generator control and load switching


section connected to a common bus bar.

The cubicles are manufacture with lockable hinged


front door and removable aluminium gland plates to
the top and base. Cable entry can be arranged for top
and base entry. Lifting eyes are mounted on the top
of the enclosure.

LED/LCD display
Generator control section(s)
·Charge fail
Automatic generator control module。 ·Low oil pressure
·Underspeed
Microprocessor based and fully programmable with
·Overspeed
event logging and communications if required .
·Fail to start
Features as follows:
·Low battery voltage
·High battery voltage
Pushbuttons:
·Fail to stop
·Start
·Under voltage
·Stop/reset
·Over voltage
·Auto
·Under frequency
·Manual
·Over frequency
·Mute/lamp test
·Reverse power
·CB closed

LCD display (generator set )


·Voltage
·Amperage Others display
·Frequency
Each control cubicle we installed frequency meter and
·RPM
voltage meter to monitor frequency and voltage of each
·Oil pressure
generator set easy.
·Engine temperature
·Hours run
·Battery voltage

Page:2/3

R

R

Millennium Power Manufacturing Corp.

Functions and protections: Dimensions


·Reverse power
·Dead bus sensing
·Voltage matching
·Frequency matching
·Phase angle matching
·Ramp control
·Blend control
·Circuit breaker closing
·Engine speed control

Communications Dimensions

·RS232 link
·RJ45 link
·PC interface 100
Each cubicles dimension: 800(L)×1050(W)×2250(H)

Total length of control panel:


(Numbers of generator sets +1) ×800(L)

Controller choice:

BGC-L
DSE7510
(optional)
(standard)

Page:3/3
®

DSEPOWER
®

SHARING
WITH
SIMPLICITY.
DSE7510 SPECIFICATION
AUTO START CONTROL MODULE

DC SUPPLY
8V to 35V continuous

CRANKING DROPOUTS
Able to survive 0V for 50mS, providing supply
was at least 10V before dropout and supply
recovers to 5V. This is achieved without the
need for internal batteries

MAXIMUM OPERATING CURRENT


460mA at 12V. 245mA at 24V

MAXIMUM STANDBY CURRENT


375mA at 12V. 200mA at 24V

ALTERNATOR INPUT RANGE


ELECTRONIC ENGINE CAPABILITY 15V AC (L-N) to 333V AC (L-N) absolute
maximum

ALTERNATOR INPUT FREQUENCY


50Hz - 60Hz at rated engine speed (Minimum:
15V AC L-N)

MAGNETIC PICK-UP VOLTAGE RANGE


+/- 0.5V to 70V Peak

MAGNETIC INPUT FREQUENCY


10,000 Hz (max)

START RELAY OUTPUT


The DSE7510 is an Automatic generator phase rotation error, earth LOAD SHARE FEATURES
15A DC at supply voltage
Engine Control Module, designed fault protection, loss of speed signal, • No-break transfer
to provide advanced load share fail to open, fail to close, out of sync, • Peak shaving/peak lopping FUEL RELAY OUTPUT
functionality for diesel and gas open circuit failure, negative phase • Sequential set start 15A DC at supply voltage

generating sets that include non- sequence and loss of excitation. • kW on mains (utility) level
AUXILIARY RELAY OUTPUTS
electronic and electronic engines. • Mains (utility) decoupling test mode Three outputs 2A DC at supply voltage
The module also provides • Manual speed/frequency adjust Two outputs volt free 2A at 250V AC
FEATURES
• ROCOF & vector shift
excellent engine monitoring and • Electronic engine capability DIMENSIONS
• Generator load demand
protection features. • RS232 or RS485 remote 240mm x 172mm x 57mm
• Automatic hours run balancing 9.4” x 6.8” x 2.2”
communications
• Dead bus sensing
The module’s load share functions • Modbus RTU
• Existing load share line interfacing PANEL CUTOUT
include automatic synchronising • Pin number protected front panel 220mm x 160mm
(P123 required)
with built in synchroscope and programming 8.7” x 6.3”
• Direct governor & AVR
closing onto dead bus. Direct and • Exercise timer
communication CHARGE FAIL/EXCITATION RANGE
• Back-lit LCD 4-line text display
flexible outputs from the module • Volts & frequency matching 0V to 35V
• Multiple display languages
are provided to allow connection • kW and kVAr load sharing
• Voltage measurement BUILT IN GOVERNOR CONTROL
to the most commonly used speed • Manual voltage adjust Fully Isolated
• Configurable inputs (9)
governors and automatic voltage • Auto ID negotiation Minimum Load Impedence:
• Configurable outputs (5) 1000Ω
regulators (AVRs). • Automatic start Gain Volts 0V - 10V DC
BENEFITS
• Manual start Offset Volts + / - 10V DC
The module has been designed to • Sends SMS messages to
• Audible alarm
combine a maximum of 16 engineers to notify specific BUILT IN AVR CONTROL
• LED indicators
engine problems (GSM Modem Fully Isolated
generators and 16 mains (utility) • Built-in governor and AVR control Minimum Load Impedence: 1000Ω
and SIM card required)
supplies up to a maximum of 20 in • Engine history event log Gain Volts 0V - 10V DC
• On-site and remote (modem Offset Volts + / - 10V DC
one system, e.g. 16 generators • Engine protection
required) module configuration
and 4 mains (utility) supplies – • Fault condition notification to a
• In-built engine diagnostics ENCLOSURE PROTECTION
DSE7560 required to synchronise designated PC (front of module)
removes the requirement for
with the mains (utility). • Front panel mounting IP65 (with optional gasket)
service equipment IP42 (without gasket)
• PC configuration
• Full engine protection &
• Bus failure detection
The module has the ability to instrumentation without the need
• Configurable alarm timers
monitor generator under/over volts, for additional senders (Electronic
• Configurable start & stop timers
over current, generator under/over engines only)
• Automatic load transfer
frequency, under speed, over speed, • Remote monitoring of the module
• SMS alert messaging
charge fail, emergency stop, low oil using comprehensive DSE PC
• Remote monitoring
pressure, high engine temperature, software
• Magnetic pick-up
fail to start, low/high DC battery • License free PC software
• kW overload alarms
volts, fail to stop, generator short • Engine temperature alarms
circuit protection, reverse power,
TIMERS & INPUT FUNCTIONS TELEMETRY
ENVIRONMENTAL TESTING The module has been designed to include the following timers and input functions: The module gives the user full
STANDARDS telemetry facilities when using the
• Start delay timer optional communications software.
ELECTRO MAGNETIC COMPATIBILITY • Stop delay timer The module can be connected to a
BS EN 61000-6-2 • Crank timer PC using the DSE810 PC interface
EMC Generic Immunity Standard for the • Crank rest timer or by using a suitable modem.
Industrial Environment
BS EN 61000-6-4 • Engage attempt & manual crank limit timers
EMC Generic Emission Standard for the • Safety on delay timer The PC software is Microsoft
Industrial Environment • Warm up timer Windows™ based. All access into
• Cooling timer the module can be configured to
ELECTRICAL SAFETY
BS EN 60950 • Energise to stop hold timer become password protected to
Safety of Information Technology Equipment, • Pre-heat timer prevent unauthorised entry. The PC
including Electrical Business Equipment • Pre-heat bypass timer software allows the module to be
• Smoke limiting control timer controlled from a remote location.
TEMPERATURE
BS EN 60068-2-2 • Fail to stop timer
Test Ab to +70oC 60068-2-2 Hot • Over speed over-shoot timer COMMUNICATIONS
Test Ab to -30oC 60068-2-1 Cold • Breaker pulse control timers The DSE7510 has a number of
• DC battery alarm delay timers different communication capabilities:-
VIBRATION
BS EN 60068-2-6 • Sync/fail to sync timer
Ten sweeps in each of three major axes SMS Messaging
5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn BUILT-IN FUNCTIONS When the module detects an alarm
• Alternator under/over volts condition, it has the ability to send
HUMIDITY
BS 2011 part 2.1 60068-2-30 • Alternator under/over frequency an SMS message to a dedicated
Test Cb Ob Cyclic • Warning or shutdown on engine temperature, over/under speed, oil mobile number, notifying an engineer
93% RH @ 40oC for 48 hours pressure of the problem. (GSM Modem and
• Warning, shutdown or electrical trip on battery volts or over current data enabled SIM Card required).
SHOCK
BS EN 60068-2-27 • Shutdown or electrical trip on reverse power, phase rotation or short
Three shocks in each of three major axes circuit fault Remote Communications
15gn in 11mS • Earth fault shutdown When the module detects an
• Adjustable crank cycle/attempts alarm condition, it dials out to a PC
• Full remote control and telemetry notifying the user of the exact alarm
• 9 configurable digital inputs condition (modem required).
• 5 configurable and 2 fixed relay/FET outputs
OPERATION
• System lock input Building Management
The module is operated using the
• Load switching control push-button inputs The module has been designed to
front STOP/RESET, MANUAL, AUTO
• ROCOF/vector shift (mains/utility decoupling) be integrated with new and existing
and START push buttons. Three of
• Negative phase sequence building management systems.
these push buttons include an LED
• Loss of excitation
indicator. Additional push buttons
• PIN number SCADA/PC Software
provide LCD display scroll, lamp test,
The module has the ability to be
mute functionality and breaker control.
INSTRUMENTATION AND ALARMS configured and monitored from a
The DSE7510 module provides advanced metering and alarm functionality remote PC, using the DSE810
TYPICAL LOAD SHARE via the LCD display. The information can be accessed using the display scroll interface.
APPLICATION push buttons. The table below shows the instrumentation and alarm features
the module provides. EVENT LOG
The module includes a
Generator Volts L1-N, L2-N, L3-N comprehensive event log that
Generator Volts L1-L2, L2-L3, L3-L1 shows the 25 most recent alarm
G1
Generator Amps L1, L2, L3 conditions and the date and time
Generator Frequency Hz that they occurred.
Generator kVA L1, L2, L3, Total This function assists the user when
Generator kW L1, L2, L3, Total fault finding and maintaining the
G2
Generator pf L1, L2, L3, Average generating set.
Generator kVAr L1, L2, L3, Total
Generator kWh EXPANSION MODULES
Generator kVAh DSE123 Load Share Lines Interface
G3 LOAD Generator kVArh Module
Generator Phase Sequence DSE157 Relay Output Expansion
Synchroscope Display Module
Engine Speed RPM DSE545 & DSE548 Remote
Engine Oil Pressure Annunciation Expansion Module
Engine Temperature DSE130 Input Expansion Module
Plant Battery Volts
Charge Alternator Volts ELECTRONIC ENGINE
Fuel Level COMPATIBILITY
Generator Earth Current • Cummins
Bus Volts (L-L&LN) • Deutz
Bus Frequency (Hz) • John Deere
Bus Phase Sequence • MTU
Engine Hours Run • Perkins
Number of Start Attempts • Scania
Maintenance Display • Volvo
Engine ECU diagnostics information via industry standard CAN interface • Isuzu
Enhanced metering via CAN when connected to an electronic engine • Generic
• Plus additional manufacturers
®

DSE7510

FROM AUTOMATIC MCCB


GENERATOR AUTOMATIC ACB TO
LOAD
or CONTACTOR
CT’s 1 AMP OR 5 AMP 3 or 4 POLE
SECONDARY
PROTECTION CLASS

P1 P2
L1

S1 S2

L2

L3

2 AMP 2 AMP
TO ALL OTHER 7510 AND 7560
TO GEN SWITCHING

FUSES FUSES
DEVICE CIRCUITRY

MSC CONNECTIONS
MAX 250 METERS
120 OHM SCREENED CABLE

THE FIRST AND LAST


UNITS MSC MUST BE FITTED
MPU WITH A 120 OHM RESISTOR
ACROSS H AND L

51 52 53 55 54 43 44 45 46 41 42 24 22 23 39 40 56 57 47 48 49 50 33 31 32
CT1 CT2 CT3 CT4 COM U V W N SCR R S T N SCR H L
L1S1 L2S1 L3S1 NS2 L1 L2 L3 L1 L2 L3
RS485 OUTPUT C
CLOSE GEN MPU
RS232 GEN CURRENT BUS VOLTS MSC
GEN VOLTS OUTPUT D
A
FUEL LEVEL (FLEXIBLE)

P810
B
COMMON GROUND

MODULE 7510
CRANK

157
OIL PRESSURE
FUEL

SCR
WATER TEMP

3 OUTPUTS
CHG ALT

PLANT +VE GOVERNOR AVR ENGINE ECU


BATTERY 9 INPUTS
O/P O/P
+VE

-VE

B A B A SCR H L

2 1 3 4 5 16 17 18 15 6 60 61 62 63 64 65 66 67 68 8 9 10 7 34 35 36 37 38 27 25 26
USER CONFIGURABLE +VE OUTPUT E

USER CONFIGURABLE +VE OUTPUT F

USER CONFIGURABLE +VE OUTPUT G


USER CONFIGURABLE -VE INPUT G
USER CONFIGURABLE -VE INPUT A
REMOVE LINK FOR REMOTE EM STOP

USER CONFIGURABLE -VE INPUT E


TO CRANK SOLENOID MAX 16AMP OUTPUT B
TO FUEL SOLENOID MAX 16AMP OUTPUT A

USER CONFIGURABLE -VE INPUT H


CHARGE ALTERNATOR

USER CONFIGURABLE -VE INPUT B


FUEL TEMP
HIGH COOLANT TEMP
LOW OIL PRESSURE

USER CONFIGURABLE -VE INPUT F


USER CONFIGURABLE -VE INPUT C

USER CONFIGURABLE -VE INPUT I

TO
MIN 2 AMPS MAX 20 AMP ANTI-SURGE FUSE

TO
CONNECT SCREEN AT

CONNECT SCREEN AT

GOVERNOR
GENERATOR ONLY

AVR
GENERATOR ONLY
USER CONFIGURABLE -VE INPUT D

SCREEN EARTHED
AT THIS END ONLY
UPTO32 AMPS

TO ENGINE EARTH
FUSE

120 R TERMINATING RESISTOR


BATTERY +VE(12 OR 24 VDC )

MAY BE REQUIRED EXTERNALLY


SEE ENGINE MANUFACTURERS
LITERATURE
BATTERY -VE

02/2010 ISSUE 5

RELATED MATERIALS
TITLE PART NO’S DSE123 Data Sheet 055-044
DSE7510 Manual 057-088 Load Share Design and Commissioning 057-047
DSE7510 Installation Instructions 053-052 Guide to Synchronising and Load
DSE75xx PC Software Manual 057-078 Sharing 057-045/6
DSE7520 Data Sheet 055-066 CAN and DSE Wiring Guide 057-004
DSE7560 Data Sheet 055-067 DSE850 Comms Software Data Sheet 055-072
Data sheet Basic Gen-set Controller
multi-line 2
4921240273D

Standard functions

Automatic mains failure Engine control

• Engine start up • Start preparation


• From mains to generator supply • Start/stop sequences
at a mains failure • Fuel solenoid selection (coil
• From generator to mains supply type)
at mains return

Island operation Protection (ANSI)

• Semi-automatic control of the • Overcurrent, 2 levels (51)


gen-set • Reverse power (32)
• Semi-automatic control of the • 3 configurable VDO inputs
breakers • 5 configurable binary inputs
DEIF A/S

Time dependent start/stop Generator and mains breaker

• Automatic gen-set and breaker • Contactor (constant signal)


control • Circuit breaker (400 ms pulse)
• 8 different start/stop commands

© DEIF A/S
Data sheet Basic Gen-set Controller
Application
The Basic Gen-set Controller is a micro-processor The generator and mains breaker types can be
based control unit containing all necessary functions for configured to be either a circuit breaker or a contactor.
protection of a gen-set and control of mains and Speed governor control and automatic voltage
generator breaker. It contains all necessary 3-phase regulation are optional functions.
measuring circuits and all values and alarms are
presented on the LCD display. Setup
Setup is easily done via a menu structure in the display
The BGC is a compact all-in-one unit designed for the (password protected, 3 levels) or via the RJ45/RS232
following applications: PC connection and the multi-line 2 Windows® based PC
utility software. The PC interface box needed for this
1. Automatic mains failure (no back sync.) operation is optional equipment for the BGC. The utility
2. Island operation software offers additional features such as monitoring
of all relevant information during commissioning, saving
Optional applications: and downloading of settings and downloading of
software updates.
3. Multiple gen-sets, load sharing
4. Peak shaving Options
5. Fixed power to mains In order to perfectly match the product solution to
6. Automatic mains failure (back sync.) specific applications, the functionality of the BGC can
be equipped with a number of available options. The
The BGC automatically carries out a cyclical self-test at options selected by the customer will be integrated in
start-up. If any errors are found, they will be displayed the standard BGC hereby securing the same user
in clear text in the display. interface unaffected by whether the application needs a
highly complex or a more basic gen-set controller.

Single line application diagrams


Standard
Automatic mains failure (no back sync.) (1) Island operation (2)

Optional
Multiple gen-sets, load sharing (3) Peak shaving (4)

Fixed power to mains (5) Automatic mains failure (back sync.) (6)

DEIF A/S Page 2 of 7


Data sheet Basic Gen-set Controller
Available options

Due to the fact that the BGC is limited to two option slots, there is an upper limit of two hardware options per
unit (except G2 + G3). Please visit www.deif.com or contact us directly for detailed information about
available options.

Option Description Type Note


A Loss of mains protection package
A1 over- and undervoltage (generator and busbar/mains) (27/59)
over- and underfrequency (generator and busbar/mains) (81)
Software option
vector jump (78)
df/dt (ROCOF) (81)
A2 over- and undervoltage (generator and busbar/mains) (27/59)
over- and underfrequency (generator and busbar/mains) (81) Software option
df/dt (ROCOF) (81)
A3 over- and undervoltage (generator and busbar/mains) (27/59)
over- and underfrequency (generator and busbar/mains) (81) Software option
vector jump (78)
B Generator/busbar/mains protection package
B1 over- and undervoltage (generator and busbar/mains) (27/59)
Software option
over- and underfrequency (generator and busbar/mains) (81)
C Generator add-on protection package
C1 over- and undervoltage (generator) (27/59)
over- and underfrequency (generator) (81)
overload (32)
peak current
Software option
current unbalance
voltage asymmetry
reactive power import (excitation loss)
reactive power export (overexcitation)
D Voltage/var/PF control
D1 Selection between:
Selection between:
constant voltage control (stand-alone)
D1A: Analogue control
constant reactive power control (parallel with mains) Software option
D1R: Relay control
constant power factor control (parallel with mains)
Requires option M14
reactive load sharing (island paralleling with other generators)
D2 constant voltage (stand-alone/sync.) Software option
F Analogue transducer outputs
F1 2 transducer outputs, 0...20mA or 4...20mA Hardware
option
F2 4 transducer outputs, 0...20mA or 4...20mA Two boards – no other
Hardware
hardware option
option
available
G Control functions
G1 2 load dependent relays Hardware
Requires option M14
option
G2 synchronising with analogue lines Hardware Two other hardware
option options available
G3 load sharing and synchronising Hardware Two other hardware
option options available
H Serial communication
H1 Can-open Hardware
option
H2 Modbus RTU Hardware
option
H3 Profibus DP Hardware
option
H4 CAT CCM Hardware
option
H5 Can-bus engine communication for: Hardware
MTU MDEC option
Detroit Diesel DDEC
Deutz EMR
John Deere JDEC
Volvo Penta D12 AUX
H6 Cummins ECM (RS485) engine communication Hardware
option
J Cables
J5 BGC converter box kit Other
K1 Designer’s reference handbook (hard copy) Other

DEIF A/S Page 3 of 7


Data sheet Basic Gen-set Controller
Available options (continued from page 3)

Option Description Type Note


M Configurable I/O extension cards
M13 7 binary inputs, configurable Hardware
option
M14 4 relay outputs Hardware
option
M15 4 analogue inputs, configurable, 4...20mA Hardware
option
Y Display layout
Y1 BGC display for island operation (no mains breaker) Hardware
option

(ANSI# as per IEEE Std C37.2-1996(R2001) in parenthesis).

DEIF A/S Page 4 of 7