You are on page 1of 19

8 7 6 5 4 3 2 1

REVISIONS
NOTE:- SYM DESCRIPTION
W CHANGED: UPDATED
DRAWING VIEWS TO BE
1. MAXIMUM FIELD RETROFIT RAIN LIP SIZE WITHOUT REQUIRING ADAPTER PLATE: 17-1/2 X 39-1/2 X 2" MORE READABLE AND
ADDED GEN 1,2,3 AND
4 FOOTPRINTS
2 FOR X+1 SELECTABLE BLENDER AND 3+1 MULTI HOSE BLENDER, INLET "Y" IS THE PLUS GRADE. ECO DATE WMH
H H
0675404 08/28/14
INLET POSITIONS FOR STANDARD FLOW MODELS Y CHANGED: UPDATED
DRAWING VIEWS TO BE
3 FOR 3+1 SINGLE HOSE, INLET "Z" IS THE PLUS GRADE. MORE READABLE
FOR 3+1+1 SELECTABLE BLENDER, INLETS "Y" AND "Z" ECO DATE TCS
1000006 12/23/15
ARE THE PLUS GRADES.
AA CHANGED: NOTES IN
FOR 3+2 MULTI HOSE BLENDER, INLETS "W" AND "X" ARE SHT1, DIMENSIONS IN
USED FOR SELECTABLE BLENDER SIDE (SINGLE HOSE SHT2, TABLE IN SHT
3 AND ADDED NOTE
ON THE RIGHT SIDE OF THE UNIT ) AND INLETS "Y" AND "Z" 8 IN SHT2.
ARE USED FOR THE MULTI HOSE BLENDER SIDE ECO DATE TCS
(2 HOSES ON THE LEFT SIDE OF THE UNIT). 1001363 08/30/16

FOR NJ5- INLET "W" MUST BE THE LOW GRADE NON FLEX,
G INLET "X" MUST BE THE HI GRADE NONFLEX, G
AND INLET "Y" MUST BE THE FLEX PRODUCT.
Z Y X W FOR NJ6, THE INLETS ARE THE SAME AS NJ5,
EXCEPT ADD INLET "Z" WHICH IS DIESEL, THE PLUS ONE GRADE

4
THESE DIMENSIONS ARE FOR "S" CURVED SHEATHING.

5 THESE DIMENSIONS ARE FOR DEF "S" CURVED SHEATHING.


F F

6 INLET UNION PART NUMBER X22468 AND CHECK VALVE PART NUMBER N23274 CAN BE ORDERD AS A
CUSTOMER OPTION

7 SMART METER DISPENSERS USES THE SAME LAYOUT OF ECOMETER

PRODUCT INLET TABLE TABLE OF CONTENTS


E E

INLET PRODUCT SHEET NO. LAYOUT DESCRIPTION MODELS PRODUCTION DATE


W 1
2 FIELD ELECTRICAL CONDUIT PLACEMENT - -
X 2
3 DISPENSERS WITH PISTON METER DETAILS ON SHEET 3 -
Y 3
D D
Z 4 4 SELF CONTAINED WITH PISTON METER DETAILS ON SHEET 4 -

5 ELECTRICAL CONDUIT LAYOUT - -

NP3/NP4/NP5/NP6/
6-9 ULTRA-HI GEN 4 WITH DEF OCTOBER 2014 TO PRESENT
NPA/NPB/NPC

C
10 DEF LAYOUT - - C

NP3/NP4/NA4/NPA/
11-13 ULTRA-HI GEN 3 JANUARY 2013 TO SEPTEMBER 2014
NPB/NP5
NP3/NP4/NP5/NPA/ GEN1: JUNE 2002 TO JANUARY 2009
14-18 ULTRA-HI GEN 1 & GEN 2
NA4/NPB GEN2: FEBRUARY 2009 TO DECEMBER 2012
REFERENCE DOCUMENTS:
19 DISPENSERS WITH ECOMETER DETAILS ON SHEET 19 -
B B
MDE-3985 : ENCORE INSTALLATION MANUAL
MDE-3802 : ENCORE SITE PREPARATION MANUAL
FE-363 : ENCORE FIELD WIRING DIAGRAM

A LEGAL NOTICE
This document contains
FINAL PROTECTIVE FINISH c Gilbarco Inc. A
c Gasboy International LLC
proprietary information
of Gilbarco Inc. See M00800
for legal instructions MATERIAL FOUNDATION LAYOUT
UNLESS OTHERWISE SPECIFIED:
ENCORE
* DIMENSIONS ARE IN MILLIMETERS (mm). SCALE
DR TCS DO NOT SCALE
* FOR TOLERANCES SEE THE SH
NO. 1 OF 19
LATEST REVISION OF M00800. CK APP
ECO SYM REV
* THIRD ANGLE PROJECTION
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

EXTENDED REACH NOTE:-


(OPTION)
8 THE DIMENSION 4-1/4 INCLUDES THE HATCHED AREA OF 5/8 DIMENSION IN ISO VIEW.
THE DIMENSION 4-1/4 IS FROM BOLT CENTER TO OUTSIDE FACE OF CENTER BRACE.
H
LEGEND: H

3-7/8

EXTENDED REACH
OPTIMAL CONDUIT LOCATION
OPTIONAL PART, CONDUIT
SEE DETAIL A
NOT RECOMMENDED
B SIDE
OPTIMAL CONDUIT LOCATION
G G

8
OPTIMAL 1-5/8
CONDUIT 4-1/4
LOCATION
15-1/4 23-3/4

F EXTENDED REACH F

A SIDE CENTER BRACE


4-1/4
40-3/8

LOWER FRAME (M14396) 4-7/8


E 1 E
WITH RECTANGULAR SHEATHING
5
2-7/8
DETAIL-A
ADDITIONAL USABLE AREA FOR CONDUIT,
IF EXTENDED REACH NOT PRESENT
5

SIDE-A 5-1/8

VIEW
D D

3-7/8
SEE DETAIL B
EXTENDED REACH OPTION

B SIDE
COLUMN SHEATHING
FOOTPRINT

C EXTENDED REACH C
8

OPTIMAL THIS HATCHED AREA CANNOT BE USED


CONDUIT 8 4-1/4 FOR CONDUIT POSITION
LOCATION CONDUIT IN THIS AREA WILL HIT
8 5/8
THE FLANGE OF CENTER BRACE
23-3/4
2-1/2 4-1/4
15-1/4

B B

EXTENDED REACH OPTION


A SIDE
FIELD ELECTRICAL CONDUIT PLACEMENT
40-3/8
( DIMENSIONS ARE IN INCHES )

LOWER FRAME (M14396)


A A
WITH CURVED SHEATHING
1

SCALE SH
NO.2 OF 19
DETAIL-B DO NOT SCALE
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H
DISPENSER TOP VIEW

40-9/16 OR 44 7/8 VAPOR RECOVERY


HEALY VAPOR PUMP
36-5/8 CONTAINMENT SUMP LOCATION
LOCATION WHEN
15-1/8 20-1/4
PROVIDED
28-3/4
1" CONDUIT 14-3/8 9-1/2 CALL W/SPKR J-BOX 3/4" CONDUIT
FOR POWER OPENING WHEN PROVIDED
G AND 2 WIRE G
9-1/8 9-1/4
LOCATED SIDE B
6-3/16
THIS SIDE - OPENING
SEE SHEET 5 FOR 3/4"
(UNITS LESS ISD
JUNC BOX) JUNC BOX
11-7/8 CONDUIT
WHEN
10-1/16 PROVIDED
23-3/4
4
OR
5-5/8 X W 4-7/8
5-13/16
24 1/16
F F
20-1/8

17-3/4 Z Y
7-11/16

1" CONDUIT FOR ETHERNET


E SIDE A AND/OR INTERCOM (WHEN E
9 9 REQUIRED) LOCATED THIS SIDE
OPENING FOR 1/2" CANOPY 4-5/8 SEE SHEET 2
LIGHT AUX JUNC BOX 9-3/8
WHEN PROVIDED
17-1/8
(4) 13/16 X 1-7/16
ANCHOR BOLT SLOTS

D D
CALL W/SPKR J-BOX
SIDE A VIEW WHEN PROVIDED

ISD J-BOX
1-1/2 NPT PRODUCT WHEN PROVIDED INLETS MODEL# DISPENSER MODELS
INLET COUPLINGS
W NA0 1 GRADE 2 HOSE MPD
NA1 2 GRADE 4 HOSE MPD
NG4 2 GRADE SINGLE HOSE MPD
W & X
C NN1/NN2/NN3 X+0 SELECTABLE BLENDER C

CANOPY LIGHT NJ0 3 GR MULTI HOSE BLENDER


AUX JUNC BOX
WHEN PROVIDED NA2 3 GRADE 6 HOSE MPD
NG0 3 GRADE SINGLE HOSE MPD
W,X & Y NL0/NL1/NL2 X+1 SELECTABLE BLENDER 2 3

NJ2 3+1 MULTI HOSE BLENDER


11-1/2 15-5/8 NJ5 5+0 MULTI HOSE HYBRID BLENDER
10-5/8
13-1/8 NA3 4 GRADE 8 HOSE MPD
B 10 B
10-11/16 NG1 3+1 SINGLE HOSE MPD
W,X,Y & Z NL3 3+1+1 SELECTABLE BLENDER
4-1/4 3
NJ4 3+2 MULTI HOSE HYBRID BLENDER
NJ6 4+1 MULTI HOSE HYBRID BLENDER
1" NPT VAPOR COUPLING
POWER JUNC BOX HEALY VAPOR PUMP WHEN PROVIDED (WITH
CAPPED L
WHEN PROVIDED WHEN PROVIDED ADDITION OF ISD FLOWMETER
ENABLE OR READY HEIGHT
SIDE A OF UNIT CHANGES TO 8 INCHES.) DISPENSERS WITH PISTON METERS
A
PRIMARY ELECTRICAL SERVICE SIDE (DIMENSIONS ARE IN INCHES)
A

SCALE SH
DO NOT SCALE NO.3 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H

PUMPER TOP VIEW

4 1" NPT MALE CONDUIT


FOR ETHERNET OPTION
40-9/16 OR 44 7/8
27-3/4
G 20-7/16 G
5-7/8 13-15/16
SIDE B
2-1/16 2-11/16
1-13/16 4-1/4

17-3/4
Z 5-7/16
15-7/8
F F
23-3/4
OR 4
20-1/8 24 1/16
Y W

INLETS MODEL# PUMP MODELS


W NC0 1 GRADE 2 HOSE MPP
SIDE A 1" NPT FEMALE FITTING
OPENING FOR 1/2" CANOPY 3/4 FOR VAPOR RECOVERY OPTION
NC1 2 GRADE 4 HOSE MPP
E LIGHT AUX JUCTBOX OPTION NG5 2 GRADE SINGLE HOSE MPP E
8-1/4
26-11/16 W & X NN5/NN6/NN7 X+0 SELECTABLE BLENDER
(4) 13/16 X 1-7/16
28-3/4
ANCHOR BOLT SLOTS
NJ1 3 GR MULTI HOSE BLENDER
30-9/16
NC2 3 GRADE 6 HOSE MPP
1" CONDUIT FOR PUMPING NG2 3 GRADE SINGLE HOSE
UBIT J-BOX CONNECTION W,X & Y X+1 SELECTABLE BLENDER
2
NL4/NL5/NL6
NJ3 3+1 MULTI HOSE BLENDER
SIDE A VIEW W,X,Y & Z
NC3 4 GRADE 8 HOSE MPP 3
D NG3 3+1 SINGLE HOSE MPP D

SIDE B VIEW

1" NPT MALE


J-BOX CONDUIT
C C

CANOPY LIGHT AUX


JUNC BOX OPTION 1" NPT MALE
CONDUIT
FOR ETHERNET
(OPTION)

1-1/2" NPT
PRODUCT INLET 1" NPT FEMALE
FITTING
B 10 FOR VAPOR B
RECOVERY
5-7/8 (OPTION)

9-3/16
9-1/16

SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE

SIDE B OF UNIT
A A

SELF CONTAINED WITH PISTON METER


( ALL DIMENSIONS ARE IN INCHES )
SCALE SH
DO NOT SCALE NO.4 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

VAPOR BARRIER PLATE


16-3/4
H 1-5/8 8-3/8 H
CONDUIT KNOCKOUTS 1-5/8
FOR 1" CONDUITS
4 EACH SIDE-8 TOTAL

ELECTRICAL CONDUIT LAYOUT


13/16

1 2 1-5/8
5 6
G G

3 4 7 8

CONDUIT KNOCKOUTS
LOCATED ON CD MODULE
4 EACH SIDE - 8 TOTAL
F F

9 10 13 14

11 12 15 16
E E

ADA LINE

CONDUIT KNOCKOUTS
LOCATED ON VAPOR
BARRIER PLATES AT
THESE LOCATIONS
D D

C C

42

35

B B

ISLAND

6 TYP

A A
LEFT SIDE RIGHT SIDE
SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE
SCALE SH
NO.5 OF 19
( ALL DIMENSIONS ARE IN INCHES ) DO NOT SCALE
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

5 (4) 13/16 X 1-7/16


1" CONDUIT FOR POWER ANCHOR BOLT SLOTS
53-1/16 OR 57-3/8
H AND 2 WIRE LOCATED 5 H
THIS SIDE - SEE SHEET 5 53-1/16 OR 57-3/8 1" CONDUIT FOR
4
(UNIT LESS JUNC BOX) ETHERNET
40-9/16 OR 44-7/8
AND/OR
20-1/4 INTERCOM (WHEN
36-5/8 REQUIRED)
DEF CABINET 28-3/4 LOCATED THIS
LEFT HAND 14-3/8 SIDE
CONFIGURATION 5-1/2 11-7/8 5-1/2 SEE SHEET 5
9-1/8 9-1/4
SIDE B
G DEF 1" MALE NPT G

11-7/8
10-1/16 2-3/4
W
20-1/8 X
15-1/8
24-1/16 17-3/4
4 OR
23-3/4 14-1/8 15-1/8
Y 11-15/16

6 Z 8-3/16

F F

SIDE A
5-7/16
20-11/16 16-11/16
DEF 1" MALE NPT 12-1/16 DEF CABINET
3/4 NPT MALE 23-5/16 RIGHT HAND
CONDUIT 49-7/16 CONFIGURATION
FOR POWER
JUNCTION BOX
WHEN PROVIDED
E E

1-1/2" NPT OUTLET TO SATELLITE DEF 1" MALE NPT


(SUPPLIED WITH UNION)
DEF 1" MALE NPT

D D

Z W
6
STRAINER ASSEMBLY 30
30

X Y 20
17-7/16
12-1/2
C 11 C

2" NPT INLET FROM TANK


POWER JUNC BOX
WHEN PROVIDED
SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE

B B
POSITION 1 GRADE 1 HOSE SINGLE MASTER 1 GRADE 2 HOSE DUAL MASTER
W OUTLET TO SATELLITE - SIDE1 OUTLET TO SATELLITE - SIDE1
X INLET FROM TANK - SIDE1 INLET FROM TANK - SIDE1
Y NOT USED INLET FROM TANK - SIDE2
Z NOT USED OUTLET TO SATELLITE - SIDE2 GEN 4
PRODUCTION : OCTOBER 2014 TO PRESENT

ULTRA HI MASTER-MODEL NP3


A A
ULTRA HI MASTER-MODEL WITH DEF, NPA
(DIMENSIONS ARE IN INCHES)
SCALE SH
DO NOT SCALE NO.6 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

5 (4) 13/16 X 1-7/16


53-1/16 OR 57-3/8 ANCHOR BOLT SLOTS
H 1" CONDUIT FOR POWER 5 H
AND 2 WIRE LOCATED 53-1/16 OR 57-3/8 1" CONDUIT FOR
THIS SIDE - SEE SHEET 5 4 ETHERNET
(UNIT LESS JUNC BOX) 40-9/16 OR 44-7/8 AND/OR
INTERCOM (WHEN
20-1/4
REQUIRED)
36-5/8 LOCATED THIS
28-3/4 SIDE
DEF CABINET 14-3/8 SEE SHEET 5
LEFT HAND 5-1/2 11-7/8 5-1/2
CONFIGURATION 9-1/8 9-1/4
SIDE B
G G
DEF 1" MALE NPT

11-7/8 W
10-1/16
24-1/16 2-3/4 X
4 OR 17-3/4
23-3/4 15-1/8

20-1/8 14-1/8 15-1/8


11-15/16
Y
6
F F

SIDE A
20-11/16 5-7/16
DEF 1" MALE NPT 16-11/16
23-5/16 DEF CABINET
49-7/16 RIGHT HAND
3/4 NPT MALE CONFIGURATION
CONDUIT
FOR POWER
JUNCTION BOX
WHEN PROVIDED
E E

1-1/2" NPT INLET FROM MASTER


(SUPPLIED WITH UNION)
1-1/2" NPT OUTLET TO SATELLITE
(SUPPLIED WITH UNION) DEF 1" MALE NPT

DEF 1" MALE NPT

D D

W Y
6 STRAINER ASSEMBLY
30 30

17-7/16 X 20-3/8
20

C 12-1/2 C
11

POWER JUNC BOX


WHEN PROVIDED 2" NPT INLET FROM TANK
SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE

B B
POSITION MASTER / SATELLITE COMBO
W OUTLET TO SATELLITE - SIDE 1- MASTER SIDE
X INLET FROM TANK - SIDE 1- MASTER SIDE
Y INLET FROM MASTER - SIDE 2 - SATELLITE SIDE
Z NOT USED
GEN 4
ULTRA HI MASTER/SATELLITE COMBO-MODEL NP4 PRODUCTION : OCTOBER 2014 TO PRESENT

A
ULTRA HI MASTER/SATELLITE COMBO-MODEL WITH DEF, NPB A

(DIMENSIONS ARE IN INCHES)


SCALE SH
DO NOT SCALE NO.7 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H

4
1" CONDUIT
FOR POWER 44-7/8 OR 40-9/16
AND 2 WIRE
20-1/4
LOCATED
THIS SIDE - 36-5/8 (4) 13/16 X 1-7/16 NOTE:- DEF UNITS ARE NOT INSTALLED ON
ANCHOR BOLT SLOTS
SEE SHEET 5 28-3/4
SATELLITE MODELS
(UNIT LESS 14-3/8
JUNC BOX) 11-7/8
9-1/8
G SIDE B G

11-7/8 X
10-1/16
24-1/16 2-3/4
4 OR
23-3/4 20-1/8 17-3/4
Y
14-1/8

6
F F

SIDE A
5-7/16
23-5/16
3/4 NPT MALE
CONDUIT
FOR POWER
JUNCTION BOX
WHEN PROVIDED
1-1/2" NPT INLET FROM MASTER
E E
(SUPPLIED WITH UNION)
(OPTIONAL W/STAINER ASSEMBLY)

D D

X Y

20-3/8 20-3/8

11

C C

POWER JUNC BOX


WHEN PROVIDED

SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE

B
POSITION 1 GRADE 1 HOSE SINGLE SATELLITE 1 GRADE 2 HOSE DUAL SATELLITE 2 GRADE 2 HOSE SINGLE SIDED DUAL SATELLITE B
W NOT USED NOT USED NOT USED
X INLET FROM MASTER - SIDE 1 INLET FROM MASTER - SIDE 1 INLET FROM MASTER - SIDE 1
Y NOT USED INLET FROM MASTER - SIDE 2 INLET FROM MASTER - SIDE 2
Z NOT USED NOT USED NOT USED

GEN 4
ULTRA HI SATELLITE-MODEL NP5 PRODUCTION : OCTOBER 2014 TO PRESENT

A ULTRA HI SINGLE SIDED DUAL SATELLITE-MODEL NP8 A

(DIMENSIONS ARE IN INCHES)

SCALE SH
DO NOT SCALE NO.8 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

5
53-1/16 OR 57-3/8 (4) 13/16 X 1-7/16
5 ANCHOR BOLT SLOTS
1" CONDUIT FOR POWER 53-1/16 OR 57-3/8
H H
AND 2 WIRE LOCATED 4
1" CONDUIT FOR ETHERNET
THIS SIDE - SEE SHEET 5 40-9/16 OR 44-7/8 AND/OR INTERCOM (WHEN
(UNIT LESS JUNC BOX) 20-1/4 REQUIRED) LOCATED THIS SIDE
36-5/8
28-3/4 SEE SHEET 5
14-3/8
DEF CABINET
11-7/8 5-1/2
LEFT HAND 5-1/2
9-1/8 9-1/4
CONFIGURATION SIDE B

DEF 1" MALE NPT


G
11-7/8 W G
10-1/16 X
20-1/8
15-1/8
2-3/4
24-1/16
4 OR 17-3/4
Z 14-1/8
23-3/4
Y 11-15/16 15-1/8
8-3/16
6

F F
DEF 1" MALE NPT 20-11/16 5-7/16 SIDE A
12-1/16
3/4 NPT MALE CONDUIT
FOR POWER JUNCTION BOX 16-11/16 DEF CABINET
WHEN PROVIDED
RIGHT HAND
23-5/16
CONFIGURATION
49-7/16

E E

1-1/2" NPT OUTLET TO SATELLITE


(SUPPLIED WITH UNION) DEF 1" MALE NPT

DEF 1" MALE NPT

D D

Z W
6 STRAINER ASSEMBLY 30

30
X Y 20
17-7/16
12-1/2
C 11 C

POWER JUNC BOX 2" NPT INLET FROM TANK


WHEN PROVIDED

SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE
B B

POSITION SINGLE SIDED 2 GRADE 2 HOSE DUAL PRODUCT MASTER + DEF


W OUTLET TO SATELLITE - SIDE1, HOSE OUTLET POS A
GEN 4
X INLET FROM TANK - SIDE1, HOSE OUTLET POS A
PRODUCTION : OCTOBER 2014 TO PRESENT
Y INLET FROM TANK - SIDE1, HOSE OUTLET POS E
Z OUTLET TO SATELLITE - SIDE 1, HOSE OUTLET POS E

A
ULTRA HI SINGLE SIDED DUAL MASTER-MODEL NP6 A

ULTRA HI SINGLE SIDED MASTER-MODEL WITH DEF, NPC


(DIMENSIONS ARE IN INCHES) SCALE
DO NOT SCALE
ECO
SH
NO.9 OF 19
REV
SYM
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

DEF- LAYOUT
H H

G G

60

DEF RIGHT
DEF LEFT
F F

29

E E

DISPENSER DEF INLET


D D
94

C C

B B

PIT BOX TYPICAL

A A

SCALE SH
DO NOT SCALE NO.10 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

4 4

H 40-9/16 OR 44-7/8 40-9/16 OR 44-7/8 H


20-1/4 20-1/4
36-5/8 36-5/8
1" CONDUIT FOR POWER 28-3/4 1" CONDUIT FOR POWER 28-3/4 1" CONDUIT FOR ETHERNET
AND 2 WIRE LOCATED 14-3/8 AND 2 WIRE LOCATED AND/OR INTERCOM (WHEN
THIS SIDE - SEE SHEET 5
9-1/8 9-1/4 THIS SIDE - SEE SHEET 5 14-3/8 REQUIRED) LOCATED THIS SIDE
(UNITS LESS JUNC BOX)
(UNITS LESS JUNC BOX) 9-1/8 9-1/4 SEE SHEET 5
7-1/4
SIDE B 7-1/4
1" CONDUIT FOR ETHERNET
OR ITSF AND/OR INTERCOM (WHEN SIDE B
REQUIRED) LOCATED THIS SIDE
G SEE SHEET 5 G

23-3/4 11-7/8 W 23-3/4 11-7/8 W


4
OR 10-1/16
4 OR
X 10-1/16
24-1/16 17-3/4 24-1/16 17-3/4 1-1/4 X

20-1/8 15-15/16 15-15/16


Z 20-1/8
1-1/4 Y
Y 4-1/8 4-1/8

F F
SIDE A SIDE A
1
(4) 13/16 X 1-7/16 3/4 NPT MALE CONDUIT 11-15/16
3/4 NPT MALE CONDUIT 11-15/16 FOR POWER JUNC BOX (4) 13/16 X 1-7/16
FOR POWER JUNC BOX ANCHOR BOLT SLOTS 16-13/16 ANCHOR BOLT SLOTS
WHEN PROVIDED
WHEN PROVIDED 16-13/16
29-3/4
29-3/4

E E

1-1/2" NPT OUTLET TO SATELLITE


1-1/2" NPT INLET FROM MASTER (SUPPLIED WITH UNION)
(SUPPLIED WITH UNION)

1-1/2" NPT OUTLET TO SATELLITE


1-1/2" NPT INLET FROM MASTER (SUPPLIED WITH UNION)
(SUPPLIED WITH UNION)

D D

W Z
Y X
20-1/8 W Y
17-7/16
17-7/16 X
20-15/16
13-7/16

C 20-1/8 C

13-7/16 17-7/16

2" NPT INLET FROM TANK 6


POWER JUNC BOX
WHEN PROVIDED
POWER JUNC BOX 2" NPT INLET FROM TANK 6

SIDE A OF UNIT WHEN PROVIDED


SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE PRIMARY ELECTRICAL SERVICE SIDE
B B

POSITION 1 GRADE 1 HOSE SINGLE MASTER 1 GRADE 2 HOSE DUAL MASTER GEN 3 POSITION MASTER/SATELLITE COMBO
W OUTLET TO SATELLITE - SIDE 1 OUTLET TO SATELLITE - SIDE 1 PRODUCTION: JANUARY 2013 TO W OUTLET TO SATELLITE - SIDE 1 - MASTER SIDE
X INLET FROM TANK - SIDE 1 INLET FROM TANK - SIDE 1 SEPTEMBER 2014 X INLET FROM TANK - SIDE 1 - MASTER SIDE
Y NOT USED INLET FROM TANK - SIDE 2 Y INLET FROM MASTER - SIDE 2 - SATELLITE SIDE
Z NOT USED INLET FROM SATELLITE - SIDE 2
NOTE:- NOT IN CURRENT PRODUCTION Z NOT USED
A A
ULTRA HI MASTER-MODEL NP3 ULTRA HI COMBO-MODEL NP4
(DIMENSIONS ARE IN INCHES) (DIMENSIONS ARE IN INCHES)
SCALE SH
DO NOT SCALE NO.11 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

1" CONDUIT FOR ETHERNET 1" CONDUIT FOR ETHERNET


5
AND/OR INTERCOM (WHEN AND/OR INTERCOM (WHEN
53-1/16 OR 57-3/8
5 REQUIRED) LOCATED THIS
5 REQUIRED) LOCATED THIS
1" CONDUIT 53-1/16 OR 57-3/8 SIDE
53-1/16 OR 57-3/8 SIDE
H FOR POWER SEE SHEET 5
5 SEE SHEET 5 H
4 1" CONDUIT FOR POWER
53-1/16 OR 57-3/8
AND 2 WIRE 40-9/16 AND 2 WIRE LOCATED 4 DEF CABINET
LOCATED THIS SIDE - SEE SHEET 5 40-9/16 OR 44-7/8 RIGHT HAND CONFIGURATION
THIS SIDE - 36-5/8
DEF CABINET (UNITS LESS JUNC BOX)
SEE SHEET 5 36-5/8
28-3/4 RIGHT HAND CONFIGURATION
(UNITS LESS 14-3/8 20-1/4
28-3/4
JUNC BOX) 14-3/8 20-1/4
9-1/8 9-1/4 SIDE B
5-1/2 7-1/4 5-1/2 9-1/8 9-1/4 5-1/2
5-1/2
SIDE B 7-1/4 DEF 1" MALE NPT
DEF 1" MALE NPT
G G
W
11-7/8
11-7/8 W
20-1/8 10-1/16
15-1/8 X 10-1/16
X
15-1/8
15-15/16 20-1/8
24-1/16 24-1/16 15-15/16
4 OR 17-3/4 4 OR 17-3/4
23-3/4 1-1/4 15-1/8 15-1/8
Y Z 23-3/4 1-1/4
Y
4-1/8 4-1/8

F F
SIDE A SIDE A
5/16
DEF 1" MALE NPT (4) 13/16 X 1-7/16
11-15/16 11-15/16
ANCHOR BOLT SLOTS
20-11/16 16-13/16
DEF 1" MALE NPT 20-11/16 16-13/16
DEF CABINET (4) 13/16 X 1-7/16
29-3/4
LEFT HAND CONFIGURATION DEF CABINET
29-3/4 ANCHOR BOLT SLOTS
3/4 NPT MALE 49-7/16 LEFT HAND CONFIGURATION 49-7/16
CONDUIT
FOR POWER JUNC BOX 3/4 NPT MALE CONDUIT
WHEN PROVIDED FOR POWER JUNC BOX
E WHEN PROVIDED E

1-1/2" NPT OUTLET TO SATELLITE


1-1/2" NPT INLET FROM MASTER (SUPPLIED WITH UNION)
(SUPPLIED WITH UNION) 1-1/2" NPT INLET FROM MASTER 1-1/2" NPT OUTLET TO SATELLITE
(SUPPLIED WITH UNION) (SUPPLIED WITH UNION)
DEF 1" MALE NPT DEF 1" MALE NPT
DEF 1" MALE NPT DEF 1" MALE NPT

D D

W Z W Y
30 Y X 30 X
30 30
20-1/8
20-1/8
C 17-7/16 17-7/16 C
17-7/16 20-15/16
13-7/16
13-7/16

POWER JUNC BOX


POWER JUNC BOX 2" NPT INLET FROM TANK WHEN PROVIDED
6 2" NPT INLET FROM TANK 6
WHEN PROVIDED SIDE A OF UNIT
SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE PRIMARY ELECTRICAL SERVICE SIDE
B B

POSITION MASTER/SATELLITE COMBO


POSITION 1 GRADE 1 HOSE SINGLE MASTER 1 GRADE 2 HOSE DUAL MASTER W OUTLET TO SATELLITE - SIDE 1 - MASTER SIDE
W OUTLET TO SATELLITE - SIDE 1 OUTLET TO SATELLITE - SIDE 1 X INLET FROM TANK - SIDE 1 - MASTER SIDE
X INLET FROM TANK - SIDE 1 INLET FROM TANK - SIDE 1 Y INLET FROM MASTER - SIDE 2 - SATELLITE SIDE
Y NOT USED INLET FROM TANK - SIDE 2 GEN 3 Z NOT USED
Z NOT USED OUTLET TO SATELLITE - SIDE 2 PRODUCTION: JANUARY 2013 TO
SEPTEMBER 2014 ULTRA HI COMBO-MODEL NPB
A ULTRA HI MASTER-MODEL NPA & NA4 (DEF ONLY) A
(DIMENSIONS ARE IN INCHES)
(DIMENSIONS ARE IN INCHES)
NOTE:- NOT IN CURRENT PRODUCTION

SCALE SH
DO NOT SCALE NO.12 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H 4 H
40-9/16 OR 44-7/8
1" CONDUIT FOR POWER 36-5/8
AND 2 WIRE LOCATED
28-3/4
THIS SIDE - SEE SHEET 5
(UNITS LESS JUNC BOX) 14-3/8 20-1/4

9-1/8

SIDE B
G G
X
11-7/8

20-1/8 10-1/16

23-3/4 17-3/4
4 OR 15-15/16
24-1/16
1-1/4 Y

4-1/8

F F
SIDE A

7-1/4
(4) 13/16 X 1-7/16
12-1/2 ANCHOR BOLT SLOTS
3/4 NPT MALE CONDUIT
FOR POWER JUNC BOX
16-1/4
WHEN PROVIDED

E E

1-1/2" NPT INLETS FROM MASTERS


(SUPPLIED WITH UNION, STANDARD)
(OPTIONAL W/STRAINER ASSEMBLY)

D D

X Y

20-15/16

13-7/16
C C

POWER JUNC BOX


WHEN PROVIDED

SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE

B GEN 3 NOTE:- NOT IN CURRENT PRODUCTION B


PRODUCTION: JANUARY 2013 TO
SEPTEMBER 2014

POSITION SATELLITE
W NOT USED
X INLET FROM MASTER - SIDE 1
Y INLET FROM MASTER - SIDE 2
Z NOT USED
A A

ULTRA HI SATELLITE-MODEL NP5


(DIMENSIONS ARE IN INCHES) SCALE SH
DO NOT SCALE NO.13 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H

40-9/16 OR 44 7/8
36-5/8
4
14-3/8
1" CONDUIT FOR POWER 40-9/16 OR 44-7/8
1" CONDUIT FOR POWER 28-3/4
AND 2 WIRE LOCATED 36-5/8 1" CONDUIT FOR ETHERNET AND/OR
AND 2 WIRE LOCATED 20-7/16
THIS SIDE - SEE SHEET 5 INTERCOM (WHEN
THIS SIDE - SEE SHEET 5 8-5/16 20-1/4 14-3/8 20-1/4
(UNITS LESS JUNC BOX) REQUIRED) LOCATED THIS SIDE
(UNITS LESS JUNC BOX) 9-1/8 9-1/4 SIDE B 28-3/4
SEE SHEET 5
SIDE B
G 1" CONDUIT FOR ETHERNET G
AND/OR INTERCOM (WHEN
REQUIRED) LOCATED THIS
SIDE 11-7/8
X
11-7/8
Y SEE SHEET 5 10-1/16
20-1/8 10-1/16 20-1/8
23-3/4 17-3/4
23-3/4 17-3/4 4 OR
W
4 OR 4-3/8 24 1/16
4-3/8
14
6-15/16
24 1/16 6-15/16
W 12-3/8 11-3/4
X 7-11/16
5-1/2 5-3/4
F F

SIDE A 1-9/16
SIDE A
1-9/16 16-11/16
OPENING FOR 1/2" CANOPY OPENING FOR 1/2" CANOPY
LIGHT AUX JUNC BOX 16-11/16 LIGHT AUX JUNC BOX 20-7/16 (4) 13/16 X 1-7/16
WHEN PROVIDED 28-1/2 (4) 13/16 X 1-7/16 WHEN PROVIDED 28-1/2 ANCHOR BOLT SLOTS
ANCHOR BOLT SLOTS
3/4 NPT MALE CONDUIT
3/4 NPT MALE CONDUIT FOR POWER JUNC BOX
FOR POWER JUNC BOX WHEN PROVIDED
WHEN PROVIDED
E E

POWER JUNC BOX


WHEN PROVIDED
POWER JUNC BOX
WHEN PROVIDED

2" NPT INLET FROM MASTER


(SUPPLIED WITH UNION)
D D
2" NPT OUTLET TO SATELLITE
1-1/2" NPT OUTLET TO SATELLITE
(SUPPLIED WITH UNION)
(SUPPLIED WITH UNION)
CANOPY LIGHT
CANOPY LIGHT AUX JUNC BOX
AUX JUNC BOX WHEN PROVIDED
WHEN PROVIDED

W
C
X W C
10 Y 10-3/16 X
6-15/16 10 10-3/16
5-1/8
5-1/8

2" NPT INLET FROM TANK 6

SIDE A OF UNIT SIDE A OF UNIT


PRIMARY ELECTRICAL SERVICE SIDE PRIMARY ELECTRICAL SERVICE SIDE 2" NPT INLET FROM TANK 6

B GEN 1 GEN 2 B

PRODUCTION: JUNE 2002 TO PRODUCTION: FEBRUARY 2009 TO


JANUARY 2009 DECEMBER 2012
NOTE:NOT IN CURRENT PRODUCTION ALTERNATE FOOTPRINT
STANDARD FOOTPRINT
POSITION 1 GRADE 1 HOSE SINGLE MASTER
POSITION 1 GRADE 1 HOSE SINGLE MASTER 1 GRADE 2 HOSE DUAL MASTER
W OUTLET TO SATELLITE - SIDE 1 - MASTER SIDE
W OUTLET TO SATELLITE - SIDE 1 OUTLET TO SATELLITE - SIDE 1 ULTRA HI MASTER-MODEL NP3 X INLET FROM TANK - SIDE 1 - MASTER SIDE
X INLET FROM TANK - SIDE 1 INLET FROM TANK - SIDE 1
A (DIMENSIONS ARE IN INCHES) Y NOT USED A
Y NOT USED INLET FROM TANK - SIDE 2
Z NOT USED
Z NOT USED INLET TO SATELLITE - SIDE 2

SCALE SH
DO NOT SCALE NO.14 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H
1" CONDUIT FOR POWER 4
4
AND 2 WIRE LOCATED 1" CONDUIT FOR POWER
40-9/16 OR 44-7/8 (4) 13/16 X 1-7/16
THIS SIDE - SEE SHEET 5 AND 2 WIRE LOCATED 40-9/16 OR 44-7/8
(UNITS LESS JUNC BOX) 36-5/8
(4) 13/16 X 1-7/16 ANCHOR BOLT SLOTS
THIS SIDE - SEE SHEET 5 36-5/8
14-3/8 20-1/4 ANCHOR BOLT SLOTS (UNITS LESS JUNC BOX) 14-3/8 20-1/4
28-3/4
28-3/4
9-1/8 9-1/4
1-9/16
SIDE B 1" CONDUIT FOR
1-9/16
SIDE B 1" CONDUIT FOR ETHERNET AND/OR ETHERNET AND/OR
INTERCOM (WHEN INTERCOM (WHEN
REQUIRED) LOCATED THIS SIDE REQUIRED) LOCATED THIS
G SEE SHEET 5 SIDE G
11-7/8 X SEE SHEET 5
11-7/8 Z Y 10-1/16
20-1/8 10-1/16
20-1/8
4 23-3/4
23-3/4 17-3/4 X W
4 OR
14-5/8 17-3/4 4-3/8 Y
4-3/8 14
24-1/16 6-15/16 11-3/4
6-15/16 12-3/8
W 7-11/16 5-3/4
5-1/2

F SIDE A F
SIDE A 8-5/16
8-5/16
16-11/16
16-11/16
20-7/16
20-7/16 3/4 NPT MALE CONDUIT OPENING FOR 1/2" CANOPY 28-1/2
OPENING FOR 1/2" CANOPY 28-1/2 FOR POWER JUNC BOX LIGHT AUX JUNC BOX
LIGHT AUX JUNC BOX 3/4 NPT MALE CONDUIT
WHEN PROVIDED WHEN PROVIDED
WHEN PROVIDED FOR POWER JUNC BOX
WHEN PROVIDED

POWER JUNC BOX


E E
WHEN PROVIDED

POWER JUNC BOX


WHEN PROVIDED

1.5" NPT INLET FROM MASTER 1.5" NPT OUTLET TO SATELLITE


(SUPPLIED WITH UNION) (SUPPLIED WITH UNION)

CANOPY LIGHT
AUX JUNC BOX 2" NPT OUTLET TO SATELLITE
D WHEN PROVIDED (SUPPLIED WITH UNION) CANOPY LIGHT D
AUX JUNC BOX
WHEN PROVIDED

W W
10 Z Y X 10-3/16 10 Y X 10-3/16
6-15/16 6-15/16
5-1/8 5-1/8
C C

2" NPT INLET FROM TANK 6

2" NPT INLET FROM TANK 6

SIDE A OF UNIT SIDE A OF UNIT


PRIMARY ELECTRICAL SERVICE SIDE PRIMARY ELECTRICAL SERVICE SIDE
GEN 1 GEN 2
B
PRODUCTION: JUNE 2002 TO PRODUCTION: FEBRUARY 2009 TO B
JANUARY 2009 DECEMBER 2012
STANDARD FOOTPRINT
ALTERNATE FOOTPRINT
POSITION MASTER/SATELLITE COMBO
NOTE:NOT IN CURRENT PRODUCTION
W OUTLET TO SATELLITE - SIDE 1 - MASTER SIDE POSITION MASTER/SATELLITE COMBO
X INLET FROM TANK - SIDE 1 - MASTER SIDE W OUTLET TO SATELLITE - SIDE 1 - MASTER SIDE
Y INLET FROM MASTER - SIDE 2 SATELLITE SIDE X INLET FROM TANK - SIDE 1 - MASTER SIDE
Y INLET FROM MASTER - SIDE 2 - SATELLITE SIDE
A
Z NOT USED ULTRA HI COMBO-MODEL NP4 Z NOT USED A

(DIMENSIONS ARE IN INCHES)

SCALE SH
DO NOT SCALE NO.15 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

H H
4

1" CONDUIT FOR POWER 40-9/16 OR 44-7/8


AND 2 WIRE LOCATED 36-5/8
THIS SIDE - SEE SHEET 5 28-3/4
(UNITS LESS JUNC BOX) 14-3/8
8-5/16
9-1/8 20-1/4

SIDE B
G G

11-7/8
Y
20-1/8 10-1/16

23-3/4 17-3/4
4 OR
4-3/8
24-1/16 12-3/8
6-15/16
X
7-11/16

F SIDE A F
1-9/16

16-11/16 (4) 13/16 X 1-7/16


OPENING FOR 1/2" CANOPY ANCHOR BOLT SLOTS
20-7/16
LIGHT AUX JUNC BOX
WHEN PROVIDED 3/4 NPT MALE CONDUIT
FOR POWER JUNC BOX
WHEN PROVIDED

E E

POWER JUNC BOX


WHEN PROVIDED

2" NPT INLETS FROM MASTERS


(SUPPLIED WITH UNION, STANDARD)
(OPTIONAL W/STRAINER ASSEMBLY)
D D
CANOPY LIGHT
AUX JUNC BOX
WHEN PROVIDED

10
Y X 10-3/16
6-15/16
C C

SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE
NOTE:NOT IN CURRENT PRODUCTION
GEN 1 & 2
GEN 1 PRODUCTION: JUNE 2002 TO JANUARY 2009
GEN 2 PRODUCTION: FEBRUARY 2009 TO DECEMBER 2012
B B

POSITION SATELLITE
W NOT USED
X INLET FROM MASTER - SIDE 1
Y INLET FROM MASTER - SIDE 2
Z NOT USED

A
ULTRA HI SATELLITE-MODEL NP5 A
(DIMENSIONS ARE IN INCHES)

SCALE SH
DO NOT SCALE NO.16 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

5
1" CONDUIT FOR
53-1/16 OR 57-3/8
1" CONDUIT FOR ETHERNET AND/OR 5
ETHERNET AND/OR
5
INTERCOM (WHEN 53-1/16 OR 57-3/8
INTERCOM (WHEN
53-1/16 OR 57-3/8
REQUIRED) LOCATED THIS SIDE REQUIRED) LOCATED
5
H 1" CONDUIT
4
SEE SHEET 5 THIS SIDE H
40-9/16 OR 44-7/8 53-1/16 OR 57-3/8 SEE SHEET 5
FOR POWER
4
AND 2 WIRE DEF CABINET
36-5/8 40-9/16 OR 44-7/8
LOCATED RIGHT HAND CONFIGURATION
THIS SIDE - 28-3/4
36-5/8 DEF CABINET
SEE SHEET 5 1" CONDUIT FOR POWER 28-3/4 RIGHT HAND
14-3/8 20-1/4
(UNITS LESS AND 2 WIRE LOCATED 14-3/8 20-1/4
CONFIGURATION
9-1/8 9-1/4
JUNC BOX) 5-1/2 1-9/16 5-1/2
THIS SIDE - SEE SHEET 5 9-1/8 9-1/4
(UNITS LESS JUNC BOX) 5-1/2 5-1/2
SIDE B 1-9/16
SIDE B
DEF 1" MALE NPT
G DEF 1" MALE NPT G
11-7/8 Z
Y 11-7/8 X
20-1/8 10-1/16 W
15-1/8 20-1/8 10-1/16
15-1/8
24-1/16 17-3/4 X 12-3/8 15-1/8 14
24-1/16
4 OR 4-3/8 17-3/4
23-3/4 6-15/16
4 OR 4-3/8 Y 15-1/8
14-5/8 23-3/4 6-15/16
11-3/4
W 7-11/16
5-3/4

F 5-1/2 F
SIDE A 8-5/16 SIDE A
20-11/16 8-5/16
DEF 1" MALE NPT
16-11/16 (4) 13/16 X 1-7/16 16-11/16 (4) 13/16 X
28-1/2 ANCHOR BOLT SLOTS 1-7/16
DEF 1" MALE NPT 20-11/16 20-7/16
ANCHOR BOLT
DEF CABINET 20-7/16 3/4 NPT MALE
LEFT HAND CONFIGURATION CONDUIT 28-1/2 SLOTS
49-7/16 DEF CABINET
FOR POWER LEFT HAND CONFIGURATION
JUNC BOX 49-7/16
OPENING FOR 1/2" CANOPY
LIGHT AUX JUNC BOX WHEN PROVIDED 3/4 NPT MALE CONDUIT
OPENING FOR 1/2" CANOPY FOR POWER JUNC BOX
WHEN PROVIDED
E
LIGHT AUX JUNC BOX WHEN PROVIDED E
POWER JUNC BOX WHEN PROVIDED
WHEN PROVIDED POWER JUNC BOX
2" NPT INLET FROM MASTER WHEN PROVIDED 1-1/2" NPT OUTLET TO SATELLITE
(SUPPLIED WITH UNION) 2" NPT OUTLET TO SATELLITE (SUPPLIED WITH UNION)
(SUPPLIED WITH UNION)
DEF 1" MALE NPT DEF 1" MALE NPT
DEF 1" MALE NPT
DEF 1" MALE NPT

D D

CANOPY LIGHT
AUX JUNC BOX
WHEN PROVIDED

30 30
30 30

C C
W
10 Z Y X 10-3/16 W
10 Y X 10-3/16
6-15/16
5-1/8 6-15/16
5-1/8

2" NPT INLET FROM TANK 6


2" NPT INLET FROM TANK 6
CANOPY LIGHT 1-1/2" NPT INLET FROM MASTER
SIDE A OF UNIT (STRAINER ASSEMBLY) SIDE A OF UNIT
AUX JUNC BOX
WHEN PROVIDED PRIMARY ELECTRICAL SERVICE SIDE PRIMARY ELECTRICAL SERVICE SIDE
B
B
GEN 1 GEN 2
PRODUCTION: JUNE 2002 TO JANUARY 2009 NOTE:NOT IN CURRENT PRODUCTION PRODUCTION: FEBRUARY 2009 TO
DECEMBER 2012
STANDARD FOOTPRINT ALTERNATIVE FOOTPRINT

POSITION 1 GRADE 1 HOSE SINGLE MASTER 1 GRADE 2 HOSE DUAL MASTER ULTRA HI MASTER-MODEL NPA & NA4 (DEF ONLY) POSITION 1 GRADE 1 HOSE SINGLE MASTER
W OUTLET TO SATELLITE - SIDE 1 - MASTER SIDE
W OUTLET TO SATELLITE - SIDE 1 OUTLET TO SATELLITE - SIDE 1 (DIMENSIONS ARE IN INCHES)
X INLET FROM TANK - SIDE 1 - MASTER SIDE
X INLET FROM TANK - SIDE 1 INLET FROM TANK - SIDE 1
A Y NOT USED A
Y NOT USED INLET FROM TANK - SIDE 2
Z NOT USED
Z NOT USED OUTLET TO SATELLITE - SIDE 2

SCALE SH
DO NOT SCALE NO.17 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

5
5
1" CONDUIT FOR
53-1/16 OR 57-3/8 1" CONDUIT FOR 53-1/16 OR 57-3/8 ETHERNET AND/OR
5
5 ETHERNET AND/OR INTERCOM (WHEN
1" CONDUIT FOR 53-1/16 OR 57-3/8 53-1/16 OR 57-3/8
H
INTERCOM (WHEN REQUIRED) LOCATED H
POWER 4 REQUIRED) LOCATED 4 THIS SIDE
AND 2 WIRE LOCATED 44-7/8 OR 40-9/16 THIS SIDE 1" CONDUIT FOR POWER 44-7/8 OR 40-9/16 SEE SHEET 5
THIS SIDE - SEE 14-3/8 SEE SHEET 5 AND 2 WIRE LOCATED 14-3/8
SHEET 5 THIS SIDE - SEE SHEET 5 36-5/8
DEF CABINET
36-5/8
(UNITS LESS JUNC (UNITS LESS JUNC BOX) RIGHT HAND
28-3/4 5-1/2 28-3/4
BOX) CONFIGURATION
16-11/16 20-1/4 DEF CABINET 16-11/16 20-1/4
5-1/2 9-1/8 9-1/4 RIGHT HAND CONFIGURATION 5-1/2 1-9/16 5-1/2
SIDE B
1-9/16 DEF 1" MALE NPT
DEF 1" MALE NPT
SIDE B
G X G
11-7/8
10-1/16
11-7/8 20-1/8
10-1/16 Y 15-1/8
20-1/8 15-1/8 24-1/16 17-3/4 14
4
OR W
24-1/16 15-1/8 15-1/8
23-3/4 6-15/16
4 OR 17-3/4 4-3/8 11-3/4
23-3/4
6-15/16 12-3/8
5-3/4
X W 7-11/16

F F
5-1/2
SIDE A
20-11/16 23-5/8
20-11/16 20-7/16 SIDE A DEF 1" MALE NPT 28-1/2
DEF 1" MALE NPT 28-1/2 20-7/16
8-5/16 49-7/16
DEF CABINET 49-7/16
LEFT HAND CONFIGURATION (4) 13/16 X 1-7/16
(4) 13/16 X 1-7/16 DEF CABINET ANCHOR BOLT SLOTS
3/4 NPT MALE LEFT HAND CONFIGURATION
ANCHOR BOLT SLOTS
CONDUIT
OPENING FOR 1/2" CANOPY FOR POWER JUNC BOX 3/4 NPT MALE CONDUIT
E LIGHT AUX JUNC BOX WHEN PROVIDED OPENING FOR 1/2" CANOPY FOR POWER JUNC BOX E
WHEN PROVIDED LIGHT AUX JUNC BOX WHEN PROVIDED
WHEN PROVIDED

POWER JUNC BOX 1-1/2" NPT OUTLET TO SATELLITE


2" NPT INLET FROM MASTER POWER JUNC BOX 2" NPT OUTLET TO SATELLITE
WHEN PROVIDED (SUPPLIED WITH UNION)
(SUPPLIED WITH UNION) WHEN PROVIDED (SUPPLIED WITH UNION)
DEF 1" MALE NPT
DEF 1" MALE NPT DEF 1" MALE NPT
DEF 1" MALE NPT

D D

CANOPY LIGHT
AUX JUNC BOX
WHEN PROVIDED

30 30
C C
30 30

X W
Y 10 10-3/16
X W 5-1/8
10 10-3/16
6-15/16
5-1/8

CANOPY LIGHT SIDE A OF UNIT 2" NPT INLET FROM TANK 6


B SIDE A OF UNIT 2" NPT INLET FROM TANK 6 B
AUX JUNC BOX PRIMARY ELECTRICAL SERVICE SIDE
WHEN PROVIDED PRIMARY ELECTRICAL SERVICE SIDE
GEN 1 GEN 2
NOTE:NOT IN CURRENT PRODUCTION PRODUCTION: FEBRUARY 2009 TO
PRODUCTION: JUNE 2002 TO JANUARY 2009
DECEMBER 2012
STANDARD FOOTPRINT ALTERNATIVE FOOTPRINT
POSITION MASTER/SATELLITE COMBO ULTRA HI COMBO-MODEL NPB POSITION MASTER/SATELLITE COMBO
W OUTLET TO SATELLITE - SIDE 1 - MASTER SIDE
(DIMENSIONS ARE IN INCHES) W OUTLET TO SATELLITE - SIDE 1 - MASTER SIDE
A X INLET FROM TANK - SIDE 1 - MASTER SIDE A
X INLET FROM TANK - SIDE 1 - MASTER SIDE
Y INLET FROM MASTER - SIDE 2 SATELLITE SIDE
Y INLET FROM MASTER - SIDE 2 - SATELLITE SIDE
Z NOT USED
Z NOT USED
SCALE SH
DO NOT SCALE NO.18 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

VAPOR RECOVERY
HEALY VAPOR PUMP 4
CONTAINMENT SUMP LOCATION
LOCATION WHEN 40-9/16 OR 44-7/8
PROVIDED 13-3/4
H 1" CONDUIT FOR POWER 9-1/8 20-1/4 CALL W/SPKR J-BOX 3/4" CONDUIT H
AND 2 WIRE LOCATED 15-1/8 16-1/4 OPENING WHEN PROVIDED
THIS SIDE - SEE SHEET 5 6-3/16 9-1/2
(UNITS LESS JUNC BOX) 2-5/8 9-1/4
SIDE B
1" NPT FEMALE FITTING
FOR VAPOR RECOVERY

2-11/16

11-7/8
10-1/16
G G
20-1/8
5-5/8
X W 4-7/8
Z
23-3/4
4 OR
24-1/16 17-3/4
7-11/16
Y
2-7/16

1" CONDUIT FOR ETHERNET OR


F IFSF AND/OR INTERCOM (WHEN F
REQUIRED) LOCATED THIS SIDE
SEE SHEET 5
SIDE A (4) 13/16 X 1-7/16
4-3/4 ANCHOR BOLT SLOTS
OPENING FOR 1/2" CANOPY 9 9-3/4 9
28-3/4 OPENING FOR 1"
LIGHT AUX JUNC BOX
JUNC BOX CONDUIT
WHEN PROVIDED 36-5/8
WHEN PROVIDED

E E

D D

CALL W/SPKR J-BOX


WHEN PROVIDED

1" NPT VAPOR INLETS MODEL# DISPENSER MODELS


1-1/2 NPT COUPLING
PRODUCT INLETS W NA0 1 GRADE 2 HOSE MPD
WHEN PROVIDED
C W & X NA1 2 GRADE 4 HOSE MPD C
NG4 2 GRADE SINGLE HOSE MPD
NN1/NN2/NN3 X+0 SELECTABLE BLENDER
NJ0 3 GR MULTI HOSE BLENDER
CANOPY LIGHT W,X & Y NA2 3 GRADE 6 HOSE MPD
AUX JUNC BOX
WHEN PROVIDED
30-9/16 NG0 3 GRADE SINGLE HOSE MPD
NL0/NL1/NL2 X+1 SELECTABLE BLENDER 2
NJ2 3+1 MULTI HOSE BLENDER
W,X,Y & Z NA3 4 GRADE 8 HOSE MPD 3
B 11-7/16 NG1 3+1 SINGLE HOSE MPD B

10 10-5/8 13-1/8

4-1/4 DISPENSERS WITH ECOMETER


7 (DIMENSIONS ARE IN INCHES)
POWER JUNC BOX HEALY VAPOR PUMP
WHEN PROVIDED WHEN PROVIDED
A A
SIDE A OF UNIT
PRIMARY ELECTRICAL SERVICE SIDE
SCALE SH
DO NOT SCALE NO.19 OF 19
ECO SYM REV
1001363 NO. M01432 AA
PRO/E
7 6 5 4 3 2 1