Tractor function:
PTO activation only with driver seated.
Even if you want to activate the PTO from the mudguard you need to activate it from the
cab.
Press 2 sec. message (PTO enabled).
Press double click (activate cardan).
Seat sensor:
Now the seat sensor is on Agrotron K-M basic, P-line and X (practically all of them)
It was not on Agrotron K basic and P-line and Agrotron M basic.
If you are not seated it will not engage the shuttle.
If it breaks you can press the clutch pedal to move the tractor.
It is possible to disable it with the tester (only if necessary and with the inspector's
permission)
When you add a new version SC0076Al to an old tractor you need to disable the seat
sensor if it is not present, via password.
In hlhp
oo
Password FABE9E
Configuration
4 tc config
Seat 1-or 0
SAME
If you are not able to calibrate the shuttle you can set the engine on idle speed, but
you have to configure the control unit for this operation:
In hlhp
00
Password FABE9E
Configuration
4 tc config
EVP calib.engine (o/1)
PTO function
In HLHP
TECHNICAL TRAINING CENTRE
00
CENTRE DE FORMATION
INITIAL MENU:
PRESS TWICE 0 0
DEUTZ–FAHR ITALIA
From this screen, the user can select the type of Tractor
equipped with a ZF T7200 transmission
ERROR
DISPLAY
MODEL R7 DISPLAYED
SAME
INSTEAD OF R6
From this screen, the user can select the type of Tractor
equipped with a ZF T7300 transmission
From this screen, the user can select the type of Tractor
equipped with a ZF ECCOM 1.5 transmission
TRANSMISSION MODEL[
MODEL[ SMATIC ]
From this screen, the user can select the type of Tractor
equipped with a SMATIC transmission
CONFIRM CONFIGURATION
Having selected the tractor type, the user is prompted to switch the
starter key OFF and ON again
CENTRO DI FORMAZIONE TECNICA
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012
Contents
PRESENTATION SCREEN
From the main menu, press '2' to access the Calibration Menu
SAME
Type of transmission:
MENU – CONFIGURATION-
CONFIGURATION- TRANSMISSION
[ T7200 for M – IRON – R6 ]
Type of transmission:
AND ON AGAIN
MENU – CONFIGURATION-
CONFIGURATION- TRANSMISSION
[ T7330 for X – DIAMOND – R8 ]
Type of transmission:
Type of transmission:
Type of transmission:
There is only one type of SMATIC transmission currently available
.
40
CENTRO DI FORMAZIONE TECNICA
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012
MENU - CALIBRATION - TRANSMISSION [ T7X000 SERIES ]
AND ON AGAIN
CENTRO DI FORMAZIONE TECNICA
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
ALARM 11:
THE TRACTOR CAN KEEP RUNNING BUT SHOULD BE
CENTRO DI FORMAZIONE TECNICA
MENU - CALIBRATION -
MENU - CALIBRATION -
RUN THE
SAME
CALIBRATION
FOLLOWING THE
INDICATIONS
ON THE TESTER
CENTRO DI FORMAZIONE TECNICA
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012 CALIBRATION OF PROPORTIONAL P.T.O.
[if installed on tractor ]
Calibration error
Engine rpm not correct
Shuttle lever not in neutral position
Main gearshift lever not in neutral position
Communication error
[ 4 - XX ] unknown error
DEUTZ–FAHR ITALIA
1- Enable ASM
2- Disengagement of 4WD determined by steering angle
3- Disengagement of diff. lock Determined by steering angle
4- Disengagement of 4WD determined by ground speed
5- Disengagement of diff. lock Determined by ground speed
6- Selection of Carraro front axle
7- Calibration of steering sensor with Carraro axle
8- Configuration of front axle speed sensor. [S.Matic only]
SAME
1- Selection of options
2- Calibrations
3- Potentiometer calibrations
4- Calibration of basic armrest lift control joystick
5- Joystick values
DEUTZ–FAHR ITALIA
B - Buzzer activation
24
d
CENTRE DE FORMATION
ee
sp
gh
Hi
6
Low speed
Time in “
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012
CALIBRATION - AUTOMATIC LIFT CONTROL - POTENTIOM
Depth Min/Max
DEUTZ–FAHR ITALIA
1
SAME
7
CALIBRATION –SETTINGS
CENTRO DI FORMAZIONE TECNICA
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012
Integral 3‐valve unit (FOR M E 130‐185)
SAME
2‐valve unit 3‐valve unit
CENTRO DI FORMAZIONE TECNICA
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012
CALIBRATION MENU - SYSTEM
1.Select language
2.Select SDS display time on Infocenter
3.Activate climate control
4.Activate ISO11786 connection
5.Servicing: renewal of Filter
6.Servicing: change oil
7.Bio Diesel system
8.IMONITOR activation
9.Select auxiliary fuel tank yes/no (use only if
IMONITOR is active)
A.Select engine brake, M series only
B.Model/Year for type of console (see new consoles)
DEUTZ–FAHR ITALIA
0.017.8887.4
0.017.5884.4
In-cab wiring
0,017.5885.4/20
CENTRO DI FORMAZIONE TECNICA 2011 -2012
TECHNICAL TRAINING CENTRE SAME DEUTZ–FAHR ITALIA PHONE: +39/0363/421,486
CENTRE DE FORMATION FAX: +39/0363/423,486
CENTRO DI FORMAZIONE TECNICA 2011 -2012
TECHNICAL TRAINING CENTRE SAME DEUTZ–FAHR ITALIA PHONE: +39/0363/421,486
CENTRE DE FORMATION FAX: +39/0363/423,486
CENTRO DI FORMAZIONE TECNICA 2011 -2012
TECHNICAL TRAINING CENTRE SAME DEUTZ–FAHR ITALIA PHONE: +39/0363/421,486
CENTRE DE FORMATION FAX: +39/0363/423,486
CENTRO DI FORMAZIONE TECNICA 2011 -2012
TECHNICAL TRAINING CENTRE SAME DEUTZ–FAHR ITALIA PHONE: +39/0363/421,486
CENTRE DE FORMATION FAX: +39/0363/423,486
M - X series with Agro Ski
1.Selection of parameters
2.Programming of electrohydraulic spool valves
3.Setting of flow curves
4.Calibration of dead band central position
5.Setting advanced flow control (on TTV 630 only)
4 – Cal. Joystick
1
e
rv
Cu 3
2-
e
rv
Cu
DEUTZ–FAHR ITALIA
1 -2 3-4 5
SAME
TTV 630
Oil outlet selector
switch ( virt. Spool ) Spool valve
remains unchanged
1 2 3 4 5
1 2 3 4 1 2 3 4
DEUTZ–FAHR ITALIA
CAN spool valves PWM
Pin 1 = 12 V 12V
Pin 2 = CAN L *****
Pin 3 = CAN H Signal
Pin 4 = Earth Earth
SAME
1.Manual
1.Manual programming: Connectors must be connected one at a time and
and
then disconnected once programming is complete.
2.Sequential
2.Sequential programming: Connectors must be connected one after the
the
other, with valves that have been programmed remaining connected
SAME
Disconnect all spool valves, the connect one after the other
when prompted
DEUTZ–FAHR ITALIA
SAME
1.Straight line
2.Inverse quadratic curve
3.Inverse cubic curve
1
e
urv
C 3
2-
e
rv
Cu
DEUTZ–FAHR ITALIA
Disconnect the rod 29 and operate the level control valve to lower
the cab to its bottom travel limit.
CENTRO DI FORMAZIONE TECNICA
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012
CALIBRATION – MRD CAB (SEMIACTIVE)
CALIBRATION OF MAXIMUM HEIGHT POSITION
Operate the level control valve to bring the cab to its upper
travel limit.
DEUTZ–FAHR ITALIA
Position $$$
Cab levelling: OK - NO
dTravel Lh + 30 mm
dTravel Rh + 36 Travel delta in mm +62 / -62 maximum and minimum position.
SAME
mm
CENTRO DI FORMAZIONE TECNICA
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012
130 -185 hp
SPOOL 3
POS. MIN
Rear
SAME
SPOOL 4
POS. MIN SPOOL 4
IN FLOAT POS. MAX.
Front
SPOOL 3
POS. MAX.
IN FLOAT
CENTRO DI FORMAZIONE TECNICA
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
CENTRO DI FORMAZIONE TECNICA 2011 -2012
TECHNICAL TRAINING CENTRE SAME DEUTZ–FAHR ITALIA PHONE: +39/0363/421,486
CENTRE DE FORMATION FAX: +39/0363/423,486
MAIN MENU
ACTUAL RANGE
RANGE REQUIRED
DEUTZ–FAHR ITALIA
ERROR CODE
LIFT POSITION [ %]
P.T.O. DISENGAGEMENT LIMIT [ % ]
CENTRO DI FORMAZIONE TECNICA
VEHICLE SPEED
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012
SPEED [ km/h ]
WHEELSLIP [ ON – OFF ]
VALUE IN % SET
WITH POTENTIOMETER
NOT USED
ACTUAL MAP
REQUIRED MAP
P GRADE ACTIVATED
ACTUAL ENGINE RPM
(TRANSMISSION)
DEUTZ–FAHR ITALIA
1.Digital inputs
2.Analog inputs 1
3.Analog inputs 2
4.Digital outputs
SAME
STATUS OF ROAD (V) CONTROL SOLENOID VALVE [ ON – OFF ] for T7100 only
7200
TECHNICAL TRAINING CENTRE
7100
CENTRE DE FORMATION
7300
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012
NOT AVAILABLE
SAME
NOT AVAILABLE
ENABLE
DECR.
REV
FWD
CENTRO DI FORMAZIONE TECNICA
TECHNICAL TRAINING CENTRE
CENTRE DE FORMATION
POTENTIOMETER ACCEL.
ECO - POWER
FAX: +39/0363/423,486
PHONE: +39/0363/421,486
2011 -2012
MAIN MENU - TEST – TRANSMISSION -
LCO
STATUS OF RH BRAKE PEDAL SWITCH
VEHICLE SPEED
CONTROL
ALARMS:
VERSION SC 0076 AH
UNIFIED HLHP SOFTWARE
CENTRO DI FORMAZIONE TECNICA 2011 -2012
TECHNICAL TRAINING CENTRE SAME DEUTZ–FAHR ITALIA PHONE: +39/0363/421,486
CENTRE DE FORMATION FAX: +39/0363/423,486
MENU - ALARMS
MENU - ALARMS
FMI = CAUSE
SPN = ALARM
MENU - ALARMS
MENU - ALARMS