Stress Analysis Report

Stator Retarder

Material’s
Part Name Part 1 Part Name Part 2
Material Steel, Cast Material Aluminum 6061-AHC
Mass Density 7.85 g/cm^3 Mass Density 2.7 g/cm^3
General Yield Strength 250 MPa General Yield Strength 275 MPa
Tensile Strength 300 MPa Tensile Strength 310 MPa
Young Modulus 210 GPa Young Modulus 68.9 GPa
Stress Poisson Ratio 0.3 ul Stress Poisson Ratio 0.33 ul
Shear Modulus 80.7692 GPa Shear Modulus 25.9023 GPa

Operating Condition
Moment
Load Type Moment
Magnitude 2746.000 N mm
Vector X -2746.000 N mm
Vector Y 0.000 N mm
FIXED CONSTRAINT
Vector Z 0.000 N mm

MOMENT
Result Summary

Genuine Design Plan Repair


Name Minimum Maximum Name Minimum Maximum
2486070 2485880
Volume Volume
mm^3 mm^3
Mass 12.4066 kg Mass 13.1533 kg
Von Mises 0.00000058365 Von Mises
0.12613 MPa 0.079227 MPa 273712 MPa
Stress MPa Stress
1st Principal -0.00793071 1st Principal
0.0730226 MPa -93593.7 MPa 141012 MPa
Stress MPa Stress
3rd Principal -0.0726149 3rd Principal
0.0102001 MPa -341937 MPa 20983.1 MPa
Stress MPa Stress
0.00000411273
Displacement 0 mm Displacement 0 mm 1.26995 mm
mm
Safety Factor 15 ul 15 ul Safety Factor 0.00165385 ul 15 ul

Summary Note:
Based on stress analysis result on Genuine Design and Plan Repair Design shows:
1. Plan Repair Von Mises Stress is higher than Genuine Design Von mises Stress
2. Plan Repair Displacement is higher than Genuine Design Displacement
3. Plan Repair Safety Factor is lower than Genuine Design Safety Factor
Conclusion:
1. It is not recommended to do the Plan Repair
2. It is recommended to create a genuine