You are on page 1of 1

1 2 3 4 5 8 9 10 11

1. SCOPE TABLE 1 STOOL PIPE TYPE

THIS STANDARD DRAWING APPLY TO PLATFORM FOR STATIC EQUIPMENT, SHELL OR SKIRT PAD PLATE STOOL PIPE FLANGE/END PLATE LADDER CLIP

UNLESS OTHERWISE SPECIFIED ON EACH DESIGN DRAWINGS. A387-11-2 A387-11-2 A335-P11 A387-11-2 A387-11-2
A A387-12-2 A387-12-2 A335-P12 A387-12-2 A387-12-2 A

2. USAGE OF THESE STANDARD DETAILS.


A516-60 A283-C/A516-60 A106-B A283-C A283-C/A516-60
2-1 DRAWING LIST
A516-60 (LOW TEMP) A516-60 A333-6 A516-60 0R A283-C A516-60 0R A283-C

DRAWING NUMBER DESCRIPTION A283-C A283-C A106-B A283-C A283-C

NFEF-60-43-ST-DR-TD-011 STANDARD DRAWING PLATFORMS FOR STATIC EQUIPMENT GENERAL NOTE A240-TP304L A240-TP304L A312-304 A240-TP304 A240-TP304

NFEF-60-43-ST-DR-TD-012 STANDARD DRAWING PLATFORMS FOR STATIC EQUIPMENT VERTICAL VESSEL (HOT SERVICE)

NFEF-60-43-ST-DR-TD-013 STANDARD DRAWING PLATFORMS FOR STATIC EQUIPMENT VERTICAL VESSEL (COLD SERVICE) TABLE 2 PLATE TYPE

NFEF-60-43-ST-DR-TD-014 STANDARD DRAWING PLATFORMS FOR STATIC EQUIPMENT HORIZONTAL VESSEL SHELL OR SKIRT CLEAT LADDER CLIP
NFEF-60-43-ST-DR-TD-015 STANDARD DRAWING PLATFORMS FOR STATIC EQUIPMENT OF LADDER (1/2)
A387-11-2 A387-11-2 A387-11-2
NFEF-60-43-ST-DR-TD-016 STANDARD DRAWING PLATFORMS FOR STATIC EQUIPMENT OF LADDER (2/2)
A387-12-2 A387-12-2 A387-12-2
NFEF-60-43-ST-DR-TD-017 STANDARD DRAWING PLATFORMS FOR STATIC EQUIPMENT FLOORING, HANDRAIL AND ACCESSORIES
A516-60 A283-C/A516-60 A283-C/A516-60
B B

A516-60 (LOW TEMP) A516-60 A516-60


NFEF-60-43-ST-DR-TD-005 STANDARD DETAILS FOR LADDER (2/2)
A283-C A283-C A283-C
NFEF-60-43-ST-DR-TD-001 STANDARD DRAWING GENERAL NOTE
A240-TP304L A240-TP304L A240-TP304L

5. BOLTING NOTES
2-2 REFERENCE GUIDE SYMBOLS. 5-1 HIGH STRENGTH BOLT SHALL BE BEARING TYPE.
a. SYMBOL TO GUIDE FOR STANDARD DETAILS : 5-2 BOLT HOLE DIAMETER SHALL BE AS FOLLOWS (IN MM) UNLESS OTHERWISE INDICATED IN

DESIGN DRAWINGS:
STANDARD DETAIL NO. OR SECTIONAL NOTATION.
00
C 00 NOTES. C
000
STANDARD DWG NO. TO BE REFERRED. BOLT SIZE BOLT HOLE DIAMETER

M16 18

b. SYMBOL TO GUIDE FOR INDIVIDUAL DETAILS OR SECTIONAL VIEWS WHICH ARE NOT STANDARDIZED : M20 22

M22 24
DETAIL NO. OR SECTIONAL NOTATION.
00
00 NOTES. M24 26
000
ENGINEERING DWG NO.TO BE REFERRED.
5-3 ONE HIGH STRENGTH BOLT ASSEMBLY SHALL CONSIST OF HEAVY HEX HEAD STRUCTURAL BOLT,

HEAVY HEX NUT, AND HARDENED WASHER.


3. DIMENSIONS.
5-4 ONE HARDENED WASHER SHALL BE INSTALLED AT THE NUT SIDE.
ALL DIMENSIONS ARE IN MILLIMETER, UNLESS OTHERWISE INDICATED IN ENGINEERING DRAWINGS.
D 6. WELDING D

4. MATERIAL SPECIFICATIONS UNLESS OTHERWISE SPECIFIED, ALL WELDING DETAILS SHALL BE IN ACCORDANCE WITH

UNLESS OTHERWISE NOTED, ALL MATERIALS SHALL CONFORM TO THE FOLLOWING OR APPROVED EQUAL. NFEF-60-43-ST-DR-TD-001.

a. STRUCTURAL STEEL : BS EN 10025:GRADE S275 OR EQUIVALENT


7. OTHERS
b. STOOL PIPE : AS SPECIFIED BELOW
7-1 ALL PLATFORM COMPONENTS AND FASTENERS SHALL BE HOT DIPPED GALVANIZED AS PER
c. HIGH STRENGTH BOLT(H.S.BOLT) : ASTM A325M TYPE-1
PROJECT SPECIFICATION.
d. ORDINARY STRENGTH BOLT(O.S.BOLT) : ASTM A307M GRADE A

e. STAINLESS STEEL BOLT/NUTS EXCEPT FOR PLATFORM OF CRYOGENIC HEAT EXCHANGER AND
7-2 WHERE CONNECTING DISSIMILAR METALS WILL CAUSE GALVANIC CORROSION, A SUITABLE INSULATION
SUB COOLING HEAT EXCHANGER.
MATERIALS (P.T.F.E. POLYTETRAFLUOROETHYLENE) SHALL BE PROVIDED BETWEEN THE METALS.
BOLTS : ASTM A193M GRADE B8 (TP.304)

NUTS : ASTM A194M GRADE 8M (TP.316)


E E
WASHER : TP 304 t=3.0mm 7-3 THERMAL EXPANSION/CONTRACTION MOVEMENT DUE TO SERVICE TEMPERATURE

f. GRATING : BS EN 10025:GRADE S275 OR EQUIVALENT SHALL BE CONSIDERED TO PLATFORM DESIGN.

g. ELECTRODES : AWS A5.1 E70XX OR EQUIVALENT

h. SUPPORT CLIP : PAD PLATE, STOOL PLATE, FLANGE AND END PLATE 7-4 FOR SAFETY PURPOSE, THE FOLLOWING GALVANIZED STEEL COMPONENTS SHALL BE PAINTED AT FIELD

MATERIAL SHALL BE IN ACCORDANCE WITH TABLE 1 & 2. IN SAFETY YELLOW (BS 4800 : 10-E-53, MUNSELL 6.25Y 8.5/13 OR RAL:1018) WITH BLACK

(BS 4800 : 00-E-53, MUNSELL N 1.5 OR RAL:9004) IN ACCORDANCE WITH SYSTEM NO. 14 IN TABLE 2
FURTHERMORE, IN CASE THAT IMPACT TEST IS REQUIRED
OF NFEF-60-00-SP-TS-NA-006.
ON SHELL OR SKIRT, PAD PLATE MATERIAL SHALL BE
IMPACT TESTED. a.) BEAM OBSTRUCTING PASSAGEWAYS OR OVERHEAD OBSTRUCTIONS

b.) POSTS PROTECTED EQUIPMENT FROM TRAFFIC

APPROVED FOR DESIGN

F F

STOOL
PIPE DWG NO. TITLE

REFERENCE DRAWINGS

STOOL END
PLATE
CLEAT PIPE
PAD PLATE D1 APPROVED FOR DESIGN K.U S.I Y.H OCT.22.'18

FLANGE C1 ISSUED FOR APPROVAL K.U S.I Y.H JUL.18.'18


PAD PLATE
A1 ISSUED FOR INTERNAL REVIEW K.U S.I Y.H JUN.22.'18

NO. DESCRIPTION BY CHKD APVD APVD DATE

REVISIONS

REV DATE APPROVED

ISSUED FOR CONSTRUCTION

DATE

G BY G

STOOL PIPE END PLATE DRAWN DSGND CHKD APVD APVD

ALL RIGHTS RESERVED


THIS DOCUMENT IS THE PROPERTY OF QATARGAS OPERATING COMPANY LIMITED AND CONTAINS
INFORMATION WHICH IS PROPRIETARY. THIS INFORMATION IS TO BE HELD IN CONFIDENCE.
NO DISCLOSURE OR OTHER USE OF THIS DOCUMENT IS TO BE MADE WITHOUT THE PRIOR

PAD PLATE LADDER CLIP WRITTEN CONSENT OF QATARGAS OPERATING COMPANY LIMITED.

NORTH FIELD EXPANSION PROJECT


Onshore Facilities FEED
Contract No.

Qatargas Operating
Company Limited
LADDER CLIP QATARGAS

TITLE

STANDARD DRAWING
H H

PLATFORMS FOR STATIC EQUIPMENT

GENERAL NOTE
SCALE NONE JOB NO.

PROJECT DRAWING NO. REVISION

NFEF-60-43-ST-DR-TD-011
NFEF D1

1 2 3 4 5 8 9 10 11 WORK NO.

FILE NAME : NFEF-60-43-ST-DR-TD-011_D1_000.dgn

nfef-60-43-st-dr-td-011_d1_000.dgn Default 10/17/2018 4:21:39 PM