Professional Documents
Culture Documents
GATE
TRAIN LINE
449.213
TRANSFORMER
GATE
D.G.
CANTEEN
GATE
TOWER
ROOM CONTROL ROOM
STORE
WEIGHT
BRIDGE
11.70
TANK FORM AREA
GATE
GATE
WORKER
COLLECTION POINT. - 2
CAPACITY : 60m 3
GUARD
GUARD ROOM
ROOM TOILET
6.40
CAPACITY - 25m 3 UNDER GROUND
HDPE GAS PIPE
LOADING BAY
4 M. WIDE ROAD TO SARAL
9.67
CONVEYOR ROOM RO WATER 3.00
GAS PIPE LINE 12" DIA.
6.45
GAS PIPE LINE
COLLECTION TANKS 12.50 12.50
36.00
P.V.C. PAPER
B B COLLECTION POINT. - 4
E.T.P. AREA
9.00
GAS PIPE LINE
CAPACITY - 100m 3
9.98
14.33 SUMP 24.00
5.48
RO PLANT CONTROL
EQUILIZITION TANK
UP-FLOUR
ROOM
FILTER 2 E E
SETTLING 1
11.50
12.00
7.00
ROOM
D D
2
12.50
13.18
COLLECTION POINT. - 3
LOADING TRUCK STAND AREA
CAPACITY : 90m 3
SHED
GAS PIPE LINE 2" DIA.
AERATION TANK
6.00
6.00
CONVEYOR
4.00
SETTLING 2 FINAL SUMP
CANTEEN BUILDING STORE ROOM GATE GAS PIPE LINE 2" DIA.
AERATION 2
15.72
PRESSURE
FILTER
6.0 M. WIDE ROAD
GATE
CONVEYOR
GAS PIPE LINE 2" DIA. GAS PIPE LINE 2" DIA.
TRAIN LINE
PUMP
PUMP
30.00 30.00 30.00
TREATED
GAS PIPE LINE 2" DIA.
EFFLUENT SUMP
SETTLING TANK - 1 CLARIFLOCCULATOR
11.50
PRESSURE SAND FILTER
12.00
10.40
COLLECTION POINT NO. - 3
CAPACITY - 25m 3
MIXER
3.30 2.10
AERATION
GAS CONTROL
GAS PIPE LINE 2" DIA.
OPERATOR
GAS PIPE LINE 2" DIA.
TANK-1
UP-FLOW
3.00
PIPE RACK
ROOM
ETP
FILTER - 2
6.00
AERATION
AERATION
TANK-2 E TANK-3 GAS PIPE LINE TO CANTEEN
SETTLING
TANK - 2
SUMP STORAGE TANK
EQUALIZATION TANK EQUALIZATION TANK BED
6.00
TANK
5.95
TANK
RECALCULATION
HOT
SUMP
FILTER PEST
UPFLOW ANEORBTC
PUMP'S
LEV ROOM
5.33 PRIMARY FILTER
SLUDGE BED
EQUALIZATION TANK SETTLING TANK
EFFLUENT TREATMENT
PLANT PHASE - 1
202
201
D
D
LLP PUMP
COOLING
LLP TANK
TOWER
204
203
D
D
PIPE LINE
8.00
206
205
D
D
HOT & COLD WALL
208
207
WATER WATER TANK
D
TANK PUMP'S
TANK
SOFT
ETP SUMP 1
D
WATER
210
209
D
D
TANK PIPE RACK
PIPE RACK
25.30
SOFT SOFT
SORBITOL TANKS
CONTROL ROOM
WATER WATER
PANEL BOARD
TANK TANK
PUMP
14.00
5.79
HOUSE COOLING
EXISTING TOWER
212
211
D
D
PERSONAL T.P.M. SOFT SOFT
FIRE & RAW
WATER TANK
D
WATER WATER
SORBITOL TANKS
PRODUCTION HALL
214
213
D
D
PLANT
GAS PIPE LINE 2" DIA.
COOLING
STORE TOWER
ACTIVATED CARBON FILTER
D.M. W/TANK
LLP SHED
216
215
DUAL MEDIA FILTER
D
BOILER CHIMNEY BOILER CHEMICAL STORE
PUMP
F.J.P.
COOLING
TOWER
CABLE TRENCH 7.10
AIR RECEIVER
AIR RECEIVER GAS PIPE LINE 2" DIA. GAS PIPE LINE 2" DIA.
EXISTING
BOUNDARY WALL
WERE HOUSE
UTILITY BUILDING
W/TANK
TEA GARDEN
WASHING UNITE
GAS PIPE LINE 3" DIA.
12.20
6.00 52.00
GATE
W/TANK
7.60
3.0 M. WIDE PATHWAY 15.23
6.00
30.00 15.00
6.00
COOLING 11.80
7.00
COLLATOR
TOWER
ETP SUMP-2
PLOT BOUNDARY
LABORATORY COOLING
4.0 M. WIDE ROAD
SEPTIC TANK
TOWER TRAFO
2.00X6.00
1.00
15.00
TRAFO
WEIGH BRIDGE
14.50
D.G. ROOM
11.00
CONTROL ROOM FOR
WEIGH BRIDGE
73.12
14.00
N.H. 37
5.00
1.5 M. WIDE PATHWAY
5.00
33 KVA
GATE
12.00
.
DIA
3"
SWITCH YARD GA
S
PIP
E
LIN
E
7.00
TRAIN LINE
18.00
20.25
GAS PIPE LINE 3" DIA. FIRE HYDRAIN LINE
GAS PIPE LINE 3" DIA.
GAS PIPE LINE 3" DIA. UNDER GROUND MDPE GAS PIPE LINE 3" DIA. GAS PIPE LINE 3" DIA.
GATE
7.80
3.25
SEPTIC
FL BE
CHANGING
OW D
FOR150
ROOM
G
A
S
PIP
E
LIN
VISITOR'S CAR PARKING
E
3"
.
D
IA
IA
D
3"
.
E
LIN
E
PIP
BED
SCALE-1:100
TEA GARDEN
TEA GARDEN
DRAWN BY -
HEMANTA BORPATRA GOHAIN
GELLAPUKHARI ROAD TINSUKIA
P.H. 9706514704