NCK general reset: To bring the control system into a defined initial state, initialization (NCK general reset) when
the power is first connected. To execute an NCK reset, turn start-up switch S3 on the CCU to position 1 and switch
on the control. The control then powers up, the SRAM memory is erased and the machine data are preset to the
default values.
Put the S3 to 1
Then push the “S1 reset” button
TE 1/2
2. How to clear the PLC:
Note:
If a reset is initiated in switch position 3 and then acknowledged as for the GENERAL RESET function, then the
entire SRAM contents of the PLC are erased, i.e. even the system data blocks and diagnostic buffer contents are
deleted. These data can no longer be accessed. The system data blocks must be loaded again. If setting 3 (MRES)
is selected for less than 3 seconds, then no general reset is requested. The STOP LED does not light up if the
switch is not changed from setting STOP to MRES to STOP within 3 seconds if a general reset has been
requested.
Put the S4 to 3
Then push the “S1 reset” button
TE 2/2