DAIKIN WMT Dynamic Chiller
DAIKIN WMT Dynamic Chiller
sustainable
technology
legacy
about
Series
from a
expect
CHILLER?
What do you
about
Reduced Maintenance
Low Investment
performance
sustainable
technology
Environmental
legacy
about
Friendly
Reliability
technology
legacy
about
Magnetic Bearing Chiller
might be the solution
performance
sustainable
technology
legacy
about
A Magnetic Bearing is a bearing that supports a load
using Magnetic Levitation,
which supports moving parts without Physical Contact.
technology
legacy
DAIKIN Frictionless Magnetic Compressor
performance
sustainable
technology
legacy
performance
sustainable
technology
legacy
about
MESSAGE FROM
Series
WMT CHILLER, DAIKIN
WMT from Daikin Applied is the chiller that defines a new chiller
generation, it is equipped with the latest technology, runs on the most
environmental refrigerant (R1233zd).
LOW HIGH
TOXICITY TOXICITY
Toxicity – ASHRAE 34
• A (lower toxicity) or
HIGH A3 B3 • B (higher toxicity)
Increasing Flammability
performance
sustainable
FLAMMABILITY
technology
Flammability - ASHRAE 34
about
• 1 (no flame propagation)
A2 B2 • 2L (lower flammability)
LOW effect of ignition is not so large
R32
FLAMMABILITY R452B & typically difficult to ignite
HFO1234yf
A2L R454B B2L • 2 (lower flammability)
R447A
HFO1234ze ARM-71a
• 3 (higher flammability)
HFO1233zd R123
NO FLAME A1 B1 R514A
R134a R513A
PROPAGATION R410A R513B
R22 R450A
Increasing Toxicity
2003 2009 2020
1 2 3
performance
sustainable
technology
legacy
Own Leading the
about
Early Adopter
Technology Pack
1st Mag Bearing Perfecting the craft More than 10,000
chiller produced of mag chiller to units of mag chiller
and installed in become the 1st installed worldwide.
China since 2003, chiller manufacturer We now offer next-
still going strong! with own mag gen mag chiller
compressor with HFO
performance
sustainable
technology
legacy
about
We bring a new definition to chiller technology
by
• High efficiency
multi-stage
• Fuji VFD
design
• Air-cooled starter to
• Truly lubrication
have better reliability
free Magnetic
at low lift condition
bearing
• Double • Enhanced Patented
independent IGV Cyclone Economizer
performance
sustainable
technology
• Fewer Ref. charge
legacy
• High separation eff.
about
• Liquid carry over
• PCO5+ preventing
controller
• Advanced
OITS
• Updated liquid
level control • Lower pressure drop design
• More reliable • Patented falling fil evaporator
butterfly valve • New sub cooler for condenser
driven by actuator
All-in-one, only
performance
sustainable
technology
legacy
about
Lubrication
Dynamic Low Drag Robust
Free
Multi-stage Impeller Magnetic Bearing Permanent Magnet Dynamic IGV +
Motor Dynamic Speed Drive
Dynamically Not only oil-free but Eliminates rotor Adaptable to
balanced back-to- truly LUBRICATION- excitation loss to various operating
back impellers FREE, unlike others deliver superior condition that keeps
running on HFO that eliminates the motor efficiency the compressor
refrigerant provides oil but still need under high speed running smoothly to
best efficiency other form of operation optimize the energy
reduces size & noise lubrication used
Duo-Impeller by
Dynamically-
Balance Impellers
Sample 2 back-to-back impellers
performance
working seamlessly
sustainable
technology
together and
legacy
complementing each
about
other like 2 opera singer
in a duo
Sample
TECHNOLOGY.
3D Impeller Design by
With latest CFD analysis, the new 3D impeller is
projected to achieve 2% more efficiency over other
HFO chillers’ peak efficiency
performance
sustainable
technology
legacy
about
Double-IGV by
Individually
1st
Modulated IGV
IGV Each impeller is equipped
performance
technology
(IGV) and optimally
legacy
controlled to give the
about
most accurate cooling
and efficiency
2nd
IGV
TECHNOLOGY.
Dynamic Load Control by
Dynamically
Controlled Loading
Combining proven VFD
Dynamic Speed technology used in Daikin’s Dynamic Refrigerant
Controlled by VSD chillers with Dual-IGV control Controlled by 2 IGV
Controlled RPM and Optimized IGV positions enable part
performance
sustainable
technology
legacy
more than 8% load efficiency* and reduce surging
about
10.0%
Improved - IGV (varying
position) Optimized
8.0%
Performance inprovement form
IGV A° position
6.0%
IGV B° position
4.0%
baseline
IGV C° position
2.0%
-4.0%
Baseline - IGV (fixed
position) Non-optimized
-6.0%
% Capacity Loading
*Compare to baseline of fix position IGV
TECHNOLOGY. Optimization of IGV position is obtained
from Daikin’s extensive in-house testing
Superior Evaporator, only
01 02 03
Refrigerant spray
performance
sustainable
technology
legacy
about
Evaporator Liquid Distribution Refrigerant Charge
Great Approach Prevent liquid carry over 30% refrigerant reduction
Approach T can decrease Special designed Multi- For 500RT, evaporator
from 1.3℃ to 0.8℃ by using stage distribution to reduce refrigerant charge decrease
FF, help to get 2% efficiency the highest vapor flow from 483kg to 283kg, save
improvement at full load velocity 42% refrigerant cost.
(500RT WMT) Use mesh filter and 18% cost reduction for
equalization plate to evaporator
prevent liquid carry over
Note: 5 times volute flow
rate than R134a
Horizontal Flash Economizer, only
01 02
CD
TD
CO
FV
performance
sustainable
technology
EV
legacy
With eco. Cooling capacity Power
about
No eco. Cooling capacity Power
10%↑
technology
standard. the non-condensable gases.
legacy
about
Refrigerant Flow Control Web Design
Reliable butterfly valve is equipped Here you need to add some brief
as standard that moves by about the service that your company is
continuously monitoring the liquid ref. providing currently
level.
technology
legacy
about
We bring a new definition to chiller plantroom performance
Highest efficiency across the board, only
Superior operating 400RT High lift operating condition
efficiency using: with condenser relief
• Multi-stage Centrifugal
compressor
• Truly Lubrication-Free
performance
sustainable
technology
Magnetic Bearing
legacy
about
Technology
• Dynamic Inlet Guide Vane
(DIGV)
• Dynamic Speed Drive (DSD)
Operating Condition:
• CHW in/out: 5/12Deg C
• CDW in/out: 29.5/35°C
performance
sustainable
technology
Magnetic Bearing
legacy
about
Technology
• Dynamic Inlet Guide Vane
(DIGV)
• Dynamic Speed Drive (DSD)
Operating Condition:
• CHW in/out: 8/13.5Deg C
• CDW in/out: 29.5/34.6°C
Daikin WMT chiller saves an average 4% efficiency (up to 6%) @ low lift
condition versus competitors’ Single-stage magnetic bearing centrifugal
chiller with R1233zd refrigerant
performance
sustainable
technology
legacy
about
We bring a new definition to sustainability
Truly Lubrication Free Duo-Impeller, only
Not lubrication free!
Truly lubrication free! No
need for lubrication circuit Complex
lubrication
circuit!
performance
sustainable
technology
legacy
about
Not lubrication free!
Complex
lubrication
circuit!
Reduced service maintenance cost, only
All centrifugal chillers
require some amount of
scheduled maintenance
• Cleaning tubes
performance
sustainable
technology
• Checking refrigerant levels
legacy
• The lubrication-free Daikin
about
WMT chiller sets itself apart
with lifetime savings on
driveline maintenance
NO Motor bearing
teardowns
NO Filter changes Sample
NO Lubrication system
maintenance
Compact Footprint, from
Competitor 1
performance
sustainable
technology
legacy
about
Competitor 1
Lowest carbon footprint, only
• Multi stage Mag • Proven Fuji Air-
Bearing with 2 Cooled Dynamic
IGV Speed Drive
• Daikin
Patented
performance
sustainable
technology
Cyclone
Economizer
legacy
about
• Daikin X Carel
PCO5+
Controller
• Daikin • Daikin
Dynamic Patented
Refrigerant
Falling Film
Control
Evaporator
Technical Features-Smart Control Center
User-friendly Operation Easy Troubleshooting BAS
Call us at anytime...
….We ensure our
customer comfort and
peace of mind ☺