Professional Documents
Culture Documents
Equipment
• EtherCAT/Ethernet interface
• CANopen
• Profibus DP
• USB interface for parameterisation via PC
• RS485 with 2 capture inputs
• 2 encoder interfaces
• Encoder output for Master-Slave-operation, or
• Reliable starting lockout
Functions
Ambient Conditions
Class 3K3 acc. to EN 50178
Ambient temperature during operation with rated load 5 °C .. 40 °C
Degree of humidity (non-condensing) 5 - 85 (% rel. humidity)
Cooling In a closed cabinet, sufficient circulating air movement must be provided
Installation altitude max. 1000 m above mean sea level without power reduction
Mounting position The technical data refer to a vertical mounting position
Protection class IP20
Applied standards for CE EMC acc. to EN61800-3, safety acc. to EN61800-5-1
Applied standards for UL UL508C
Basic Functions
• Digital current, speed, and position control with position, speed
and torque limiting
• Digital filter functions effective on resonant loads
• Parameterisable velocity profiles with jerk limiting
• Short-circuit, voltage, temperature, encoder, tracking error, and
I2xt monitoring
• Parameterisation via EtherCAT, Ethernet, CANopen, USB, RS232,
RS485 or Profibus DP
• Scalable analogue inputs for any setpoint
• Scalable analogue monitor outputs for any actual value
• Intelligent control of a holding brake with automatic voltage
reduction
• Limit switch and reference sensor evaluation, various homing
modes
• Enabling of output stage and reset of fault conditions via digital
input
• Readiness for operation message via digital output
• Status indication and setting of field bus node address and baud
rate on the front via seven-segment display and 2 keys
Master/slave positioning
• Parameterisable electric gearbox
• Master position via encoder signals or CANopen
Joystick operation
• Parameterisable joystick table for speed or position with
256 entries
• Joystick connection to +/-10 V analogue input
X4
DC link voltage
ballast resistor
X22
Options: encoder emulation,
X8 Profibus DP, Ethernet
Restart lock
X21
CAN
X3 X14
Analogue inputs/outputs USB
X13
RS485/RS232/Capture
X2
Digital inputs
X12
X1 Encoder B
Digital inputs/outputs
X11
Encoder A
X5
Motor connector
X6
Power connector
X7
Motor brake
Accessories
Complementary parts
DPZ11 Shield set with 1 side part, 2 cable clamps and mounting elements
DPK10 Connector set ECOVARIO® 214/414
Ballast resistors
DPR10-100 Ballast resistor 10 Ω/100 W (250 W cooled)
DPR10-200 Ballast resistor 10 Ω/200 W (500 W cooled)
Power Supplies
SV24 Single-phase power supply unit 24 VDC / 5 A
SV24/85/105 Single-phase power supply unit 24 VDC / 4 A, 85 or 105 VAC / 650 VA
TE500-85/105 Single-phase transformer 85/105 VAC / 500 VA
TD1000-85/105 Three-phase transformer 85/105 VAC / 1000 VA
TD1500-85/105 Three-phase transformer 85/105 VAC / 1500 VA
For details concerning the power supplies please refer to data sheet 12-2.
Connections / ECOVARIO ® 214
ECOVARIO
®
Machine signals
X13
CAP1+ RS422
quick event capture
CAP1-
X12 CAP2+ RS422
15 CAP2-
Encoder B
5
RS485
altern.RS232 PC
or
X11 X14 4 Parametrizing
USB interfaces
9
Encoder A
X21 4
CAN CAN
X5
A/U
X22
A/V 8 Ethernet/EtherCAT
Ethernet/EtherCAT
2 or PROFIBUS DP
B/W or PROFIBUS or Encoder interpreter
B or ENCODER OUT
X8 ASI+
ASI- Restart lock
ASO1
Reply restart lock
ASO2
X7
X3
+15V
+BRAKE
AGND
-BRAKE
-15V
GND
AIN1+
Analog demand value 1
AIN1-
F B1*)
AGND
X4
RB AIN2+
Analog demand value 2
DC+
FB2 *) +R/+L AIN2-
-R AGND
DC- -L MON1 Monitor 1
PE PE MON2 Monitor 2
AGND
DC supply or R brake
X6
10AT X2
L3/N GND GND
10AT L2 CWI Positive limit switch
10AT L1/L CCWI Negative limit switch
PE HOME Homing
DIN6 Digital input
GND GND
X1
ENABLE
READY
RESET
OUT2
OUT1
+24V
GND
GND
L1
24V DC
L2
Digital output 1
L3 3x
Digital output 2
400V AC
Ready
Reset
N Enable
PE GND
www.jat-gmbh.de Jenaer Antriebstechnik GmbH • Buchaer Str. 1 • D-07745 Jena • Tel.: +49 (0) 36 41 / 6 33 76- 55 • Fax: +49 (0) 36 41 / 6 33 76-26