Item Text Item Image Option Text 1 Option Image 1
CLTD stand for Cooling Load Temperature
Difference

The uncontrolled entry of ventilation


untreated, outdoor air directly
into the conditioned space is
known as
Which of the following Fenestration is important in
statement is TRUE? buildings as it provides visual
communication to the outside
world

Which of the following is not Ventilation and infiltration


latent heat gain source

Which of the following The sol-air temperature depends


statements are TRUE? on indoor and outdoor
temperatures

Which of the following Infiltration load is a part of the


statements are TRUE? building load

Which of the following Cooling Load Factor is used for


statements are TRUE? both radiative as well as
convective components

Which of the following Ventilation is required for


statements are TRUE? supply of oxygen for breathing
only
Which of the following Fenestration is important in
statements are TRUE? buildings as it provides visual
communication to
the outside world
Which of the following External shading of windows is
statements are TRUE? taken care of by using a shading
coefficient
Option Text 2 Option Image 2Option Text 3 Option Image 3
Cooling Load Logarithmic Cooling Load Temperature
Temperature Difference Deviation

infiltration pressurization

Heat transfer through Heat transfer due to


fenestration generally forms a fenestration depends only on
small part of the total building the properties of the
load transparent material

Occupants body Cooking foods, baking, and


boiling

The sol-air temperature The sol-air temperature


depends on outdoor depends on outdoor
temperature and incident solar temperature, incident solar
radiation radiation and surface
properties of the wall

Infiltration load is not a part Infiltration rate increases as


of the building load the pressure difference across
the building
decreases
Cooling Load Factor is used The cooling load factor
for radiative component only increases as the thermal
capacity of the walls increase

Ventilation is uncontrolled, Ventilation requirement


while infiltration is controlled depends on occupancy and
also on activity level
Heat transfer through Heat transfer due to
fenestration generally forms a fenestration depends only on
small part of the total the properties of the
building load transparent material
Internal shading of windows The shading coefficient for
is taken care of by using a the reference SS glass is 0.0
shading coefficient
Option Text 4 Option Image 4Correct Option
Cooling Load Temperature 1
Distrubution

Fenestration 2

Fenestration is undesirable 1
and hence should be
minimized

Lightening 4

The sol-air temperature 4


depends on outdoor
temperature, incident solar
radiation, surface properties
of the wall and the external
heat transfer coefficient

Infiltration rate is 1
uncontrollable

The value of cooling load 2


factor always lies between 1
and 5

Ventilation is required for 3


supply of air for breathing
only
Fenestration is undesirable 4
and hence should be
minimized

The shading coefficient for 2


the reference SS glass is 0.5