SDS A2400-00

CONDENSATE
RECOVERY PUMP
MODEL CP-N
LOW NPSHr PUMP WITH HIGH DISCHARGE HEAD AND HIGH INLET TEMPERATURE CAPABILITY

Benefits
Ejector type pumps deliver reliable and economical
high temperature condensate recovery.
1. Ability to return condensate generated in steam
equipment directly to the boiler lowers radiant losses
and provides maximum energy gain.
2. Eliminates need for a separate condensate recovery
tank, thus lowers installation costs.
3. Low NPSHr pumps do not require high fill head,
thereby enabling usage in virtually all applications
near grade level.
4. High temperature condensate return up to 355 °F
minimizes the operating costs normally associated
with heating and deaeration of colder boiler feed
water.
5. Pumps high temperature condensate at high
discharge pressures without cavitation thus solving
many severe service application requirements.
6. High discharge capacities avert the need for multiple
pumps.
7. Pump provides continuous operation without DO NOT DISASSEMBLE OR REMOVE THIS
CAUTION PRODUCT WHILE IT IS UNDER PRESSURE.
cavitation in low NPSHa installations. Allow internal pressure of this product to equal
atmospheric pressure and its surface to cool to room temperature
before disassembling or removing. Failure to do so could cause burns
or other injury. READ INSTRUCTION MANUAL CAREFULLY.

Specifications
Model CP-N
Maximum Operating Temperature (°F) 356
Motor Power Source (V) 240/480 3 phase
Frequency (Hz) 60
Programmable Controller Power Source (V) 100/200
Shaft Seal Mechanical
Pump Discharge Head (ft) 165– 655
Pump Discharge Capacity (ft3/h) 105–530
Note: For NEMA/UL standards, contact TLV
To avoid abnormal operation, accidents or serious injury, DO NOT
CAUTION use this product outside of the specification range. Local regulations
may restrict the use of this product to below the conditions quoted.

No. Description Material* ASTM/AISI** JIS ⑥


① Pump Unit Steel/Cast lron — — ⑤
② Motor — — —

③ Ejector Carbon Steel A53 Gr.A STPG37
③ ④
④ Pressure Control Valve Cast Steel A216 Gr.WCB —
⑤ Pressure Switch — — —
⑥ Water Level Detector Carbon Steel AISI1025 S25C
⑦ Air Release Valve Stainless Steel A351 Gr.CF8 SCS13
* Material may change according type of CPN ** Equivalent


Dimensions
¡CP-N1105-6CHT 25 15/16
12 3/ 4
Units: inch
(Example)*
NPT 1/ 2
approx. 11

1 1/ 2”ASME 150
1” ASME 300
approx. 51
1
/ 16
12

Cooling water Cooling water


25 7/16 inlet outlet
NPT 3/ 4 NPT 3/ 4
4-ø 9/16 Bolt hole

1 9/16
13
3 15/16 3 15/16
29 1/ 2 14 3/16
37 7/16
49 5/ 8
1 15/16
/16
9

7 7/ 8
13

5 15/16
/16

3 15/16 3 15/16
9

29 1/ 2

* Pump Head 360 ft, Pumping Capacity 175 ft3/h. For dimensions of other CP-N types, contact TLV.
Both vertical and horizontal types are available.

Pump Motor Capacity


AC 60 Hz
Pump Head(ft)
165 200 230 260 295 330 360 395 430 460 495 525 560 590 625 655
105
3.7 kW
140
Condensate Processing Capacity(ft /h)
3

175
210
5.5kW
250 7.5kW
285
320
11kW 15kW
355
390
425
460 18.5kW
495
530 22kW
* This chart is for high temperature (355 °F) types, for low temperature types, please contact TLV.