Trane - NV Series and P Series Catalog - 05 2021
Trane - NV Series and P Series Catalog - 05 2021
and P-Series
Catalog
Winter 2021
Doing Our Part
to Create a Better Future
Core Environmental Policy
The Mitsubishi Electric Group promotes sustainable development and commits to protecting and restoring the
global environment through technology, all business activities, and our employees’ actions.
Comfort Ecology
Heat Pump Principle (When Heating) <Case of COP of 5.0>
Refrigerant and Heat Circulation
Faster start-up and more Fewer On/Off operations
1. Inverter stable indoor temperature than with non-inverter 3,600 BTU/H
Electrical Compressor compresses
than non-inverter units. systems.
Energy Output the refrigerant which
raises the temperature
When enabled, the sensor 176° F
The sensor detects the
detects the location of
number of people in the 68° F
people within a space.
space. When the space is Compressor
Customized airflow settings
2. 3D i-see Sensor® detected to be vacant, the Outdoors Indoors
to move air directly toward
unit enters Energy Saving
or away from individuals
operation or may be set to
provides personalized
automatically turn off.
14,400 BTU/H 18,000 BTU/H
comfort. Heat absorbed Heat output
Evaporator Condenser
from the air
Expansion Valve
Achieves high heating
capacity even at low Expands the geographical
3. Flash Injection temperatures plus faster region covered by heat 86° F
41° F 122° F Heat
start-up compared to pump heating systems.
conventional inverters. Expansion valve expands
refrigerant to lower the temperature
Contents
Product Overview
Product Lineup...................................................................................................................6 - 11
Quality and Testing.........................................................................................................12 - 13
Inverter Technologies......................................................................................................14 - 15
Features............................................................................................................................16 - 29
Nv-Series
Nv-Series...........................................................................................................................30 - 73
P-Series
P-Series........................................................................................................................... 74 - 111
Multi-Zone Series
Nv-Series : Multi-zone Outdoor Units.........................................................................112 - 119
Conditions
Conditions for Specifications...............................................................................................120
Piping Installation........................................................................................................122 - 126
Explanation of Terminology.................................................................................................127
Appendix
Installation in Cold Regions.........................................................................................129 - 130
System Control..............................................................................................................131 - 132
Optional Parts..............................................................................................................134 - 155
Additional Information...............................................................................................156 - 161
Correction Factors........................................................................................................162 - 165
External Dimensions.....................................................................................................166 - 176
Nv-Series Model Reference Guide
N T X S PH 1 2 A 1 1 2 A *
Family
N = Nv-Series Minor Service Change
(parts change, no
Brand function/spec change)
T = Trane Major Change
(compressor, software,
Function/Type related to features/
X = Heat Pump (INVERTER) performance etc)
V = Indoor matched with
Voltage
Various Outdoor
1 = 115V, 1ph
Y = Cooling Only (INVERTER)
2 = 208/230V,1ph
Unit Configuration Outdoor Max Number of Zones
Outdoor:
1 = Single-zone
S = Single-zone Outdoor
2+ = Multi-zone
M = Multi-zone Outdoor
Indoor: UL/Non-UL
A = Convertible Air Handler 1 = US / UL Rated
C = Cassette 2’x2’ 2 = Non US/ Non-UL Rated
D = Horizontal-ducted Generation Change
F = Floor Unit A, B, C
U = EZ FIT® Ceiling Cassette Capacity (Nominal)
W = High-wall Unit BTU/H (X 1,000)
Series 06 = 6,000
EL = Entry Level 09 = 9,000
KH = Non-highwall Hyper-heating 12 = 12,000
KS = Non-highwall Series 15 = 15,000
MT = Mid Tier 18 = 18,000
MX = Standard Multi-zone 24 = 24,000
PH = Hyper-heating 30 = 30,000
ST = Standard Line 36 = 36,000
SH = Standard Line Hyper-heating 42 = 42,000
PB = Hyper-heating with Base Heater 48 = 48,000
PF = Hyper-heating for Floor Standing 60 = 60,000
1. Designed for residential applications 2. User-friendly zoned cooling and heating solutions for single- or multi-room applications or the whole home 3. Hyper-heating INVERTER-
driven outdoor units can provide high heating performance at lower ambient temperatures 4. Many ENERGY STAR® certified models
6 Product Overview
P-Series Model Reference Guide
Indoor Unit
TP KA0A 0121KA70 A
Brand Name Minor Design Update
T = Trane A = 1st Gen
B = 2nd Gen
Model Family
Future Use
P = P-Series
Outdoor Unit
TR UZ A 0121L A8 0N A
Minor Design Update
Brand Name A = 1st Gen
TR = Trane B = 2nd Gen
Configuration Coil Coating
U = Single Outdoor Unit N = Standard no coating
Unit Type B = Seacoast Protection
Z = Heat Pump Future Use
Y = Cooling Only
Heating Generation Code
A = Standard
H = Hyper-heat Control Type
Capacity (BTU/H)
012 = 12,000 Chassis Generation
018 = 18,000
024 = 24,000
030 = 30,000 Voltage
036 = 36,000 1 = 208/230V,1ph
042 = 42,000 0 = 115V, 1ph
Product Overview 7
Nv-Series Model Reference Guide
6,000 9,000 12,000 15,000 18,000 24,000 30,000 36,000
Model Name
BTU/H BTU/H BTU/H BTU/H BTU/H BTU/H BTU/H BTU/H
NTXWPH Model
• • • • •
MSZ-EF Model
• • • •
W·S·B W·S·B W·S·B W·S·B
*1 *1 *1 *1
NTXWST Model
• *1
• • • • • • •
NTXWMT Model
• • • • •
Mounted
Wall
*2 *2 *2 *2 *2
• *2
• *2
NTXWEL Model
• *2
• *2
• *2
• *2
• *2
• *2
• *2
• *2
• *2
• *2
• *2
NTXFKS Model
• • • •
Mounted
Floor
NTXUKS Model
• • •
Cassette
EZ FIT®
Ceiling
NTXAMT Model
Multi-position
Air Handler
• • • • •
NTXCKS Model
• • • •
Cassette
Ceiling
*2
NTXDKS Model
Horizontal
• • • •
Ducted
06/09/12/15/18/24
NTXMPH36A142** *3 WPH
up to 4 indoor units 06/09/12/15/18 CKS DKS
36,000 BTU/H MSZ-EF FKS UKS 09/12/15 09/12/15/18 AMT
[1-phase] 09/12/15/18 09/12/15/1 09/12/18 TPLA-A12/18/ TPEAD-A12/18/ 12/18/24/30/36
NTXWST 24/30/36 24/30/36
06/09/12/15/18/24
NTXMPH42A152** *3 WPH
up to 5 indoor units 06/09/12/15/18 CKS DKS
42,000 BTU/H MSZ-EF FKS UKS 09/12/15 09/12/15/18 AMT
[1-phase] 09/12/15/18 09/12/15/18 09/12/18 TPLA-A12/18/ TPEAD-A12/18/ 12/18/24/30/36
NTXWST 24/30/36 24/30/36
06/09/12/15/18/24
NTXMMX48A182** *3 WPH
up to 8 indoor units 06/09/12/15/18 CKS DKS
48,000 BTU/H MSZ-EF FKS UKS 09/12/15 09/12/15/18 AMT
[1-phase] 09/12/15/18 09/12/15/18 09/12/18 TPLA-A12/18/ TPEAD-A12/18/ 12/18/24/30/36
NTXWST 24/30/36 24/30/36
06/09/12/15/18/24
*3 The number of indoor units are limited when connected to TPLA. For more information, please refer to pg.85-86
The number of ducted models (AMT, DKS, TPEAD) connectible may be limited based on the outdoor unit and combination - refer to the compatibility charts.
Product Overview 9
P-Series
Cooling Only Models (TRUY)
12,000 18,000 24,000 30,000 36,000 42,000
Model Name
BTU/H BTU/H BTU/H BTU/H BTU/H BTU/H
TPLA Model
· · · · · ·
Four-way
Ceiling
Cassette
TPKA Model
Wall-mounted
· · · · ·
TPVA Model
Multi-position
Air Handler
· · · · · ·
TPEAD Model
Horizontal-ducted
· · · · · ·
TPCA Model
Ceiling-suspended
· · · ·
Heat Pump Models (TRUZ)
12,000 18,000 24,000 30,000 36,000 42,000
Model Name
BTU/H BTU/H BTU/H BTU/H BTU/H BTU/H
TPLA Model
· · · · · ·
Four-way
Ceiling
Cassette
TPKA Model
Wall-mounted
· · · · ·
TPVA Model
Multi-position
Air Handler
· · · · · ·
TPEAD Model
Horizontal-ducted
· · · · · ·
TPCA Model
Ceiling-suspended
· · · ·
10 Product Overview
Hyper-Heating Models (TRUZH)
Model Name 24,000 BTU/H 30,000 BTU/H 36,000 BTU/H 42,000 BTU/H
TPLA Model
· · · ·
Four-way
Ceiling
Cassette
TPKA Model
Wall-mounted
· · ·
TPVA Model
Multi-position
Air Handler
· · · ·
TPEAD Model
Horizontal-ducted
· · · ·
TPCA Model
Ceiling-suspended
· · · ·
Product Overview 11
Quality and Testing
Quality First. Always.
Cutting edge technologies and uncompromising commitment to quality and reliability have made us one of the
world’s most trusted brands in air conditioning and refrigeration equipment and service.
Development
Operating Tests in Harsh Conditions
Harsh environmental conditions of cold
regions are simulated for the development
of our air conditioners. This is another reason
customers in severely cold regions rely on us
for comfortable heating.
Combustion Test
Products are subjected to a wide range of tests
including combustion testing, all to confirm
safe operation under a variety of conditions.
Combustion testing is done by assuming
accidental firing and replicating abnormal
conditions that cause breakage of pressure
components.
Explosion-proof chamber
Shock Resistance
On the assumption of many different kinds
of logistics environments in the world,
we perform drop/strength tests, transport
vibration tests, and many other product
checks to assure that the quality and
performance are maintained when the
product reaches the user’s home.
12 Product Overview
Waterproof and Corrosion Test Operation Noise Test
Since the outdoor unit is subject to rain, wind, and Operation noise tests are performed in an anechoic
corrosive substances, potential problems are checked chamber with an extremely low 10 dB(A) of
by tests such as showering the unit for a certain background noise. This is just one of the ways we
amount of time and increasing protection to ensure our customers enjoy extremely quiet air
enhance the lifespan of the unit. conditioners with a minimum operation noise of
19 dB(A) (sound pressure level).
Anechoic chamber
Design
Production
Each and every unit is checked and
double-checked by experienced professionals
Every air conditioner goes through a rigorous
electrical inspection on the manufacturing line. In
final testing, our experienced inspectors listen for
even the faintest operation noise to detect any defect.
Product Overview 13
INVERTER Technologies
Our Promise: Mitsubishi Electric inverters ensure superior performance including the optimum control of
operation frequency. As a result, optimum power is applied in all heating/cooling ranges and maximum comfort
is achieved while consuming minimal energy. Fast, comfortable operation and amazingly low running cost —
that’s the Mitsubishi Electric promise.
Economic Operation
Impressively low operating cost is a key advantage of inverter air conditioners. We’ve combined advanced
inverter technologies with cutting edge electronics and mechanical technologies to achieve a synergistic effect
that enables improvements in heating/cooling efficiency. Better performance and lower energy consumption are
the result.
True Comfort
Below is a comparison of air conditioner operation control with and without an inverter.
On/Off operation
On/Off of compressor
operation of compressor Optimum control
Optimum of frequency
control of frequency
Non-inverter air conditioner
Non-inverter air conditioner Inverter air conditioner
Inverter air conditioner
temperature
roomroom
keepskeeps temperature keeps pre-set
keeps temperature
roomroom
pre-set temperature
Change in room
Change in room
temperature
temperature Full power
Full power Change in room
Change in room
temperature
temperature
Minimum powerpower
Minimum
temperature
temperature
consumption
consumption
temperature
temperature
Preset
Preset
Preset
Preset
ON ON OFF OFFON ON ON
OFF OFF ON
Compressor operation
Compressor operation Time Time Compressor operation
Compressor operation Time Time
The compressors of air conditioners without an inverter start and stop repeatedly in order to maintain the
preset room temperature. This repetitive on/off operation uses excessive electricity and compromises room
comfort. The compressors of air conditioners equipped with an inverter run continuously; the inverter quickly
optimizing the operating frequency according to changes in room temperature. This ensures energy-efficient
operation and a more comfortable room.
POINT 1 Quick & Powerful 2
POINT Room Temperature Maintained
Increasing the compressor motor speed by controlling the The compressor motor operating frequency and the change
operation frequency ensures powerful output at start-up, of room temperature are monitored to calculate the most
brings the room temperature to the comfort zone faster efficient waveform to maintain the room temperature in the
than units not equipped with an inverter. Hot rooms comfort zone. This eliminates the large temperature swings
are cooled and cold rooms are heated faster and more common with non-inverter systems and guarantees
efficiently. a pleasant, comfortable environment.
Key Technologies
Our Rotary Compressor Room Temperature Maintained
Our rotary compressors use our original Poki-Poki Motor Our scroll compressors are equipped with an advanced
and Heat Caulking Fixing Method to achieve a frame compliance mechanism that allows self-adjustment of
compact-high-efficiency unit. They are designed to be the position of the orbiting scroll according to pressure load
used in various residential and commercial applications. and the accuracy of the fixed scroll position. This minimizes
In addition, the Divisible Middle Plate production method gas leakage in the scroll compression chamber, maintains
realizes even more size and weight reductions while cooling capacity, and reduces power loss.
increasing capacity and meeting energy efficiency needs.
14 Product Overview
More Advantages With Our Products
Joint Lap DC Motor Room Temperature Maintained
Mitsubishi Electric has developed The inverter monitors the varying compressor motor
a unique motor, called the frequency and creates the most efficient waveform for
Poki-Poki Motor in Japan, the motor speed. This results in improving operating
manufactured using a joint lapping efficiency at all speed ranges, using less power, and
technique. This innovative motor reducing annual electricity costs.
operates based on a high-density, Smooth Wave Pattern Sine-wave drive soft PWM
Magnetic Flux Vector Sine Wave Drive PAM (Pulse Amplitude Modulation)
This drive device is a microprocessor that converts PAM is a technology controlling the current
the compressor motor’s electrical current waveform waveform to resemble the supply voltage wave
from a conventional waveform to a sine wave resulting in reduced loss and more efficient
(180°conductance) to achieve higher efficiency by electricity use. PAM control effectively utilizes
raising the motor winding utilization ratio and 98% of the input power supply.
reducing energy loss reliability.
Without PAM Control With PAM Control
Supply
voltage
Reluctance DC Rotary Time
Neodymium
Compressor DC Compressor magnets
Current Time
Motor Rotor
Powerful neodymium
magnets used in the
Power increased
Merits of PAM Control
reluctance DC motor Efficient voltage increase
realizes increased power
Fixed scroll
Heat Compressor
Leakage loss (minimum)
exchanger
Frame can
move in direction Thrust gas power (minimum)
of axis Power Heat
Thrust friction loss (minimum) receiver exchanger
LEV1 LEV2
Secondary back-pressure
chamber minimizes thrust
friction loss Grooved piping
Substantial
reduction in Grooved Piping
leakage and
friction loss Primary back-chamber minimizes
leakage loss High-performance grooved piping
Frame Cradle scroll is used in heat exchangers to
Pipe Image
increase the heat exchange area. Cross Sectional View
Product Overview 15
Features
for Nv-Series
The WPH Model comes equipped with a 3D i-see Indirect Airflow Direct Airflow
Sensor®, an infrared-ray sensor that measures The Indirect Airflow setting diverts The Direct Airflow setting blows
temperatures at different positions throughout the airflow away from people within conditioned air toward people
the space. within the space.
space. While scanning the area from left to right,
eight vertically arranged sensor elements analyze
the room temperature in three dimensions. Based on
temperature readings, the sensor detects the location
of people in the room. This technology enables
the user to personalize comfort by selecting their
preferred airflow setting. Absence Detection
The sensors detect whether there are people in the room. When no one is
in the area, the unit automatically switches to Energy Saving Mode.
Sensor with
eight elements
8 × 94 areas When the 3D i-see Sensor detects an unoccupied room, the power
consumption reduces by ~10% after 10 minutes and further decreases by
Sensor measures while ~20% after 60 minutes.
moving from the left to right
Divided into 94
16 Product Overview
Determines Occupancy Room occupancy energy save mode
Cooling Mode
Product Overview 17
Energy-Saving
Econo Cool Mode Demand Function (On site Adjustment)
Econo Cool is an intelligent temperature control Based on the signal input, energy consumption can be
feature that adjusts the amount of air directed reduced up to 100% of the typical consumption. The
towards the body based on discharge air temperature. demand function can be activated by a commercially
The set point can be raised by 4° F without any loss available timer or an on/off switch added to the
in comfort, achieving an additional 20% energy CNDM connector (optional) on the outdoor unit
efficiency. control board.
(Function only available during manual cooling operation.) [Example: P-Series]
Limit energy consumption by changing the settings of SW7-1, SW1 and SW2 on the
Conventional Econo Cool control board of the outdoor unit. The following settings are possible.
Energy
Ambient Temperature 95° F 95° F SW7-1 SW1 SW2
Consumption
ON OFF 75%
ON
Perceived Temperature 86° F 85° F ON ON 50%
OFF ON 0% (Stop)
Econo Cool Conventional Cooling Mode
*TRUY/TRUZ outdoor only
Temperature distribution (° F)
58 61 64 68 72 75 79 82
Air Quality
Nano Platinum Filter Air Purifying Filter
This filter has a large capture area and incorporates The filter has a large capture area and deodorizes the
nanometer-sized platinum-ceramic particles that work circulating air.
to kill bacteria and deodorize the circulating air.
Fresh-air Intake
Catechin Filter The direct intake of fresh exterior air enhances indoor
Catechin is a bioflavonoid by-product of green tea air quality.
with both antiviral and antioxidant qualities. In
addition to improving air quality, it prevents the High-efficiency Filter
spreading of bacteria and viruses throughout the This high-performance filter has a much finer mesh
room, and also has an excellent deodorizing effect. compared to standard filters, and is capable of
capturing minute particulates floating in the air that
Air Filter were not previously caught.
This filter removes dust particles from the air.
Oil Mist Filter
Deodorizing Filter The oil mist filter prevents oil mist from penetrating
The catalyst coating on the honeycomb-structured the inner part of the air conditioner.
frame captures small foul-smelling substances in the
air, then breaks down the source of the odors with Long-life Filter
the power of the ozone generated in a plasma A special process for the entrapment surface improves
electrode unit. the filtering effect, making the maintenance cycle
longer than that of units equipped with conventional
Electrostatic Anti-Allergy Enzyme Filter
filters.
This filter is charged with static electricity, enabling it
to attract and capture dust particles that regular filters Filter Check Signal
cannot capture. This filter can also trap allergens The system monitors the air conditioner operating
such as bacteria and decompose them using enzymes time, and the user is notified when filter maintenance
retained in the filter. is necessary.
18 Product Overview
Air Distribution
Double Vane Vertical Vane
The double vane separates airflow into different The air outlet fin swings from side to side so that the
directions to supply air across a wide area of the room airflow reaches every part of the room.
and also reach people in two separate locations. High Ceiling Mode
In the case of rooms with high ceilings, the outlet-
Natural Flow Operation
air volume can be increased to ensure that air is
Airflow becomes more like a light breeze, and the
circulated all the way to the floor.
occupant feels more comfortable.
Low Ceiling Mode
Indirect/Direct Mode If the room has a low ceiling, the airflow volume can
This mode offers finely-tuned operation by locating be reduced for less draft.
where an occupant is in the room and sends the air
directly or indirectly according to the selected mode. Auto Fan Speed Mode
The airflow speed mode adjusts the fan speed of the
Powerful Operation indoor unit automatically according to the present
The air conditioner will automatically adjust the fan room conditions.
speed and set temperature for 15 minutes. Rapid
cooling and heating will make the room comfortable Auto Vane Control
more quickly. Outlet vanes can be moved left and right, and up
and down using the remote controller. This improved
Wide Airflow airflow control feature solves the problem of drafts.
Especially beneficial for large spaces, helping to
Horizontal Vane
ensure that the air is well circulated and reaches
The air outlet vane swings up and down so that the
every corner of the room. Select the desired airflow
airflow is spread evenly throughout the room.
pattern and it will distribute air horizontally over
a wide-ranging 150° in heating mode and 100° in
cooling mode.
ting
ing
ing
TRUY/TRUZ
ing
·
ting
Coa
oat
oat
ate
oat
Fin
Fin
Coa
om
nt C
nt C
ilic
um
um
Chr
sio
oph
hilic
ica
ica
min
min
rro
Acid
ubr
ubr
ydr
rop
Alu
Alu
i-co
in L
in L
MMX/MPH Multi-zone
aH
·
Hyd
oric
Ant
Res
Res
Silic
sph
Product Overview 19
Convenience
Smart Set
Smart Set is a simplified setting function that recalls the preferred (preset)
temperature by pressing a single button on the remote controller. Press
the same button twice in repetition to immediately return to the previous
temperature setting. Using this function contributes to comfortable waste-
free operation, realizing the most suitable air conditioning settings and
saving on power consumption when, for example, leaving the room or
going to bed.
Heating Heating
70° F 65° F
Smart
Set
Auto Changeover
The air conditioner automatically switches between WPH Remote - Closed FS Remote
WPH Remote- Open
- Open
heating and cooling modes to maintain the desired
temperature.
Low-Temperature Cooling
Intelligent fan speed control in the outdoor unit
ensures optimum performance even when the outside
temperature is low.
Ampere Limit Adjustment
Dip switch settings can be used to adjust the maximum
electrical current for operation. This function is highly
recommended for managing energy costs.
*Maximum capacity is lowered with the use of this function
Auto Restart
Especially useful at the time of power outages, the
unit turns back on automatically when power is
restored.
Operation Lock (Outdoor Unit)
To accommodate specific-use applications, cooling
or heating operation can be specified when setting
the control board of the outdoor unit. A convenient
option when a system needs to be configured for
exclusive cooling or heating service.
Sleep Mode
When Sleep Mode is activated using the wireless
remote controller, it will switch to the settings
described below.
• After 30 minutes, the set temperature will
automatically change to the sleep mode set
temperature, which the user can set beforehand.
• The fan speed will immediately change to low fan
speed.
On/Off Operation Timer
Use the remote controller to set the times of turning
the air conditioner On/Off.
20 Product Overview
Weekly Timer Function
Easily set desired temperatures and operation ON/OFF times to match lifestyle patterns. Reduce wasted energy
consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting
adjustments.
Sample Operation Pattern (Winter/Heating mode)
Mon. Tues. Wed. Thurs. Fri. Sat. Sun.
AM
OFF OFF OFF OFF OFF ON 64°F ON 64°F
AM
Midday is warmer,
Automatically turned off during work hours
so the temperature is set lower
PM
PM
How
PUSH PUSH PUSH
the W
Tim
How to set
the Weekly
Timer Select the day Select the period
Ready to set
Com
PUSH
PUSH PUSH PUSH
System Control
M-NET Connection MX Connection
Units can be connected to MELANS system controllers Connection to the MX multi-split outdoor unit is
(M-NET controllers) such as the AE-200A. possible.
kumo cloud® Wireless Interface System Group Control
Along with your smart phone or tablet device, you can The same remote controller is capable of controlling
manage your system in multiple venues, such as home, the operational status of up to 16 refrigerant systems.
work and vacation locations. You can control functions
like turning on/off, fan speed, and vane direction.
Product Overview 21 21
Anytime, Anywhere Control
kumo cloud gives you the ability
to control your home’s comfort
effortlessly. Whether you’re out for
the day or out for the month, looking
to cool down or warm up, kumo cloud
gives you control from any smart
device or web browser.
Wireless Interface 2
Indoor Unit
22 Product Overview
kumo touch™
Simple Wall-mounted design controllers can be installed anywhere with large, back lit, easy to read display. Both
the controller and receiver is enabled with RedLINK reliability.
Receiver
Indoor Unit
MHK2
Controller
Product Overview 23
Wired Controllers
Simple MA Remote Controller
TAR-CT01MAU-SB
24 Product Overview
Interface Devices
Thermostat Interface
BACnet® Interface
• Allows for third-party home • Cable length: 37”
automation/building management • Allows for third-party home automation/
system to control indoor unit building management system to control
• One interface required per indoor unit indoor unit
• Compatible with remote controllers
• Dimensions: 3.74” x 2” x 0.75”
PAC-UKPRC001-CN-1
USNAP Interface
• Allows indoor units to participate in • Communication with UCM
demand response events • Communication to indoor unit
• Works with CTA 2045 DC Form • Demand Response Events
Factor Universal Communication
Modules (UCMs) • System Reset
PAC-WHS01UP-E
Product Overview 25
Features
Nv-Series
Indoor
NTXWPH(06/09/12/15/18)A112A* MSZ-EF09/12/15/18NA(W)(B)(S) NTXWST(06/09/12/15/18)A112A*
Combination
Unit
Category Icon
MX 2 zone
MX 3 zone
MX 4 zone
MX 5 zone
MX 8 zone
MX 2 zone
MX 3 zone
MX 4 zone
MX 5 zone
MX 8 zone
MX 2 zone
MX 3 zone
MX 4 zone
MX 5 zone
MX 8 zone
Out-
NTXSPH
NTXSST
door
Unit
Radiant Temperature Control
i-see (3D i-see Sensor®) • • • • • •
Sensor AREA Temperature Monitor • • • • • •
Energy
Saving
Econo Cool • • • • • • • • • • • • • • • • •
Nano Platinum Filter • • • • • • • • • • • • • • • • •
Catechin Filter
Double Vane • • • • • •
Horizontal Vane • • • • • • • • • • • • • • • • •
Functions
Indirect/Direct Airflow • • • • • •
Powerful Operation • • • • • • 24 24 24 24 24 24
Auto Restart • • • • • • • • • • • • • • • • •
Low Temperature Cooling • • • • • • • • • • • • • • • • •
Convenience Sleep Mode
26 Product Overview
Nv-Series
NTXWMT NTYWST NTXWEL
NTXWST NTYWST NTXWMT NTXFKS NTXUKS NTXAMT
(09/12/15/ (09/12/15/ (09/12/18/24)
(30/36) (30/36) 115V(09/12) (09/12/15/18) (09/15/18) (12/18/24/30/36)
18/24) 18/24) A112A*(09/12/18/24)
A112A* A112A* A111A* A112A* A112A* A112A*
A112A* A112A* A112A*
MX 2 zone
MX 3 zone
MX 4 zone
MX 5 zone
MX 8 zone
MX 2 zone
MX 3 zone
MX 4 zone
MX 5 zone
MX 8 zone
MX 2 zone
MX 3 zone
MX 4 zone
MX 5 zone
MX 8 zone
NTXSMT
NTXSMT
NTXSKS
NTXSKS
NTXSST
NTXSPF
NTXSEL
NTYSST
NTYSST
115V
• • • • • • • • • • • • • • • • • •
• • • • • • • • •
• •
• • • • • • •
24
• Opt 09-18 • Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt
• • • • • •
• • • • • • • • • • • • • • • • • •
• 18/24 • • • • • • •
• 24 •
• 24 • 18/24 • • • • • •
06-18 • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • •
•
• • • • • • • • • • • • • • • • •
• • • • • • • • • • • •
• • • • • • *1 • *1 • • • *1 • *1 • • • * 1 • *1 •
Product Overview 27
Features
Nv-Series P-Series
Combination
Category Icon
MX 2 zone
MX 3 zone
MX 4 zone
MX 5 zone
MX 8 zone
MX 2 zone
MX 3 zone
MX 4 zone
MX 5 zone
MX 8 zone
MX 3 zone
MX 4 zone
MX 5 zone
MX 8 zone
NTXSKS
NTXSKS
TRUZH
TRUY
TRUZ
Outdoor Unit
Air
Distribution
High Ceiling Mode • • • • • • • • • • • • •
Low Ceiling Mode • • • • • • •
Auto Fan Speed Mode • • • • • • • • • • • • • • • • • • •
Auto Restart • • • • • • • • • • • • • • • • • • •
Low Temperature
Cooling • • • • • • • • • • • • • • • • • • •
12H On/Off
Convenience Operation Timer
24H On/Off
Operation Timer
Weekly Timer
Self-Diagnostic
Function • • • • • • • • • • • • • • • • • • •
Failure Recall
Maintenance Function • • • • • • • • • • • • • • • • • • •
Blue Fin • • *1 • *1 • • • *1 • *1 • • *2 • *2 • *1 • *1 •
*1 Branch box units only: NTXMMX48A182**, NTXMMX60A182**, NTXMPH36A142**, NTXMPH42A152**, and NTXMMX48A182**
*2 Sea coast protection models only
28 Product Overview
P-Series
TPVA
TPKA 12/28/24/30/36 TPCA 24/30/36/42 TPEAD 12/18/24/30/36/42
12/18/24/30/36/42
MX 3 zone
MX 4 zone
MX 5 zone
MX 2 zone
MX 3 zone
MX 4 zone
MX 5 zone
MX 8 zone
TRUZH
TRUZH
TRUZH
TRUZH
TRUY
TRUY
TRUY
TRUY
TRUZ
TRUZ
TRUZ
TRUZ
Opt Opt Opt Opt Opt Opt
12 12 30/36 12 12 30/36
• • • • • • • • • • • •
• • • • • •
Opt Opt Opt Opt Opt Opt
• • • • • • • • • • • • • •
Opt Opt Opt • • • • • • • • • • • • • •
• • • • • • • • •
• • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • •
• *2 • *2 • *2 • *2 • *1 • *1 • *2 • *2 • *1 • *1 • • *2 • *2
Opt: Separate parts must be purchased.
Product Overview 29
Nv-Series
Whether for a cold spot or hot spot
or the entire home, our systems are
versatile and perfectly suited for
any cooling or heating occasion.
Nv-Series Product Lineup
Heat Pumps
A multiple model lineup to choose from, each with various outstanding features. In addition to
inverter-equipped Wall-mounted models, floor-standing and Multi-position air handlers can be selected.
Choose the best style to match usage needs.
Wall-mounted Units
Cooling Only
For applications with needs for only cooling, there are cooling-only models to choose from.
Wall-mounted Units
WST Models
Nv-Series 31
WPH Model
Deluxe Wall-mount
Heat Exchanger
Blower Wheel
Air Duct
32 Nv-Series
The WPH Model comes equipped with a 3D i-see Indirect Airflow Direct Airflow
Sensor®, an infrared-ray sensor that measures The Indirect Airflow setting diverts The Direct Airflow setting blows
temperatures at different positions throughout the airflow away from people within conditioned air toward people
the space. within the space.
space. While scanning the area from left to right,
eight vertically arranged sensor elements analyze
the room temperature in three dimensions. Based on
temperature readings, the sensor detects the location
of people in the room. This technology enables
the user to personalize comfort by selecting their
preferred airflow setting. Absence Detection
The sensors detect whether there are people in the room. When no one is
in the area, the unit automatically switches to Energy Saving Mode.
Sensor with
eight elements
8 × 94 areas When the 3D i-see Sensor detects an unoccupied room, the power
consumption reduces by ~10% after 10 minutes and further decreases by
Sensor measures while ~20% after 60 minutes.
moving from the left to right
Divided into 94
Natural Flow
The most critical aspect of comfortable airflow is that it feels natural. The Natural Flow feature is accomplished
by alternately oscillating the two vanes to simulate a light breeze.
Double Vane
Our double vane separates
the airflow in the left and
right directions to deliver
68
airflow not only across a
Gentle airflow that avoids overcooling wide area of the room, but
Direct airflow (in Cooling) also simultaneously to two
104 people in different locations.
Triple-action Filtration
Air, like water, is something we use every day unconsciously. Yet, clean, fresh air is a vital part of creating a
healthy space for humans. Healthy air is achieved with three filters: the Nano Platinum filter, the Deodorizing
filter, and the Electrostatic anti-allergy enzyme filter.
Electrostatic Anti-Allergy
Enzyme Filter Deodorizing Filter
This filter removes chemical substances such as
This filter is charged ammonia,
with static electricity,
methyl mercaptan, trimethylamine
enabling it to attractand
and capture
hydrogen dustat the nano-level
sulphide
particles that regular(1/1,000,000 of a millimeter).
filters cannot capture.
Also, it can trap allergens and bacteria and
neutralizes them using enzymes retained
in the filter.
Electrostatic Anti-Allergy
Enzyme Filter
This filter is charged with static electricity,
enabling it to attract and capture dust
particles that regular filters cannot capture.
Also, it can trap allergens and bacteria and
neutralizes them using enzymes retained
in the filter.
34 Nv-Series
H2i plus™ Hyper-Heating Performance
H2i plus™ hyper-heating heat pump technology is leading technology in the industry. The H2i plus outdoor
units produce up to 100% heating capacity down to -5° F.
Heating Capacity
SP*06 SP*09 SP*12 SP*15 SP*18
Maximum
Heating
10,500BTU/H 11,590BTU/H 14,690BTU/H 19,360BTU/H 23,000BTU/H
Capacity at
5°F (-15°C)
COP at 5°F
2.46 2.41 2.42 2.17 2.15
(-15°C)
Maximum
Heating
Capacity 8,700BTU/H 9,600BTU/H 12,300BTU/H 16,000BTU/H 19,000BTU/H
at -5°F
(-20.5°C)
COP at -5°F
2.26 2.20 2.24 2.01 2.00
(-20.5°C)
80
Capacity (%)
-13°F
-13°F
Frozen
Frozen Draindoes
Drain does
Heating Capacity
MUZ-FH
MUZ-FH *Standard
*Standard for NTXSPBmodels
for MUZ-FSxxNAH models
StandardHeat
Standard HeatPump
Pump Optional
Optional for NTXSPHmodels
for MUZ-FSxxNA models
SEER HSPF
33.1
30.5
26.1
22.0 21.0
Nv-Series 35
WPH Model Indoor Unit Outdoor Unit Remote
Controller
USNAP T-STAT
Optional Optional Optional Optional Optional Optional Optional
Heat Caulking
Fixing Method * To confirm compatibility with the MX Model multi-zone system, refer to MX Model page.
Notes:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed) 3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
4
Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
Conditions 5
Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB
6
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7
Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
36 Nv-Series
WPH Model Indoor Unit Outdoor Unit Remote
Controller
USNAP T-STAT
Optional Optional Optional Optional Optional Optional Optional
Heat Caulking
Fixing Method * To confirm compatibility with the MX Model multi-zone system, refer to MX Model page.
Notes:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed) 3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
4
Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
Conditions 5
Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB
6
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7
Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Nv-Series 37
MSZ-EF Model
Designer Series Wall-mount
Sound Level
Human
Quiet Operation hearing limits
(Extremely
Sound of
rustling
Library
interior
Quiet passenger
car interior Subway car
quiet) leaves (25mph) interior
Our advanced Quiet Mode fan speed
setting provides super-quiet operation
as low as 21dB(A) for EF09/12 models.
10dB(A) 40dB(A) 60dB(A) 80dB(A)
21dB(A)
Only
38 Nv-Series
MSZ-EF Model
Indoor Unit Remote
Controller
MSZ-EF09/12/15/18NAB* Color Options Available:
Matte Silver, Glossy Black, or Glossy White
MSZ-EF09/12/15/18NAS
For MX Connection Only*
Soft-dry Cloth is enclosed with Black models
MSZ-EF09/12/15/18NAW
Nano Electrostatic
Platinum Anti-allergy USNAP T-STAT
Optional Optional Optional Optional Optional Optional
* To confirm compatibility with the MX Model multi-zone system, refer to MX Model page.
Notes:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed) 3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
4
Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
Conditions 5
Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB
6
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7
Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Nv-Series 39
NT(X/Y)WST Model
Standard Wall-mount
SEER HSPF
24.6 23.1
21.6 20.5 20.5
Compact Design
Slim and compact indoor units provide enhanced, industry-leading performance for cooling and heating.
11- 5 /8”
9- 1 / 8”
31-7/16”
40 Nv-Series
Quiet Operation Human
Sound Level
hearing limits Sound of Library Quiet passenger
The indoor unit noise level is as low as 19dB(A) (Extremely rustling interior car interior Subway car
quiet) leaves (25mph) interior
for WST09/12 models, offering a peaceful inside
environment.
(for WST06/09/12
models)
Powerful Operation (WST24, WST30/36) Fan speed: Exclusive speed for POWERFUL mode. POWERFUL
Horizontal Vane: Set position, or downward airflow
Depending on the capacity, the unit will automatically position during AUTO setting.
adjust the fan speed and set temperature for 15
minutes. Rapid cooling and heating will make the Fan
roomspeed: Exclusive speed for POWERFUL mode. POWERFUL
comfortable quickly. Horizontal Vane: Set position, or downward airflow
position during AUTO setting.
Heating Heating
70°F 65°F
Nv-Series 41
NTYWST Model Remote
Indoor Unit Outdoor Unit
Controller
NTYWST(09/12/15)A112A*
NTYWST18A112A*
NTYSST(09/12/15)A112A* NTYSST18A112A*
Blue Nano
Fin Platinum Smart Set
USNAP
GL18 Optional Optional Optional Optional Optional Optional
Heat Caulking
T-STAT Fixing Method
Optional MSZ-GL06-18
Capacity Rated 1 BTU/H 9,000 12,000 14,000 18,000 22,500 30,700 34,600
Capacity Range Min-Max BTU/H 3,600–12,200 1,500–13,600 3,100–18,200 5,800–22,000 8,200–31,400 9,800–30,600 9,800–34,600
Cooling Power Input Rated 1 W 585 209 1,080 1,340 1,800 3,380 4,249
Moisture Removal Pints/h 1.5 2.5 2.7 2.1 5.1 9.9 11.9
Sensible Heat Factor 0.820 0.770 0.780 0.870 0.750 0.640 0.620
Capacity at 47ºF Rated BTU/H — — — — — — —
Capacity Range Min-Max BTU/H — — — — — — —
Power Input at 47ºF Rated W — — — — — — —
Heating Rated BTU/H — — — — — — —
Capacity at 17ºF
Max BTU/H — — — — — — —
Capacity at 5ºF Max BTU/H — — — — — — —
Capacity at -5ºF Max BTU/H — — — — — — —
SEER 24.6 23.1 21.6 20.5 20.5 16.0 15.1
EER 15.4 13.0 13.0 13.4 12.5 9.1 8.2
Efficiency HSPF — — — — — — —
COP — — — — — — —
ENERGY STAR® Certified Yes Yes Yes Yes Yes No No
Air Flow Rate - Cooling 145–170–237– 145–170–237– 205–272–335– 258–332–417– 388–469–544– 389–639–848– 389–639–848–
Dry CFM
(Quiet-Lo-Med-Hi-SHi) 321–399 321–399 420–533 522–646 628–738 887 887
Air Flow Rate - Cooling 109–134–201– 109–134–201– 170–237–300– 232–299–375– 347–420–487– 350–576–763– 350–576–763–
Wet CFM
(Quiet-Lo-Med-Hi-SHi) 286–364 286–364 385–498 470–581 562–661 798 798
Air Flow Rate - Heating
Dry CFM — — — — — — —
(Quiet-Lo-Med-Hi-SHi)
Sound Pressure Level
Cooling dB(A) 19–22–30–37–43 19–22–30–37–45 26–32–38–44–49 28–33–38–44–49 34–41–45–49–53 32–42–49–51 32–42–49–51
(Quiet-Lo-Med-Hi-SHi)
Indoor Unit Sound Pressure Level (Quiet-
Heating dB(A) — — — — — — —
Lo-Med-Hi-SHi)
External Static Pressure In. W.G. — — — — — — —
Condensate Lift Mechanism Max Distance In. [mm] — — — — — — —
H In. [mm] 11-5/8 [295] 11-5/8 [295] 11-5/8 [295] 12 [305] 12-13/16 [325] 14-3/8 [365] 14-3/8 [365]
Dimensions W In. [mm] 31-7/16 [798] 31-7/16 [798] 31-7/16 [798] 36-5/16 [923] 43-5/16 [1100] 46-1/16 [1170] 46-1/16 [1170]
D In. [mm] 9-1/8 [232] 9-1/8 [232] 9-1/8 [232] 9-13/16 [250] 9-3/8 [238] 11-5/8 [295] 11-5/8 [295]
Weight lbs [kg] 22 [10.0] 22 [10.0] 22 [10.0] 28 [13.0] 37 [17.0] 40 [18.0] 40 [18.0]
MCA A 7.0 7.0 9.0 14.0 17.1 21.0 21.0
MOCP A 15 15 15 15 20 25 25
H In. [mm] 21-5/8 [550] 21-5/8 [550] 21-5/8 [550] 34-5/8 [880] 34-5/8 [880] 33-7/16 [850] 33-7/16 [850]
Dimensions W In. [mm] 31-1/2 [800] 31-1/2 [800] 31-1/2 [800] 33-1/16 [840] 33-1/16 [840] 33-1/16 [840] 33-1/16 [840]
Outdoor Unit D In. [mm] 11-1/4 [286] 11-1/4 [286] 11-1/4 [286] 13 [330] 13 [330] 13 [330] 13 [330]
Weight lbs [kg] 81 [37] 81 [37] 81 [37] 121 [55] 119 [54] 126 [57] 126 [57]
Air Flow Rate (Cooling/
CFM 1229/— 1229/— 1243/— 1691/— 1769/— 1941/— 1941/—
Heating)
Cooling dB(A) 48 49 49 54 55 55 56
Sound Pressure Level
Heating dB(A) — — — — — — —
Gas (O.D.) In. [mm] 3/8 [9.52] 3/8 [9.52] 1/2 [12.7] 1/2 [12.7] 5/8 [15.88] 5/8 [15.88] 5/8 [15.88]
Diameter Liquid (O.D) In. [mm] 1/4 [6.35] 1/4 [6.35] 1/4 [6.35] 1/4 [6.35] 3/8 [9.52] 3/8 [9.52] 3/8 [9.52]
Piping Indoor Drain In. [mm] 5/8 [15.88] 5/8 [15.88] 5/8 [15.88] 5/8 [15.88] 5/8 [15.88] 5/8 [15.88] 5/8 [15.88]
Max. Length ft [m] 65 [20] 65 [20] 65 [20] 100 [30] 100 [30] 100 [30] 100 [30]
Max. Height ft [m] 40 [12] 40 [12] 40 [12] 50 [15] 50 [15] 50 [15] 50 [15]
Outdoor-Indoor5 V, ph, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Electrical
Recommended Breaker Size A 15 15 15 15 20 25 25
Refrigerant Type R410A R410A R410A R410A R410A R410A R410A
Guaranteed 14 to 115 14 to 115 14 to 115 14 to 115 14 to 115 14 to 115 14 to 115
Cooling6 ºF DB [ºC DB]
Temperature [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0]
Operation Range Heating ºF DB [ºC DB] — — — — — — —
Notes:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
at a fixed compressor speed)
5
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6
Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
42 Nv-Series
NTXWST Model Remote
Indoor Unit Outdoor Unit
Controller
NTXWST24A112A*
NTXWST(30/36)A112A*
NTXSST24A112A* NTXSST30/36A112A*
Blue Nano
Fin Platinum Smart Set
USNAP
GL18 Optional Optional Optional Optional Optional Optional
Indoor Unit NTXWST06A- NTXWST09A- NTXWST12A- NTXWST15A- NTXWST18A- NTXWST24A- NTXWST30A- NTXWST36A-
112AA 112AA 112AA 112AA 112AA 112AA 112AA 112AA
Sound Level
Human
hearing limits Sound of Library Quiet passenger
(Extremely rustling interior car interior Subway car
quiet) leaves (25mph) interior
(for WMT09/12
Econo Cool Energy-Saving Feature models)
Temperature distribution (° F)
58 61 64 68 72 75 79 82
44 Nv-Series
WMT Model
Indoor Unit Outdoor Unit Remote
Controller
NTXWMT09/12/15A112A*
NTXWMT18/24A112A*
Optional Controller
NTXSMT09/12/15/18A112A* NTXSMT24A112A*
Holder: U01A01083
Nv-Series 45
WMT 115V Model
115V Wall-mount
Sound Level
Human
hearing limits Sound of Library Quiet passenger
(Extremely rustling interior car interior Subway car
quiet) leaves (25mph) interior
(for WMT09/12
models)
Temperature distribution (° F)
58 61 64 68 72 75 79 82
46 Nv-Series
WMT 115V Model
Indoor Unit Outdoor Unit Remote
Controller
NTXSMT(09/12)A111A*
NTXWMT(09/12)A111A*
Nv-Series 47
WEL Model
16 SEER Wall-mount
Sound Level
Human
hearing limits Sound of Library Quiet passenger
(Extremely rustling interior car interior Subway car
quiet) leaves (25mph) interior
Temperature distribution (° F)
58 61 64 68 72 75 79 82
48 Nv-Series
WEL Model
Indoor Unit Outdoor Unit Remote
Controller
NTXWEL09/12A112A*
NTXWEL18/24A112A*
Optional Controller
NTXSEL(09/12)A112A* NTXSEL(18/24)A112A*
Holder: U01A01083
Nv-Series 49
FKS Model
Floor Mount
41° F
41° F
50 Nv-Series
FKS Model
Indoor Unit Outdoor Unit Remote
Controller
NTXFKS(15/18)A112A* NTXFKS(09/12)A112A*
NTXFKS(09/12/15/18) A112A*
Nv-Series 51
Konnect Series
Universal Outdoor
NTXSKS(18/24/30/36)A112A*
NTXSKS(09/12/15)A112A* NTXSKH(09/12/15/18)A112A*
AMT
System Compatibility
Outdoor Unit
9 12 15 18 24 30 36
Capacity KBTU/H
Model Type HP HP HP HP HP HP HP
CKS 2’ x 2’ cassette • • • • • • • •
Multi-position
AMT • • • • • • • • • •
Air Handler
EZ FIT® Recessed
UKS • • • • • •
Ceiling Cassette
52 Nv-Series
Hyper-heating Inverter
The Hyper-heating models provide heating even when it’s -13° F (-25° C) outdoor ambient temperature,
producing up to 100% heating capacity at 5° F (-15° C). These units offer year-round comfort even in
extreme climates.
Heating Performance at Low Temperatures
Operation guaranteed at –13° F, NTXSKH09A112A* NTXSKH12A112A*
100% heating capacity at 5° F COP at CKS DKS TPEAD UKS COP at CKS DKS TPEAD AMT UKS
Hyper-heating Konnect Series 47° F 3.90 2.80 3.80 4.10 47° F 3.40 3.90 3.90 3.80 3.80
Standard Heat Pump
Heating Capacity (%)
17° F 2.56 2.20 2.56 2.76 17° F 2.38 2.56 2.72 2.61 2.54
100% heating capacity 5° F 1.34 1.59 1.67 1.67 5° F 1.83 2.19 2.09 1.69 1.57
as low as
Heating operation 5° F (-15° C)
down to
-13° F (-25° C) NTXSKH15A112A* NTXSKH18A112A*
100% COP at CKS DKS TPEAD COP at CKS DKS TPEAD AMT UKS
47° F 2.60 2.70 3.00 47° F 2.70 3.40 3.30 3.30 3.00
17° F 1.91 2.15 2.29 17° F 2.20 2.52 2.49 2.32 2.42
-13°F
-13°F
The base heater restricts lowered capacity and Frozen
Frozen Drain
Drain does
does
Heating Capacity
100%
100% drain
drain not
not freeze
freeze
operation shutdowns caused by the drain water
freezing. This feature supports stable operation in
Heating
low-temperature environments.
-13
-13 FF -4
-4 FF 55 FF oo oo oo 19ooFF
19 32ooFF
32
Operation Guaranteed at Outside Temperature of –13° F (–25° C)
Outdoor-air
Outdoor-airTemperature
Temperature Without
WithoutBase
BaseHeater
Heater With
WithBase
BaseHeater
Heater
NTXSPH
NTXSPH *Standard
*Standardfor
forNTXSPB
NTXSPBmodels
models
Compact and Powerful CompressorStandard
StandardHeat
HeatPump
Pump Optional
Optionalfor
forNTXSPH
NTXSPHmodels
models
Manufacturing with Heat Caulking Fixing Method reduces compressor size while maintaining a high compressor
output. This technology enables the installation of a more powerful compressor in compact outdoor units. As a
result, it is possible to achieve excellent heating performance while operating in cold outdoor environments.
Reduced
TNB220F SNB220F
by 13%
Nv-Series 53
UKS Model
EZ FIT® Recessed Ceiling Cassette
Slim Design
Ceiling Recessed
The EZ FIT flush-mount design creates a more spacious feeling in the room.
The recessed-ceiling-cassette indoor unit style provides a solution when wall space
is limited or not available.
Slim Body
The units are built with a slim body (only 7-5/16”), ensuring easy
installation even when shallow ceiling cavities limit installation space. 7-5/16"
The inventive design also eliminates the need for an extra service
access panel, further reducing the required installation area.
54 Nv-Series
Auto Vane Control
Outlet vanes can be moved left and right, and up and down using the remote controller. This improved airflow
control feature eliminates drafts..
AM
OFF OFF OFF OFF OFF ON 64°F ON 64°F
AM
Midday is warmer,
Automatically turned off during work hours
so the temperature is set lower
PM
PM
How to set
the Weekly
The remote controller is equipped Timer Select the day Select the period
PUSH PUSH PUSH
with buttons that are used Ready to set
How to set
exclusively for setting the Weekly
the Weekly
Timer PUSH
Timer. Setting operation patterns is Select the day Select the period
PUSH PUSH PUSH
Ready to set
easy and quick.
PUSH
PUSH PUSH PUSH
Nv-Series 55
Easy Installation
Industry Leading Slim Body
The EZ FIT® installs between standard joists that Within
span 16 inches on center. There is no need for large 16 inches
scale construction, such as the cutting of the joist.
Secure one side Push the unit to one side Move unit to the center
Secure the opposite side
56 Nv-Series
UKS Model
Indoor Unit Outdoor Unit Remote
Controller
NTXUKS(09/15/18)A112A*
NTXSKS09/12A112A* NTXSKS18A112A*
Air Purifying
Weekly Wi-Fi 10°C
Sleep
Timer Interface
Optional Optional Optional Optional Optional
Nv-Series 57
UKS Model
Indoor Unit Outdoor Unit Remote
Controller
NTXUKS(09/15/18)A112A*
NTXSKH(09/12/18)A112A*
Air Purifying
Weekly Wi-Fi 10°C
Sleep
Timer Interface
Optional Optional Optional Optional Optional
58 Nv-Series
AMT Model
Multi-position Air Handler
The Multi-position air handler is well-suited for supplemental or replacement applications. This product provides
the powerful, quiet, and efficient cooling and heating solution your home or business deserves.
or
Multi-position
Air Handler Wall-mounted
Attic
MX
Small Footprint
This air handler’s compact design makes it possible to replace existing furnaces or air handlers. Choose either a
single-zone or multi-zone system. Hybrid multi-zone applications provide a unique approach to solving zoning
problems by mixing ducted and ductless indoor units.
Flexibility Quiet
The AMT air handler is truly Multi-positional unit The DC motor ensures quiet and efficient operation
offering up, down*, left or right airflow, making it year round.
ideal for tight and unique spaces.
*Down flow kit required for down flow installations
Nv-Series 59
AMT Model
Indoor Unit Outdoor Unit
NTXAMT(12/18/24/30/36)A112A*
NTXSKS12A112A* NTXSKS(18/24/30/36)A112A*
60 Nv-Series
AMT Model
Indoor Unit Outdoor Unit
NTXAMT12/18/24/30/36A112A*
Nv-Series 61
CKS Model
Four-way Ceiling Cassette
Flexibility
The attractive CKS Model ceiling cassette units offer a slim width and a four-way air outlet. The size and shape
are a perfect match for ceilings made using 2’×2’ construction and its light weight package makes
installation easy.
The compact body matches 2’×2’ ceiling construction specifications. NTXCKS12A112A*
16-17/32
22-7/16
22-7/16 ” 22-7/16 ”
Suspension LEG Bolt to bolt
20-7/8
Suspension bolt
8-3/16
T-bar
9-21/32
Unit
Ceiling panel
22-7/16
22-11/16
23-5/8 (unit: in.)
-80
120
0°
12
°
62 Nv-Series
CKS Model Remote
Controller
Indoor Unit Outdoor Unit
*Optional
TAR-40MAAU
*Optional
TAR-CT01MAU-SB
NTXSKS(09/12/15)A112A* NTXSKS18A112A*
NTXCKS(09/12/15/18 A112A*
USNAP T-STAT
Optional Optional Optional Optional Optional Optional
*Optional
Optional
*Optional
PAR-SL100A-E TAC YT53CRAU-J
Heat Caulking
USNAP Fixing Method T-STAT
Optional Optional Optional Optional Optional Optional Optional
*Optional
TAR-40MAAU
*Optional
TAR-CT01MAU-SB
USNAP T-STAT
Optional Optional Optional Optional Optional Optional Optional
*Optional *Optional
Heat Caulking
USNAP Fixing Method T-STAT PAR-SL100A-E TAC YT53CRAU-J
Optional Optional Optional Optional Optional Optional Optional
64 Nv-Series
DKS Model
Low Static Horizontal-ducted
F A Air inlet
B Air outlet
E C Access door
D Ceiling surface
E Canvas duct
F Air filter
G Inlet grille
B D C G A
Nv-Series 65
DKS Model Remote
Controller
Indoor Unit Outdoor Unit
*Optional
TAR-40MAAU
*Optional
TAR-CT01MAU-SB
NTXDKS(09/12/15/18)A112A*
NTXSKS(09/12/15)A112A* NTXSKS18A112A*
VAQ
USNAP T-STAT
Optional Optional Optional Optional Optional Optional Optional Optional
*Optional *Optional
Heat Caulking TAC YT53CRAU-J
AT Fixing Method
l Optional
66 Nv-Series
DKS Model Remote
Controller
Indoor Unit Outdoor Unit
*Optional
TAR-40MAAU *Optional
TAR-CT01MAU-SB
NTXDKS(09/12/15/18)A112A*
NTXSKH(09/12/15/18)A112A*
VAQ
USNAP T-STAT
Optional Optional Optional Optional Optional Optional Optional Optional *Optional
Heat Caulking *Optional TAC YT53CRAU-J
-STAT Fixing Method
Optional Optional
Nv-Series 67
TPEAD Model
Mid Static Horizontal-ducted
The thin, ceiling-concealed indoor units of this model are the perfect answer for the air conditioning needs
of buildings with minimum ceiling installation space and wide-ranging external static pressure. Energy-saving
efficiency has been improved, reducing electricity consumption and contributing to a further reduction in
operating cost.
Model 12 18 24 30 36 42
12 18 24 30 36 42 12 18 24 30 36 42
68 Nv-Series
TPEAD Model Remote
Controller
Indoor Unit Outdoor Unit
*Optional
TAR-40MAAU
*Optional
TAR-CT01MAU-SB
TPEADA0(09/12/15/18/24/30/36)1AA70A
NTXSKS(09/12/15)A112A* NTXSKS(18/24/30/36)A112A*
VAQ
USNAP T-STAT
Optional Optional Optional Optional Optional Optional Optional Optional *Optional
*Optional TAC YT53CRAU-J
Heat Caulking
-STAT Fixing Method
Optional Optional
Capacity Rated 1 BTU/H 9,000 12,000 15,000 18,000 24,000 27,000 33,000
Capacity Range Min-Max BTU/H 4,300–9,000 4,400–12,000 5,500–15,000 6,200–18,000 12,000–24,000 13,200–27,000 14,000–33,000
Cooling Power Input Rated 1 W 720 930 1,150 1,270 1,920 2,160 3,510
Moisture Removal Pints/h 0.8 1.1 1.3 3.2 4.9 3.9 4.8
Sensible Heat Factor 0.900 0.900 0.900 0.800 0.770 0.840 0.840
Capacity at 47ºF Rated 2 BTU/H 12,000 15,000 18,000 21,600 25,000 30,000 33,400
Capacity Range Min-Max BTU/H 3,960–13,000 4,800–17,000 4,900–21,500 8,120–25,600 14,400–28,000 15,860–33,000 14,750–36,000
Power Input at 47ºF Rated 2 W 900 1,160 1,350 1,600 1,990 2,410 3,170
Heating Rated 3 BTU/H 7,600 9,900 11,300 14,000 15,000 22,400 23,000
Capacity at 17ºF
Max BTU/H 7,600 9,900 11,300 14,000 15,000 22,400 23,100
Capacity at 5ºF Max 4 BTU/H 6,100 7,900 10,100 12,000 — — —
Capacity at -5ºF Max 5 BTU/H — — — — — — —
SEER 19.7 20.5 19.2 19.8 18.0 18.0 16.0
EER 12.5 12.9 13.0 14.1 12.5 12.5 9.4
Efficiency HSPF 12.6 13.0 11.6 12.9 11.2 12.6 11.6
COP 3.9 3.7 3.9 3.9 3.6 3.6 3.0
ENERGY STAR® Certified Yes Yes Yes Yes Yes Yes No
Air Flow Rate - Cooling
Dry CFM 282–318–353 353–424–494 424–512–600 424–512–600 512–635–741 618–742–883 847–1024–1201
(Quiet-Lo-Med-Hi-SHi)
Air Flow Rate - Cooling
Wet CFM 254–286–318 318–382–445 382–461–540 382–461–540 461–572–667 556–668–795 762–922–1081
(Quiet-Lo-Med-Hi-SHi)
Air Flow Rate - Heating
Dry CFM 282–318–353 353–424–494 424–512–600 424–512–600 512–635–741 618–742–883 847–1024–1201
(Quiet-Lo-Med-Hi-SHi)
Sound Pressure Level
Cooling dB(A) 24–26–28 28–30–34 30–33–37 30–33–37 30–33–37 30–34–39 33–38–42
(Quiet-Lo-Med-Hi-SHi)
Sound Pressure Level (Quiet-
Indoor Unit Heating dB(A) 24–26–28 28–30–34 30–33–37 30–33–37 30–33–37 30–34–39 33–38–42
Lo-Med-Hi-SHi)
0.14–0.2–0.28– 0.14–0.2–0.28– 0.14–0.2–0.28– 0.14–0.2–0.28– 0.14–0.2–0.28– 0.14–0.2–0.28– 0.14–0.2–0.28–
External Static Pressure In. W.G.
0.4–0.6 0.4–0.6 0.4–0.6 0.4–0.6 0.4–0.6 0.4–0.6 0.4–0.6
Condensate Lift Mechanism Max Distance In. [mm] 279/16 [700] 27-9/16 [700] 279/16 [700] 27-9/16 [700] 27-9/16 [700] 27-9/16 [700] 27-9/16 [700]
H In. [mm] 9-7/8 [250] 9-7/8 [250] 9-7/8 [250] 9-7/8 [250] 9-7/8 [250] 9-7/8 [250] 9-7/8 [250]
Dimensions W In. [mm] 35-7/16 [900] 35-7/16 [900] 35-7/16 [900] 35-7/16 [900] 43-5/16 [1100] 43-5/16 [1100] 55-1/8 [1400]
D In. [mm] 28-7/8 [732] 28-7/8 [732] 28-7/8 [732] 28-7/8 [732] 28-7/8 [732] 28-7/8 [732] 28-7/8 [732]
Weight lbs [kg] 58 [26] 58 [26] 62 [28] 62 [28] 69 [31] 69 [31] 86 [39]
MCA A 9.0 9.0 10.0 14.0 17.0 17.0 17.0
MOCP A 15 16 18 24 31 31 31
H In. [mm] 21-5/8 [550] 21-5/8 [550] 21-5/8 [550] 34-5/8 [880] 34-5/8 [880] 34-5/8 [880] 34-5/8 [880]
Dimensions W In. [mm] 31-1/2 [800] 31-1/2 [800] 31-1/2 [800] 33-1/16 [840] 33-1/16 [840] 33-1/16 [840] 33-1/16 [840]
Outdoor Unit D In. [mm] 11-1/4 [285] 11-1/4 [285] 11-1/4 [285] 13 [330] 13 [330] 13 [330] 13 [330]
Weight lbs [kg] 81 [37] 81 [37] 81 [37] 127 [58] 129 [59] 129 [59] 129 [59]
Air Flow Rate (Cooling/
CFM 1228/1172 1228/1172 1243/1229 1691/1691 2020/1930 2020/1930 2020/1930
Heating)
Cooling dB(A) 48 49 49 54 55 55 55
Sound Pressure Level
Heating dB(A) 50 51 51 55 55 55 55
Gas (O.D.) In. [mm] 3/8 [9.52] 3/8 [9.52] 1/2 [12.7] 1/2 [12.7] 5/8 [15.88] 5/8 [15.88] 5/8 [15.88]
Diameter Liquid (O.D) In. [mm] 1/4 [6.35] 1/4 [6.35] 1/4 [6.35] 1/4 [6.35] 3/8 [9.52] 3/8 [9.52] 3/8 [9.52]
Piping Indoor Drain In. [mm] 1-1/4 [32] 1-1/4 [32] 1-1/4 [32] 1-1/4 [32] 1-1/4 [32] 1-1/4 [32] 1-1/4 [32]
Max. Length ft [m] 65 [20] 65 [20] 65 [20] 100 [30] 100 [30] 100 [30] 100 [30]
Max. Height ft [m] 40 [12] 40 [12] 40 [12] 50 [15] 100 [30] 100 [30] 100 [30]
Outdoor-Indoor 6 V, ph, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Electrical
Recommended Breaker Size A 15 15 15 15 20 20 20
Refrigerant Type R410A R410A R410A R410A R410A R410A R410A
14 to 115 14 to 115 14 to 115 14 to 115 14 to 115 14 to 115 14 to 115
Guaranteed Cooling 7 ºF DB [ºC DB]
[-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0]
Temperature
-4 to -75 -4 to -75 -4 to -75 -4 to -75 14 to -75 14 to -75 14 to -75
Operation Range Heating ºF DB [ºC DB]
[-20.0 to 24.0] [-20.0 to 24.0] [-20.0 to 24.0] [-20.0 to 24.0] [-10.0 to 24.0] [-10.0 to 24.0] [-10.0 to 24.0]
Notes:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed) 3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
4
Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
Conditions 5
Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB
6
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7
Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
Nv-Series 69
TPEAD Model Indoor Unit Outdoor Unit
Remote
Controller
*Optional
TAR-40MAAU
*Optional
TAR-CT01MAU-SB
TPEADA0(09/12/15/18/24/30/36)1AA70A
NTXSKH(09/12/15/18)A112A* NTXSKH24A112A* NTXSKH(30/36)A112A*
VAQ
USNAP T-STAT
Optional Optional Optional Optional Optional Optional Optional Optional
*Optional
Heat Caulking *Optional
AT Fixing Method
TAC YT53CRAU-J
al Optional
Capacity Rated 1 BTU/H 9,000 12,000 15,000 18,000 24,000 30,000 33,000
Capacity Range Min-Max BTU/H 5,000–9,000 5,770–12,000 9,600–15,000 9,320–18,000 10,000–24,000 14,600–30,000 15,600–33,000
Cooling Power Input Rated 1 W 650 850 1,190 1,400 2,080 2,350 2,490
Moisture Removal Pints/h 1.4 1.9 2.4 3.6 6.9 6.5 3.6
Sensible Heat Factor 0.820 0.820 0.820 0.780 0.680 0.760 0.880
Capacity at 47ºF Rated 2 BTU/H 12,000 15,000 18,000 21,600 25,000 32,000 37,000
Capacity Range Min-Max BTU/H 8,200–14,000 7,900–18,000 8,800–23,000 8,800–28,000 10,000–28,000 14,700–34,000 17,400–40,000
Power Input at 47ºF Rated 2 W 910 1,100 1,710 1,890 1,920 2,740 2,940
Heating Rated 3 BTU/H 6,800 9,000 11,700 14,200 18,000 21,000 25,400
Capacity at 17ºF
Max BTU/H 12,000 15,000 18,000 21,600 25,000 32,000 37,000
Capacity at 5ºF Max 4 BTU/H 12,000 15,000 18,000 21,600 25,000 32,000 37,000
Capacity at -5ºF Max 5 BTU/H — — — — — — —
SEER 17.8 19.3 18.3 18.9 15.0 15.0 15.0
EER 13.8 14.1 12.6 12.8 10.3 12.5 12.5
Efficiency HSPF 10.8 11.0 9.9 10.8 9.0 9.0 9.0
COP 3.8 3.9 3.0 3.3 3.8 3.4 3.7
ENERGY STAR® Certified Yes Yes Yes Yes No Yes Yes
Air Flow Rate - Cooling
Dry CFM 282–318–353 353–424–494 424–512–600 424–512–600 512–635–741 618–742–883 847–1024–1201
(Quiet-Lo-Med-Hi-SHi)
Air Flow Rate - Cooling
Wet CFM 254–286–318 318–382–445 382–461–540 382–461–540 461–572–667 556–668–795 762–922–1081
(Quiet-Lo-Med-Hi-SHi)
Air Flow Rate - Heating
Dry CFM 282–318–353 353–424–494 424–512–600 424–512–600 512–635–741 618–742–883 847–1024–1201
(Quiet-Lo-Med-Hi-SHi)
Sound Pressure Level
Cooling dB(A) 24–26–28 28–30–34 30–33–37 30–33–37 30–33–37 30–34–39 33–38–42
(Quiet-Lo-Med-Hi-SHi)
Sound Pressure Level (Quiet-
Indoor Unit Heating dB(A) 24–26–28 28–30–34 30–33–37 30–33–37 30–33–37 30–34–39 33–38–42
Lo-Med-Hi-SHi)
0.14–0.2–0.28– 0.14–0.2–0.28– 0.14–0.2–0.28– 0.14–0.2–0.28– 0.14–0.2–0.28– 0.14–0.2–0.28– 0.14–0.2–0.28–
External Static Pressure In. W.G.
0.4–0.6 0.4–0.6 0.4–0.6 0.4–0.6 0.4–0.6 0.4–0.6 0.4–0.6
Condensate Lift Mechanism Max Distance In. [mm] 279/16 [700] 27-9/16 [700] 279/16 [700] 27-9/16 [700] 27-9/16 [700] 27-9/16 [700] 27-9/16 [700]
H In. [mm] 9-7/8 [250] 9-7/8 [250] 9-7/8 [250] 9-7/8 [250] 9-7/8 [250] 9-7/8 [250] 9-7/8 [250]
Dimensions W In. [mm] 35-7/16 [900] 35-7/16 [900] 35-7/16 [900] 35-7/16 [900] 43-5/16 [1100] 43-5/16 [1100] 55-1/8 [1400]
D In. [mm] 28-7/8 [732] 28-7/8 [732] 28-7/8 [732] 28-7/8 [732] 28-7/8 [732] 28-7/8 [732] 28-7/8 [732]
Weight lbs [kg] 58 [26] 58 [26] 62 [28] 62 [28] 69 [31] 69 [31] 86 [39]
MCA A 14.0 14.0 17.0 17.0 17.0 24.0 26.0
MOCP A 24 24 31 31 27 40 42
H In. [mm] 34-5/8 [880] 34-5/8 [880] 34-5/8 [880] 34-5/8 [880] 37-1/8 [943] 52-11/16 [1338] 52-11/16 [1338]
Dimensions W In. [mm] 38-1/16 [840] 33-1/16 [840] 33-1/16 [840] 33-1/16 [840] 37-13/32 [950] 41-5/16 [1050] 41-5/16 [1050]
Outdoor Unit D In. [mm] 13 [330] 13 [330] 13 [330] 13 [330] 14-3/16 [360] 14-3/16 [360] 14-3/16 [360]
Weight lbs [kg] 129 [58.5] 129 [58.5] 131 [59.5] 131 [59.5] 190 [86] 261 [118] 261 [118]
Air Flow Rate (Cooling/
CFM 1,691/1,691 1,691/1,691 2,020/1,930 2,020/1,930 800/800 590/680 590/680
Heating)
Cooling dB(A) 54 54 55 55 52 52 52
Sound Pressure Level
Heating dB(A) 55 55 55 55 53 53 53
Gas (O.D.) In. [mm] 3/8 [9.52] 3/8 [9.52] 1/2 [12.7] 1/2 [12.7] 5/8 [15.88] 5/8 [15.88] 5/8 [15.88]
Diameter Liquid (O.D) In. [mm] 1/4 [6.35] 1/4 [6.35] 1/4 [6.35] 1/4 [6.35] 3/8 [9.52] 3/8 [9.52] 3/8 [9.52]
Piping Indoor Drain In. [mm] 1-1/4 [32] 1-1/4 [32] 1-1/4 [32] 1-1/4 [32] 1-1/4 [32] 1-1/4 [32] 1-1/4 [32]
Max. Length ft [m] 65 [20] 65 [20] 65 [20] 100 [30] 165 [50] 245 [75] 245 [75]
Max. Height ft [m] 40 [12] 40 [12] 40 [12] 50 [15] 100 [30] 100 [30] 100 [30]
Outdoor-Indoor 6 V, ph, Hz 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
Electrical
Recommended Breaker Size A 15 15 20 20 25 35 35
Refrigerant Type R410A R410A R410A R410A R410A R410A R410A
0 to 115 0 to 115 0 to 115 0 to 115 0 to 115 0 to 115 0 to 115
Guaranteed Cooling 7 ºF DB [ºC DB]
[-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0] [-10.0 to 46.0]
Temperature
-13 to 75 -13 to 75 -13 to 75 -13 to 75 -13 to 75 -13 to 75 -13 to 75
Operation Range Heating ºF DB [ºC DB]
[-25.0 to 24.0] [-25.0 to 24.0] [-25.0 to 24.0] [-25.0 to 24.0] [-25.0 to 24.0] [-25.0 to 24.0] [-25.0 to 24.0]
Notes:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
at a fixed compressor speed) 3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
4
Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
Conditions 5
Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB
6
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
7
Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
70 Nv-Series
P-Series
Our professional line of products
provide solutions for residential
and commercial single-zone
applications.
P-Series Product Lineup
The P-Series lineup includes a selection of six indoor units and three categories of outdoor units. You can easily
build a system that best matches the application’s heating and cooling needs.
Wall-mounted
Ceiling-concealed Ceiling-suspended
TPKA
Four-way Ceiling TPEAD TPCA
Cassette TPLA
Multi-position
Air Handler TPVA
Cooling Only
Heat Pump
P-Series 73
P-Series
Industry-leading energy efficiency has been achieved by optimizing a newly designed compressor and using
the latest energy-saving technologies. All compressors offer high performance due to advanced variable-speed
INVERTER-drive technology, which varies the compressor speed dynamically to adapt to the room’s conditioning
requirements.
SEER 14 HSPF
28 27.0
12.8
26 13
24.6 24.2
24 22.8 12 11.6
21.8 11.2
22 21.0 11.0
11
20 10.4
18 10
9.3
16
9
14
8
12
10 7
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
0A
0A
0A
0A
0A
0A
0A
0A
0A
0A
0A
0A
01
01
02
03
03
04
01
01
02
03
03
04
21
81
41
01
61
21
21
81
41
01
61
21
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
70
70
70
70
70
70
70
70
70
70
70
70
A
A
Advanced Energy-Saving Technology
Highly efficient fan for outdoor unit Improved fan (A36-42)
Fan opening of 21-3/4” (A36-42) A newly designed fan increases airflow capacity and
reduces operation noise.
The opening for the fan in the outdoor unit is
The
21-3/4” in diameter. opening for
Exchanging heatthe fan efficiently
more
in the energy-savings
contributes to increased outdoor unit isand lower
noise levels. 21-3/4" in diameter.
The opening for the fan Fan rear edge
in the outdoor unit is
21-3/4" in diameter. The opening for the fan
in the outdoor unit is
21-3/4" in diameter.
Fan rear edge
Fan rear edge
2 lines, 64 columns
74 P-Series (A36-42)
Cooling Only
TRUY Model
High Reliability and Performance in Low Ambient Conditions
The TRUY Model cooling only unit provides cooling all year round, even in cold climate low ambient conditions.
Previous
By model
controlling (PUY-A**NKA/NHA6)
the fan speed, the TRUY can offer stable cooling operation down to -40° F.
*Optional Air Protection Guide/Wind Baffle is needed when ambient temperature is under 23° F.
Previous
115° F tomodel
14° F(PUY-A**NKA/NHA6)
(46° C to –10° C)
Low Ambient Cooling Operation Range Piping Length
115° F to 14° F (46° C to –10° C)
Piping
Previous model (PUY-A**NKA/NHA6)
New model (TRUYA0**1*A70NA) Length (ft) Height (ft)
115° F to 14° F (46° C to –10° C)
New
115°model (TRUYA0**1*A70NA)
F to –40° F (46° C to –40° C)
TRUZA0121KA70NA 100 100
115° F
115° F to –40° F (46° C to –40° C)
14° F –40° F TRUZA0301KA70NA 165 100
New60
UNIT 2
seconds
model
OFF OFF
(TRUYA0**1*A70NA) ON ON
60 seconds
UNIT 2
OFF OFF
Continuous Operation
A control algorithm allows for stable continuous operation to meet cooling requirements all year round. The unit will quickly restart with the
same operation mode as before the power failure.
P-Series 75
Heat Pump
TRUZ Model - Quiet Operation
Sound Level
TRUZ Series
outdoor unit*
44 dB(A)
30 dB(A) 40 dB(A) 50 dB(A) 60 dB(A) 70 dB(A) 80 dB(A) 90 dB(A)
TRUZ Series
outdoor unit*
HSPF SEER
Wide Operation Range *TRUZ 12/18 cooling mode Cooling 0° F*1 to 115° F (46° C to –18.8° C)
27.0
25 24.6 15
P-Series heat pumps offer a wide temperature Heating
60 dB(A) 24.2 dB(A)
65-75 -4° F to
22.870° F (-20° C to 19° C)*2
40 dB(A) Quiet passenger Traditional heat-pump 80 dB(A)
21.8
operation range, easily fitting many climate design
Library interior car interior (40km/h) outdoor unit
21.0
Subway car interior
20 12.8 13
conditions. *1 In case that the air protection guide wind baffle is installed. (In case the wind
44 dB(A) baffle is not installed, the minimum
11.6
temperature will be 23° F (–5° C) DB)
*2 A24/30/36/42
11.0 11.2
30 dB(A) 40 dB(A) 50 dB(A) 15 60 dB(A) 70 dB(A) 80 dB(A) 11 90 dB(A)
Flexible Installation 10.4
9.3
Long Piping Length 10 Energy Efficiency HSPF9 SEER
TP
TP
TP
TP
TP
LA
LA
LA
LA
LA
LA
21.8
or strip malls.
0A
0A
0A
0A
0A
0A
21.0
01
01
02
03
03
04
20 12.8 13
21
81
41
01
61
21
EA
EA
EA
EA
EA
EA
70
70
70
70
70
70
Piping
A
11.6
11.0 11.2
15 11
Length (ft) Height (ft) 10.4
9.3
TRUYA0121KA70NA 100 100 10 9
TP
TP
TP
TP
TP
LA
LA
LA
LA
LA
LA
0A
0A
0A
0A
0A
0A
01
01
02
03
03
04
21
81
41
01
61
21
EA
EA
EA
EA
EA
70
70
70
70
70
70
A
76 P-Series
Hyper-heating
TRUZH Model
Improved Heating Performance
Our unique Flash Injection circuit achieves remarkably high heating performance. This technology has resulted
in excellent heating capacity ratings in outdoor temperatures as low as 5° F. The guaranteed heating operation
range of the heating mode extends to -13° F.
38,000 TRUZH036
capacity (Btu/h)
TRUZH030
Heating
22,000 TRUZA
030 -13oF TRUZH Series
-13oF - 4oF 5oF 19oF 32oF -13oF -4oF 5 oF 14oF 23oF 32oF
Outdoor-air Temperature
Enhanced Comfort
The Flash Injection circuit improves start-up and recovery from the defrosting operation. The defrost operation
control improves the required defrost frequency. These features enable the temperature to reach the set point
fast and contribute to maintaining the desired setting.
Quick Start-up
Quick Start-up
Operation at 36° F outdoor temperature Operation at -4° F outdoor temperature
Discharged air
Operation at 36° F outdoor temperature temperature reaches 122o F Operation at -4° F outdoor temperature
H2i rises quickly, Discharged air
(in stable condition) H2i rises quickly,
113°rises
F in 10min temperature reaches 122o F 113° F in quickly,
20min
H2i quickly, Stable (in stable condition) H2i rises
38,000 38,000
113° F in 10min Stable 113° F in 20min
(BTU/h)
(BTU/h)
(BTU/h)
Heating
Heating
Heating
o
113 F in INV:
19min 113o
F inINV:
30min
capacity
capacity
30,000
Normal Normal
30,000
113o F in 19min 33% faster 113o F in 30min
capacity
capacity
P-Series 77
TPLA Model
Four-way Ceiling Cassette
Four-way Cassette
TPLA
Power Inverter
27.0 12.8
12 18 24 30 36 42 12 18 24 30 36 42
78 P-Series
Horizontal Airflow
Draft Reduction Vane Setting 4-, 3-, or 2- way outlet selection*
4-, 3-, or 2- way outlet selection*
Easy Installation
Electrical Box Wiring Increased Space For Piping Work
Product design improvements to the power supply The updated product design includes reversing the
terminal position enhance connectivity and increase gas and liquid line connections to enhance piping
ease of installation. installation. Additional piping improvements include
Previous Model (BA Model) New Model (EA Model) increased space surrounding the connections,
permitting a larger wrench turning radius.
50°
70°
P-Series 79
for P-Series
Detects Number Of People
Detects number
The 3D i-see Sensor® detects the number of people of people
in the room and adjusts the power accordingly.
This makes automatic power-saving operation
Detects people’s
possible in places where the number of people position
changes frequently. Additionally, when the area is
continuously unoccupied, the system switches to a
more enhanced power-saving mode. Depending on Detects position
360°
the setting, it can also stop the operation. and number of people
Detection
Detects floor
temperature 8 ft.
Detects People’s Position 23 ft.
8 sensors
Once a person is detected, the angle of the vane 3 ft.
80 P-Series
TPLA Model
35-71 100-250 35-140 35-71
Heat Caulking
Fixing Method
JointL ap Vector Sine Wave DC Scroll DC FanM otor Vector-Wave Grooved Piping
Model Selection
Indoor Unit Outdoor Unit
Cooling Only
TPLA0A0(12/18/24/30/36/42)1EA70A
Heat Pump
Hyper-heating
TRUZH0241HA10NA TRUZH0(30/36/42)1KA00NA
Remote Controller
P-Series 81
TPLA Model Optional Optional
60-140V/200/250
Optional
Wi-Fi
Interface
Cooling Only
Optional Optional Optional Optional Optional
Notes:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
at a fixed compressor speed)
5
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6
Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating
• Fan Motor Support: Epoxy resin coating (at edge face)
• Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
• “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
82 P-Series
TPLA Model
PUHZ
Wi-Fi
Interface
Heat Pump
Optional Optional Optional Optional Optional Optional
P-Series 83
TPLA Model Optional Optional
60-140V/200/250
Optional
Wi-Fi
Interface
Hyper-heating
Optional Optional Optional Optional Optional
84 P-Series
TPKA Model
Wall-mount
SEER HA6/KA6 Series HA7/KA7 Series HSPF HA6/KA6 Series HA7/KA7 Series
21.4
20.8
19.8 11.0
10.8
18.5 18.8
17.0 10.2 10.2
9.9
15.3 15.5 9.5
14.0 9.3 9.2
8.9
12 18 24 30 36 12 18 24 30 36
86 P-Series
TPKA Model
35-71 100-250 35-140 35-71
Heat Caulking
Fixing Method
JointL ap Vector Sine Wave DC Scroll DC FanM otor Vector-Wave Grooved Piping
Model Selection
Indoor Unit Outdoor Unit
Cooling Only
TPKA0A0(12/18)1HA70A
Heat Pump
Hyper-heating
TRUZH0241HA10NA TRUZH0(30/36)1KA00NA
Remote Controller
P-Series 87
TPKA Model
60-140V/200/250
Wi-Fi
Interface
Notes:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
at a fixed compressor speed)
5
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6
Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating
• Fan Motor Support: Epoxy resin coating (at edge face)
• Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
• “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
88 P-Series
TPKA Model Optional Optional Optional Optional Optional Optional
Wi-Fi
Interface
Optional
Heat Pump
Optional Optional
P-Series 89
TPKA Model
60-140V/200/250
Wi-Fi
Hyper-heating
Interface
Optional Optional Optional
90 P-Series
TPVA Model
Multi-position Air Handler
21.4 SEER
20.5
20.2
19.3
19.0
18.0
Interlocking Function
The TPVA Model has an output terminal which allows it to interlock with other appliances such as humidifiers
and dehumidifiers.
Thermostat Control
Using the Thermostat Interface (PAC-US444CN-1), the user can replace
their unitary air conditioner without changing the thermostat.
92 P-Series
TPVA Model
35-71 100-250 35-140 35-71
Heat Caulking
Fixing Method
JointL ap Vector Sine Wave DC Scroll DC FanM otor Vector-Wave Grooved Piping
Model Selection
Indoor Unit Outdoor Unit
Cooling Only
Heat Pump
TPVA0A0(12/18/24/30/36/42)1AA70A
Hyper-heating
TRUZH0241HA10NA TRUZH0(30/36/42)1KA00NA
Remote Controller
P-Series 93
TPVA Model
60-140V/200/250
Wi-Fi
Interface
Cooling Only
Optional Optional Optional
Notes:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
at a fixed compressor speed)
5
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6
Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating
• Fan Motor Support: Epoxy resin coating (at edge face)
• Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
• “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
94 P-Series
TPVA Model Optional Optional Optional Optional Optional Optional
Wi-Fi
Interface
Optional
Heat Pump
Optional Optional
P-Series 95
TPVA Model
60-140V/200/250
Wi-Fi
Interface
96 P-Series
TPEAD Model
Mid Static Horizontal-ducted
The thin, ceiling-concealed indoor units of this model are the perfect answer for the air conditioning needs
of buildings with minimum ceiling installation space and wide-ranging external static pressure. Energy-saving
efficiency has been improved, reducing electricity consumption and contributing to a further reduction in
operating cost.
Model 12 18 24 30 36 42
12 18 24 30 36 42 12 18 24 30 36 42
98 P-Series
TPEAD Model
35-71 100-250 35-140 35-71
Heat Caulking
Fixing Method
JointL ap Vector Sine Wave DC Scroll DC FanM otor Vector-Wave Grooved Piping
Model Selection
Indoor Unit Outdoor Unit
Cooling Only
Heat Pump
TPEADA0(12/18/24/30/36/42)1AA70A
Hyper-heating
TRUZH0241HA10NA TRUZH0(30/36/42)1KA00NA
Remote Controller
P-Series 99
TPEAD Model
60-140V/200/250
Wi-Fi
Interface
Notes:
AHRI Rated Conditions 1
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
at a fixed compressor speed)
5
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6
Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating
• Fan Motor Support: Epoxy resin coating (at edge face)
• Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
• “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
100 P-Series
TPEAD Model Optional Optional Optional Optional Optional Optional
Wi-Fi
Interface
Optional
Heat Pump
Optional Optional
P-Series 101
TPEAD Model
60-140V/200/250
Wi-Fi
Hyper-heating
Interface
Optional Optional Optional
102 P-Series
TPCA Model
Ceiling Suspended
21.2
19.6 10.9 10.8
19.1
17.6 10.2 10.2 10.2 10.2
16.8 10.0
15.8
14.5 14.4 9.2
24 30 36 42 24 30 36 42
unit location.
The Automatic Air-speed Adjustment setting changes the speed to match the
room environment conditions. The airflow is set to high at the start of the Start of cooling/heating After room temperature is stabilized
heating or cooling operation, quickly conditioning the space. When the room
temperature reaches the set point, the airflow decreases automatically for Strong Gentle
104 P-Series
TPCA Model
35-71 100-250 35-140 35-71
Heat Caulking
Fixing Method
JointL ap Vector Sine Wave DC Scroll DC FanM otor Vector-Wave Grooved Piping
Model Selection
Indoor Unit Outdoor Unit
Cooling Only
TRUYA0(24/30)1HA70NA TRUYA0(36/42)1KA70NA
Heat Pump
TPCA0A0(24/30/36/42)1KA70A
TRUZA0(24/30)1HA70NA TRUZA0(36/42)1KA70NA
Hyper-heating
TRUZH0241HA10NA TRUZH0(30/36/42)1KA00NA
Remote Controller
P-Series 105
TPCA Model
60-140V/200/250
Wi-Fi
Interface
Notes:
AHRI Rated Conditions Cooling (Indoor // Outdoor)
1
°F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined
at a fixed compressor speed)
5
Indoor units receive power from outdoor units through field-supplied interconnected wiring.
6
Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -40°F - 115°F. Refer to wind baffle documentation for further information.
SEACOAST PROTECTION
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating
• Fan Motor Support: Epoxy resin coating (at edge face)
• Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
• “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
106 P-Series
TPCA Model Optional Optional Optional Optional Optional Optional
Wi-Fi
Interface
Optional
Heat Pump
Optional Optional
P-Series 107
TPCA Model
60-140V/200/250
Wi-Fi
Hyper-heating
Interface
Optional Optional Optional
108 P-Series
Multi-Zone
Models
Nv-Series multi-zone outdoor units
operate 2 to 8 indoor units on the
same system.
Multi-Zone Nv-Model Lineup
Choose from six types of indoor units and thirteen outdoor units that can run up to eight indoor units each.
CKS Model
WPH
Check Branch Box Refer to the Indoor Unit Compatibility Table for units that require a Branch Box.
If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.
MSZ-EF
WST WST
TAC-MKA32BC
WPH UKS TAC-MKA52BC
FKS
FKS CKS
MSDD-50AR-E
or
MSDD-50BR-E
Heat Caulking
Fixing Method
JointL ap Vector Sine Wave DC Scroll DC FanM otor Vector-Wave Grooved Piping
Branch Box
Type Branch Box
Model Name TAC-MKA32BC TAC-MKA52BC
Connectible Number of Indoor Units Maximum 3 Maximum 5
1-phase, 60Hz, 1-phase, 60Hz,
Power Supply
208/230V 208/230V
Input kW 0.003 0.003
Running Current A 0.05 0.05
W In. [mm] 17-23/32 [450] 17-23/32 [450]
Dimensions D In. [mm] 11-1/32 [280] 11-1/32 [280]
H In. [mm] 6-11/16 [170] 6-11/16 [170]
Weight lbs [kg] 15 [6.7] 16 [7.4]
3/8 [9.52] × 4
Branch Gas In. [mm] 3/8 [9.52] × 3
Piping 1/2 [12.7] × 1
(indoor side)*
Connection Liquid In. [mm] 1/4 [6.35] × 3 1/4 [6.35] × 5
(Flare) Main Gas In. [mm] 5/8 [15.88] 5/8 [15.88]
(outdoor side)* Liquid In. [mm] 3/8 [9.52] 3/8 [9.52]
*The piping connection size differs according to the type and capacity of indoor units.
Match the piping connection size for indoor and branch box. If the piping connection
size of branch box does not match the piping connection size of indoor units, use
optional different-diameter (deformed) joints to the branch box side. (Connect deformed
joint directly to the branch box side.)
Indoor Unit
NTXWPH06A112A* • • • • • • •
NTXWPH09A112A* • • • • • • •
NTXWPH12A112A* • • • • • • •
NTXWPH15A112A* • • • • • • •
NTXWPH18A112A* • • • • • •
NTXWST06A112A* • • • • • • •
Wall NTXWST09A112A* • • • • • • •
Mounted NTXWST12A112A* • • • • • • •
NTXWST15A112A* • • • • • • •
NTXWST18A112A* • • • • • •
NTXWST24A112A* • • • • •
MSZ-EF09NAW(S)(B) • • • • • • •
MSZ-EF12NAW(S)(B) • • • • • • •
MSZ-EF15NAW(S)(B) • • • • • • •
MSZ-EF18NAW(S)(B) • • • • • •
NTXFKS09A112A* • • • • • • •
Nv-Series Floor NTXFKS12A112A* • • • • • • •
Standing NTXFKS15A112A* • • • • • • •
NTXFKS18A112A* • • • • • •
EZ FIT™ NTXUKS09A112A* • • • • • • •
Recessed
Ceiling
NTXUKS12A112A* • • • • • • •
Cassette NTXUKS18A112A* • • • • • • •
NTXAMT12A112A* •*2 •*2 •*2 •*2 •*2 •*3, 4 •*3, 4
NTXAMT18A112A* •*2 •*2 •*2 •*2 •*3, 4 •*3, 4
Multi-position
Air Handler
NTXAMT24A112A* •*2 •*2 •*2 •*3, 4 •*3, 4
NTXAMT30A112A* •*3, 4 •*3, 4
NTXAMT36A112A* •*3, 4 •*3, 4
NTXCKS09A112A* • • • • • • •
Four-way
Cassette
NTXCKS12A112A* • • • • • • •
NTXCKS15A112A* • • • • • •
NTXDKS09A112A* • • • • • •*6 •*7
Horizontal-ducted
NTXDKS12A112A* • • • • • •*6 •*7
NTXDKS15A112A* • • • • • •*6 •*7
NTXDKS18A112A* • • • • •*6 •*7
TPLA0A0121EA70A •*5 •*5
TPLA0A0181EA70A • • • • •*5 •*5
Four-way TPLA0A0241EA70A •*5 •*5
Cassette TPLA0A0301EA70A •*5 •*5
TPLA0A0361EA70A •*5 •*5
TPLA0A0421EA70A
TPCA0A0241KA70A • • •
Ceiling TPCA0A0301KA70A
Suspended TPCA0A0361KA70A
P-Series
TPCA0A0421KA70A
TPEADA0361AA70A
TPEADA0421AA70A
Information is current as of this printing. Minimum installed capacity cannot be less than 12,000 BTU/H. *5 When the system includes even 1 unit of PLA-A·EA7, the number of the maximum connectible
A minimum of two indoor units must be connected to all MX outdoor units. indoor units is decreased as follows: 3 for NTXMPH36A142**, 4 for NTXMPH42A152**, and 6 for
*2 Only one AMT Model can be connected. NTXMPH48A182** and NTXMMX60A182**.
*3 Maximum of two units can be connected unless the SPTB1 is utilized to power the indoor unit. *6 Maximum of 3 Horizontal-ducted indoor units (TPEAD or DKS) can be connected.
*4 Single unit can be connected. *7 Maximum of 2 Horizontal-ducted indoor units (TPEAD or DKS) can be connected.
For more information, please refer to the service manual, application 1029 and the full compatibility
116 Multi-Zone Nv-Models chart on Trane.MyLinkDrive.com.
MPH Model *1
Possible combinations of outdoor units and indoor units are shown below.
Indoor Unit
NTXWPH06A112A* • • • • • •
NTXWPH09A112A* • • • • • •
NTXWPH12A112A* • • • • • •
NTXWPH15A112A* • • • • • •
NTXWPH18A112A* • • • • •
NTXWST06A112A* • • • • • •
Wall NTXWST09A112A* • • • • • •
Mounted
NTXWST12A112A* • • • • • •
NTXWST15A112A* • • • • • •
NTXWST18A112A* • • • • •
NTXWST24A112A* • • • •
MSZ-EF09NAW(S)(B) • • • • • •
MSZ-EF12NAW(S)(B) • • • • • •
MSZ-EF15NAW(S)(B) • • • • • •
MSZ-EF18NAW(S)(B) • • • • •
NTXFKS09A112A* • • • • • •
Nv-Series
Floor NTXFKS12A112A* • • • • • •
Standing NTXFKS15A112A* • • • • • •
NTXFKS18A112A* • • • • •
EZ FIT™ NTXUKS09A112A* • • • • • •
Recessed
Ceiling
NTXUKS12A112A* • • • • • •
Cassette NTXUKS18A112A* • • • • • •
NTXAMT12A112A* •*2 •*2 •*2 •*3, 4 •*3, 4 •*3, 4
NTXAMT18A112A* •*2 •*2 •*3, 4 •*3, 4 •*3, 4
Multi-position
Air Handler
NTXAMT24A112A* •*2 •*3, 4 •*3, 4 •*3, 4
NTXAMT30A112A* •*3, 4 •*3, 4 •*3, 4
NTXAMT36A112A* •*3, 4 •*3, 4 •*3, 4
NTXCKS09A112A* • • • • • •
Four-way
Cassette
NTXCKS12A112A* • • • • • •
NTXCKS15A112A* • • • • •
NTXDKS09A112A* • • • •*6 •*6 •*6
Horizontal-ducted
NTXDKS12A112A* • • • •*6 •*6 •*6
NTXDKS15A112A* • • • •*6 •*6 •*6
NTXDKS18A112A* • • •*6 •*6 •*6
TPLA0A0121EA70A •*5 •*5 •*5
TPLA0A0181EA70A • • •*5 •*5 •*5
Four-way TPLA0A0241EA70A •*5 •*5 •*5
Cassette TPLA0A0301EA70A •*5 •*5 •*5
TPLA0A0361EA70A •*5 •*5 •*5
TPLA0A0421EA70A
TPCA0A0241KA70A •
Ceiling TPCA0A0301KA70A
Suspended TPCA0A0361KA70A
P-Series
TPCA0A0421KA70A
TPEADA0361AA70A
TPEADA0421AA70A
Information is current as of this printing. Minimum installed capacity cannot be less than 12,000 BTU/H. *6 Maximum of 3 Horizontal-ducted indoor units (TPEAD or DKS) can be connected.
A minimum of two indoor units must be connected to all MX outdoor units. *7 Maximum of 2 Horizontal-ducted indoor units (TPEAD or DKS) can be connected.
*2 Only one AMT Model can be connected. For more information, please refer to the service manual, application 1029 and the full
*3 Maximum of two units can be connected unless the SPTB1 is utilized to power the indoor unit. compatibility chart on Trane.MyLinkDrive.com.
*4 Single unit can be connected.
*5 When the system includes even 1 unit of TLA-A·EA7, the number of the maximum connectible indoor
units is decreased as follows: 3 for NTXMPH36A142**, 4 for NTXMPH42A152**, and 6 for
NTXMPH48A182** and NTXMMX60A182**. Multi-Zone Nv-Models 117
Conditions
Conditions for Specifications
Temperature conditions are based on AHRI 210/240.
Nv-Series
P-Series - 208 / 230V • Single phase • 60Hz
MX Model
Conditions 119
Piping Installation
Nv-Series
Single type
Maximum Piping Length (ft) Maximum Height Difference (ft) Maximum Number of Bends
Series Class
< Outdoor unit >
Total length (A) Outdoor unit - Indoor unit (H) Total number
NTXSPH 06/09/12 65 40 10
15/18 100 50 10
NT(X/Y)SST 09/12/15 65 40 10
18/24 100 50 10
NTXSMT 09/12/15/18 65 40 10
24 100 50 10
NTXSPF 09/12 65 40 10
15/18 100 50 10
NTXSKS/NTXSKH 09/12/15 65 40 10
18 100 50 10
P-Series
Single type
Maximum Piping Length (ft) Maximum Height Difference (ft) Maximum Number of Bends
Series Class
< Outdoor unit >
Total length (A) Outdoor unit - Indoor unit (H) Total number
120 Conditions
MX Model
NTXMMX20A122AA
Indoor b
Maximum Piping Length units
Max. height difference
Outdoor unit - Indoor unit (a,b) 82 ft.
Total length (a+b) 164 ft.
Outdoor
unit
Maximum Number of Bends 49 ft.
33 ft.
a
NTXMPH20A122AA
Indoor b
Maximum Piping Length units
Max. height difference
Outdoor unit - Indoor unit (a,b) 82 ft.
Total length (a+b) 164 ft.
Outdoor
unit
Maximum Number of Bends 49 ft.
49 ft.
a
NTXMMX24A132AA, NTXMMX30A132AA,
Indoor c
NTXMPH24A132AA, NTXMPH30A132AA units
Max. height difference
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c) 82 ft.
Total length (a+b+c) 230 ft. Outdoor
unit
b 49 ft.
Maximum Number of Bends
Outdoor unit - Indoor unit (a,b,c) 25 49 ft.
Total number (a+b+c) 70
49 ft.
a
Conditions 121
MX Model
NTXMMX20A122AA
Indoor b
Maximum Piping Length units
Max. height difference
Outdoor unit - Indoor unit (a,b) 82 ft.
Total length (a+b) 164 ft.
Outdoor
unit
Maximum Number of Bends 49 ft.
33 ft.
a
NTXMPH20A122AA
Indoor b
Maximum Piping Length units
Max. height difference
Outdoor unit - Indoor unit (a,b) 82 ft.
Total length (a+b) 164 ft.
Outdoor
unit
Maximum Number of Bends 49 ft.
49 ft.
a
NTXMMX24A132AA, NTXMMX30A132AA,
Indoor c
NTXMPH24A132AA, NTXMPH30A132AA units
Max. height difference
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c) 82 ft.
Total length (a+b+c) 230 ft. Outdoor
unit
b 49 ft.
Maximum Number of Bends
Outdoor unit - Indoor unit (a,b,c) 25 49 ft.
Total number (a+b+c) 70
49 ft.
a
122 Conditions
NTXMMX36A142AA Indoor d
Maximum Piping Length units
Max. height difference
Outdoor unit - Indoor unit (a,b,c,d) 82 ft.
Total length (a+b+c+d) 230 ft.
c Outdoor
unit 49 ft.
Maximum Number of Bends
Outdoor unit - Indoor unit (a,b,c,d) 25 49 ft.
70 b
Total number (a+b+c+d)
49 ft.
a
NTXMMX42A152AA
Indoor e
Maximum Piping Length units
Max. height difference
Outdoor unit - Indoor unit (a,b,c,d,e) 82 ft.
Total length (a+b+c+d+e) 262 ft. d
49 ft.
Outdoor
Maximum Number of Bends unit
Outdoor unit - Indoor unit (a,b,c,d,e) 25 c
Total number (a+b+c+d+e) 80
49 ft.
b
49 ft.
a
Conditions 123
MX Model
NTXMPH36A142AA, NTXMPH42A152AA, NTXMPH48A182AA,
NTXMMX48A182AA, NTXMMX60A182AA
A Outdoor unit
B Branch box
C Indoor unit
D
L
c1
D b2
b1
B
B h2 I
H
h1 a1
a5 a6 a7 a8
a2 a3 a4
C C C C C
C
h3
C
124 Conditions
Explanation of Terminology
Maximum Piping Length
This is the maximum allowable length of the refrigerant piping. The amount of refrigerant pipe used cannot be
longer than the length specified.
• Total Length
The maximum allowable combined length of all the refrigerant piping between the outdoor unit and
indoor unit(s).
• Outdoor Unit - Indoor Unit
The maximum allowable length of the refrigerant piping between the outdoor unit and indoor units installed
when multiple units are connected to a single outdoor unit. This distance limitation refers to the maximum
length between the outdoor unit and the farthest indoor unit.
• Pipe Length Difference From Distribution Pipe
The maximum allowable difference in refrigerant piping length from the distribution pipe to the farthest
indoor unit and from the distribution pipe to the closest indoor unit when multiple indoor units are connected
to a single outdoor unit using a distribution pipe.
• Indoor Unit - Distribution Pipe
The maximum allowable length of the refrigerant piping between indoor units and the distribution pipe when
multiple indoor units are connected to a single outdoor unit.
Conditions 125
Appendix
3 Important Points to Remember
When Installing the Outdoor Unit
Wind and snow can significantly reduce capacity. Be sure
to check the information below and install the outdoor
unit correctly.
1 Installation Location
Be aware of the prevailing wind direction in winter and in-
stall the outdoor unit where it is as sheltered as possible. Units are easily affected by
wind and unit may not be
able to run at full capacity
Note
Install at a sufficient height from the ground
to prevent problems caused by frozen
drainage water.
Install in a location where frozen drainage
water will not be a hazard. Frozen drainage water
Install in an upright position to allow proper may cause a slipping
drainage from the drainage outlet. hazard.
Appendix 127
3 Measures for Snow
Use a stand to add sufficient height to protect the unit heat exchanger from snow and pre- Install snow protection hood
vent icicles forming during defrost operation. as necessary
Correct Wrong Correct
installation Air exhaust
snow hood installation installation
Minimum height (h) Air intake Unit may become Note
Air intake snow hood Without hood
should be higher snow hood (rear) covered in snow Install the snow
(side panel)
than the highest if the stand height protection hood
snowfall depth (h0) is insufficient. or other cover in
+7.8 in. h Snowfall snowy regions.
h0 height h0
Stand height h
Recommended accessories (drain socket & centralized drain pan, stand, snow protection hood, base heater)
Snowy region Cold region
Countermeasures Countermeasures Remarks
for snow for freezing
Drain socket,
Not used Not used Prevents freezing
Centralized drain pan
Clearance to prevent
1. Install so as to prevent the unit being buried snow accumulating.
in snow (at a height greater than the highest
snowfall depth). Be sure that the stand does
Stand Needed Needed
not obstruct drainage.
<Correct>
2. Install so as to prevent damage to the unit
due to frozen drainage water (icicles).
Snow Needed
protection *When the installation — 1. Prevents heat exchanger from being covered in snow.
hood position is subject to 2. Prevents snow accumulating inside the air duct.
snowfall.
Outdoor units equipped with a heater for cold regions are those with an“H”
— in the model name. For the cold-climate zone, use of a unit with a heater is
Base heater Needed
strongly recommended. Even for the moderate-climate zone use of a unit with
a heater is recommended for regions subject to high humidity in winter.
Arrangement for Separately sold parts are available for some models.
snow protection hood Please consult Mitsubishi Electric Trane HVAC US or one of its dealers/resellers at the time of purchase for details.
128 Appendix
System Control
Versatile system controls can be achieved by using optional parts, relay circuits, control panels, etc.
System Examples
Indoor Unit Nv Series Indoor Unit DKS, CKS, AMT P Series Indoor Unit
Outdoor Unit Nv Series and MX Series Outdoor SKS and MX Series Outdoor P Series Outdoor
Indoor unit
MAC-334IF-E
Indoor unit
Outdoor unit
• MAC-334IF-E (Interface)
Major Optional Parts Required • TAR-40MAAU (Wired remote controller)
• TAR-40MAAU (Wired remote controller)
Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit
MAC-334IF-E MAC-334IF-E
• One remote controller can control plural air conditioners with the same settings simultaneously.
Details • One remote controller can control up to 16 refrigerant systems. (When connected to a MX unit, MAC-334IF-E is counted as one system.)
• Up to two remote controller can be connected.
• MAC-334IF-E (Interface)
Major Optional Parts Required • TAR-40MAAU (Wired remote controller)
• TAR-40MAAU (Wired remote controller)
Outdoor Outdoor
Outdoor unit unit unit
Outdoor unit Outdoor unit
• PAC-SJ95MA-E/PAC-SJ96MA-E
• MAC-334IF-E (M-NET Interface)
(M-NET converter)
Major Optional Parts Required • MELANS System controller
• MELANS System controller
• PAC-SC51KUA (power supply unit)
• PAC-SC51KUA (power supply unit)
Appendix 129
For Nv-Series Indoor Units
System Examples Connection Details Control Details Major Optional Parts Required
Remote On/Off Connect the interface to the air On/Off operation is possible • MAC-334IF-E (Interface)
1 Operation MAC-334IF-E conditioner. Then connect the from a remote location. • Parts for circuit such as relay
locally purchased remote box, lead wire, etc. (to be
• Air conditioner can be started/ controller to the terminal in the purchased locally)
Switch
stopped remotely. Indoor unit
interface.
( 1 and 2 can be used in Remote control section
combination) Outdoor unit (to be purchased locally)
Remote Display of Connect the interface to the air The operation status • MAC-334IF-E (Interface)
2 Operation Status MAC-334IF-E
Power supply
conditioner. Then connect the (On/Off) or error signals can be • Parts for circuit to be
locally purchased remote monitored from a remote purchased locally (DC power
• The On/Off status of air controller to the terminal in the location. source needed)
Resistance LED
conditioners can be confirmed Indoor unit
interface. • External power source (12V
remotely. Remote monitor section DC) is required when using
( 1 and 2 can be used in Outdoor unit (to be purchased locally)
MAC-334IF-E.
combination)
Operation Control by Relay box (to be purchased) locally) Relay box (to be purchased locally)
• Operation other than On/Off (e.g., adjust- • Adapter for remote On/Off
B Level Signal Adapter for Adapter for ment of temperature, fan speed, and PAC-SE55RA-E
remote remote
On/Off On/Off airflow) can be performed even when • Relay box (to be purchased locally)
Air conditioner can be started/ • Remote control panel (to be
remote controller operation is prohibited.
stopped remotely. In addition, purchased locally)
• Timer control is possible with an external
On/Off operation by local remote Remote Remote
control control timer.
controller can be panel Wired remote panel PAR-FL32MA
controller
prohibited/permitted.
(Example of 1 : 1 system x 2) (Example of 1 : 1 system x 2)
Operation Control by Relay box (to be purchased) locally) Relay box (to be purchased locally)
• The pulse signal can be turned On/Off. • Connector cable for remote display
C Pulse Signal Connector Connector • Operation/emergency signal can be PAC-SA88HA-E / PAC-725AD
cable for cable for
remote remote received at a remote location. (10 pcs. x PAC-SA88HA-E)
display display • Relay box (to be purchased locally)
• Remote control panel (to be
Remote Remote
control control purchased locally)
panel Wired remote panel PAR-FL32MA
controller
(Example of 1 : 1 system x 2) (Example of 1 : 1 system x 2)
130 Appendix
Appendix 131
Other Optional Parts
Part Name Description Part Name Description
Captures the bacteria, pollen and other Wireless Interface 2 Indoor unit
allergens in the air and neutralizes them. Interface enabling users to control air
conditioners and check operating status via
devices such as personal computers, tablets
and smart phones.
Smartphone
Silver-ionized Air Purifier Filter
Oil Mist Filter Element Filter frame CN24 Relay Kit Switch
Filter element (12 pieces) that blocks the oil This product is an adaptor which inputs the
mist for ceiling-suspended models used in incoming signals from an open/close switch Indoor unit
132 Appendix
Part Name Description Part Name Description
Socket
Base
(local construction)
PAC-USSEN001-FM-1
Control/service tool
Distribution Pipe
Indoor unit
Indoor unit
Branch pipe for P Series simultaneous multi-
system use, or to connect two branch boxes
for MX.
Outdoor unit
Distribution pipe
Joint Pipe
Part for connecting refrigerant pipes of differ- Joint pipe Onsite pipe
ent diameters. Indoor unit
Outdoor unit
Insulator
Appendix 133
Optional Parts List for Indoor [Nv-Series]
Wall-mount
NTXWPH MSZ-EF
MSZ-EF09NA(B/S/W)
MSZ-EF12NA(B/S/W)
MSZ-EF15NA(B/S/W)
MSZ-EF18NA(B/S/W)
NTXWPH06B112AA
NTXWPH09B112AA
NTXWPH12B112AA
NTXWPH15B112AA
NTXWPH18B112AA
Blue Diamond (Advanced) Mini Condensate
Pump w/ Reservoir & Sensor (208/230V) [recom- X87-721 • • • • • • • • •
mended]
Blue Diamond (MicroBlue) Mini Condensate
X85-003 • • • • • • • • •
Pump (110/208/230V) up to 18,000 BTU/H
Blue Diamond Alarm Extension Cable — 6.5 Ft. C13-192 • • • • • • • • •
Condensate Blue Diamond MultiTank — collection tank for
C21-014 • • • • • • • • •
use with multiple pumps
Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 • • • • • • • • •
Drain Pan Level Sensor/Control SS610E • • • • • • • • •
Fascia Kit for MicroBlue Pump, mounts the Mi-
T18-016 • • • • •
croBlue and sensor directly beneath indoor unit
Sauermann Condensate Pump SI30-230 • • • • • • • • •
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 • • • • •
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W • • • • • • • • •
MAC-2320FT-E • • • •
Electro Static Anti-allergy Enzyme Filter
Filter MAC-2330FT-E • • • • •
Platinum Deodorizing Filter MAC-3000FT-E • • • • •
100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube
MLS141212T-100 • •
Insulation)
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube
MLS141212T-15 • • • • •
Insulation)
15’ x 1/4” x 15’ / 3/8” Lineset (Twin-Tube
MLS143812T-15 • • • •
Insulation)
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube
MLS141212T-30 • • • • •
Insulation)
30’ x 1/4” x 30’ / 3/8” Lineset (Twin-Tube
Lineset MLS143812T-30 • • • •
Insulation)
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube
MLS141212T-50 • • • • •
Insulation)
50’ x 1/4” x 50’ / 3/8” Lineset (Twin-Tube
MLS143812T-50 • • • •
Insulation)
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube
MLS141212T-65 • • • • •
Insulation)
65’ x 1/4” x 65’ / 3/8” Lineset (Twin-Tube
MLS143812T-65 • • • •
Insulation)
Soft Dry Cloth Soft Dry Cloth MAC-1001CL-E • • • •
134 Appendix
Wall-mount
NTXWST
NTXWST06A112AA
NTXWST09A112AA
NTXWST12A112AA
NTXWST15A112AA
NTXWST18A112AA
NTXWST24A112AA
NTXWST30A112AA
NTXWST36A112AA
Blue Diamond (Advanced) Mini Condensate
Pump w/ Reservoir & Sensor (208/230V) [recom- X87-721 • • • • • • • •
mended]
Blue Diamond (MegaBlue Advanced) Conden-
X87-835 • • •
sate Pump w/ Reservoir & Sensor
Blue Diamond (MicroBlue) Mini Condensate
X85-003 • • • • •
Pump (110/208/230V) up to 18,000 BTU/H
Condensate Blue Diamond Alarm Extension Cable — 6.5 Ft. C13-192 • • • • • • • •
Blue Diamond MultiTank — collection tank for
C21-014 • • • • • • • •
use with multiple pumps
Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 • • • • • • • •
Drain Pan Level Sensor/Control SS610E • • • • • • • •
Fascia Kit for MicroBlue Pump, mounts the Mi-
T18-016 • • • • • • •
croBlue and sensor directly beneath indoor unit
Sauermann Condensate Pump SI30-230 • • • • • • • •
Controller Holder Remote Controller Holder U01A01083 • • • •
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 • • • • • • •
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W • • • • • • • •
Anti-allergy Enzyme Filter MAC-408FT-E • • • • •
Filter
Electro Static Anti-allergy Enzyme Filter MAC-2310FT-E •
10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube
MPLS385812T-10 • • •
Insulation)
100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube
MLS141212T-100 • •
Insulation)
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube
MPLS385812T-100 • • •
Insulation)
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube
MLS141212T-15 • •
Insulation)
15’ x 1/4” x 15’ / 3/8” Lineset (Twin-Tube
MLS143812T-15 • • •
Insulation)
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube
MPLS385812T-15 • • •
Insulation)
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube
MLS141212T-30 • •
Insulation)
30’ x 1/4” x 30’ / 3/8” Lineset (Twin-Tube
Lineset MLS143812T-30 • • •
Insulation)
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube
MPLS385812T-30 • • •
Insulation)
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube
MLS141212T-50 • •
Insulation)
50’ x 1/4” x 50’ / 3/8” Lineset (Twin-Tube
MLS143812T-50 • • •
Insulation)
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube
MPLS385812T-50 • • •
Insulation)
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube
MLS141212T-65 • •
Insulation)
65’ x 1/4” x 65’ / 3/8” Lineset (Twin-Tube
MLS143812T-65 • • •
Insulation)
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube
MPLS385812T-65 • • •
Insulation)
Appendix 135
Optional Parts List for Indoor [Nv-Series]
Wall-mount
NTXWMT NTXWEL
NTXWMT09A112AA
NTXWMT12A112AA
NTXWMT15A112AA
NTXWMT18A112AA
NTXWMT24A112AA
NTXWMT09A111AA
NTXWMT12A111AA
NTXWEL09A112AA
NTXWEL12A112AA
NTXWEL18A112AA
NTXWEL24A112AA
Blue Diamond (Advanced) Mini Condensate
Pump w/ Reservoir & Sensor (208/230V) [recom- X87-721 • • • • • • • • • • •
mended]
Blue Diamond (MegaBlue Advanced) Conden-
X87-835 • •
sate Pump w/ Reservoir & Sensor
Blue Diamond (MicroBlue) Mini Condensate
X85-003 • • • • • • • • •
Pump (110/208/230V) up to 18,000 BTU/H
Condensate Blue Diamond Alarm Extension Cable — 6.5 Ft. C13-192 • • • • • • • • • • •
Blue Diamond MultiTank — collection tank for
C21-014 • • • • • • • • • • •
use with multiple pumps
Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 • • • • • • • • • • •
Drain Pan Level Sensor/Control SS610E • • • • • • • • • • •
Fascia Kit for MicroBlue Pump, mounts the Mi-
T18-016 • • • • • • • • • • •
croBlue and sensor directly beneath indoor unit
Sauermann Condensate Pump SI30-230 • • • • • • • • • • •
Controller Holder Remote Controller Holder U01A01083 • • • • • • • • • • •
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 • • • • • • • • • • •
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W • • • • • • • • • • •
Filter Anti-allergy Enzyme Filter MAC-408FT-E • • • • • • • • • • •
10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube
MPLS385812T-10 • •
Insulation)
100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube
MLS141212T-100 • • •
Insulation)
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube
MPLS385812T-100 • •
Insulation)
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube
MLS141212T-15 • • •
Insulation)
15’ x 1/4” x 15’ / 3/8” Lineset (Twin-Tube
MLS143812T-15 • • • • • •
Insulation)
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube
MPLS385812T-15 • •
Insulation)
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube
MLS141212T-30 • • •
Insulation)
30’ x 1/4” x 30’ / 3/8” Lineset (Twin-Tube
Lineset MLS143812T-30 • • • • • •
Insulation)
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube
MPLS385812T-30 • •
Insulation)
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube
MLS141212T-50 • • •
Insulation)
50’ x 1/4” x 50’ / 3/8” Lineset (Twin-Tube
MLS143812T-50 • • • • • •
Insulation)
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube
MPLS385812T-50 • •
Insulation)
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube
MLS141212T-65 • • •
Insulation)
65’ x 1/4” x 65’ / 3/8” Lineset (Twin-Tube
MLS143812T-65 • • • • • •
Insulation)
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube
MPLS385812T-65 • •
Insulation)
136 Appendix
Wall-mount
NTYWST
NTYWST09A112AA
NTYWST12A112AA
NTYWST15A112AA
NTYWST18A112AA
NTYWST24A112AA
NTYWST30A112AA
NTYWST36A112AA
Blue Diamond (Advanced) Mini Condensate
Pump w/ Reservoir & Sensor (208/230V) [recom- X87-721 • • • • • • •
mended]
Blue Diamond (MegaBlue Advanced) Conden-
X87-835 • • •
sate Pump w/ Reservoir & Sensor
Blue Diamond (MicroBlue) Mini Condensate
X85-003 • • • •
Pump (110/208/230V) up to 18,000 BTU/H
Condensate Blue Diamond Alarm Extension Cable — 6.5 Ft. C13-192 • • • • • • •
Blue Diamond MultiTank — collection tank for
C21-014 • • • • • • •
use with multiple pumps
Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 • • • • • • •
Drain Pan Level Sensor/Control SS610E • • • • • • •
Fascia Kit for MicroBlue Pump, mounts the Mi-
T18-016 • • • • • • •
croBlue and sensor directly beneath indoor unit
Sauermann Condensate Pump SI30-230 • • • • • • •
Controller Holder Remote Controller Holder U01A01083 • • •
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 • • • • • • •
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W • • • • • • •
Anti-allergy Enzyme Filter MAC-408FT-E • • • •
Filter
Electro Static Anti-allergy Enzyme Filter MAC-2310FT-E •
10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube
MPLS385812T-10 • • •
Insulation)
100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube
MLS141212T-100 • •
Insulation)
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube
MPLS385812T-100 • • •
Insulation)
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube
MLS141212T-15 • •
Insulation)
15’ x 1/4” x 15’ / 3/8” Lineset (Twin-Tube
MLS143812T-15 • •
Insulation)
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube
MPLS385812T-15 • • •
Insulation)
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube
MLS141212T-30 • •
Insulation)
30’ x 1/4” x 30’ / 3/8” Lineset (Twin-Tube
Lineset MLS143812T-30 • •
Insulation)
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube
MPLS385812T-30 • • •
Insulation)
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube
MLS141212T-50 • •
Insulation)
50’ x 1/4” x 50’ / 3/8” Lineset (Twin-Tube
MLS143812T-50 • •
Insulation)
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube
MPLS385812T-50 • • •
Insulation)
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube
MLS141212T-65 • •
Insulation)
65’ x 1/4” x 65’ / 3/8” Lineset (Twin-Tube
MLS143812T-65 • •
Insulation)
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube
MPLS385812T-65 • • •
Insulation)
Appendix 137
Optional Parts List for Indoor [Nv-Series]
NTXUKS09A112AA
NTXUKS12A112AA
NTXUKS18A112AA
NTXFKS09A112AA
NTXFKS12A112AA
NTXFKS15A112AA
NTXFKS18A112AA
Blue Diamond (Advanced) Mini Condensate
Pump w/ Reservoir & Sensor (208/230V) [recom- X87-721 • • • • • • •
mended]
Blue Diamond (MicroBlue) Mini Condensate
X85-003 • • • • • • •
Pump (110/208/230V) up to 18,000 BTU/H
Condensate Blue Diamond Alarm Extension Cable — 6.5 Ft. C13-192 • • • •
Blue Diamond MultiTank — collection tank for
C21-014 • • • •
use with multiple pumps
Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 • • • •
Drain Pan Level Sensor/Control SS610E • • • •
Sauermann Condensate Pump SI30-230 • • • •
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 • • • • • • •
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W • • • • • • •
Filter Anti-allergy Enzyme Filter MAC-408FT-E • • • • • • •
Floor Mount Air
Floor Mount Air Guide MAC-760FD-E • • • •
Guide
Grille Grille TLP-444W • • •
100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube
MLS141212T-100 • • •
Insulation)
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube
MLS141212T-15 • • •
Insulation)
15’ x 1/4” x 15’ / 3/8” Lineset (Twin-Tube
MLS143812T-15 • • • •
Insulation)
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube
MLS141212T-30 • • •
Insulation)
30’ x 1/4” x 30’ / 3/8” Lineset (Twin-Tube
Lineset MLS143812T-30 • • • •
Insulation)
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube
MLS141212T-50 • • •
Insulation)
50’ x 1/4” x 50’ / 3/8” Lineset (Twin-Tube
MLS143812T-50 • • • •
Insulation)
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube
MLS141212T-65 • • •
Insulation)
65’ x 1/4” x 65’ / 3/8” Lineset (Twin-Tube
MLS143812T-65 • • • •
Insulation)
138 Appendix
Residential Multi-position
Four-way Cassette Ducted
AHU
NTXCKS NTXDKS NTXAMT
NTXAMT12A112AA
NTXAMT18A112AA
NTXAMT24A112AA
NTXAMT30A112AA
NTXAMT36A112AA
NTXDKS09A112AA
NTXDKS12A112AA
NTXDKS15A112AA
NTXDKS18A112AA
NTXCKS09A112AA
NTXCKS12A112AA
NTXCKS15A112AA
NTXCKS18A112AA
BRP1 •
Converts low-profile ducted unit from rear to
Bottom Return Plate BRP2 • •
bottom
BRP3 •
Blue Diamond (Advanced) Mini Condensate
Pump w/ Reservoir & Sensor (208/230V) [recom- X87-721 • • • • • • • • • • • • •
mended]
Blue Diamond (MegaBlue Advanced) Conden-
X87-835 • • •
sate Pump w/ Reservoir & Sensor
Blue Diamond (MicroBlue) Mini Condensate
Condensate X85-003 • • • • • • • • • •
Pump (110/208/230V) up to 18,000 BTU/H
Blue Diamond Alarm Extension Cable — 6.5 Ft. C13-192 • • • • • • • •
Blue Diamond MultiTank — collection tank for
C21-014 • • • • • • • •
use with multiple pumps
Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 • • • • • • • • • • • • •
Sauermann Condensate Pump SI30-230 • • • • • • • •
20/2PR, 1PR shielded + 1PR plenum wire for
CW2042S2-100 • • • • • • • • •
Airzone, 100 ft reel
Control Wire
20/2PR, shielded + 1PR plenum wire for Airzone,
CW2042S2-500 • • • • • • • • •
500 ft reel
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 • • • • • • • • • • • • •
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W • • • • • • • • • • • • •
DFK-M • •
Down flow Kit Down flow Kit
DFK-S • • •
Electric Heat Lockout Electric Heat Lockout ETC-211000-MIT • • • • •
10kW Electric Heater EH10-SVZ-M • •
3kW Electric Heater EH03-SVZ-S • • •
EH05-SVZ-M • •
Electric Kit Heats 5kW Electric Heater
EH05-SVZ-S • • •
EH08-SVZ-M • •
8kW Electric Heater
EH08-SVZ-S • •
FBL1-1 •
Filter Box Filter Box with MERV 8 Filter FBL1-2 • •
FBL1-3 •
Grille Grille TLP-18FAU • • • •
3D i-see Sensor® Corner Panel PAC-SF1ME-E • • • •
i-see Sensor® Panel
Grille with 3D i-see Sensor® TLP-18FAEU • • • •
10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube
MPLS385812T-10 • • •
Insulation)
100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube
MLS141212T-100 • • • • •
Insulation)
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube
MPLS385812T-100 • • •
Insulation)
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube
MLS141212T-15 • • • • •
Insulation)
15’ x 1/4” x 15’ / 3/8” Lineset (Twin-Tube
MLS143812T-15 • • • • •
Insulation)
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube
MPLS385812T-15 • • •
Insulation)
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube
MLS141212T-30 • • • • •
Insulation)
30’ x 1/4” x 30’ / 3/8” Lineset (Twin-Tube
Lineset MLS143812T-30 • • • • •
Insulation)
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube
MPLS385812T-30 • • •
Insulation)
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube
MLS141212T-50 • • • • •
Insulation)
50’ x 1/4” x 50’ / 3/8” Lineset (Twin-Tube
MLS143812T-50 • • • • •
Insulation)
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube
MPLS385812T-50 • • •
Insulation)
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube
MLS141212T-65 • • • • •
Insulation)
65’ x 1/4” x 65’ / 3/8” Lineset (Twin-Tube
MLS143812T-65 • • • • •
Insulation)
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube
MPLS385812T-65 • • •
Insulation)
Terminal Block Separate Terminal Power Block SPTB1 • • • • •
Appendix 139
Optional Parts List for Indoor [P-Series]
TPKA0A0121HA70A
TPKA0A0181HA70A
TPKA0A0241KA70A
TPKA0A0301KA70A
TPKA0A0361KA70A
TPCA0A0241KA70A
TPCA0A0301KA70A
TPCA0A0361KA70A
TPCA0A0421KA70A
Blue Diamond (Advanced) Mini Condensate
Pump w/ Reservoir & Sensor (208/230V) [recom- X87-721 • • • • • • • • •
mended]
Blue Diamond (MegaBlue Advanced) Conden-
X87-835 • • • • • • •
sate Pump w/ Reservoir & Sensor
Blue Diamond (MicroBlue) Mini Condensate
Condensate X85-003 • •
Pump (110/208/230V) up to 18,000 BTU/H
Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 • • • • • • • • •
Drain Pan Level Sensor/Control SS610E • • • • •
Fascia Kit for MicroBlue Pump, mounts the Mi-
T18-016 • •
croBlue and sensor directly beneath indoor unit
Sauermann Condensate Pump SI30-230 • • • • •
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 • • • • • • • • •
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W • • • • • • • • •
Drain Pump Kit PAC-SH84DM-E • • •
Drain Pump
External Drain Pump PAC-SH94DM-E • • •
PAC-SH89KF-E •
65% Medium Efficiency Filter (MERV 8)
Filter PAC-SH90KF-E •
High Efficiency (MERV 8) Filter Element PAC-SE81KF-E • • • •
i-see Sensor® Panel i-see Sensor® PAC-SH91MK-E •
10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube
MPLS385812T-10 • • • • • • •
Insulation)
100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube
MLS141212T-100 • •
Insulation)
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube
MPLS385812T-100 • • • • • • •
Insulation)
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube
MLS141212T-15 • •
Insulation)
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube
MPLS385812T-15 • • • • • • •
Insulation)
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube
Lineset MLS141212T-30 • •
Insulation)
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube
MPLS385812T-30 • • • • • • •
Insulation)
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube
MLS141212T-50 • •
Insulation)
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube
MPLS385812T-50 • • • • • • •
Insulation)
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube
MLS141212T-65 • •
Insulation)
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube
MPLS385812T-65 • • • • • • •
Insulation)
140 Appendix
Four-way Cassette Residential Multi-position AHU
TPLA TPVA
TPVA0A0121AA70A
TPVA0A0181AA70A
TPVA0A0241AA70A
TPVA0A0301AA70A
TPVA0A0421AA70A
TPLA0A0121EA70A
TPLA0A0181EA70A
TPLA0A0241EA70A
TPLA0A0301EA70A
TPLA0A0361EA70A
TPLA0A0421EA70A
Casement Multi-function Casement PAC-SJ41TM-E • • • • • •
Blue Diamond (Advanced) Mini Condensate
Pump w/ Reservoir & Sensor (208/230V) [recom- X87-721 • • • • • •
mended]
Blue Diamond (MegaBlue Advanced) Conden-
Condensate X87-835 • • • •
sate Pump w/ Reservoir & Sensor
Blue Diamond (MicroBlue) Mini Condensate
X85-003 • •
Pump (110/208/230V) up to 18,000 BTU/H
Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 • • • • • • • • • • •
20/2PR, 1PR shielded + 1PR plenum wire for
CW2042S2-100 • • • • •
Airzone, 100 ft reel
Control Wire
20/2PR, shielded + 1PR plenum wire for Airzone,
CW2042S2-500 • • • • •
500 ft reel
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 • • • • • • • • • • •
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W • • • • • • • • • • •
Condensate Management Kit for down flow
Down flow Kit CMA-1 • • • • •
installation
Electric Heat Lockout Electric Heat Lockout ETC-211000-MIT • • • • •
EH10-MPA-LB • •
10kW Electric Heater
EH10-MPA-MB •
15kW Electric Heater EH15-MPAS-LB • •
17kW Electric Heater EH17-MPAS-LB •
EH03-MPA-MB •
3kW Electric Heater
Electric Kit Heats EH03-MPA-SB • •
EH05-MPA-MB • •
5kW Electric Heater
EH05-MPA-SB • •
5kW Electric Heater Module-Medium Cabinet EH05-MPA-M •
EH08-MPA-MB • •
8kW Electric Heater
EH08-MPA-SB •
Filter High Efficiency Filter Element PAC-SH59KF-E • • • • • •
i-see Sensor® Panel Grille with 3D i-see Sensor® TLP-41EAEU • • • • •
10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube
MPLS385812T-10 • • • • • • •
Insulation)
100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube
MLS141212T-100 • • • •
Insulation)
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube
MPLS385812T-100 • • • • • • •
Insulation)
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube
MLS141212T-15 • • • •
Insulation)
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube
MPLS385812T-15 • • • • • • •
Insulation)
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube
Lineset MLS141212T-30 • • • •
Insulation)
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube
MPLS385812T-30 • • • • • • •
Insulation)
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube
MLS141212T-50 • • • •
Insulation)
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube
MPLS385812T-50 • • • • • • •
Insulation)
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube
MLS141212T-65 • • • •
Insulation)
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube
MPLS385812T-65 • • • • • • •
Insulation)
Shutter Plate Drain Pan PAC-SJ37SP-E • • • • • •
Architectural Surround for Ceiling Recessed Units PLFY-ITP1 • • • • • •
Space Panel
Space Panel PAC-SJ38AS-E • • • • • •
Terminal Block Separate Terminal Power Block SPTB1 • • • • •
Appendix 141
Optional Parts List for Indoor [P-Series]
Ducted
TPEADA
TPEADA0091AA70A
TPEADA0121AA70A
TPEADA0151AA70A
TPEADA0181AA70A
TPEADA0241AA70A
TPEADA0301AA70A
TPEADA0361AA70A
TPEADA0421AA70A
Blue Diamond (Advanced) Mini Condensate
Pump w/ Reservoir & Sensor (208/230V) [recom- X87-721 • • • • • • • •
mended]
Condensate Blue Diamond (MegaBlue Advanced) Conden-
X87-835 • • • • • • • •
sate Pump w/ Reservoir & Sensor
Blue Diamond Sensor Extension Cable — 15 Ft. C13-103 • • • • • • • •
20/2PR, 1PR shielded + 1PR plenum wire for
CW2042S2-100 • • • • • • • •
Airzone, 100 ft reel
Control Wire
20/2PR, shielded + 1PR plenum wire for Airzone,
CW2042S2-500 • • • • • • • •
500 ft reel
(30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303 • • • • • • • •
Disconnect Switch
(30A/600V/UL) [fits 2” X 4” utility box] - White TAZ-MS303W • • • • • • • •
FBM2-2-A • • • •
Filter Box Filter Box with MERV 13 Filter FBM2-3-A • •
FBM2-4-A • •
10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube
MPLS385812T-10 • • • •
Insulation)
100’ x 1/4” x 100’ / 1/2” Lineset (Twin-Tube
MLS141212T-100 • • •
Insulation)
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube
MPLS385812T-100 • • • •
Insulation)
15’ x 1/4” x 15’ / 1/2” Lineset (Twin-Tube
MLS141212T-15 • • •
Insulation)
15’ x 1/4” x 15’ / 3/8” Lineset (Twin-Tube
MLS143812T-15 •
Insulation)
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube
MPLS385812T-15 • • • •
Insulation)
30’ x 1/4” x 30’ / 1/2” Lineset (Twin-Tube
MLS141212T-30 • • •
Insulation)
30’ x 1/4” x 30’ / 3/8” Lineset (Twin-Tube
Lineset MLS143812T-30 •
Insulation)
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube
MPLS385812T-30 • • • •
Insulation)
50’ x 1/4” x 50’ / 1/2” Lineset (Twin-Tube
MLS141212T-50 • • •
Insulation)
50’ x 1/4” x 50’ / 3/8” Lineset (Twin-Tube
MLS143812T-50 •
Insulation)
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube
MPLS385812T-50 • • • •
Insulation)
65’ x 1/4” x 65’ / 1/2” Lineset (Twin-Tube
MLS141212T-65 • • •
Insulation)
65’ x 1/4” x 65’ / 3/8” Lineset (Twin-Tube
MLS143812T-65 •
Insulation)
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube
MPLS385812T-65 • • • •
Insulation)
142 Appendix
Optional Parts List for Outdoor [Nv-Series]
NTXSPH NTXSPB
NTXSPH06B112AA
NTXSPH09B112AA
NTXSPH12B112AA
NTXSPH15B112AA
NTXSPH18B112AA
NTXSPB06B112AA
NTXSPB09B112AA
NTXSPB12B112AA
NTXSPB15B112AA
NTXSPB18B112AA
Air Outlet Guide Air Outlet Guide PAC-ADG881AA-E • • • • • •
M- & P-Series Maintenance Tool Cable Set M21EC0397 • • • • •
Control/Service Tool USB/UART Conversion Cable (Required for all
M21EC1397 • • • • •
laptop connection)
MAC-811DS • • •
Drain Socket Drain Socket
MAC-871DS • • • • • • •
HG-A7 • • • •
Hail Guards Hail Guard
HG-B4 • • • • • •
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 • • • • • • • • • •
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 • • • • • • • • • •
Mini-Split Wire
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 • • • • • • • • • •
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 • • • • • • • • • •
Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 • • • • • • • • • •
Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair)
DSD-400P • • • • • • • • • •
- Plastic
Optional Defrost Base Heater MAC-642BH-U1 • •
Heater Optional Defrost Heater MAC-640BH-U • • •
18” Single Fan Stand QSMS1801M • • • • • • • • • •
24” Single Fan Stand QSMS2401M • • • • • • • • • •
Stand Condenser Wall Bracket QSWB2000M-1 • • • • • • • • • •
Condenser Wall Bracket -Stainless Steel Finish QSWBSS • • • • • • • • • •
Outdoor Unit Stand — 12” High QSMS1201M • • • • • • • • • •
NTXSST NTXSMT
NTXSMT24A112AA
NTXSMT09A112AB
NTXSMT12A112AB
NTXSMT15A112AB
NTXSMT18A112AB
NTXSST18A112AA
NTXSST24A112AA
NTXSST30A112AA
NTXSST36A112AA
NTXSST09A112AB
NTXSST12A112AB
NTXSST15A112AB
PAC-ADG881AA-E • • • • • •
Air Outlet Guide Air Outlet Guide
PAC-ADG886AA-E • • •
M- & P-Series Maintenance Tool Cable Set M21EC0397 • • • • • • • • • • • •
Control/Service Tool USB/UART Conversion Cable (Required for all
M21EC1397 • • • • • • • • • • • •
laptop connection)
Controller Holder Remote Controller Holder U01A01083 •
MAC-811DS • •
Drain Socket Drain Socket
MAC-871DS • • • • • • • • •
HG-A7 • • •
Hail Guards Hail Guard
HG-B4 • • • • • •
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 • • • • • • • • • • • •
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 • • • • • • • • • • • •
Mini-Split Wire
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 • • • • • • • • • • • •
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 • • • • • • • • • • • •
Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 • • • • • • • • • • •
Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair)
DSD-400P • • • • • • • • • • •
- Plastic
Optional Defrost Base Heater MAC-642BH-U1 • • •
Heater Optional Defrost Heater MAC-640BH-U • • • • • •
Power Supplies And M-Net Control Wire, 250’ Roll (16-AWG, Stan-
Auxiliary Compo- dard, Twisted Pair, Shielded, Jacketed- Plenum CW162S-250 •
nents rated)
18” Single Fan Stand QSMS1801M • • • • • • • • • • •
24” Single Fan Stand QSMS2401M • • • • • • • • • • •
Stand Condenser Wall Bracket QSWB2000M-1 • • • • • • • • • • •
Condenser Wall Bracket -Stainless Steel Finish QSWBSS • • • • • • • • • • •
Outdoor Unit Stand — 12” High QSMS1201M • • • • • • • • • • •
144 Appendix
Optional Parts List for Outdoor [Nv-Series]
NTYSST NTXSPF
NTYSST18A112AA
NTYSST24A112AA
NTYSST30A112AA
NTYSST36A112AA
NTXSPF09A112AA
NTXSPF12A112AA
NTXSPF15A112AA
NTXSPF18A112AA
NTYSST09A112AB
NTYSST12A112AB
NTYSST15A112AB
PAC-ADG881AA-E • • • • •
Air Outlet Guide Air Outlet Guide
PAC-ADG886AA-E • • • • • •
M- & P-Series Maintenance Tool Cable Set M21EC0397 • • • • • • • • • • •
Control/Service Tool USB/UART Conversion Cable (Required for all
M21EC1397 • • • • • • • • • • •
laptop connection)
MAC-811DS • •
Drain Socket Drain Socket
MAC-871DS • • • • •
HG-A7 • • • • • •
Hail Guards Hail Guard
HG-B4 • • • • •
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 • • • • • • • • • • •
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 • • • • • • • • • • •
Mini-Split Wire
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 • • • • • • • • • • •
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 • • • • • • • • • • •
Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 • • • • • • • • • • •
Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair)
DSD-400P • • • • • • • • • • •
- Plastic
18” Single Fan Stand QSMS1801M • • • • • • • • • • •
24” Single Fan Stand QSMS2401M • • • • • • • • • • •
Stand Condenser Wall Bracket QSWB2000M-1 • • • • • • • • • • •
Condenser Wall Bracket -Stainless Steel Finish QSWBSS • • • • • • • • • • •
Outdoor Unit Stand — 12” High QSMS1201M • • • • • • • • • • •
NTXSEL NTXSMT
NTXSMT09A111AA
NTXSMT12A111AA
NTXSEL24A112AA
NTXSEL09A112AB
NTXSEL12A112AB
NTXSEL18A112AB
NTXSEL09A112A*
NTXSEL12A112A*
PAC-ADG881AA-E • • • • • • •
Air Outlet Guide Air Outlet Guide
PAC-ADG886AA-E •
M- & P-Series Maintenance Tool Cable Set M21EC0397 • • • • • •
Control/Service Tool USB/UART Conversion Cable (Required for all
M21EC1397 • • • • • •
laptop connection)
Drain Socket Drain Socket MAC-871DS • • • • • • •
HG-A7 •
Hail Guards Hail Guard
HG-B4 • • • • • • •
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 • • • • • •
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 • • • • • •
Mini-Split Wire
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 • • • • • •
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 • • • • • •
Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 • • • • • • •
Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair)
DSD-400P • • • • • • •
- Plastic
Optional Defrost Base Heater MAC-642BH-U1 •
Heater Optional Defrost Heater MAC-640BH-U • • • • •
18” Single Fan Stand QSMS1801M • • • • • • •
24” Single Fan Stand QSMS2401M • • • • • • •
Stand Condenser Wall Bracket QSWB2000M-1 • • • • • • •
Condenser Wall Bracket -Stainless Steel Finish QSWBSS • • • • • • •
Outdoor Unit Stand — 12” High QSMS1201M • • • • • • •
Appendix 145
Optional Parts List for Outdoor [Nv-Series]
NTXMMX NTXMPH
NTXMMX20A122A*
NTXMMX24A132A*
NTXMMX30A132A*
NTXMMX36A142A*
NTXMMX42A152A*
NTXMMX48A182B*
NTXMMX60A182B*
NTXMPH20A122A*
NTXMPH24A132A*
NTXMPH30A132A*
NTXMPH36A142B*
NTXMPH42A152B*
NTXMPH48A182B*
PAC-ADG007AA-E •
Air Outlet Guide
Air Outlet Guide PAC-ADG856AA-E •
Air Outlet Guide (1 Piece) PAC-ADG096AA-E • • • • • • • • • • •
Refrigeration Ball Valve - 1/2” BV12FFSI2 • • • • • • • • • • • •
Refrigeration Ball Valve - 1/4” BV14FFSI2 • • • • • • • • • • • •
Ball Valve
Refrigeration Ball Valve - 3/8” BV38FFSI2 • • • • • • • • • • • •
Refrigeration Ball Valve - 5/8” BV58FFSI2 • • • • • • • • • • • •
TAC-MKA32BC • • • • •
Branch Box
Branch Box TAC-MKA52BC • • • • •
Branch Box Enclosure BBE-1 • • • • •
Centralized Drain Pan Drain Pan PAC-SH97DP-E • • • • • •
M- & P-Series Maintenance Tool Cable Set M21EC0397 • • • • •
Control/Service Tool Maintenance Tool Interface PAC-USCMS-MN-1 • • • • •
USB/UART Conversion Cable (Required for all
M21EC1397 • • • • •
laptop connection)
Brazed Connection MSDD-50BR-E • • • • •
Distribution pipe for
Flare Connection MSDD-50AR-E • • • • •
Branch Box
M-NET Converter PAC-IF01MNT-E • • • • • • •
MAC-811DS •
Drain Socket Drain Socket PAC-SG60DS-E • • • •
PAC-SG61DS-E •
HG-A1 • • • •
HG-A2 • • • • • •
Hail Guards Hail Guard
HG-A8 •
HG-A9 • •
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 • • • • •
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 • • • • •
Mini-Split Wire
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 • • • • •
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 • • • • •
Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 • • • • • • • • • • •
Mounting Pad Condensing Unit Mounting Pad: 24” x 42” x 3” ULTRILITE2 • • • •
Outdoor Unit 3-1/4 inch Mounting Base (Pair)
DSD-400P • • • • • • • • • • • • •
- Plastic
Base Heater PAC-646BH-E • • •
Optional Defrost
PAC-645BH-E • •
Heater Optional Defrost Heater
PAC-SJ20BH-E • •
Adaptor: 1/2” x 3/8” MAC-A455JP-E • • • • • • • • • • • • •
Adaptor: 1/2” x 5/8” MAC-A456JP-E • • • • • • • • • • • • •
Port Adapter
Adaptor: 3/8” x 1/2” MAC-A454JP-E • • • • • • • • • • • • •
Adaptor: 3/8” x 5/8” PAC-SG76RJ-E • • • • • • • • • • • • •
Power Supplies and M-Net Control Wire, 1,000’ Roll (16-AWG,
Auxiliary Compo- Standard, Twisted Pair, Shielded, Jacketed- Ple- CW162S-1000 • • • • • •
nents num rated)
Power Supplies And M-Net Control Wire, 250’ Roll (16-AWG, Stan-
Auxiliary Compo- dard, Twisted Pair, Shielded, Jacketed- Plenum CW162S-250 • • • • • •
nents rated)
18” Dual Fan Stand QSMS1802M • • • • •
18” Single Fan Stand QSMS1801M • • • • • • •
24” Dual Fan Stand QSMS2402M • • • • • •
24” Single Fan Stand QSMS2401M • • • • • • •
Stand
Condenser Wall Bracket QSWB2000M-1 • • • • • • • • • • • • •
Condenser Wall Bracket -Stainless Steel Finish QSWBSS • • • • • • • • • • • • •
QSMS1201M • • • • • • •
Outdoor Unit Stand — 12” High
QSMS1202M • • • • • •
Wind Baffle Front Wind Baffle WB-PA3 • • • • •
146 Appendix
Optional Parts List for Outdoor [Nv-Series]
NTXSKS NTXSKH
NTXSKH09A112AA
NTXSKH12A112AA
NTXSKH15A112AA
NTXSKH18A112AA
NTXSKH24A112AA
NTXSKH30A112AA
NTXSKH36A112AA
NTXSKS09A112AA
NTXSKS12A112AA
NTXSKS15A112AA
NTXSKS18A112AA
NTXSKS24A112AA
NTXSKS30A112AA
NTXSKS36A112AA
Air Outlet Guide PAC-ADG886AA-E • • • • •
Air Outlet Guide PAC-ADG059AA-E •
Air Outlet Guide (1 Piece)
PAC-ADG096AA-E • •
PAC-SG64DS-E •
Centralized Drain Pan Drain Pan
PAC-SH97DP-E • •
M- & P-Series Maintenance Tool Cable Set M21EC0397 • • • • • • • • • • • • • •
Control/Service Tool USB/UART Conversion Cable (Required for all
M21EC1397 • • • • • • • • •
laptop connection)
Drain Socket Drain Socket PAC-SH71DS-E • • •
HG-A2 • •
Hail Guards Hail Guard HG-A6 •
HG-B4 • • •
S144-250 • • • • • • • • • • • • •
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll
SW144-250 • • • • • • • • • • •
S144-50 • • • • • • • • • • • • •
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll
SW144-50 • • • • • • • • • • •
Mini-Split Wire
S164-250 • • • • • • • • • • • • •
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll
SW164-250 • • • • • • • • • • •
S164-50 • • • • • • • • • • • • •
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll
SW164-50 • • • • • • • • • •
Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 • • • • • • • • • • •
Mounting Pad Condensing Unit Mounting Pad: 24” x 42” x 3” ULTRILITE2 • • •
Outdoor Unit 3-1/4 inch Mounting Base (Pair)
DSD-400P • • • • • • •
- Plastic
Optional Defrost
Base Heater MAC-642BH-U1 • • • • •
Heater
Port Adapter Adaptor: 3/8” x 1/2” MAC-A454JP-E • •
18” Dual Fan Stand QSMS1802M • •
18” Single Fan Stand QSMS1801M • • • • • • • • • • • •
24” Dual Fan Stand QSMS2402M • •
Stand 24” Single Fan Stand QSMS2401M • • • • • • • • • • • •
Condenser Wall Bracket QSWB2000M-1 • • • • • • • • • • •
QSMS1201M • • • • • • • • • • • •
Outdoor Unit Stand — 12” High
QSMS1202M • •
Appendix 147
Optional Parts List for Outdoor [P-Series]
TRUYA
TRUYA0241HA70(N/B)A
TRUYA0301HA70(N/B)A
TRUYA0121KA70(N/B)A
TRUYA0181KA70(N/B)A
TRUYA0361KA70(N/B)A
TRUYA0421KA70(N/B)A
Air Outlet Guide PAC-ADG007AA-E • •
Air Outlet Guide PAC-ADG059AA-E • •
Air Outlet Guide (1 Piece)
PAC-ADG096AA-E • •
Centralized Drain Pan PAC-SG63DP-E • •
Centralized Drain Pan
Drain Pan PAC-SG64DP-E • •
Control/Service Tool PAC-SK52ST • • • • • •
Control/Service Tool M- & P-Series Maintenance Tool Cable Set M21EC0397 • • • • • •
USB/UART Conversion Cable (Required for all
M21EC1397 • • • • • •
laptop connection)
Distribution pipe Twinning Distribution Pipe (50:50) MSDD-50TR-E • •
PAC-SG61DS-E • • • •
Drain Socket Drain Socket
PAC-SJ08DS-E • •
HG-A5 • •
Hail Guards Hail Guard
HG-A6 • •
PAC-SJ85MA-E • • • •
M-NET Converter M-NET Converter PAC-SJ95MA-E • • • •
PAC-SJ96MA-E • •
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 • • • • • •
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 • • • • • •
Mini-Split Wire
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 • • • • • •
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 • • • • • •
Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 • •
Mounting Pad
Condensing Unit Mounting Pad: 24” x 42” x 3” ULTRILITE2 • • • •
18” Dual Fan Stand QSMS1802M • •
18” Single Fan Stand QSMS1801M • • • •
24” Dual Fan Stand QSMS2402M • •
24” Single Fan Stand QSMS2401M • • • •
Stand
Condenser Wall Bracket QSWB2000M-1 • • • • • •
Condenser Wall Bracket -Stainless Steel Finish QSWBSS • • • • • •
QSMS1201M • • • •
Outdoor Unit Stand — 12” High
QSMS1202M • •
WB-PA3 • •
Front Wind Baffle WB-PA4 • •
WB-PA5 • •
WB-RE4 • •
Wind Baffle Rear Wind Baffle WB-RE5 • •
WB-RE6 • •
WB-SD4 • •
Side Advanced Wind Baffle WB-SD5 • •
WB-SD6 • •
148 Appendix
Optional Parts List for Outdoor [P-Series]
TRUZA TRUZH
TRUZA0241HA70(N/B)A
TRUZA0301HA70(N/B)A
TRUZA0121KA70(N/B)A
TRUZA0181KA70(N/B)A
TRUZA0361KA70(N/B)A
TRUZA0421KA70(N/B)A
TRUZH0241HA10NA
TRUZH0301KA00NA
TRUZH0361KA00NA
TRUZH0421KA10NA
Air Outlet Guide PAC-ADG007AA-E • •
Air Outlet Guide PAC-ADG059AA-E • • • •
Air Outlet Guide (1 Piece)
PAC-ADG096AA-E • • • • •
Centralized Drain Pan PAC-SG63DP-E • •
Centralized Drain Pan PAC-SG64DP-E • • •
Drain Pan
PAC-SH97DP-E • • •
Control/Service Tool PAC-SK52ST • • • • • • • • • •
Control/Service Tool M- & P-Series Maintenance Tool Cable Set M21EC0397 • • • • • •
USB/UART Conversion Cable (Required for all
M21EC1397 • • • • • •
laptop connection)
Distribution pipe Twinning Distribution Pipe (50:50) MSDD-50TR-E • •
PAC-SG61DS-E • • • • • • • •
Drain Socket Drain Socket
PAC-SJ08DS-E • •
HG-A2 • • •
Hail Guards Hail Guard HG-A5 • •
HG-A6 • • •
PAC-SJ85MA-E • • • • • • • •
M-NET Converter M-NET Converter PAC-SJ95MA-E • • • • • • • •
PAC-SJ96MA-E • •
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 • • • • • •
14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 • • • • • •
Mini-Split Wire
16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 • • • • • •
16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50 • • • • • •
Condensing Unit Mounting Pad: 16” x 36” x 3” ULTRILITE1 • •
Mounting Pad
Condensing Unit Mounting Pad: 24” x 42” x 3” ULTRILITE2 • • • • • • • •
Optional Defrost
Optional Defrost Heater PAC-SJ20BH-E • • •
Heater
18” Dual Fan Stand QSMS1802M • • • • •
18” Single Fan Stand QSMS1801M • • • • •
24” Dual Fan Stand QSMS2402M • • • • •
24” Single Fan Stand QSMS2401M • • • • •
Stand
Condenser Wall Bracket QSWB2000M-1 • • • • • • • • • •
Condenser Wall Bracket -Stainless Steel Finish QSWBSS • • • • • • • • • •
QSMS1201M • • • • •
Outdoor Unit Stand — 12” High
QSMS1202M • • • • •
WB-PA3 • • • • •
Front Wind Baffle WB-PA4 • •
WB-PA5 • • •
WB-RE4 • •
Wind Baffle Rear Wind Baffle WB-RE5 • • •
WB-RE6 • •
WB-SD4 • •
Side Advanced Wind Baffle WB-SD5 • • •
WB-SD6 • •
Appendix 149
Optional Parts List for Controllers
Wall-mount
NTXWPH MSZ-EF
MSZ-EF09NA(B/S/W)
MSZ-EF12NA(B/S/W)
MSZ-EF15NA(B/S/W)
MSZ-EF18NA(B/S/W)
NTXWPH06B112AA
NTXWPH09B112AA
NTXWPH12B112AA
NTXWPH15B112AA
NTXWPH18B112AA
BACnet® and Modbus Interface PAC-UKPRC001-CN-1 • • • • • • • • •
CN24 Relay Kit CN24RELAY-KIT-CM3 • • • • •
IT Extender PAC-WHS01IE-E • • • • • • • • •
kumo station® for kumo cloud® TAC-WHS01HC-E • • • • • • • • •
Control Interface Lockdown bracket for remote controller RCMKP1CB • • • • • • • • •
System Control Interface MAC-334IF-E • • • • • • • • •
Thermostat Interface PAC-US444CN-1 • • • • • • • • •
USNAP Adapter PAC-WHS01UP-E • • • • • • • • •
Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 • • • • •
Wired Remote Sensor M21EAA307 • • • • •
Remote Sensor Wireless temperature and humitity sensor for
PAC-USWHS003-TH-1 • • • • • • • • •
kumo cloud®
Deluxe Wired MA Remote Controller† TAR-40MAAU • • • • • • • • •
Wired Remote
Simple MA Remote Controller† TAC-YT53CRAU-J • • • • • • • • •
Controller
Touch MA Controller† TAR-CT01MAU-SB • • • • • • • • •
Wireless Remote
kumo touch™ RedLINK™ Wireless Controller MHK2 • • • • • • • • •
Controller
Wall-mount
NTXWST
NTXWST06A112AA
NTXWST09A112AA
NTXWST12A112AA
NTXWST15A112AA
NTXWST18A112AA
NTXWST24A112AA
NTXWST30A112AA
NTXWST36A112AA
BACnet® and Modbus Interface PAC-UKPRC001-CN-1 • • • • • • •
IT Extender PAC-WHS01IE-E • •
kumo station® for kumo cloud® TAC-WHS01HC-E • • • • •
Lockdown bracket for remote controller RCMKP1CB • • • • • • • •
Control Interface
System Control Interface MAC-334IF-E • • • • • • • •
Thermostat Interface PAC-US444CN-1 • •
USNAP Adapter PAC-WHS01UP-E • •
Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 • • • • • • •
Wired Remote Sensor M21EAA307 • • • • •
Remote Sensor Wireless temperature and humitity sensor for
PAC-USWHS003-TH-1 • • • • • • • •
kumo cloud®
Deluxe Wired MA Remote Controller† TAR-40MAAU • • • • • • • •
Wired Remote
Simple MA Remote Controller† TAC-YT53CRAU-J • • • • • • • •
Controller
Touch MA Controller† TAR-CT01MAU-SB • • • • • • • •
Wireless Remote
kumo touch™ RedLINK™ Wireless Controller MHK2 • • • • • • • •
Controller
150 Appendix
Optional Parts List for Controllers Wall-mount
NTXWMT NTXWEL
NTXWMT09A112AA
NTXWMT12A112AA
NTXWMT15A112AA
NTXWMT18A112AA
NTXWMT24A112AA
NTXWMT09A111AA
NTXWMT12A111AA
NTXWEL09A112AA
NTXWEL12A112AA
NTXWEL18A112AA
NTXWEL24A112AA
BACnet® and Modbus Interface PAC-UKPRC001-CN-1 • • • • • • • • • • •
IT Extender PAC-WHS01IE-E • • • • • • • • • • •
kumo station® for kumo cloud® TAC-WHS01HC-E • • • • • • • • • • •
Lockdown bracket for remote controller RCMKP1CB • • • • • • • • •
Control Interface
System Control Interface MAC-334IF-E • • • • • • • • • • •
Thermostat Interface PAC-US444CN-1 • • • • • • • • • • •
USNAP Adapter PAC-WHS01UP-E • • • • • • • • • • •
Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 • • • • • • • • • • •
Wired Remote Sensor M21EAA307 • • • • • • •
Remote Sensor Wireless temperature and humitity sensor for
PAC-USWHS003-TH-1 • • • • • • • • • • •
kumo cloud®
Deluxe Wired MA Remote Controller† TAR-40MAAU • • • • • • • • • • •
Wired Remote
Simple MA Remote Controller† TAC-YT53CRAU-J • • • • • • • • • • •
Controller
Touch MA Controller† TAR-CT01MAU-SB • • • • • • • • • • •
Wireless Remote
kumo touch™ RedLINK™ Wireless Controller MHK2 • • • • • • • • • • •
Controller
Wall-mount
NTYWST
NTYWST09A112AA
NTYWST12A112AA
NTYWST15A112AA
NTYWST18A112AA
NTYWST24A112AA
NTYWST30A112AA
NTYWST36A112AA
BACnet® and Modbus Interface PAC-UKPRC001-CN-1 • • • • • • •
IT Extender PAC-WHS01IE-E • •
kumo station® for kumo cloud® TAC-WHS01HC-E • • • •
Lockdown bracket for remote controller RCMKP1CB • • • • • • •
Control Interface
System Control Interface MAC-334IF-E • • • • • •
Thermostat Interface PAC-US444CN-1 • •
USNAP Adapter PAC-WHS01UP-E • •
Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 • • • • • • •
Wired Remote Sensor M21EAA307 • • • • • •
Remote Sensor Wireless temperature and humitity sensor for
PAC-USWHS003-TH-1 • • • • • • •
kumo cloud®
Deluxe Wired MA Remote Controller† TAR-40MAAU • • • • • • •
Wired Remote
Simple MA Remote Controller† TAC-YT53CRAU-J • • • • • • •
Controller
Touch MA Controller† TAR-CT01MAU-SB • • • • • • •
Wireless Remote
kumo touch™ RedLINK™ Wireless Controller MHK2 • • • • • • •
Controller
NTXUKS12A112AA
NTXUKS18A112AA
NTXFKS09A112AA
NTXFKS12A112AA
NTXFKS15A112AA
NTXFKS18A112AA
Appendix 151
Optional Parts List for Controllers
Residential Multi-position
Four-way Cassette Ducted
AHU
NTXCKS NTXDKS NTXAMT
NTXAMT12A112AA
NTXAMT18A112AA
NTXAMT24A112AA
NTXAMT30A112AA
NTXAMT36A112AA
NTXDKS09A112AA
NTXDKS12A112AA
NTXDKS15A112AA
NTXDKS18A112AA
NTXCKS09A112AA
NTXCKS12A112AA
NTXCKS15A112AA
NTXCKS18A112AA
3-Pin Connector PAC-715AD • • • • • • • •
BACnet® and Modbus Interface PAC-UKPRC001-CN-1 • • • • • • • • • • • • •
CN24 Relay Kit CN24RELAY-KIT-CM3 • • • • • • • • • • • • •
Connector and wire for Operation status/error
PAC-725AD • • • • • • • •
using CN51
Connector cable for remote display PAC-SA88HA-EP • • • • • • • • • • • • •
Control Interface IT Extender PAC-WHS01IE-E • • • • • • • • • • • • •
kumo station® for kumo cloud® TAC-WHS01HC-E • • • • • • • • • • • • •
Lockdown bracket for remote controller RCMKP1CB • • • •
Remote Operation Adapter‡ PAC-SF40RM-E • • • • • • • • • • • • •
Thermostat Interface PAC-US444CN-1 • • • • • • • • • • • • •
USNAP Adapter PAC-WHS01UP-E • • • • • • • • • • • • •
Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 • • • • • • • • • • • • •
Flush Mount Temperature Sensor PAC-USSEN001-FM-1 • • • • • • • • • • • • •
Remote Sensor Remote Temperature Sensor surface mount PAC-SE41TS-E • • • • • • • • • • • • •
Wireless temperature and humitity sensor for
PAC-USWHS003-TH-1 • • • • • • • • • • • • •
kumo cloud®
Airzone ZBS Wired Blueface Principal Controller
AZZBSBLUEFACECB • • • • • • • • •
White
Airzone ZBS Wired Lite Controller White AZZBSLITECB • • • • • • • • •
Airzone ZBS Wired Think Controller White AZZBSTHINKCB • • • • • • • • •
Wired Remote Airzone ZBS Wireless Lite Controller White AZZBSLITERB • • • • • • • • •
Controller
Airzone ZBS Wireless Think Controller White AZZBSTHINKRB • • • • • • • • •
Deluxe Wired MA Remote Controller† TAR-40MAAU • • • • • • • • • • • • •
Simple MA Remote Controller† TAC-YT53CRAU-J • • • • • • • • • • • • •
Touch MA Controller† TAR-CT01MAU-SB • • • • • • • • • • • • •
kumo touch™ RedLINK™ Wireless Controller MHK2 • • • • • • • • • • • • •
Wireless MA Receiver PAR-SR32MA-E • • • • • • • • • • • • •
Wireless Remote Wireless MA Remote Controller TAR-FL32MA-E • • • • • • • • •
Controller Wireless Receiver PAR-WSC009FA-E • • • •
Wireless Remote Contoller PAR-SL100A-E • • • •
Wireless Signal Receiver TAR-SA9CA-E • • • •
TPKA0A0181HA70A
TPKA0A0241KA70A
TPKA0A0301KA70A
TPKA0A0361KA70A
TPCA0A0241KA70A
TPCA0A0301KA70A
TPCA0A0361KA70A
TPCA0A0421KA70A
152 Appendix
Four-way Cassette Residential Multi-position AHU
TPLA TPVA
TPVA0A0121AA70A
TPVA0A0181AA70A
TPVA0A0241AA70A
TPVA0A0301AA70A
TPVA0A0421AA70A
TPLA0A0121EA70A
TPLA0A0181EA70A
TPLA0A0241EA70A
TPLA0A0301EA70A
TPLA0A0361EA70A
TPLA0A0421EA70A
3-Pin Connector PAC-715AD • • • • • • • • • • •
BACnet® and Modbus Interface PAC-UKPRC001-CN-1 • • • • • • • • • •
CN24 Relay Kit CN24RELAY-KIT-CM3 • • • • • • • • • • •
Connector cable for remote display PAC-SA88HA-EP • • • • •
IT Extender PAC-WHS01IE-E • • • • • • • • • •
Control Interface kumo station® for kumo cloud® TAC-WHS01HC-E • • • • • • • • • • •
Lockdown bracket for remote controller RCMKP1CB • • • • • • • • • • •
Remote Operation Adapter‡ PAC-SF40RM-E • • • • • • • • • • •
Thermostat Interface PAC-US444CN-1 • • • • • • • • • • •
USNAP Adapter PAC-WHS01UP-E • • • • • • • • • • •
Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 • • • • • •
Flush Mount Temperature Sensor PAC-USSEN001-FM-1 • • • • • • • • • • •
Remote Sensor Remote Temperature Sensor surface mount PAC-SE41TS-E • • • • • • • • • • •
Wireless temperature and humitity sensor for
PAC-USWHS003-TH-1 • • • • • • • • • • •
kumo cloud®
Airzone ZBS Wired Blueface Principal Controller
AZZBSBLUEFACECB • • • • •
White
Airzone ZBS Wired Lite Controller White AZZBSLITECB • • • • •
Airzone ZBS Wired Think Controller White AZZBSTHINKCB • • • •
Wired Remote Airzone ZBS Wireless Lite Controller White AZZBSLITERB • • • • •
Controller
Airzone ZBS Wireless Think Controller White AZZBSTHINKRB • • • • •
Deluxe Wired MA Remote Controller† TAR-40MAAU • • • • • • • • • • •
Simple MA Remote Controller† TAC-YT53CRAU-J • • • • • • • • • • •
Touch MA Controller† TAR-CT01MAU-SB • • • • • • • • • • •
kumo touch™ RedLINK™ Wireless Controller MHK2 • • • • • • • • • • •
Wireless MA Receiver PAR-SR32MA-E • • • • •
Wireless Remote Wireless MA Remote Controller TAR-FL32MA-E • • • • •
Controller Wireless Remote Contoller PAR-SL100A-E • • • • • • • • • • •
Wireless Signal Receiver TAR-SA9CA-E • • • •
Wireless Signal Receiver Panel PAR-SR4LU-E • • • • • •
Ducted
TPEADA
TPEADA0091AA70A
TPEADA0121AA70A
TPEADA0151AA70A
TPEADA0181AA70A
TPEADA0241AA70A
TPEADA0301AA70A
TPEADA0361AA70A
TPEADA0421AA70A
3-Pin Connector PAC-715AD • • • • • • •
BACnet® and Modbus Interface PAC-UKPRC001-CN-1 • • • • • • • •
CN24 Relay Kit CN24RELAY-KIT-CM3 • • • • • • • •
Connector cable for remote display PAC-SA88HA-EP • • • • • • • •
IT Extender PAC-WHS01IE-E • • • • • • • •
Control Interface kumo station® for kumo cloud® TAC-WHS01HC-E • • • • • • • •
Lockdown bracket for remote controller RCMKP1CB • • • • • • • •
Remote Operation Adapter‡ PAC-SF40RM-E • • • • • • • •
Thermostat Interface PAC-US444CN-1 • • • • • • • •
USNAP Adapter PAC-WHS01UP-E • • • • • • • •
Wireless Interface for kumo cloud® PAC-USWHS002-WF-2 • • • • • • •
Flush Mount Temperature Sensor PAC-USSEN001-FM-1 • • • • • • • •
Remote Sensor Remote Temperature Sensor surface mount PAC-SE41TS-E • • • • • • • •
Wireless temperature and humitity sensor for
PAC-USWHS003-TH-1 • • • • • • • •
kumo cloud®
Airzone ZBS Wired Blueface Principal Controller
AZZBSBLUEFACECB • • • • • • • •
White
Airzone ZBS Wired Lite Controller White AZZBSLITECB • • • • • • • •
Airzone ZBS Wired Think Controller White AZZBSTHINKCB • • • • • • • •
Wired Remote Airzone ZBS Wireless Lite Controller White AZZBSLITERB • • • • • • • •
Controller
Airzone ZBS Wireless Think Controller White AZZBSTHINKRB • • • • • • • •
Deluxe Wired MA Remote Controller† TAR-40MAAU • • • • • • • •
Simple MA Remote Controller† TAC-YT53CRAU-J • • • • • • • •
Touch MA Controller† TAR-CT01MAU-SB • • • • • • • •
kumo touch™ RedLINK™ Wireless Controller MHK2 • • • • • • • •
Wireless Remote Wireless MA Receiver PAR-SR32MA-E • • • • • • • •
Controller Wireless MA Remote Controller TAR-FL32MA-E • • • • • • •
Wireless Signal Receiver TAR-SA9CA-E • • • • • • • •
Appendix 153
Additional Nv-Series Information
Port Adapters Parts Numbers
Model Name Diameter A Diameter B
MAC-A454JP-E 3/8" 1/2"
MAC-A455JP-E 1/2" 3/8"
MAC-A456JP-E 1/2" 5/8"
PAC-SG76RJ-E 3/8" 5/8"
ADP5834 5/8" 3/4"
PAC-493PI 1/4" 3/8" Diameter A = Female Diameter B = Male
154 Appendix
Nv-Series Air Outlet Coverage Range*
Model Mode Function Airflow (CFM) Coverage (FT)
HEAT DRY 437 29.8
NTXWPH06B112A*, NTXWPH09B112A*
COOL WET 328 22.5
HEAT DRY 454 31.0
NTXWPH12B112A*
COOL WET 364 24.8
HEAT DRY 514 34.9
NTXWPH15B112A*
COOL WET 376 25.6
HEAT DRY 514 34.9
NTXWPH18B112A*
COOL WET 376 25.6
NTXWST06/09/12A112A*, NTYW- HEAT DRY 406 29.5
ST06/09/12A112A* COOL WET 286 21.0
HEAT DRY 463 33.5
NTXWST15A112A*, NTYWST15A112A*
COOL WET 385 28.0
HEAT DRY 646 44.0
NTXWST18A112A*, NTYWST18A112A*
COOL WET 581 39.7
HEAT DRY 738 36.9
NTXWST24A112A*, NTYWST24A112A*
COOL WET 661 33.2
HEAT DRY 848 45.0
NTXWST30/36A112A*, NTYWST30/36A112A*
COOL WET 763 40.7
HEAT DRY 417 29.6
NTXFKS09A112A*, NTXFKS12A112A*
COOL WET 354 25.3
HEAT DRY 470 33.3
NTXFKS15A112A*
COOL WET 366 26.2
HEAT DRY 470 33.3
NTXFKS18A112A*
COOL WET 417 29.7
HEAT DRY 300 15.1
NTXCKS09A112A*
COOL WET 270 13.7
HEAT DRY 336 16.9
NTXCKS12A112A*
COOL WET 302 15.2
HEAT DRY 405 20.3
NTXCKS15A112A*
COOL WET 365 18.3
HEAT DRY 475 23.7
NTXCKS18A112A*
COOL WET 429 21.4
HEAT DRY 420 29.2
MSZ-EF09NAW(B)(S)
COOL WET 319 22.3
HEAT DRY 448 31.1
MSZ-EF12NAW(B)(S)
COOL WET 319 22.3
HEAT DRY 448 31.1
MSZ-EF15NAW(B)(S)
COOL WET 313 21.9
HEAT DRY 466 32.3
MSZ-EF18NAW(B)(S)
COOL WET 334 23.4
HEAT DRY 406 29.5
NTXWMT09A112A*, NTXWMT12A112A*
COOL WET 286 21.0
HEAT DRY 463 33.5
NTXWMT15A112A*
COOL WET 385 28.0
HEAT DRY 625 42.6
NTXWMT18A112A*
COOL WET 562 38.4
HEAT DRY 702 47.7
NTXWMT24A112A*
COOL WET 632 43.1
HEAT DRY 406 29.5
NTXWMT09A111A*
COOL WET 364 26.5
HEAT DRY 406 29.5
NTXWMT12A111A*
COOL WET 364 26.5
HEAT DRY 406 29.5
NTXWEL09A112A*
COOL WET 286 21.0
HEAT DRY 406 29.5
NTXWEL12A112A*
COOL WET 286 21.0
HEAT DRY 625 42.6
NTXWEL18A112A*
COOL WET 562 38.4
HEAT DRY 702 47.7
NTXWEL24A112A*
COOL WET 632 43.1
HEAT DRY 311 20.7
NTXUKS09A112A*
COOL WET 325 21.7
HEAT DRY 332 22.1
NTXUKS12A112A*
COOL WET 350 23.3
HEAT DRY 403 26.7
NTXUKS18A112A*
COOL WET 417 27.6
Appendix 155
Heating Capacity
Outdoor Temperature Degrees 50º F 41º F 32º F 23º F 14º F 5º F -4º F -13º F
Heating Capacity (BTU/H) 14,445 13,703 12,962 12,149 11,037 9,924 8,700 7,721
NTXWPH06B112AA / NTXSPH06B112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 100% 89%
Heating Capacity (BTU/H) 14,445 13,703 12,962 12,149 11,037 9,924 8,700 7,721
NTXWPH06B112AA / NTXSPB06B112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 100% 89%
Heating Capacity (BTU/H) 18,554 17,631 16,707 15,068 13,304 11,540 9,600 8,048
NTXWPH09B112AA / NTXSPH09B112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 100% 84%
Heating Capacity (BTU/H) 18,554 17,631 16,707 15,068 13,304 11,540 9,600 8,048
NTXWPH09B112AA / NTXSPB09B112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 100% 84%
Heating Capacity (BTU/H) 21,714 20,524 19,333 18,143 16,464 14,482 12,301 10,556
NTXWPH12B112AA / NTXSPH12B112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 100% 86%
Heating Capacity (BTU/H) 21,714 20,524 19,333 18,143 16,464 14,482 12,301 10,556
NTXWPH12B112AA / NTXSPB12B112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 100% 86%
Heating Capacity (BTU/H) 24,544 23,637 22,730 21,823 19,988 18,089 16,001 14,330
NTXWPH15B112AA / NTXSPH15B112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 100% 90%
Heating Capacity (BTU/H) 24,544 23,637 22,730 21,823 19,988 18,089 16,001 14,330
NTXWPH15B112AA / NTXSPB15B112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 100% 90%
Heating Capacity (BTU/H) 30,619 29,587 28,556 27,524 25,129 22,211 19,001 16,433
NTXWPH18B112AA / NTXSPH18B112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 100% 86%
Heating Capacity (BTU/H) 30,619 29,587 28,556 27,524 25,129 22,211 19,001 16,433
NTXWPH18B112AA / NTXSPB18B112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 100% 86%
Heating Capacity (BTU/H) 10,900 10,900 10,900 10,460 9,480 8,170 6,860 -
NTXWST09A112AA / NTXSST09A112AB
Percentage of Rated Capacity 100% 100% 100% 96% 87% 75% 63% -
Heating Capacity (BTU/H) 14,400 14,400 14,110 12,960 11,660 9,790 7,920 -
NTXWST12A112AA / NTXSST12A112AB
Percentage of Rated Capacity 100% 100% 98% 90% 81% 68% 55% -
Heating Capacity (BTU/H) 18,000 17,100 16,920 16,920 16,200 13,680 11,160 -
NTXWST15A112AA / NTXSST15A112AB
Percentage of Rated Capacity 100% 95% 94% 94% 90% 76% 62% -
Heating Capacity (BTU/H) 21,600 21,600 21,600 19,440 17,060 14,900 12,520 -
NTXWST18A112AA / NTXSST18A112AA
Percentage of Rated Capacity 100% 100% 100% 90% 79% 69% 58% -
Heating Capacity (BTU/H) 27,600 27,600 27,600 26,220 23,460 19,320 15,450 -
NTXWST24A112AA / NTXSST24A112AA
Percentage of Rated Capacity 100% 100% 100% 95% 85% 70% 56% -
Heating Capacity (BTU/H) 10,900 10,570 9,480 8,500 7,300 5,990 4,680 -
NTXWMT09A112AA / NTXSMT09A112AB
Percentage of Rated Capacity 100% 97% 87% 78% 67% 55% 43% -
Heating Capacity (BTU/H) 12,200 12,200 11,220 10,120 9,020 7,440 5,850 -
NTXWMT12A112AA / NTXSMT12A112AB
Percentage of Rated Capacity 100% 100% 92% 83% 74% 61% 48% -
Heating Capacity (BTU/H) 18,000 15,300 14,940 14,400 13,680 12,240 10,620 -
NTXWMT15A112AA / NTXSMT15A112AB
Percentage of Rated Capacity 100% 85% 83% 80% 76% 68% 59% -
Heating Capacity (BTU/H) 18,000 18,000 18,000 16,560 14,580 12,780 10,980 -
NTXWMT18A112AA / NTXSMT18A112AB
Percentage of Rated Capacity 100% 100% 100% 92% 81% 71% 61% -
Heating Capacity (BTU/H) 26,000 24,440 22,360 20,020 17,680 15,600 13,260 -
NTXWMT24A112AA / NTXSMT24A112AA
Percentage of Rated Capacity 100% 94% 86% 77% 68% 60% 51% -
Heating Capacity (BTU/H) 10,900 10,570 9,480 8,500 7,300 5,990 4,680 -
NTXWMT09A111AA / NTXSMT09A111AA
Percentage of Rated Capacity 100% 97% 87% 78% 67% 55% 43% -
Heating Capacity (BTU/H) 12,200 12,200 11,220 10,120 9,020 7,440 5,850 -
NTXWMT12A111AA / NTXSMT12A111AA
Percentage of Rated Capacity 100% 100% 92% 83% 74% 61% 48% -
Heating Capacity (BTU/H) 11,000 11,000 11,000 11,000 11,000 11,000 9,130 7,26083%
NTXFKS09A112AA / NTXSPF09A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 83% 66%
156 Appendix
Heating Capacity
Outdoor Temperature Degrees 50º F 41º F 32º F 23º F 14º F 5º F -4º F -13º F
Heating Capacity (BTU/H) 13,000 13,000 13,000 13,000 13,000 13,000 10,790 8,450
NTXFKS12A112AA / NTXSPF12A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 83% 65%
Heating Capacity (BTU/H) 18,000 18,000 18,000 18,000 18,000 18,000 14,940 13,860
NTXFKS15A112AA / NTXSPF15A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 83% 77%
Heating Capacity (BTU/H) 21,000 21,000 21,000 21,000 21,000 21,000 18,480 15,960
NTXFKS18A112AA / NTXSPF18A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 88% 76%
Heating Capacity (BTU/H) 12,000 10,620 9,230 7,840 6,450 5,090 3,770 -
NTXUKS09A112AA / NTXSKS09A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 15,400 13,630 11,850 10,060 8,280 6,540 4,840 -
NTXUKS12A112AA / NTXSKS12A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 20,000 17,700 15,390 13,060 10,760 8,490 6,290 -
NTXUKS18A112AA / NTXSKS18A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 11,000 9,730 8,460 7,180 5,920 4,670 3,460 -
NTXCKS09A112AA / NTXSKS09A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 13,000 11,510 10,000 8,490 6,990 5,520 4,080 -
NTXCKS12A112AA / NTXSKS12A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 18,000 15,930 13,850 11,760 9,680 7,640 5,660 -
NTXCKS15A112AA / NTXSKS15A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 19,700 17,440 15,150 12,870 10,600 8,370 6,190 -
NTXCKS18A112AA / NTXSKS18A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 12,000 10,620 9,230 7,840 6,450 5,090 3,770 -
NTXDKS09A112AA / NTXSKS09A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 15,000 13,280 11,540 9,800 8,070 6,370 4,710 -
NTXDKS12A112AA / NTXSKS12A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 18,000 15,930 13,850 11,760 9,680 7,640 5,660 -
NTXDKS15A112AA / NTXSKS15A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 21,600 19,120 16,620 14,110 11,620 9,170 6,790 -
NTXDKS18A112AA / NTXSKS18A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 12,000 10,620 9,230 7,840 6,450 5,090 3,770 -
TPEADA0091AA70A / NTXSKS09A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 15,000 13,280 11,540 9,800 8,070 6,370 4,710 -
TPEADA0121AA70A / NTXSKS12A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 18,000 15,930 13,850 11,760 9,680 7,640 5,660 -
TPEADA0151AA70A / NTXSKS15A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 21,600 19,120 16,620 14,110 11,620 9,170 6,790 -
TPEADA0181AA70A / NTXSKS18A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 15,000 13,280 11,540 9,800 8,070 6,370 4,710 -
NTXAMT12A112AA / NTXSKS12A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 21,600 19,120 16,620 14,110 11,620 9,170 6,790 -
NTXAMT18A112AA / NTXSKS18A112AA
Percentage of Rated Capacity 100% 89% 77% 65% 54% 42% 31% -
Heating Capacity (BTU/H) 12,000 12,000 12,000 12,000 12,000 12,000 8,640 5,160
NTXUKS09A112AA / NTXSKH09A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 15,000 15,000 15,000 15,000 15,000 15,000 10,800 6,450
NTXUKS12A112AA / NTXSKH12A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 28,600 18,600 18,600 18,600 18,600 18,600 13,392 7,998
NTXUKS18A112AA / NTXSKH18A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Appendix 157
Heating Capacity (Nv-Series)
Outdoor Temperature Degrees 50º F 41º F 32º F 23º F 14º F 5º F -4º F -13º F
Heating Capacity (BTU/H) 11,000 11,000 11,000 11,000 11,000 11,000 7,920 4,730
NTXCKS09A112AA / NTXSKH09A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 13,800 13,800 13,800 13,800 13,800 13,800 9,936 5,934
NTXCKS12A112AA / NTXSKH12A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 16,400 16,400 16,400 16,400 16,400 16,400 11,808 7,052
NTXCKS15A112AA / NTXSKH15A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 18,800 18,800 18,800 18,800 18,800 18,800 13,536 8,084
NTXCKS18A112AA / NTXSKH18A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 12,500 12,500 12,500 12,500 12,500 12,500 9,000 5,375
NTXDKS09A112AA / NTXSKH09A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 15,000 15,000 15,000 15,000 15,000 15,000 10,800 6,450
NTXDKS12A112AA / NTXSKH12A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 15,000 15,000 15,000 15,000 15,000 15,000 10,800 6,450
NTXDKS15A112AA / NTXSKH15A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 21,600 21,600 21,600 21,600 21,600 21,600 15,552 9,288
NTXDKS18A112AA / NTXSKH18A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 12,000 12,000 12,000 12,000 12,000 12,000 8,640 5,160
TPEADA0091AA70A / NTXSKH09A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 15,000 15,000 15,000 15,000 15,000 15,000 10,800 6,450
TPEADA0121AA70A / NTXSKH12A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 18,000 18,000 18,000 18,000 18,000 18,000 12,960 7,740
TPEADA0151AA70A / NTXSKH15A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 21,600 21,600 21,600 21,600 21,600 21,600 15,552 9,288
TPEADA0181AA70A / NTXSKH18A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 25,000 25,000 25,000 25,000 25,000 25,000 22,250 20,000
TPEADA0241AA70A / NTXSKH24A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 89% 80%
Heating Capacity (BTU/H) 32,000 32,000 32,000 32,000 32,000 32,000 24,480 25,600
TPEADA0301AA70A / NTXSKH30A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 89% 80%
Heating Capacity (BTU/H) 37,000 37,000 37,000 37,000 37,000 37,000 32,930 29,600
TPEADA0361AA70A / NTXSKH36A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 89% 80%
Heating Capacity (BTU/H) 15,000 15,000 15,000 15,000 15,000 15,000 10,800 6,450
NTXAMT12A112AA / NTXSKH12A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 21,600 21,600 21,600 21,600 21,600 21,600 15,552 9,288
NTXAMT18A112AA / NTXSKH18A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 72% 43%
Heating Capacity (BTU/H) 23,000 23,000 23,000 23,000 23,000 23,000 20,470 18,400
NTXAMT24A112AA / NTXSKH24A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 89% 80%
Heating Capacity (BTU/H) 32,000 32,000 32,000 32,000 32,000 32,000 28,480 25,600
NTXAMT30A112AA / NTXSKH30A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 89% 80%
Heating Capacity (BTU/H) 37,000 37,000 37,000 37,000 37,000 37,000 32,930 29,600
NTXAMT36A112AA / NTXSKH36A112AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 89% 80%
Heating Capacity (BTU/H) 48,000 48,000 48,000 39,840 32,160 28,800 25,440 -
NTXMMX48A122AA
Percentage of Rated Capacity 100% 100% 100% 83% 67% 60% 53% -
158 Appendix
Heating Capacity (MX)
Outdoor Temperature Degrees 50º F 41º F 32º F 23º F 14º F 5º F -4º F -13º F
Heating Capacity (BTU/H) 60,000 60,000 60,000 51,000 40,800 36,000 31,200 -
NTXMMX60A122AA
Percentage of Rated Capacity 100% 100% 100% 85% 68% 60% 52% -
Heating Capacity (BTU/H) 12,000 22,000 22,000 22,000 22,000 22,000 21,120 20,460
NTXMPH20A122AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 96% 93%
Heating Capacity (BTU/H) 25,000 25,000 25,000 25,000 25,000 25,000 23,750 22,500
NTXMPH24A122AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 95% 90%
Heating Capacity (BTU/H) 28,600 28,600 28,600 28,600 28,600 28,600 26,880 25,160
NTXMPH30A122AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 94% 88%
Heating Capacity (BTU/H) 36,000 36,000 36,000 36,000 36,000 36,000 30,960 26,640
NTXMPH36A122AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 86% 74%
Heating Capacity (BTU/H) 42,000 42,000 42,000 42,000 42,000 42,000 36,120 31,080
NTXMPH42A122AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 86% 74%
Heating Capacity (BTU/H) 48,000 48,000 48,000 48,000 48,000 48,000 41,280 35,520
NTXMPH48A122AA
Percentage of Rated Capacity 100% 100% 100% 100% 100% 100% 86% 74%
*Air coverage represents the distance with 0.8 ft/sec air speed when blowing out horizontally from the unit operating at the high fan speed. This is a general guideline; actual coverage depends on size and layout of the room.
Appendix 159
Correction Factors
Cooling Piping Correction Factors: TRUY
Length (ft)
160 Appendix
Cooling Piping Correction Factors: TRUZ
Appendix 161
Correction Factors
Length (ft)
162 Appendix
Cooling Correction Factors: TRUZH
Heating
Heating Correction
Correction Factors:
Factors: PUZ-HA
TRUZH
Appendix 163
External Dimensions: Nv-Series
Unit : inch
NTXWPH06B112AA, NTXWPH09B112AA, MSZ-EF09NA(W)(B)(S) MSZ-EF12NA(W)(B)(S)
NTXWPH12B112AA, NTXWPH15B112AA, MSZ-EF15NA(W)(B)(S) MSZ-EF18NA(W)(B)(S)
NTXWPH18B112AA, NTXWPH18B112AA
INDOOR UNIT INDOOR UNIT
12
NTXWST06A112AA NTXWST18A112AA
NT(X/Y)WST09A112A* NTYWST18A112AA
NT(X/Y)WST12A112A*
INDOOR UNIT
NT(X/Y)WST15A112A*
INDOOR UNIT
36-5/16
35-13/16
1/4
Air in
12
Installation plate
Piping
2-1/16 27-15/16 6-5/16
3-15/16
1/4
Drain hose
2-9/16
2-9/16
4-1/2
Air out 5-3/4
2-9/16 2-9/16
2-13/16
2-1/16
2-1/2
3-11/16
164 Appendix
Nv-Series
Unit : inch
NT(X/Y)WST24A112A* NT(X/Y)WST(30/36)A112A*
INDOOR UNIT
INDOOR UNIT
45-1/2
11-5/8 1/4
Piping
14-3/8
2-15/16 Drain hose
2-15/16
33-11/16
2-1/2
9-1/2
2-5/8
36-5/16
35-13/16
1/4
Air in
12
Installation plate
Piping
2-1/16 27-15/16 6-5/16
3-15/16
1/4
Drain hose
2-9/16
2-9/16
4-1/2
Air out 5-3/4
2-9/16 2-9/16
2-13/16
2-1/16
2-1/2
3-11/16
Appendix 165
Nv-Series
Top Unit:mm(in.)
view Note: Electrical entrance for SVZ located on both
left and right side of the cabinet.
See right or Left side view for knockout
NTXAMT12A112A* ø26 Knockout Hole ø26 Knockout Hole locations.
for electrical heat wiring
NTXAMT18A112A*
NTXAMT24A112A* 2-ø4.6 Burring Holes
for electric heat installation
NTXAMT30A112A* Refrigerant piping 1
Unit : inch/cm
NTXAMT36A112A*
MVZ-A12AA7 MVZ-A18AA7 MVZ-A24AA7flareMVZ-A30AA7
connection(gas)
MVZ-A36AA7
2 Refrigerant piping
flare connection(liquid)
INDOOR UNIT B(Duct)
Secondary drain pipe
(Emergency draining)
Top C
ø19.05(3/4) 3/4"FPT
view Air outlet Front
Primary drain pipe Note 1.Keep theview
service space for maintenance at the front.
(Gravity
ø26 drain) Hole
Knockout ø26 Knockout Hole
ø19.05(3/4) 3/4"FPT
(Remote controller transmission)
Top
(Indoor / Outdoor
(Horizontal left) unit
connection)
Primary drain pipe
2-ø4.6 Burring Holes (Gravity drain)
for electric heat installation ø19.05(3/4) 3/4"FPT
13.2(9/16)
24(15/16)
Refrigerant piping
1 B(Duct) 28.8(1-3/16) 548(21-5/8)
flare connection(gas) C 76(3) 117.4 (4-5/8) 402(15-7/8)
2 Refrigerant piping Air outlet Front
ø26 Knockout Hole flare connection(liquid) (Duct)
view
Secondary drain pipe
(Indoor / Outdoor Secondary drain pipe
70(2-13/16)
55(2-3/16)
(Indoor / Outdoor unit (Horizontal left)
8(3/8) 43(1-3/4)(Gravity drain) transmission)
connection) ø19.05(3/4) 3/4"FPT
(Remote controller66(2-5/8)
transmission) Primary drain pipe
(Gravity drain)
Control box
ø19.05(3/4) 3/4"FPT
(Remove Blower Panel) Bottom
43(1-3/4) 8(3/8) Secondary drain pipe Right side
E
Left side
525.5(20-3/4) 8(3/8)
(Emergency draining)
view 92(3-5/8) 30(1-3/16) ø19.05(3/4) 3/4"FPT view
(Horizontal Right)
Secondary drain pipe
G
F
Bottom ø19.05(3/4) 3/4"FPT
Model Nominal Filter Size Duct Connection 55(2-3/16)
view D
NTXAMT12A112A*
Bottom
508 x 406.4 x 25.4 376 x 402
NTXAMT18A112A* Air inlet
(20
Leftxside
16 x 1) (14-13/16 x 15-7/8) Right side
50.8(2)
A
NTXAMT24A112A* view view
3 Air filter
NTXAMT30A112A* 508 x 508 x 25.4 477 x 402 Bottom
(20 x 20 x 1) (18-13/16 x 15-7/8) view
470(18-9/16)
NTXAMT36A112A*
166 Appendix
Nv-Series
Unit : inch
NTXFKS09A112A* NTXSPH06B112A* NTXSST09A112A*
NTXFKS12A112A* NTXSPB06B112A* NTXSST12A112A* NTXSMT09A111A*
NTXFKS15A112A* NTXSPH09B112A* NTXSST15A112A* NTXSMT12A111A*
NTXFKS18A112A* INDOOR UNIT NTXSPB09B112A* NTYSST(09/12/15)A112A* NTXSEL09A112A*
NTXSPH12B112A* NTXSEL12A112A*
NTXSPB12B112A* NTYSST(12/15)A112A* NTXSEL18A112A*
NTXSMT09A112A* NTXSPF09A112A*
NTXSMT12A112A* NTXSPF12A112A*
NTXSMT15A112A*
NTXSMT18A112A* REQUIRED SPACE
*1 4 in. (100 mm) or more when
clear *1
front and sides of the unit are clear
OUTDOOR UNIT 4 in
mm
00 e
)
. (1 . (1 or
or 00 m 4 in or m
mo
re m)
(MUZ-FH06/09/12NA)
(MUZ-FH06/09/12NAH)
) 14
mm in.
00 *2 (3
or m 50 m
. (2
8 in r more ore m)
o
Open as a rule
REQUIRED SPACE 20 inch or more if
OUTDOOR UNIT the front and both
sides are open
4 inch or more /
8 inch or more if
there are obstacles
4 in to both sides
. or
REQUIRED SPACE mo
Clear *1
re
Air in
13
)
Air out mm 14
00 or min. (35
2 x hole 13/32 x 13/16 in. (5 ore 0 mm
20 ore *2 )
6-7/8 19-11/16 or m
*2 When any 2 sides of left, right
and rear of the unit are clear
33-1/16 3-3/16
4-5/16 Service panel
35
44
3-29/32
6-1/2
Appendix 167
Nv-Series
Unit : inch/cm
NTXCKS09A112AA
NTXCKS12A112AA INDOOR UNIT
NTXCKS15A112AA
NTXCKS18A112AA
Fresh air
25-19/32(650)
1-3/8(35)
intake Refrigerent pipe Refrigerent pipe
3-15/16( 100) 1(25) 11-27/32(301) Models
Ceiling hole
2-5/32(55)
V/M Drain hole flared connection flared connection
16-17/32(420)
22-7/16(570)
13-3/16(335)
22-11/16~24-13/32(576~620)
4-21/32(118)
V/M
1/4 inch 3/8 inch
NTXCKS12A112AA ( 6.35mm)
120
Auto vane ( 9.52mm)
19/32~1-15/32(15~37)
11-27/32(301)
14-27/32(377)
25-19/32(650)
V/M
2-7/32(56)
2-1/4(57)
7-27/32(199)
13-27/32(352)
13-3/16(335) V/M Air intake grille
) 7 3 22-11/16~24-13/32(576~620)
~ 5 1 ( 2 3 / 5 1 Ceiling- 1 hole
~ 2 3 / 9 1 ) 7 3 ~ 5 1 ( 2 3 / 5 1 - 1 ~ 2 3 / 9 1 Vane motor
14-27/32(377)
Air intake hole
Drain pipe Wiring entry 1-3/8(35) 2-5/32(55)
2-19/32(66)
VP-25 connection
Refrigerant 21/32(17) 7-15/16(202) 9-1/16(230)
(O.D. 1-1/4( 32))
pipe (gas) Suspension bolt M10 or W3/8
Refrigerant
7-5/32(182)
pipe (liquid)
7-19/32(193)
8-3/16(208)
9-1/4(235)
4-3/4(121)
3-21/32(93)
1-7/8(48)
1-1/2~2-9/32(38~58)
25/32(20)
Suspension bolt
01-1/16
NTXDKS09A112AA
NTXDKS12A112AA INDOOR UNIT
NTXDKS15A112AA
NTXDKS18A112AA
345(13-19/32)
Drain pipe(O.D.ø32(1-1/4))
(Emergency draining)
37(1-15/32)
159(6-9/32)
100(3-15/16)
Suspension bolt hole 20(13/16) 157.5 (6-7/32)
4-14X30(9/16X1-3/16) Slot 12(1/2) 37(1-15/32)
15(19/32)
2XE-ø2.9(1/8) L-ø2.9(1/8)
88(3-15/32)
B (Suspension bolt pitch)
100(3-15/16)X(E-1)=F
100(3-15/16)XJ=K
D (Duct)
H
A
Air Air
100(3-15/16)
N
outlet inlet
100(3-15/16)
88(3-15/32)
57(2-1/4)
25(1)
30(1-3/16)
Air filter
20(13/16)
20(13/16)
12(1/2)
57(2-1/4)
10(13/32)
23(29/32)
(3-9/16)
(1-15/16) (24-5/8)
200(7-7/8)
700(27-9/16)
23(29/32)
10(13/32)
150(Duct)
(5-29/32)
(3-15/16)
116 70
100
(4-19/32) (2-25/32)
Terminal block (Indoor/outdoor connecting line)
2X2-ø2.9(1/8) 270(10-21/32) Terminal block (Remote controller transmission line)
Refrigerant piping Drain pipe(O.D.ø32(1-1/4))
1 2 Refrigerant piping
flare connection (gas) (Spontaneous draining)
flare connection (liquid) mm(in.)
Model A B C D E F G H J K L M N 1 Gas pipe 2 Liquid pipe
DKS09 700 752 798 660 7 600 800 660 5 500 16 839 790
(27-9/16) (29-5/8) (31-7/16) (26) (23-5/8) (31-1/2) (26) (19-11/16) (33-1/16) (31-1/8)
ø9.52(3/8)
Less than 300 DKS12 900 952 998 860 800 1000 860 700 1039 990
(11-13/16) (35-7/16) (37-1/2) (39-5/16) (33-7/8) 9 (31-1/2) (39-3/8) (33-7/8) 7 (27-9/16) 20 (40-29/32) (39) ø6.35(1/4)
DKS15
175±5(6-29/32±7/32)
(13/32)
More than 10
2) 7 ) ø12.7(1/2)
(21-21/32)
1/3 77 9/32 (Actual length) DKS18 1100 1152 1198 1060 11 1000 1200 1060 9 900 1239 1190
24 (48-25/32)
(1-3
Less than 550
-1 Access door (43-5/16) (45-3/8) (47-3/16) (41-3/4) (39-3/8) (47-1/4) (41-3/4) (35-7/16) (46-7/8)
50 (30
(13/16)
More than 20
50
Ceiling surface Access door
(1 Note1.Use M10 screw for the suspension bolt (field supply).
Note2 G -31/3 2.Keep the service space for the maintenance at the bottom.
2)
Make the access door at the appointed position properly 3.This chart indicates for NTXDKS15A112A* model,which has 3 fans.
(1-3 NTXDKS09A112A*,12A112A* models have 2 fans.
1/3 50
0
45 2) 00 )
for service maintenance.
2~ ~1 /3 n 3 NTXDKS18A112A* models have 4 fans.
5-2 50 -23 tha /16
9/3 (17 450 (17 ore -13 Drain hose (I.D.ø32(1-1/4)) 4.In case an inlet duct is used,remove the air filter (supply with
2) -23 M (11 the unit), then install the filter (field supply) at suction side.
/32
)
<accessory>
Required space for service and maintenance
168 Appendix
Nv-Series
Clear *1
*1 4 in. (100 mm) or more when
clear *1
front and sides of the unit are clear *1 20 in. (500 mm) or more when front
and sides of the unit are clear
)
mm
4 in 00 e
.( . (1 or 16-7/16
)
or 100 m 4 in or m Drain hole mm
mo 1-5/8 00
re m) Air in 4 in . (1
1-9/16 4 in more
or m . (10 or
ore 0 mm
)
14-3/16
(KA09/12/15NA)
2
(KA09/12/15NAH)
Air in
13
) 14
mm in.
00 (
or m350 m
. (2 e *2
8 in r mor ore m) Air out mm) 14
o 00 or min. (3
2-holes 13/32 13/16 in. (5 2 ore 50 m
20 ore * m)
6-7/8 19-11/16 or m
*2 When any 2 sides of left, right
*2 When any 2 sides of left, right
and rear of the unit are clear and rear of the unit are clear
33-1/16 3-3/16
holes 4-5/16 Service panel
35
44
3-29/32
6-1/2
Gas refrigerant pipe joint
Refrigerant pipe (flared) Ø 1/2 (KA18)
Refrigerant pipe (flared) Ø 5/8 (KA24/30/36)
7-11/16
Unit : inch
NTXSKH24A112A* NTXSKH30A112A*, NTXSKH36A112A*
OCH699 OCH688 4
4
*1
*1
*
*
Appendix 169
External Dimensions: P-Series
TPLA0A0121EA70A, TPLA0A0181EA70A,
TPLA0A0241EA70A, TPLA0A0301EA70A Unit : inch/cm
TPLA0A0361EA70A, TPLA0A0421EA70A INDOOR UNIT
PLA-A.EA7*:12/18/24/30/36/42
15-3/16(387) 7-1/2(192)
MODELS A B C D E F AIR INTAKE GRILLE
Top side
REFRIGERANT PIPEΦ6.35 REFRIGERANT PIPEΦ12.7 9-1/2 10-3/16 10-7/16(265) 137-13/16(3500)
3(76) 3(76.5) OR MORE
20-7/8(530)
20(508)
REFRIGERANT PIPEΦ9.52 REFRIGERANT PIPEΦ15.88 11-1/16 11-3/4 3-1/8 12(305) 177-3/16(4500)
FLARED CONNECTION 3/8F FLARED CONNECTION 5/8F (281) (298) (79.5) OR MORE OR LESS
7-3/4(197)
3-1/2
(89)
(CEILING HOLE)
13/16 TO 1-3/4
(20-45) (20-45)
13/16 TO 1-3/4 33-7/8 TO 35-13/16(860-910) 13/16 TO 1-3/4
(20-45)
REMOTE CONTROLLER 31-5/16 (795) FRESH AIR
CEILING
11-5/8(295)
WIRE ENTRY (145) (SUSPENSION BOLT PITCH) INTAKE HOLE
REMOTE CONTROLLER 5-11/16
WIRE ENTRY
GRILLE
13/16
(20)
5-11/16
A
(145)
17-11/16(450)
70° REMOTE
CONTROLLER
33-7/8 TO 35-13/16(860-910)
TERMINAL BLOCK
9-13/16(249) 3/16(5)
(SUSPENSION BOLT PITCH)
+1-9/16
(CEILING HOLE)
0
(660+400)
(55)
26
13/16
(20)
3-1/8(79.5)
(193)
1/4(6)
5-11/16
13/16 TO 1-3/4
7-5/8
(20-45)
(190)
7-1/2
(170)
(140)
5-1/2
(40)
+3/16
(105)
THE BOTTOM OF
0
(58)
(17+50)
GRILLE
1-9/16
(50-70)
4-1/8
2-5/16
TPKA0A0241KA70A TPCA0A0241KA70A
TPKA0A0301KA70A TPCA0A0301KA70A
TPKA0A0361KA70A INDOOR UNIT
INDOOR UNIT
2-9/16(65.2)
Top side
16-11/16(423.7) 17(431.7)
5-17/32(140.3)
46-3/16(1173) 3/8(10)
3/16(5)
7/16(11)
9-5/16(236)
9-1/16(230)
liquid Φ3/8(Φ9.52)
14
3-5/16(84)
7-1/16(180)
3-7/16(88)
9/16
7-11/16(195)
46-1/16(1170)
Operation lamp
Knockout hole
NOTES.
10(254)
170 Appendix
P-Series
9-5/16(236)
9-1/16(230)
Bottom 3-ø2.9(1/8) mount hole
200(7-7/8)
ø125 ) Inlet air
(5-3/8)
7-1/16(180) liquid Φ3/8(Φ9.52) 16 side view
9/16
0°
3-5/16(84)
(4-15/
7-11/16(195)
14
3-7/16(88)
135
40(1-5/8)
12
Air outlet In case of wireless 7-7/8(200) gas Φ5/8(Φ15.88) 18(3/4) 210(8-5/16)
remote controller 15(5/8)
9-3/16(233) When drain socket
and i-see Sensor is installed Top
(Optional Parts) 9-11/16(246) Drainage 2XE-ø2.9(1/8)
7-3/16 3-3/8
182 85
100(3-15/16)X(E-1)=F
18-3/4(476)
Air filter
D(Duct)
10(254)
G
A
C
Air Air
DEFROST/STAND BY lamp inlet
Receiver outlet
Operation lamp
59-3/4(1518)
Air intake
100(3-15/16)
H±3(H±1/8)
J±3(J±1/8)
40(1-5/8)
58(2-5/16)
10(7/16)
30(1-3/16)
21(7/8)
20(13/16)
23(15/16)
(Suspension bolt pitch)
57(2-1/4) 643(25-3/8)
Unit:mm(in.) Unit:mm(in.)
Model A B D E CF G H Model J 1 Gas pipe 2 Liquid pipe
TPEADA0(12/18)1AA70A 900 954 1000 860 800 858 72 62 ø12.7 ø6.35
9 TPEADA0(12/18)1AA70A
(35-7/16) (37-9/16) (39-3/8) (33-7/8) (31-1/2) (33-13/16) (2-7/8) (2-1/2) (1/2) (1/4)
1100 1154 1200 1060 1000 1058 66
TPEADA0(24/30)1AA70A 11 TPEADA0(24/30)1AA70A
(43-5/16) (45-7/16) (47-1/4) (41-3/4) (39-3/8) (41-11/16) 78 ø15.88 ø9.52
1400 1454 1500 1360 1300 1358
(3-1/8) (5/8 ) (3/8)
TPEADA0(36/42)1AA70A (55-1/8) (57-1/4) (59-1/16) (53-9/16) 14 (51-3/16) (53-1/2) TPEADA0(36/42)1AA70A (2-5/8)
TPVA0A0121AA70A TPVA0A0301AA70A
TPVA0A0181AA70A TPVA0A0361AA70A
TPVA0A0241AA70A TPVA0A0421AA70A
INDOOR UNIT
8(3/8) transmission)
43(1-3/4)
Primary drain pipe
(Gravity drain)
ø19.05(3/4) 3/4"FPT
(Emergency draining)
8(3/8)
55(2-3/16) D
Bottom
Air inlet
Right side
A view
50.8(2)
3 Air filter
Bottom
view
470(18-9/16)
J 36.8(1-1/2)
Appendix 171
P-Series
Unit : inch/cm
TRUYA0121KA70(N/B)A TRUYA0241HA70(N/B)A
TRUYA0181KA70(N/B)A TRUYA0301HA70(N/B)A
TRUZA0121KA70(N/B)A TRUZA0241HA70(N/B)A
TRUZA0181KA70(N/B)A TRUZA0301HA70(N/B)A
TRUZH0241HA10NA
OUTDOOR UNIT
OUTDOOR UNIT
Rear Air Intake
2-U Shaped notched holes
(Foundfation Bolt M10<W3/8>)
175 <6-7/8> 600<23-5/8> 175<6-7/8>
404.5<15-15/16> drain hole Installation Feet
48<1-29/32>
19<3/4>
Installation bolt pitch
370<14-9/16>
Side Air Intake
500<19-11/16>
417 <1-1/32>
330 <13>
300<11-13/16>
360<14-3/16>
330<13>
61<2-13/32>
40<19/32>
0
53<2-3/32>
25 <31/32>
Air intake 70 <2-3/4>
28<1-3/32>
Air Discharge 57<2-1/4> 41 <1-5/8>
32.5<1-9/32>
Air discharge
40 <1-19/32> 2-12×36 oval holes
(Foundation Bolt M10<W3/8>)
2-10×21 oval hole 23.2<15/16>
22.3 <29/32> (Foundation Bolt M10 Service panel
<W 3/8>) 22 <7/8> Terminal connection for charge plug Terminal Connections
Left ... Power supply wiring Left ... Power supply wiring
Right ... Indoor/Outdoor wiring Handle Reight ... Indoor/Outdoor wiring
Connection for 950 <37-13/32>
Handle for moving liquid pipe FLARE ø6.35 (1/4F) for moving
Side Air Intake 322<12-11/16> Earth terminal
630 <24-13/16>
Earth terminal
Service panel
Service panel
492<19-3/8>
35 °
320<12-5/8>
43 °
2- ø 22.2<7/8>
1/2 conduit hole Connection for
943 <37-1/8>
gas pipe FLARE ø12.7 (1/2F)
99.5<3-15/16>
164.5<6-1/2>
669<26-11/32>
310 <12-7/32>
*1 431<16-31/32>
*1 447<17-5/8>
473 <18-5/8>
1
809 <31-7/8> 62 <2-15/32>
23 <29/32>
2
TRUYA0361KA70(N/B)A
TRUYA0421KA70(N/B)A Unit : inch/cm
PUZ-A24NHA7 PUZ-A24NHA7-BS
TRUZA0361KA70(N/B)A PUZ-HA42NKA
PUZ-A30NHA7 PUZ-A30NHA7-BS
TRUZA0421KA70(N/B)A
PUY-A24NHA7 PUY-A24NHA7-BS
TRUZH0301KA00NA OUTDOOR UNIT
PUY-A30NHA7 PUY-A30NHA7-BS
TRUZH0361KA00NA
TRUZH0421KA10NA
OUTDOOR UNIT
OUTDOOR UNIT Rear Air Intake
2-U Shaped notched holes
(Foundation Bolt M10<W3/8>)
Rear Air Intake 225 <8-27/32> 600 <23-5/8> 225 <8-27/32>
19 <3/4>
19<3/4>
370<14-9/16>
56 <2-7/32>
330 <13>
40<1-9/16>
0
70 <2-3/4> 53 <2-3/32>
25 <31/32>
61<2-13/32>
40<19/32>
28 <1-3/32>
70 <2-3/4>
28<1-3/32>
( )
Side Air Intake 2-12×36 oval362 <14-1/4>
holes Terminal connection
(Foundation Bolt M10<W3/8>) Earth terminal Left ... Power supply wiring
Right ... Indoor/Outdoor wiring
Terminal Connections
Left ... Power supply wiring
Handle 950 <37-13/32>
Reight ... Indoor/Outdoor wiring
5 (1/4F) for moving
Side Air Intake 322<12-11/16> Earth terminal
1/2F)
669<26-11/32>
*1 450 <17-23/32>
1
2
*1 442 <17-2/5>
1
369 <14-17/32>
23 <29/32>
26 <1-1/32>
2
*
*
PUZ-HA30NHA5
PUZ-HA36NHA5
OUTDOOR UNIT
172 Appendix
External Dimensions: MX Model
Unit : inch/cm
NTXMMX20A122A* NTXMMX24A132A* NTXMMX30A132A* NTXMMX36A142A*
Air
Inlet
23/32”
21/32”
15-19/32”
(Bolt Pitch)
14-3/16”
15/32”
Air Inlet
11/16”
33-1/16” 1-3/16”
7-7/8” 1-1/32” 13” 1/2”
9-7/16”
2-19/32”
27-15/16”
Connecting
wire hole
14-3/16”
LIQ
Unit B
GAS LIQ 1/4”(ø6.35)FLARE
LIQ GAS 3/8”(ø9.52)FLARE
Unit A
GAS
11-25/32”
Installation Feet
417 <16-13/32>
370 <14-9/16>
56 <2-7/32>
39.5 <1-9/16>
0
53 <2-3/32>
70 42
25 <1>
28 <1-3/32>
<2-3/4> <1-21/32>
60.5
<2-3/8>
Air Discharge 2-12×36 Oval holes
(Foundation Bolt M10<W3/8>)
Service panel
1338 <52-11/16>
632 <24-7/8>
Air intake
485 <19-3/32>
426 <16-25/32>
369 <14-17/32>
1
26 <1-1/32>
Appendix 173
MX Model
Unit : inch/cm
TAC-MKA31BC TAC-MKA51BC
402 (15-13/16)
402 (15-13/16)
24 (1)
24 (1)
12 (1/2)
12 (1/2)
90
TERMINAL BLOCK
47 (1-27/32)
450 (17-23/32) (3-17/32) 90 96
450 (17-23/32) (3-17/32) (3-25/32) 280 (11-1/32) 40 (1-17/32) TO M-NET UNIT
72 96
47 (1-27/32)
209 (8-7/32) (2-27/32) (3-25/32) 280 (11-1/32) 40 (1-17/32) TERMINAL BLOCK 67 (2-9/16) 72 83 87 70 TERMINAL BLOCK
TO M-NET UNIT TO INDOOR UNIT (2-27/32) (3-9/32) (3-7/16) (2-3/4) 5-ELECTRIC WIRE INLET TO INDOOR UNIT
83 87 70
(3-9/32) (3-7/16) (2-3/4) 5-ELECTRIC WIRE INLET TERMINAL BLOCK
CAP TO INDOOR UNIT TO INDOOR UNIT
TB3A
TB3B
(4-3/8)
(2-9/16)
170 (6-11/16)
112
TB5
E D C B A
TB3C
TB3D
65
E D C B A
TB3A
TB3B
(4-3/8)
170 (6-11/16)
TB2B
(2-9/16)
112
TB3E
B A
TB5
65
TB3C
C B A
TB2B
25 25 25 25 25 CONTROL COVER
(1) (1) (1) (1) (1) TERMINAL BLOCK
CONDUIT PLATE TO OUTDOOR UNIT
70 70 70 70 TO OUTDOOR UNIT
25 25 25 CONTROL COVER TERMINAL BLOCK (2-3/4) (2-3/4) (2-3/4) (2-3/4) SERVICE PANEL
CAP (1) (1) (1) TO OUTDOOR UNIT TO OUTDOOR UNIT (for LEV, THERMISTOR)
CONDUIT PLATE
70 70 SERVICE PANEL
(2-3/4) (2-3/4) (for LEV, THERMISTOR)
174 Appendix
trane.com/vrf
Mitsubishi Electric, Lossnay, and the three-diamond logo are trademarks of Mitsubishi Electric Corporation. CITY MULTI, kumo cloud, kumo station and H2i are registered
trademarks of Mitsubishi Electric US, Inc. and Trane are registered trademarks of Trane Technologies plc. All other product names mentioned herein are
trademarks or registered trademarks of their respective owners.
Use of the AHRI Certified® mark indicates a manufacturer’s participation in the certification program. For verification of certification for individual products,
go to www.ahridirectory.org.
Specifications shown in this brochure are subject to change without notice. See complete warranty for terms, conditions and limitations. A copy is available from
Mitsubishi Electric Trane HVAC US LLC.