Stator Retarder
Material’s
Part Name Part 1 Part Name Part 2
Material Steel, Cast Material Aluminum 6061-AHC
Mass Density 7.85 g/cm^3 Mass Density 2.7 g/cm^3
General Yield Strength 250 MPa General Yield Strength 275 MPa
Tensile Strength 300 MPa Tensile Strength 310 MPa
Young Modulus 210 GPa Young Modulus 68.9 GPa
Stress Poisson Ratio 0.3 ul Stress Poisson Ratio 0.33 ul
Shear Modulus 80.7692 GPa Shear Modulus 25.9023 GPa
Operating Condition
Moment
Load Type Moment
Magnitude 2746.000 N mm
Vector X -2746.000 N mm
Vector Y 0.000 N mm
FIXED CONSTRAINT
Vector Z 0.000 N mm
MOMENT
Result Summary
Summary Note:
Based on stress analysis result on Genuine Design and Plan Repair Design shows:
1. Plan Repair Von Mises Stress is higher than Genuine Design Von mises Stress
2. Plan Repair Displacement is higher than Genuine Design Displacement
3. Plan Repair Safety Factor is lower than Genuine Design Safety Factor
Conclusion:
1. It is not recommended to do the Plan Repair
2. It is recommended to create a genuine