You are on page 1of 1

1 2 3 4 5 8 9 10 11

10 500 10
NOTES
10 10
SEAL
F C 1. FOR GENERAL NOTES REFER TO DWG NO.NFEF-60-43-ST-DR-TD-011.
TYP. L C
L

35
6 3 WELD -
32.5 35 35 2. FOR HOT AND COLD INSULATION THICKNESS(T&Ta) TO VESSEL,

21

70
32.5 SEE PLATFORM DESIGN DRAWINGS.

55

55
FRONT SIDE FRONT SIDE

35

35
A A
L-70x70x10 RB-20 3. LUGS WELDED TO VESSEL SHALL BE FURNISHED.

145
FB-65x10 L-70x70x10
PL-10 PL-10

55

55
18 HOLE ON STRINGER 18 HOLE ON STRINGER 4. UNLESS NOTED OTHERWISE, FILLET WELD SIZE SHALL BE
FOR STRINGER L-70x70x10 ROUGHEN EXISTING
18x50 SLOT HOLE ON LADDER 18x50 SLOT HOLE ON LADDER REFERRED TO DWG NO.NFEF-60-43-ST-DR-TD-001.
PAVING SURFACE
(M16 O.S. BOLT W/ WASHER

35

35
90 (M16 O.S. BOLT W/ WASHER 5. SAFETY CAGES SHALL BE PROVIDED FOR ALL LADDERS OF 2500MM
90
10 500 10 TO SLOT SIDE) TO SLOT SIDE) AND OVER, FLOOR TO FLOOR HEIGHT.
HPP+150 (TOF) HPP+150 (TOF)

150
10 10 40 60 60 40 D1
6. LEGEND
6 6 (SURFACE OF CONCRETE) (FINISHED GRADE)

32.5
SJ : SLIDING JOINT FOR LADDER CLIP
TYP. SEAL

300
FJ : FIXED JOINT FOR LADDER CLIP
6 3 WELD
HPP : HIGH POINT OF PAVING

21

65
100 200 19 HOLE FOR 19 HOLE FOR
TOG : TOP OF GRATING

32.5
†" ANCHOR BOLT †" ANCHOR BOLT
FB-65x10 RB-20 7. SAFETY GATE SHALL BE IN ACCORDANCE WITH "DETAIL OF
60 500 60 (REFER TO NOTE.8 OF (REFER TO NOTE.8 OF SAFETY GATE" IN NFEF-60-43-ST-DR-TD-005.
NFEF-60-44-CI-DR-TD-010) 100 200 NFEF-60-44-CI-DR-TD-010)
820
8. P.T.F.E CONNECTION (DISSIMILAR METALS) SHOULD OBEY
FOR STRINGER FB-65x10
LANDING AT PAVED AREA LANDING AT UNPAVED AREA PLATFORM DESIGN DRAWINGS
B B

CAGE HOOP TO STRINGER CONNECTION LADDER SUPPORT AT CONC. FOUNDATION (WITH LADDER STRINGER FB-65x10) (WITH LADDER STRINGER L-70x70x10)
DETAIL OF RUNG

ALWAYS PROVIDE STD. CAGE WITH


SECTION F H H
INSULATION OR
- - L-70x70x10 -
CASE FOR
STIFFENER

EXTENDED VERTICAL BARS


COLD SERVICE 200
90 400 90 400
FB-65x10
90 90 400 90 400

55

55
380 RADIUS 1200 OR LESS ALWAYS PROVIDE STD. CAGE WITH

35
EXTENDED VERTICAL BARS PL-10

145
90 400
440 RADIUS SAFETY GATE PL-10

55

55
G
250 250

L RUNGS
(BOTTOM HOOP 0 0 0 0
38 38 38 38
500

ONLY) LADDER R LADDER R C R R -


C C LLADDER C
LLADDER
L L

35

35
HOOP HANDRAIL
400

400

C
HOOP
°
P
40

PL-6x60x60 PL-6x60x60
TY

FB-50x6 FB-50x6

300
C C
FACE OF FACE OF
440

880
H/R POST H/R POST C R 40 60 6 6 60 40
LLADDER

OR LESS
175 H/R

300
SUPPORTING BEAM HOOP HOOP
CASE FOR OF LADDER CLIP H/R
220 400 FB-50x6 FB-50x6
MIN. HOT SERVICE LADDER SUPPORT AT GRATING FLOOR
BACK OF GATE POST

900
C 40 660 RUNGS C
L 40 660
RUNGS L
220 700 200 700
MIN. MIN. 300 300
65 OR 70
WELD ADDITIONAL VERTICAL
SECTION A SECTION B SECTION C SECTION J SECTION K BAR FOR CORNER CONDITION
= =
- - - - - 18 HOLE IN LADDER
40 60 BAR 65x10 OR
SECTION E 18x50 SLOT HOLE IN CLIP
DETAIL 43 L-70x70x10
-

50
TYP. DETAIL 44 (M16 O.S. BOLT W/ WASHER
016 1- 18X40 SLOT HOLE
SAFETY GATE 016 TO SLOT SIDE)
220 200

55
D FOR M16 O.S. BOLT D
FOR HOT AND COLD SERVICE
750 MAX.

750 MAX.

100
MIN. (NOTE 7) J CLIP
W/ WASHER TO SLOT SIDE
J - K

50
50
-

55
- PL-10
90 10

725
FJ
725

MEMBER OF SIDE RAIL

35
725
FJ
H=MAX.2500

PL-6x60x60
B 100
2500

B 18 HOLE
- C MAX. UNSUPPORTED MEMBER OF
- a
HEIGHT (*) FOR LADDER SIDE RAIL

2100
H=MAX

- SECTION G SECTION H

2100
725
2100

H 2500 FB 65x10 -

725
725

- -
LADDER STRINGER
2500 H 3000 L 70x70x10 35
FB-65x10 200
1100

1100

1100
HOT INSULATION 3000 H 6000 L 100x100x8 40
MIN.
650

COLD
TOP OF GRATING
12000

650
650

E INSULATION 6000 H 9000 PFC180 45 E

PLATFORM ELEVATION
TOP OF GRATING TOP OF GRATING EXTENDED VERTICAL BARS
180

(TOP OF BEAM)
MAX.

FJ FB-50X6
180

180
C1
DETAIL 32 SJ
M12 O.S. BOLT
OF ONE LADDER

a=32.5
MAX.850
OF ONE LADDER

HOOP HOOP DETAIL 45


DETAIL 32
LADDER STRINGER 016
FB-50x6 FB-50x6
H=MAX.2500

-
MAX.3000

FB-65x10

30
MAX.
850

SJ VERT. BAR(TYP) FB 65x10


A FB-50x6 H/R POST

- APPROVED FOR DESIGN


AS

H=MAX.2500
MAX.12000

DETAIL 42
AS
850 CAGE FLARE

MAX.

200
016
850
GHT

MAX.850
F MIN. F
GHT

SJ
HEI

E
HEI

SJ NFEF-60-43-ST-DR-TD-005 STANDARD DETAILS FOR LADDER 2/2

D1
-
300
600

STANDARD DETAILS FOR LADDER 1/2


DETAIL 31
NFEF-60-43-ST-DR-TD-004
25

a=22
NUOS

DWG NO. TITLE


NUOS

-
80

REFERENCE DRAWINGS
MAX

FJ
CONTI

STIFFENER
9100 LADDER CONTI

RING
(*1) HOOP L-70x70x10
FB-100x6 DETAIL 44 LADDER STRINGER FB-50x6
9100 LADDER

D1 APPROVED FOR DESIGN K.U S.I Y.H OCT.22.'18


TYP.
016 L-70x70x10 C1 ISSUED FOR APPROVAL K.U S.I Y.H JUL.18.'18

3-50x6 BARS 200 A1 ISSUED FOR INTERNAL REVIEW K.U S.I Y.H
DETAIL 41 JUN.22.'18

TYP. EQUALLY SPACED MIN. NO. DESCRIPTION BY CHKD APVD APVD DATE
016
H=MAX.2500

REVISIONS
SJ
12000
NG

DETAIL 31

a=26
FOR LANDING OF TOP SECTION REV DATE APPROVED
SPACI
H=MAX.2500

725

- ISSUED FOR CONSTRUCTION


STIFFENER LADDER STRINGER SHALL USE L70x70x10
MAX

MAX.2400

MAX

DATE
H/R RING
CAL RUNG

G G
MAX.

BY
N.2100

25
10

DRAWN DSGND CHKD APVD APVD


T.O. FL L-100x100x8
2100
725

ALL RIGHTS RESERVED


THIS DOCUMENT IS THE PROPERTY OF QATARGAS OPERATING COMPANY LIMITED AND CONTAINS
TYPI

INFORMATION WHICH IS PROPRIETARY. THIS INFORMATION IS TO BE HELD IN CONFIDENCE.


MI

NO DISCLOSURE OR OTHER USE OF THIS DOCUMENT IS TO BE MADE WITHOUT THE PRIOR


PLATFORM ELEVATION
LEVER

15

WRITTEN CONSENT OF QATARGAS OPERATING COMPANY LIMITED.


900 MAX.

10

(TOP OF BRACKET)
NORTH FIELD EXPANSION PROJECT
300

SJ
50

SJ
LENGTH

RUNG
CANTI

Onshore Facilities FEED


650
350

Contract No.
RUNG HEIGHT AT LANDING
TOG OR GL DETAIL 42 TOG
TYP. Qatargas Operating
016
150

25
10

Company Limited
180

T.O. FL QATARGAS
a=29

PLATFORM ELEVATION
15

(TOP OF BEAM)
FOR HOT SERVICE FOR COLD SERVICE
TITLE
*1 BEND EXTENDED VERTICAL BARS FLARE SHALL BE PROVIDED AT THE RUNG STANDARD DRAWING
H AS SHOWN WHERE PASSAGE BOTTOM OF LADDER CAGE IN H

THROUGH LADDER ACCESS IS REQUIRED. SIDE APPROACH TYPE LADDER PFC180 PLATFORMS FOR STATIC EQUIPMENT
ACCORDANCE WITH "FOR HOT RUNG HEIGHT AT LANDING
(GENERAL USE) SERVICE" OF LADDER DETAIL OF LADDER (1/2)
SCALE NONE JOB NO.

DETAIL 41 TO 45 DETAIL 32 PROJECT DRAWING NO. REVISION


REFER TO "DETAIL OF LADDER (2/2)"
016 016 - D1
NFEF-60-43-ST-DR-TD-015
DRAWING NO. NFEF-60-43-ST-DR-TD-016 NFEF D1

1 2 3 4 5 8 9 10 11 WORK NO.

FILE NAME : NFEF-60-43-ST-DR-TD-015_D1_000.dgn

You might also like