You are on page 1of 21

Upgrade your HVAC equipment to use EC Fans

Daniel Yiu, Regional Sales Manager


ebm-papst Hong Kong Ltd MP: (852) 9321 0453
About Hong Kong, Macau

• 75.8% of commercial buildings and 90% of • 24 hours operation in Macau Casino


composite buildings were built before 1995
Index

• Problem

• Solution

• Product portfolio

• Benefits

• Installation examples / case studies

• Drop-in kits for HVAC

• Local expertise

3
Old HVAC fans
Problem – High cost: Belt-Driven

- Ongoing maintenance cost for belts, pulleys, bearings


- Failures and inefficiencies
- How well is the current system performing?
- High losses and power consumption
- Belt dust – associated cost
- Noise - fan and pulleys
- Expensive and time consuming to fix

4
Old HVAC fans
Problem – High cost: Blower

- Corrosive - sheet steel impeller


- Dust – associated cost
- Loss 100% any components failure
- Cannot replace fan blower if any failure due
to limited AHU plant Room and access door
- Expensive and time consuming to fix

5
Solution provider

EC Upgrades provides a solution to optimise the whole system!

• Initial analysis and proposal


Site surveys • Feasibility studies

• Business case
Proposal • Fan Selection

• Qualified and local contractor


Installation • Or end customer contractor

• Metering
Measurement
and Verification • Reporting
Marketing Mix
Placement Sales channel

Engineering
Contractors
(quotation & technical
issues)

End user(s) /
Operators (direct
promotion, saving
estimation & put tender
specs
EC Upgrades – Benefits

- No service or maintenance required


- Build in electronics and speed control
(analogue 0-10V, 4-20mA, PID etc)
- High level interface (RS485 MODBUS)
- High efficiency direct drive system
- Modular and redundant systems for larger
installations
- High reliability and minimal down time in
Our products are designed to
cause the least possible disruption cases of fan failures
to your HVAC system during
change over

8
Maximising EC benefits
Speed control

Speed control (reduction) provides massive savings

Just 5% reduction in air flow


Air Volume Power provides 14% reduction in fan power
100% 100%
95% 86% 50% reduction in air flow equates to 87%
reduction in fan power
90% 73%
75% 42%
50% 13% Reduction of outside air into the building
25% 1,6% reduces load on air conditioning system

9
Maximizing EC benefits
High level interface – integration into BMS

LAN/Ethernet
BACNET
MODBUS RTU ….

10
Maximizing EC benefits
High level interface – integration into BMS

MODBUS RTU

11
Retrofitting fans - why should I do that?
Lower energy bills and almost zero maintenance
Retrofitting fans - why should I do that?
Retrofitting fans – How to start it?
Template for measuring AHU
Case Study 2: Ap Lei Chau Building
(FanBox)

Power Consumption Saved Initial Measurement 35%- 50%

Retrofit Works Time 1.5 Days

15
Case Study 1: Grade A Commercial building (Hong Kong Island)
Belt-Driven VSD Fan to EC plug fans for VAV AHU System
Air-conditioning system of variable air volume (VAV)

AC Belt Driven with external VFD

Performance analyses Tools:


• Portable power analyser
• Sound pressure level meter
were utilised

16
Measuring volume air-flow with nozzles

This formula is used to


calculate volume air-flow:

Static pressure ∆pw is measured at these two points –


pressure tap inside nozzle vs. static pressure before
nozzle

17
Report from Hong Kong Green Building Council

http://www.bsomes.org.hk/upload_pdf/GPRD2016_S4-2.pdf

18
• The VFD losses are 10% to 30% at 25% • EC Motor can maintain a relatively high
torque and speed efficiency from the rotation speed of 10% to
19
• efficiency of a belt drive can easily slip to 60% 100%.
to 70% if the gear adjustment is incorrect
The fan as a system
Measured Overall Centrifugal Fan system efficiency in an AHU comparison

EC Motor Direct-driven eff 91% x Fan eff 75% = overall eff 68%
% 70 AC Motor Belt-driven eff 77.5% x Fan eff 73% = overall eff 56%

65

60 

55
Belt-Driven
(current system performing)
System efficiency e

50
 PM Plug Fan with Motor Same Air Output but
(IE4)
Lower system efficiency
 AC Plug Fan with Motor
= greater power input
45 (IE3)
RLM – Ø 400  EC Plug Fan = extra heat need to be
 AC Plug Fan with Motor (IE2)
(airfoil blade) removed
40 > Select Highest efficiency
0 10 20 30 40 50 60 70 80 90 100 110
EC Fan. THE BEST!
 Partial load rate (3 kW / Ped) %
Thank you for your attention!

You might also like