You are on page 1of 1

REINFORCED CONCRETE RETAINING WALL DETAILS

0
0

0 0 A B
12mmØ Longitudinal Rebar(Grade 40) 16mmØ bar (Grade 40)
spaced @ 200mm O.C. spaced @ 280mm O.C.
20mmØ bar (Grade 40)
B spaced @ 280mm O.C.
A

2
2
(max.)
3000
WEEP HOLE PIPES

H
=
(PVC 75mmØ)

GRAVEL FILTER
MATERIAL

88
16mmØ Longitudinal Rebar(Grade 40)

°
86
0 1
spaced @ 200mm O.C.
0
0
t=0

0
D 0
C 1

16mmØ bar (Grade 40)


C spaced @ 280mm O.C.

0
100mm. THK. LEAN CONCRETE

REINFORCED CONCRETE RETAINING WALL DETAIL


SCALE 1:50
16mmØ bar (Grade 40)
16mmØ bar (Grade 40) spaced @ 280mm O.C. 0

0
spaced @ 280mm O.C.D 1
E

0
0

0
GENERAL NOTES :

1. MATERIALS AND WORKMANSHIP SHALL COMPLY WITH "STANDARD SPECIFICATIONS FOR HIGHWAYS AND BRIDGES, REVISED 2013.
2. ALL DIMENSIONS ARE IN METERS UNLESS INDICATED OTHERWISE.
THE REINFORCED CONCRETE RETAINING WALL SHALL BE CONSTRUCTED ON A LAYER OF LEAN CONCRETE 100mm MINIMUM THICKNESS.
3. THE MINIMUM CONCRETE COVER FOR CONCRETE PERMANENTLY IN CONTACT WITH THE EARTH IS 75mm.
4. THE MINIMUM CONCRETE COVER FOR CONCRETE EXPOSED TO WEATHER IS 40mm - 50mm.

CONCRETE:
LATERAL BARS BENDING DIAGRAM
SCALE 1:50
ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSION STRENGTH IN 28 DAYS OF f ' c = 20.7 MPa (3000psi).

STEEL REINFORCEMENT:
ALL REINFORCING STEEL TO BE INTERMEDIATE ( GRADE 40 ) ASTM A - 615 WITH DEFORMATIONS
CONFORMING TO ASTM A - 305