A rectangular shaped spread footing supports an interior column with a factored load of Pf = 1100 kN. The columns dimensions
are 600 mm by 400 mm. Assuming that the soil stresses under the footing are under allowable stress limits.
1a) Check if the thickness of the footing satisfies one-way and two-way shear requirements of TS500-2000.
1b) Design the flexural reinforcement according to TS500-2000 and show reinforcement layout on plan and sections.
Pf = 1100 kN
all dimensions in mm
h= 500 mm.
1300
400
600
2100
FURKAN BESEN
2a) Calculate the natural period of the single-story RC structure given below and the earthquake load VtE , according to the
Turkish EQ Code 2018 . Use the method given in Clause 4.7.3.1 of TBEC2018 when calculating the natural period.
G= 2300 kN
Q= 145 kN n= 0.6
2b) Calculate the shear force in each column using Muto's Method and assuming uncracked stiffness for columns
and beams, if the EQ load calculated in (2a) is acting as shown below.
2c) Draw the bending moment (MEQ) and shear force diagrams (VEQ) of frame A shown below under the earthquake loading
calculated in (2a). Assume yo= 0.55 for all columns.
A A
EQ
EQ BM 300 x 660 DP
2200
350 x 300 300 x 350
5500
all dimensions in mm.
Section A