Professional Documents
Culture Documents
Page 1 / 3
3.0 OTHER REQUIREMENT 3.1 Warranty minimum 24 months against
the manufacturing defect. 3.2 Preventive Maintenance at least 2 time
during the warranty period. 3.3 On site clinical application training on
system operations and clinical support, simple maintenance of equipment
must be provided to all designated personnel by the hospital.
4.0 DELIVERY 4.1 Delivery of item must be within 3 months after issuance
of Local Purchase Order (LPO)
5.0 The device must have certificate of item registration with Medical
Device Authority of Manufacturing from the manufacture.
RIPPLE unit Biasa Standard 25
MATRESS
1.0 GENERAL FUNCTION 1.1 The units is intended for support critical ill
ALTERNATIVE
patients in intensive care and protect from risk of skin breakdown, reduce
ANTI BED
the incidence of pressure ulcers, for pressure ulcer stage I, II, III and IV.
SORE WITH
and optimizing patient comfort. Body weight criteria above than 100kg and
PUMP up to 150kg.
(MEDIUM)
2.0 TECHNICAL REQUIREMENTS 2.1 Pump 2.1.1 size and dimension
pump (describe) 2.1.2 high quality Light weight air pump with thick metal
hanging bracket 2.1.3 Case pump material (describe) 2.1.4 Quiet pump
2.1.5 Power supply, fuse and switch 2.1.6 Pressure range, pressure
Indicator (low/failure)
2.1.7 Air flow (describe) 2.1.8 Outlet (describe) 2.1.9 Classification
(describe) 2.1.10 Tubing, cover with nylon for safety and easy cleaning.
2.1.11 waterproof stopper
2.1.12 front panel function (describe)
2.2 Mattress 2.2.1 size and dimension cell and mattress (describe)
2.2.2 mattress design: cover material 2.2.2.1 water resistance and
breathable 2.2.2.2 Two-way zip cover for infection control 2.2.2.3 Easy to
clean and launder 2.2.2.4 type of Medical Grade Nylon PVC
2.2.2.5 noise absorption patent 2.2.2.6 Anti-skid bottom provides added
resistance to sliding 2.2.2.7 Expandable air mattress system allows
variable mattress widths 2.2.2.8 Seat Function
2.2.3 mattress design: cell material 2.2.3.1 Cell-on-Cell/ Individual cells for
easy cleaning and replacement 2.2.3.2 Low Air Loss mattress with
waterproof 2.2.3.3 silent cells 2.2.3.4 vapor permeable cover
2.2.4 Easy to use transport facility 2.2.5 Quick connector and cover seals
at tubing to hold the pressure when detached from pump. 2.2.6 CPR pull
tag disconnects/ Mattress can be rapidly deflated within 10 seconds using
CPR release
3.0 OTHER REQUIREMENT 3.1 Warranty minimum 24 months against
the manufacturing defect. 3.2 Preventive Maintenance at least 2 time
during the warranty period. 3.3 On site clinical application training on
system operations and clinical support, simple maintenance of equipment
must be provided to all designated personnel by the hospital.
4.0 DELIVERY 4.1 Delivery of item must be within 3 months after issuance
of Local Purchase Order (LPO)
5.0 The device must have certificate of item registration with Medical
Page 2 / 3
Device Authority of Manufacturing from the manufacture.
Page 3 / 3