You are on page 1of 6

Product 

data 

CTS-800
——Palm‐size veterinary 
ultrasound

Appearance Probe Mode 

- Palm size design  - L7FVC Linear rectal probe 
- 7‐inch WVGA LCD monitor  - L5FVC Linear rectal probe 
- Visual Angle:  - C3FC Convex probe 
- Left and right side: 65°    - C5FC Micro‐convex probe 
- L1FC Linear probe (back fat) 
- Resolution : 800 × 480 
- One active probe connectors 
- Built‐in lithium battery 
Technology 
- Working hour: 160±20 min 
- Charging time: 5±0.5 hour  Applications 
- Environmental rating: 
- Bovine 
‚ IP 54 (main unit) 
- Equine 
‚ IP 67(probe head) 
- Ovine 
- Porcine 
Probe 
Highlight 
Transducer Types 
- Gravity Sensor 
- Electronic convex probe 
- Grid for estimation 
- Electronic micro convex probe 
- Battery 
- Electronic linear probe 
- Video glasses (Optional) 
- Electronic trans rectal probe 
Product data 
- Edge enhancement: 0~4 
Display mode  - Smooth: 0~3 
- Persistence: 0~7 
- B mode  - Pseudo color: 0~7 
- 2B mode  - Grayscale: 0~23 
- B/M mode  - Power: 0~100% 
- M mode 
- Zoom B mode  M mode 

Zoom  - Gain:0~100 
- Sweep speed: 4 steps 
- Real time zooming  - Maps: 0~23 
- 3 Steps: ×2.0, ×3.0, ×4.0  - Pseudo color: 0~7 
- Selectable zooming position 
- Zoom frozen  Measurement & Calculation 
- 3 Steps: ×2.0, ×3.0, ×4.0 

Measurement 
Focus 
2D mode (General) 
- Continuous dynamic focus 
- Dynamic apodization  - Distance 
- Dynamic aperture  - Trace (area) 
- 1~4 selectable transmit focus  - Ellipse (area) 
- Acoustic lens focus  - Biplane (volume) 
- Ellipse (volume) 
Memory  - Simpson (volume) 
- Sphere (volume) 
- Cine‐memory  - Angle (general) 
‚ B‐mode (max.256 frames)  - Area ratio (trace) 
‚ M‐mode (max.2550 seconds)  - Area ratio (ellipse) 
- More than 16 frames instant image  - % area reduction (trace) 
storage  - % area reduction (ellipse) 
- More than 32 BMP/300 JPG Image  - % dima.reduction 
storage  - Histogram 
- Memory card 100M  - LDW volume (3 lines) 

Imaging Processing  M mode 

- Time 
2D mode 
- Multiple distance 
- Gain: 0~100  - Heart rate 
- Depth: 1.6~24.4 cm  - Slope 
- Frequency: 5 steps 
- Dynamic range adjustable: 36~180dB  Calculation 
Product data 
‚ Length Left Kidney 
Abdomen 
‚ Anteroposterior Left Kidney 
- Liver  ‚ Transverse Left Kidney 
‚ Long Left Lobe  ‚ Left Renal Artery 
‚ Anteroposterior Left Lobe  ‚ Length Right Kidney 
‚ Angle Left Lobe  ‚ Anteroposterior Right Kidney 
‚ Obli R Lobe  ‚ Transverse Right Kidney 
‚ Anteroposterior Right Lobe  ‚ Right Renal Artery 
‚ Angle Right Lobe 
‚ Portal Vein  - Ureter 
‚ IVC (Inferior Vena Cava)  ‚ Left 
‚ SMA (Superior Mesenteric 
‚ Right 
Artery) 
‚ CELA (Celiac trunk) 
‚ AO (aortaventralis)  - Bladder 
‚ Length 
- Spleen  ‚ Anteroposterior 
‚ Length  ‚ Transverse 
‚ Anteroposterior 
‚ Spleen artery  Obstetrics 
‚ Spleen vein 
- GSD (gestation sac diameter) 
- Gallbladder  - CRL (crown‐rump length) 
‚ Length  - BPD (biparietal diameter) 
‚ Anteroposterior 
- HD (head diameter) 
‚ Transverse 
- TD (transverse trunk diameter) 
‚ Wall 
‚ CBD (Common bile duct)  - BD (Body diameter) 
‚ LHD (Left hepatic duct)  - Growth charts 
‚ RHD (Right hepatic duct) 
Reproductive M 
- Pancreas 
‚ Head  - Prostate 
‚ Body  ‚ Volumen 
‚ Tail  ‚ PSAD (Prostate specific antigen 
‚ MPD(Main pancreatic duct)  Density) 

- AO  - Testes 
‚ % Dima.reduction  ‚ Long Left Testis 
‚ % Area reduction  ‚ Anteroposterior Left T Testis 
‚ Transverse Left T Testis 
Urology  ‚ Long Left Epididymis 
‚ Anteroposterior Left Epididymis 
- Kidney  ‚ Long Right Testis 
Product data 
‚ Anteroposterior Right Testis  wall diastolic) 
‚ Transverse Right Testis  - RVd (Right ventricle diastolic period) 
‚ Long Right Epididymis  - RVOT (Right ventricular outflow 
‚ Anteroposterior Right Epididymis  tract) 
- AO (Aorta) 
Reproductive F  - LA (Left atrium) 
- IVSd (Inter‐ventricular septum in 
- Uterus  diastolic period) 
‚ Length  - LVd (Left ventricle in diastolic period) 
- LVPWd (Diameter of left ventricle 
‚ Anteroposterior 
posterior wall in diastolic period) 
‚ Transverse 
- RVAWs (Right ventricular anterior 
‚ Endometrium 
wall systolic period) 
- RVs (Right ventricular systolic period) 
- Cervix  - IVSs (Inter‐ventricular septum in 
‚ Length  systolic period) 
‚ Anteroposterior  - LVPWs (Diameter of left ventricle 
‚ Transverse  posterior wall in systolic period) 
- RA (right ventricular) 
- Ovary  - IVC (Inferior vena cava) 
‚ Length Left  - PA (Great artery short axis view) 
‚ Anteroposterior Left 
‚ Transverse Left 
Physical Features 
‚ Length Right 
‚ Anteroposterior Right  Connectivity 
‚ Transverse Right  - Video out port 
- 1 USB port 
- Follicle  - 1 RJ‐45 
‚ Volume 1  - AC power input port 
‚ Volume 2 
‚ Volume 3  Dimension 
‚ Volume 4 
- Gross dimension: 
‚ Volume 5 
- 440 mm (H) X 340 mm (W) X 185 mm 
‚ Volume 6 
(D) 
‚ Volume 7  - Net dimension: 
‚ Volume 8  - 225 mm (H) X 128 mm (W) X 45 mm 
‚ Volume 9  (D) 
‚ Volume 10 
Weight 
Cardiology   
- Gross weight : 7kg (2 probes and 
- RVAWd (Right ventricular anterior  carry case)   
Product data 
- Net weight : 0.8kg  - Video glasses (CLIPon600) 
- Carry case   
Power Requirements 

- Voltage: AC 100V to 240V±10% 
- Frequency: 50Hz±1Hz; 60Hz±1Hz 
- Rated Power: 250VA 

Operation Conditions 

- Ambient temperature: 0℃ to +40℃ 
- Relative humidity: 30% to 85% 
- Atmospheric Pressure: 700hPa to 
1060hPa 

Stored Conditions 

- Ambient temperature: ‐20℃ to 
+60℃ 
- Relative humidity: 15% to 93% 
- Atmospheric Pressure: 500hPa ~ 
1060hPa 

Software & Accessories   

Standard Accessories 
- One Lithium battery 
- Power adapter 
- Operation manual 
- BNC cable 
- USB cable 
- Power Cable 
- Printer control cable 
- Cable connection for car cigarette 
lighter 
- Belt 
- Sunshade 
- Cover 

Optional Accessories   

- B/W or color Video printer 
- LaserJet printer 
- DICOM 3.0 software 
- Optional battery   
Product data 
Probe 

Model  Transmit  Max.  View  Array  Biopsy 


Applications 
mode  frequency (MHz) depth  field  radius  guide 
Linear rectal probe 
Bovine  B mode: 
L5FVC  150mm  64mm  Invalid 
Equine  4.0/4.7/5.0/5.5/6.2
Bovine  B mode: 
L7FVC  134mm  50mm  Invalid 
Equine  6.5/7.1/7.5/8.3/9.0
Convex probe 
Bovine 
Equine  B mode: 
C3FC  244mm  69°  R60  Invalid 
Ovine  2.5/3.0/3.5/4.0/5.0
Porcine 
Micro‐convex probe 
Ovine  B mode: 
C5FC  150mm  72°  R20  Invalid 
Porcine  3.5/4.0/5.0/6.5/7.1
Linear probe 
Porcine  B mode: 
L1FC  244mm  150mm Invalid 
(back fat)  2.5/3.0/3.5/4.0/5.0

You might also like