Culture Documents
C
L OF PRO
POSED A
LIGNMEN
1 2 CL OF B
RG
T
L OF BRG
C
HALF PLAN AT DECK SLAB LEVEL HALF PLAN AT SOFFIT SLAB LEVEL
C
L OF BEARING 7300
C
L OF SPAN & SYMMETRY LEGEND:
- TOP REINFORCEMENT
600
- BOTTOM REINFORCEMENT
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS.
UNLESS OTHERWISE MENTIONED.
2. DO NOT SCALE THE DRAWING. FOLLOW FIGURED DIMENSIONS ONLY.
C
L OF BEARING LONGITUDINAL ELEVATION OF WEB REINFORCEMENT 3. GRADE OF CONCRETE RCC M35 (DESIGN MIX) FOR KERB HANDRAIL& POST,
SUPERSTRUCTURE.
4. GRADE OF CONCRETE RCC M40 (DESIGN MIX) FOR CRASH BARRIER.
C
L OF SPAN & SYMMETRY
5. GRADE OF STEEL SHALL BE Fe500D.
6. MINIMUM CLEAR COVER TO ANY REINFORCEMENT SHALL BE 45mm.
7. DEVELOPMENT LENGTH SHALL BE AS PER CL 15.2.3 CL 15.2.4 OF IRC 112-2011.
10a 8. LAP LENGTH OF THE STEEL SHALL BE AS PER CL 15.2.5 OF IRC 112-2011.
10
9. WELDING OF REINFORCEMENT BARS NOT PERMITTED.
10. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH OTHER
SUPERSTRUCTURE DRAWINGS.
PLAN OF WEB REINFORCEMENT 11. CONDITION OF EXPOSURE : SEVERE, SEISMIC ZONE: III
12. THE REINFORCEMENT FOR CRASH BARRIER SHOULD BE PROPERLY
ANCHORED IN DECK SLAB BEFORE CASTING THE SLAB.