You are on page 1of 7
* BBm JSPM DDZ i FF ih EK iE JW BE 5 Type DDZ Drill Pipe Elevator Manual 2020 FR) xe AMR AR A Jiangsu Petroleum Machinery Co., Ltd HALLCADD)s TLASILA EOC ARM 23 No.23 Kast Sandun Road, Zhouzhuang Town, Jiangyin Cty, Jlangsu Province, China SHAK (Tel): 86-510-86978701 AEH (Fax): 86-510-86978700 fete CP.C): 214423, hutp:// wwwjspmgroup.com E-mail: sales@jspmgroup.com Escaneado con CamScanner ly 2 3y S 5. 6. 7 8, A —-:3¢ Contents ER General, EXLARBA Main technical parameters: 313M XM Type formation and its representative meaning... Sak (SWZ) Structure(See drawing). AEFATTIE Usage. BSiRHEH Deduction of wear and tear... 4E5-4RFE Maintenance... YEH Attention... Escaneado con CamScanner 1, $B General DDZ. ‘SR FER ELA MEHR! CH FINI QE. BTS GAT, AP RITE AUER DL WLAIEBOR. PARAK API Spec 8C (HiIFAURIMLTH OLA ALIED, 2 2 (EDL Lt FORAAUBUHE, STR STT 15 EAR. The DDZ type drill pipe elevator is a wellhead tool in the drilling and repairing of cSke AEE Rite EMEA Het, Seid. oil or gas well. It is easy and safe for handling 18-dregrees drill pipe, and of great advantage to prolong life of self-seal head of blowout presenter. It is designed according to API Spec 8C for Drilling and Production Hoisting Equipment. It was design verification tested at more than two times the max. test load, and underwent ex-factory test at one and a half times the rated load. lata] my . Etkée3 BODY —LEFT » MFASESE LATCH SPRING 3, RELFIEMIELATCH LOCK SPRING 4, {IF ALATCH LOCK 5, dbthi{ BODY — RIGHT 6, 84144 HINGE PIN 7, AILATCH Escaneado con CamScanner 2, EEEABAR Main technical parameters: Be 189TH TABLE 1_SPECIFICATIONS.-- 18° TYPE SERIES ELEVATORS SPA NOAA AUNT 1s EAE Suitable for tol Joint and Drill Pipe 18° Type Elevator Bores BARI, “FAL dd Elev ‘SeHTA ANS End oto Marking | 83189 Too! Joint FADRBRBI Top Bore | 5 Designation Reference Drill pipe Size and style re (Al weights and Grades) mm 2.3/8EU NC26(2.3/81F) 2.3/8EU 107.95 6747 2.7/8EU NC31(2.7/8IF) 2.7/8EU 120.65 83.34 NC38G.172 3.12EU ‘ a) 3.12EU 139.70 100.81 NC40(4IF) 4 NC40(4FH) 4 165.10 108.74 4EU 4EU NCA6(4IF) amu 4antu 4121EU mas | 12144 4.1/21EU coe : {rehia 4.nEU osoevary fate “NS me J Sue’ WV 180.98 13335 SIEU 5.1/2FH SIEU S.12IEU S.12FH 5.172IEU 20002 | 14768 5.7/81EU 5.7/8FH S.7/81EU 203 159.15 6.5/81EU 6.5/8FH 6.5/81BU 25 179 Rl BHAT RAR AD TABLE 2 RATED CAPACITIES--18° TYPE SERIES ELEVATORS meen wx | 9m [ans [13s [2250 3180 ary Rated Capacities | tons | 100 | 12s | 150 250 ‘380 a APRA Suitable for in | 23m8 | 237012 2.3/8-8.02 2.985.718 46518 Drill Pipe Size(O.D.) BAORARTCH | in 1342.94 2AM 1 2 Min. and Max. Dia. M4312 | 3.1r65/8 weld less Links a ees sris—se9 | 57.8889 | sao-n06 2 Escaneado con CamScanner 3. WRN Type formation and its representative meaning pb ZoO/ 0 95 ANA Ctons) Rated Capacities “FALE (mm) Bottom Bore I. D. HAR 18°HLG GA 18° Taper Shoulder AORN FFAAA A Center-Latch Elevator 4. St) (BILGE) Structure(See drawing) DDZ AERA ERIKA. EAT, OU, GREE RTT HPAL. EGE. AUER OTE, MIA. BMS R— Hi, GLARE TIE ROTTER FH RTT The DDZ type drill pipe elevator is made up of body-left and right, latch, latch lock, hinge pin and springs. The ears of body-left and right can be hung by Links. The body left and right are latched together by the latch. The body-left and right can be sure not opened by the latch lock when handle drill pipe. DDZ WE RETARASA AREAS SHON, ET REE Fate. OTHE. cg = All of important parts for the bodies acca from high-strength alloy steel. Be sure safety to handle. J Ss PM 5. (ATT Usage (D, DDZ RHR REBT AE (EDA —E) PRE, REE BRR FI. ), BEM P RS OER. RUC AHEF20C. O. GAMMA, RELAIS, QURIRLATTAR, SE (As AMAL Aa TCAD EO AE ATE, PRE. OR Fein Si AIA « ©), BE FE, ASAI TOURER SIEM, ROMEO BSAA LL LADY) SLR HT TTT BR A MAR TT AB TT 6 ©). PRELEEZEANA At DDZ HAT AR ATHEDLSD, $5 SNL OH AT FLA RLM. BARANYA HI 1.Smm UAE BEALE ASL. (1)The DDZ type elevator is suitable to single elevator lifting and dropping pipes in the work of well drilling. (Overload is strictly forbidden. The elevator should be operated at not less 3 Escaneado con CamScanner than -20C. @)Before use, please check the opening and closing flexibility of the latch and the latch lock, and their ability whether are reliable. Twisting foree of the spring should be proper. After a period of use or the maintenance of the elevator, the bodies and latch should be strictly examined. It is not allowed to use any more in case of any defects such as cracks and deformation, And it is not allowed to use if the latch lock can’t be blocked by the safety pin. (Before every lifting and dropping drill tools, should be check whether the hinge pin and ete. are normal or not. Check them whether excessively wear and tear and clear weaken, The surface of hinge pin and the places in contact with links should be greased. (Check and mature the cone bore of the DDZ type elevator and the surface of Grill pip joint in cooperation with the elevator. When wearing isn’t even or sunken up to more than 1.5mm. It should be repaired. Sais, — 6, ERASE Deduction of wearrandte a e-L eesevat Taper Cc] 12° 4" 16° 18° 100 90 8 70 60 50 40 30 aE AER A 9 5 NE J BY SZ} Percentage of Reduced Rated Capability (GFA, SOAP AUT AE AN AT eS HEB, GRE AMR BL, an AEG, MAR LAAT AE AE Ne DRT Hee, PTE fe TA. Escaneado con CamScanner Before use, check carefully the taper of the elevator and drill pipe joint. See whole loaded surface whether take place change. If happen, should reconsider rated capability of elevator according to above the table or deliver back our company to repair. Overload is strictly forbidden. 7. BP4RFE Maintenance D. SNME BERT. HES) AMALIE. OQ). ARES BDEE FEE ABE: O, AAG MINER AE LANG, YORI, -RMTERDT MIM, Fried A FARA. ©, SEM RRR HEME Ce. AR EABEL, OAS) EPR, iE ATR, ROSMAN AL (Fitting grease to turning round and sliding places of the elevator. | (2)Be sure do not drop the elevators from higher position. | (3)After use, clean oil dirt and mud at elevator, and coat antirust grease, and put it at dry place in house. WAfter a period of usé, remove paintrawayzformethe forced place of the bodies, the latch and ete, and underga(fiaw detlSonhibpbellthie is not allowed to use any | more in case of any defects such’as scars.or Seg M 8, JER Attention RBA MEERA PBR ARSE HAD. PRAEMESE- PH API RP SB HST LL ADHD ES FRHAE(E AVIRAPETARI, HOUR, ROT TEAT EA. WAP REAM APSR, AU PRR EL, AAR. - The elevator must not be welded and repaired " without the technical information of our corporation. In case the repairing factory conduct strict and proper maintenance and inspection in conformity with standard API RP 8B “recommended process of inspection and maintenance of the elevator”, the elevator can be welded or repaired. - When elevator grip pipe, latch lock must be in correct place to prevent it from skidding + Don't select the spare parts manufactured by other companies. Otherwise our company is not responsible for quality question. Escaneado con CamScanner

You might also like