You are on page 1of 19

Sl NO Column Size Fz Mx My Footing Group

1 23x45 510 -1.67 2.1 5


2 23x45 796 -15 0.95 6
3 23x30 116 -0.45 0.43 1
4 23x30 367 -0.3 -5.6 7
6 23x45 1114 -2.6 4.3 4
7 23x30 428 0.57 -4.7 7
9 23x30 369 -2.58 0 2
10 23x30 375 4 1 2
11 23x30 546 6 0 3
12 23x30 237 1.18 1.5 1
13 23x30 418 2 0 3
14 23x30 516 -0.03 -1.35 3
15 23x30 353 3.69 0.8 2
Design Of Isolated Footing 2 of 19
1 Footing Size Design

Load Pu 150 KN
Design Load P 110 KN

Moment in x dir Mux 0 KN-m


Moment in y dir Muy 0 KN-m

Column size cx 230 mm


cy 230 mm

SBC q 200 KN/sqm

Footing Size required A req 0.55 sqmm

L 0.80 meters
Footing Size Provided
B 0.80 meters
Area Provided A prvd 0.64 meters

Zx 0.09
Zx 0.09

Net upward pressure Nup 172 KNm2

Footing Size OK

2 Slab Design
lx 0.285
ly 0.285

Bending Moment in x dir Mx 10 KN-m


Bending Moment in y dir My 10 KN-m

Concrete fck 25 MPa


Steel fy 500 MPa

Minimum Depth Required dmin 56

Depth Provided D 350 mm


Clear Cover c 50 mm
Effective Cover d' 56 mm
Effective Depth d' 294 mm

Spacing c/c in mm
Area of Steel
10# 12# 16#
353 sqmm 223 c/c 321 c/c 570 c/c
353 sqmm 223 c/c 321 c/c 570 c/c
Minimum Ast required across x direcion
Minimum Ast required across y direcion
10
Ast across x direction 12 mm dia @ 200 mm c/c 565 sqmm
Ast across y direction 12 mm dia @ 200 mm c/c 565 sqmm
Design Of Isolated Footing 3 of 19
3 One Way Shear along x direction

Vu1 -2 KN
ζv -0.008 MPa

ζc 0.263 MPa
Vc1 62 KN

One Way Shear Check OK

4 One Way Shear along y direction

Vu1 -2 KN
ζv -0.008 MPa

ζc 0.263 MPa
Vc1 62 KN

One Way Shear Check OK

5 Two Way Shear


Vu2 94 KN
ζv 0.153 MPa

ks*ζc 1.250 MPa


Vc1 770 KN

Two Way Shear Check OK


Design Of Isolated Footing 4 of 19
L= 0.80 meters

230

230
B= 0.80 meters

150 mm 350 mm

12 mm dia @ 200 mm c/c 12 mm dia @ 200 mm c/c


Design Of Isolated Footing 5 of 19
1 Footing Size Design

Load Pu 260 KN
Design Load P 191 KN

Moment in x dir Mux 0 KN-m


Moment in y dir Muy 0 KN-m

Column size cx 230 mm


cy 300 mm

SBC q 200 KN/sqm

Footing Size required A req 0.95 sqmm

L 1.00 meters
Footing Size Provided
B 1.00 meters
Area Provided A prvd 1.00 meters

Zx 0.17
Zx 0.17

Net upward pressure Nup 191 KNm2

Footing Size OK

2 Slab Design
lx 0.385
ly 0.350

Bending Moment in x dir Mx 21 KN-m


Bending Moment in y dir My 18 KN-m

Concrete fck 25 MPa


Steel fy 500 MPa

Minimum Depth Required dmin 80

Depth Provided D 350 mm


Clear Cover c 50 mm
Effective Cover d' 56 mm
Effective Depth d' 294 mm

Spacing c/c in mm
Area of Steel
10# 12# 16#
353 sqmm 223 c/c 321 c/c 570 c/c
353 sqmm 223 c/c 321 c/c 570 c/c
Minimum Ast required across x direcion
Minimum Ast required across y direcion
10
Ast across x direction 12 mm dia @ 290 mm c/c 390 sqmm
Ast across y direction 12 mm dia @ 290 mm c/c 390 sqmm
Design Of Isolated Footing 6 of 19
3 One Way Shear along x direction

Vu1 26 KN
ζv 0.089 MPa

ζc 0.263 MPa
Vc1 77 KN

One Way Shear Check OK

4 One Way Shear along y direction

Vu1 16 KN
ζv 0.054 MPa

ζc 0.263 MPa
Vc1 77 KN

One Way Shear Check OK

5 Two Way Shear


Vu2 197 KN
ζv 0.300 MPa

ks*ζc 1.250 MPa


Vc1 822 KN

Two Way Shear Check OK


Design Of Isolated Footing 7 of 19
L= 1.00 meters

230

300
B= 1.00 meters

150 mm 350 mm

12 mm dia @ 290 mm c/c 12 mm dia @ 290 mm c/c


Design Of Isolated Footing 8 of 19
1 Footing Size Design

Load Pu 350 KN
Design Load P 257 KN

Moment in x dir Mux 0 KN-m


Moment in y dir Muy 0 KN-m

Column size cx 230 mm


cy 300 mm

SBC q 200 KN/sqm

Footing Size required A req 1.28 sqmm

L 1.15 meters
Footing Size Provided
B 1.15 meters
Area Provided A prvd 1.32 meters

Zx 0.25
Zx 0.25

Net upward pressure Nup 194 KNm2

Footing Size OK

2 Slab Design
lx 0.460
ly 0.425

Bending Moment in x dir Mx 31 KN-m


Bending Moment in y dir My 26 KN-m

Concrete fck 25 MPa


Steel fy 500 MPa

Minimum Depth Required dmin 96

Depth Provided D 350 mm


Clear Cover c 50 mm
Effective Cover d' 56 mm
Effective Depth d' 294 mm

Spacing c/c in mm
Area of Steel
10# 12# 16#
353 sqmm 223 c/c 321 c/c 570 c/c
353 sqmm 223 c/c 321 c/c 570 c/c
Minimum Ast required across x direcion
Minimum Ast required across y direcion
10
Ast across x direction 12 mm dia @ 250 mm c/c 452 sqmm
Ast across y direction 12 mm dia @ 250 mm c/c 452 sqmm
Design Of Isolated Footing 9 of 19
3 One Way Shear along x direction

Vu1 56 KN
ζv 0.164 MPa

ζc 0.263 MPa
Vc1 89 KN

One Way Shear Check OK

4 One Way Shear along y direction

Vu1 44 KN
ζv 0.130 MPa

ζc 0.263 MPa
Vc1 89 KN

One Way Shear Check OK

5 Two Way Shear


Vu2 294 KN
ζv 0.448 MPa

ks*ζc 1.250 MPa


Vc1 822 KN

Two Way Shear Check OK


Design Of Isolated Footing 10 of 19
L= 1.15 meters

230

300
B= 1.15 meters

150 mm 350 mm

12 mm dia @ 250 mm c/c 12 mm dia @ 250 mm c/c


Design Of Isolated Footing 11 of 19
1 Footing Size Design

Load Pu 450 KN
Design Load P 330 KN

Moment in x dir Mux 0 KN-m


Moment in y dir Muy 0 KN-m

Column size cx 230 mm


cy 230 mm

SBC q 200 KN/sqm

Footing Size required A req 1.65 sqmm

L 1.30 meters
Footing Size Provided
B 1.30 meters
Area Provided A prvd 1.69 meters

Zx 0.37
Zx 0.37

Net upward pressure Nup 195 KNm2

Footing Size OK

2 Slab Design
lx 0.535
ly 0.535

Bending Moment in x dir Mx 42 KN-m


Bending Moment in y dir My 42 KN-m

Concrete fck 25 MPa


Steel fy 500 MPa

Minimum Depth Required dmin 112

Depth Provided D 400 mm


Clear Cover c 50 mm
Effective Cover d' 56 mm
Effective Depth d' 344 mm

Spacing c/c in mm
Area of Steel
10# 12# 20#
413 sqmm 190 c/c 274 c/c 487 c/c
413 sqmm 190 c/c 274 c/c 487 c/c
Minimum Ast required across x direcion
Minimum Ast required across y direcion
10
Ast across x direction 12 mm dia @ 150 mm c/c 754 sqmm
Ast across y direction 12 mm dia @ 150 mm c/c 754 sqmm
Design Of Isolated Footing 12 of 19
3 One Way Shear along x direction

Vu1 73 KN
ζv 0.163 MPa

ζc 0.263 MPa
Vc1 118 KN

One Way Shear Check OK

4 One Way Shear along y direction

Vu1 73 KN
ζv 0.163 MPa

ζc 0.263 MPa
Vc1 118 KN

One Way Shear Check OK

5 Two Way Shear


Vu2 398 KN
ζv 0.505 MPa

ks*ζc 1.250 MPa


Vc1 987 KN

Two Way Shear Check OK


Design Of Isolated Footing 13 of 19
L= 1.30 meters

230

230
B= 1.30 meters

150 mm 400 mm

12 mm dia @ 150 mm c/c 12 mm dia @ 150 mm c/c


Design Of Isolated Footing 14 of 19
1 Footing Size Design

Load Pu 550 KN
Design Load P 403 KN

Moment in x dir Mux 0 KN-m


Moment in y dir Muy 0 KN-m

Column size cx 230 mm


cy 300 mm

SBC q 200 KN/sqm

Footing Size required A req 2.02 sqmm

L 1.45 meters
Footing Size Provided
B 1.45 meters
Area Provided A prvd 2.10 meters

Zx 0.51
Zx 0.51

Net upward pressure Nup 192 KNm2

Footing Size OK

2 Slab Design
lx 0.610
ly 0.575

Bending Moment in x dir Mx 54 KN-m


Bending Moment in y dir My 48 KN-m

Concrete fck 25 MPa


Steel fy 500 MPa

Minimum Depth Required dmin 127

Depth Provided D 400 mm


Clear Cover c 50 mm
Effective Cover d' 56 mm
Effective Depth d' 344 mm

Spacing c/c in mm
Area of Steel
10# 12# 20#
413 sqmm 190 c/c 274 c/c 487 c/c
413 sqmm 190 c/c 274 c/c 487 c/c
Minimum Ast required across x direcion
Minimum Ast required across y direcion
10
Ast across x direction 12 mm dia @ 150 mm c/c 754 sqmm
Ast across y direction 12 mm dia @ 150 mm c/c 754 sqmm
Design Of Isolated Footing 15 of 19
3 One Way Shear along x direction

Vu1 111 KN
ζv 0.223 MPa

ζc 0.263 MPa
Vc1 131 KN

One Way Shear Check OK

4 One Way Shear along y direction

Vu1 96 KN
ζv 0.193 MPa

ζc 0.263 MPa
Vc1 131 KN

One Way Shear Check OK

5 Two Way Shear


Vu2 499 KN
ζv 0.595 MPa

ks*ζc 1.250 MPa


Vc1 1047 KN

Two Way Shear Check OK


Design Of Isolated Footing 16 of 19
L= 1.45 meters

230

300
B= 1.45 meters

150 mm 400 mm

12 mm dia @ 150 mm c/c 12 mm dia @ 150 mm c/c


Design Of Isolated Footing 17 of 19
1 Footing Size Design

Load Pu 650 KN
Design Load P 477 KN

Moment in x dir Mux 0 KN-m


Moment in y dir Muy 0 KN-m

Column size cx 230 mm


cy 300 mm

SBC q 200 KN/sqm

Footing Size required A req 2.38 sqmm

L 1.60 meters
Footing Size Provided
B 1.60 meters
Area Provided A prvd 2.56 meters

Zx 0.68
Zx 0.68

Net upward pressure Nup 186 KNm2

Footing Size OK

2 Slab Design
lx 0.685
ly 0.650

Bending Moment in x dir Mx 66 KN-m


Bending Moment in y dir My 59 KN-m

Concrete fck 25 MPa


Steel fy 500 MPa

Minimum Depth Required dmin 141

Depth Provided D 450 mm


Clear Cover c 50 mm
Effective Cover d' 56 mm
Effective Depth d' 394 mm

Spacing c/c in mm
Area of Steel
10# 12# 20#
473 sqmm 166 c/c 239 c/c 425 c/c
473 sqmm 166 c/c 239 c/c 425 c/c
Minimum Ast required across x direcion
Minimum Ast required across y direcion
10
Ast across x direction 12 mm dia @ 150 mm c/c 754 sqmm
Ast across y direction 12 mm dia @ 150 mm c/c 754 sqmm
Design Of Isolated Footing 18 of 19
3 One Way Shear along x direction

Vu1 130 KN
ζv 0.206 MPa

ζc 0.263 MPa
Vc1 166 KN

One Way Shear Check OK

4 One Way Shear along y direction

Vu1 114 KN
ζv 0.181 MPa

ζc 0.263 MPa
Vc1 166 KN

One Way Shear Check OK

5 Two Way Shear


Vu2 594 KN
ζv 0.572 MPa

ks*ζc 1.250 MPa


Vc1 1298 KN

Two Way Shear Check OK


Design Of Isolated Footing 19 of 19
L= 1.60 meters

230

300
B= 1.60 meters

200 mm 450 mm

12 mm dia @ 150 mm c/c 12 mm dia @ 150 mm c/c