Magnetic Flowmeter

Flow measurement
ADMAG Total Insight

Bulletin 01E21A01-01EN
The philosophy of the ADMAG TI gives ”ADMAG TI” is abbreviation for ”ADMAG Total Insight”

total insight throughout the entire life cycle

Always be your first choice


in flow measurement

Yokogawa magnetic flowmeters are supported


by a long history of more than half a century.

Histor y of Yokogawa
We added innovative specifications in each era
and have always been leading the industry.
The consistent policy of Yokogawa magnetic
flowmeter is to have high performance and
magnetic flowmeter high quality. The world's first dual frequency

2019
excitation method adopted in the ADMAG AM
series announced in 1988 has set an
New release of High
grade remote transmitter unmatched standard of measurement stability
ADMAG TI Series of magnetic flowmeter. Capacitance type
2017 completead
magnetic flowmeter ADMAG CA series has
ADMAG TI made it possible to measure low conductivity
Two dedicated product
lines with fluid to insulating adhesive fluid and semisolid
"Total Insight" concept
highly concentrated slurry. ADMAG AXR series
has realized overwhelming high performance
2012 with limited power supply voltage of
1955 1983 1988 1994 1995 2003 2009 ADMAG AXW
two-wires.
FL280 YEWMAG ADMAG AM ADMAG AE ADMAG CA ADMAG AXF ADMAG AXR Large size sensor
AC excitation Signal processing Dual frequency Integral Capacitance Enhanced dual Two-wire with dual 500mm - 1800mm And now, the birth of the ADMAG TI, adopting
First magnetic flowmeter pulsed DC excitation, explosion electrode, frequency excitation, frequency excitation
of Yokogawa Alumina ceramics proof type 0.01μS/cm low Adhesion check
the "Total Insight" concept which totally
sensor tube conductivity function supports the life cycle of the product.
measurement

1 OpreX Field Instruments OpreX Field Instruments 2


● Two dedicated product lines
● Backward compatibility ● Variety of liner materials
● Worldwide approvals ● Product Finder
● Various I/O combinations
● Current input for process Simplified
temperature
(Calorie calculation, Density correction calculation
for mass flow rate measurement)
Selection

Advanced
Flexibility

Expert What is required of a field device at the customer site based on


Guide
high performance and high quality?
● Support parameter setting
(Wizard function)
In case of field devices, customers require full support over the entire product life cycle such as easy selection of product
● Multiple languages specifications, instrument set up, operation, monitoring of process, simplified troubleshooting when product fails,
flexibility for future upgrades and so on.
● Cable connection
Data check function
Yokogawa's flowmeter adopts the new "Total Insight" concept which provides total support to customers. For
Mobility example, the AXG and AXW transmitters have a wizard function for easy parameter setting. Self-diagnostics
check measurement result and automatically detect abnormalities. The built-in health check verification
● Available microSD card function can easily verify the device conditions in only 12 minutes and can output reports using the
(Easy data transfer Realized) DTM tool. The flowmeters have in-built intelligence to detect process abnormalities such as flow
● Detailed process analysis
Process noise (slurry, air bubbles) and changing fluid conductivity. These alarms can be logged for
Guard further analysis thereby maintaining the integrity of the process. These functions can be
expected for detecting the timing of fluid changes, estimating liner abrasion etc.

Data logging function


Maintenance

These advanced new functionalities offered by the "Total Insight" concept
Application diagnostic enable more accurate and stable measurement of your process.
Manager

● NAMUR mode
● Variety
of verification

3 OpreX Field Instruments OpreX Field Instruments 4


0 1
Simplified Selection

Two dedicated product lines

Purpose - Superior measurement accuracy for demanding process


▪ Standard accuracy : ±0.3% of rate
▪ High accuracy : ±0.15% of rate (25 to 200mm)
- Stable and reliable measurement for severe application

Demands - High accuracy, application diagnostics


- High durability, wide selection of wetted parts material
- Intrinsically safe Output (To be released)
- Current input for process temperature
(Calorie calculation, Density correction calculation

2
for mass flow rate measurement) Wizard function

Purpose - Accurate measurement for versatile application


Eliminate the guesswork. The wizard function
at lower cost of ownership
▪ Standard accuracy: ±0.35% of rate helps you set up the transmitter by step by step
- Reliable measurement in versatile applications parameter setting.

Demands - Fast and reliable measurement with noise immunity

0
Product Finder Expert Guide
Selecting the suitable flowmeter should be simple and, with the Yokogawa selection
tool, it is. The tool allows you to select the best size, materials, and functionality
for your process to ensure the optimal unit
to be selected for your application. Multiple languages
From selecting the best unit to
choosing the functionality
required, it is all done As a global company, we know we need to speak a
in a matter of a number of languages. That’s why we have incorporated
few clicks. multiple languages, which are user selectable, into our
latest flowmeter.
Cable connection check function
E n g lis h
French
Reduce your installation and G e r ma n
commissioning time by Excitation
cable
I t a lia n
avoiding incorrect wiring and Sp a n is h
combination of the devices. Signal
Po r t u g u e s e
cable
The diagnostic function R u s s ia n
ensures that the connection Excitation
cable C h in e s e
between the sensor and
Japanese
transmitter is correct and Signal
cable
functioning properly.
5 OpreX Field Instruments OpreX Field Instruments 6
Data logging function Application diagnostic NAMUR mode

By using the data logging function, a maximum of 4 different trends or Application diagnostic can detect various process conditions A total of 28 system and process alarms can be
events from 8 different measured variables can be stored on the microSD of your site by actively utilizing flow noise signal. individually classified according to NAMUR NE 107.
card at the same time. It is also possible to quickly troubleshoot by exporting The user can adapt the action of each alarm
- Detection of flow noise (air bubbles, slurry)
recorded trend data and alarm information to PC. individually to the process requirements and prevent
- Detection of coil insulation deterioration
unnecessary alarms from distracting plant operators.
- Detection of electrode insulation deterioration
Alarms can be classified as Failure, Function Check,
- Detection of fluid conductivity decrease
- Detection of electrode adhesion (insulator) Out of Specification or Maintenance Required.

A stable flow measurement and accurate flow noise detection.


(When changing the conductivity of fluid)

Variety of verification Company A: Flow Signal Output

Company B: Flow Signal Output

Ensuring the correct performance of critical plant


instrumentation is costly, time consuming, and can result in The flow signal is continuously stable

3
AXG: Flow Signal Output by dual frequency excitation method.
lengthy plant downtime. The AXG and AXW verification function allows
←When the conductivity is
the health of the flowmeter to be confirmed easily. Verification results can 0.3μS/cm
AXG:
be obtained as a report for maintenance records. Flow Noise Output cm/s
When the conductivity is
1μS/cm ↓
When the conductivity is 5V
1μS/cm ↓ Output

AXG  Warning signal (Status Output) is output


Status Output when the conductivity is over the threshold 1μS/cm.

0
Time 10min/div
Verification via display or communication
Built-in verification
-
-
Magnetic circuit check
Excitation circuit check Process Guard
- Calculation circuit check
- Device status check
- Connection status check Select the Execute the
- Physical appearance check Verification Built-in Verification

4
Verification with the ADMAG TI Verification Tool (FSA130)
Standard verification Standard verification

- Built-in verification and physical


appearance check
Control
- Checking for LCD display

0
(with 4 display patterns)
- Verification result is output
as a report Verification for

Maintenance
transmitter

Enhanced verification
Verification for
Manager
- Standard verification and flow sensor
Calibrator
additional external verification
- Verification result is output
as a report
- Multi meter
Report - Insulation meter

Enhanced verification
7 OpreX Field Instruments OpreX Field Instruments 8
6
Backward compatibility Various I/O combinations

0
The ADMAG TI ensures backward compatibility Whether you have a DCS, PLC, or even just a local
for retrofit. The ADMAG TI transmitters can be controller, the ADMAG TI offers multiple combination of

Advanced Flexibility paired with earlier generation Yokogawa


sensors or even third party flow tubes. This
I/O (including current input) and communication types.
This gives you the flexibility in receiving the process
helps to optimize inventory and maximize information as the way you want to.
useful life of existing equipment which results
Input/Output Signal Terminal
in considerable savings in capital expenditure.
AXG1A AXG4A AXW4A

5
Transmitter Transmitter
High grade
Transmitter AXG AXW
Integral Type Integral Type

Current Output ● ● ●
Current Input ● ● -
Pulse/Status Output ● ● ●
Status Output ● ● -
The AXG1A is the successor to the AXFA11, and Status Input ● ● ●

0
inherits the placement positions of the input Alarm Output ● - -
and output terminals and the hole positions ●: Available -: Not available
for mounting the stanchion. Therefore, it is Comunication Protocol
easy to replace AXFA11 to AXG1A. AXG1A AXG4A
Transmitter
AXW4A
Transmitter
High grade
AXG AXW

Data Mobility
Transmitter
Integral Type Integral Type

HART7 ● ● ●

BRAIN ● ● ●
Modbus - ● ●

FOUNDATION Fieldbus - ● ●
PROFIBUS PA - ● ●
Available microSD card ●: Available -: Not available

(Realize easy data transfer)


Worldwide approvals

The ADMAG TI supports microSD card for


There are a number of approvals required in various
storing multiple information related to
regions throughout the world. To meet the needs of all
process measurements, device diagnostics,
markets and applications, the ADMAG TI offers multiple
maintenance data and so on.
communication protocols, explosion proof, SIL (Safety
Integrity Level IEC61508), EMC, NAMUR, marine
It can also be used to back up device
certificate and hygiene standards.
parameter setting and factory settings which
can be restored if required. A removable
display also has storage functionality similar
to the microSD card. The data mobility
provided by the microSD card and removable
display helps for easy cloning of parameters
to similar devices drastically saving
commissioning and start up man hours.

Recorded trend data and alarm information


can be exported to PC for ease of
troubleshooting.

9 OpreX Field Instruments OpreX Field Instruments 10


Simplified Selection

Specification of
AXG and AXW transmitters

AXG1A AXG4A AXW4A AXG1A AXG4A AXW4A


Transmitter Transmitter Transmitter Transmitter Transmitter Transmitter

Current, Pulse,
Sensor combination AXG、AXW AXG AXW Current 2ch Current 2ch Current 1ch
Status Output
(AXG/AXW) 2.5 to 1800mm 2.5 to 400mm 25 to 1000mm Pulse/Status 2ch Pulse/Status 3ch Pulse/Status 2ch
(max. channel) (Note 1)

Dual frequency Status input 2ch 1ch 1ch


2.5 to 400mm 2.5 to 400mm 25 to 400mm
excitation (Note 1) (Independent) (Selectable) (Selectable)

Current input
4 lines display 4 lines display 4 lines display for process temperature 1ch
LCD (For calc. Calorie, 1ch N/A
(Max 8 lines with scroll) (Max 8 lines with scroll) (Max 8 lines with scroll) (Selectable)
Density correction) (Note 1)

microSD card Yes Yes Yes HART 7, BRAIN,


Intrinsically safe output N/A N/A
data storage (Option) (Option) (Option) FOUNDATION Fieldbus

Self-diagnostic Multiple languages


Yes Yes Yes 9 Languages 9 Languages 9 Languages
(Adhesion, Empty pipe)

HART 7, BRAIN, Modbus, HART 7, BRAIN, Modbus,


Communication
Built-in verification Yes Yes Yes HART 7, BRAIN FOUNDATION Fieldbus, FOUNDATION Fieldbus,
protocols
PROFIBUS PA PROFIBUS PA

Standard/Enhanced Yes Yes Yes


Verification SIL certification N/A Yes Yes
with FieldMate
(with FSA130) (with FSA130) (with FSA130)

Yes Yes
Combine with
Application diagnostic (Low conductivity, (Low conductivity, N/A Yes Yes N/A
AXF flow sensor
Bubble, Slurry etc) Bubble, Slurry etc)

Japan, IECEx, ATEX, IECEx, ATEX,


Explosion Signal Cable Length
N/A USA (FM), Canada (FMc), Korea, Brazil (INMETRO), 200m 100m 100m
protection use (max)
Korea, Brazil (INMETRO),EAC EAC

Note 1 : The combinations of current input/output, pulse output and status input/output depend on selections
11 OpreX Field Instruments of communication and input/output suffix code. OpreX Field Instruments 12
Simplified Selection

Definition of AXG and AXW Flow sensors


Specification of AXG and AXW Flow sensors Diameter (mm) 2.5 5 10 15 25 50 200 400 500 1000 1100 1800

Ceramics

PFA

PTFE
AXG Flow sensor AXW Flow sensor
Polyurethane rubber

Natural hard rubber


Size 2.5 to 500mm 25 to 1800mm
Natural soft rubber
PTFE,Polyurethane rubber,
Liner material Ceramics, PFA Natural hard rubber,
Natural soft rubber
AXG
General purpose use Yes Yes - The liner materials are ceramics and PFA with variety of electrode materials
- Size coverage is 2.5mm to 500mm
Japan, IECEx, ATEX, IECEx, ATEX,
Explosion protection use USA (FM), Canada (FMc), Korea, Brazil (INMETRO), AXW
Korea, Brazil (INMETRO), EAC EAC
- The liner materials are PTFE, Polyurethane rubber, Natural soft rubber,
Natural hard rubber with stainless steel and nickel alloy electrodes
Hygienic use Yes N/A - Size coverage is 25mm to 1800mm (Integral type is up to 1000mm)

Submersible use Yes Yes


Superior liner Materials for AXG Cost effective liner Materials for AXW
Standard accuracy * ± 0.3% of rate ± 0.35% of rate Alumina Ceramics Fluorocarbon PTFE
- Anti corrosive material - Anti corrosive material
- Anti abrasive material - For chemical industry
± 0.15% of rate
High accuracy * N/A - For Chemical, - Temp range: -10 to 130 °C
25 to 200mm
Pulp&Paper and Mining
Polyurethane rubber
- Temp range:-10 to 180 °C
Wider flare area - Anti-abrasive material
PFA N/A
(Upgrade sealing reliability) - For general use
(water application)
Fluorocarbon PFA - Temp range: -10 to 40 °C
ASME Class 600 Flange 25 to 100mm N/A
(For high pressure application) - Anti corrosive material
- For chemical industry Natural hard rubber (Ebonite)
- Temp range: - Anti corrosive material
500mm PFA liner Yes N/A -40 to 160 °C - For oily waste water
F F F F F F
C C C C C C
- Temp range:-5 to 80 °C
F F C F F F
Built-in grounding 150 to 400mm Natural soft rubber
N/A C3 F7
electrodes Platinum-Iridium, Tantalum - Anti abrasive material
- For mining industry and so on
*Factory calibrated result - Temp range: -10 to 70 °C

13 OpreX Field Instruments OpreX Field Instruments 14


Yokogawa Electric Corporation
World Headquarters
Visit our website (Read or Click QR code) :
9-32, Nakacho 2-chome, Musashino-shi, Tokyo 180-8750, Japan
http://www.yokogawa.com/
Yokogawa Corporation of America
12530 West Airport Blvd, Sugar Land, Texas 77478, USA
http://www.yokogawa.com/us/
Yokogawa China Co., Ltd.
Yokogawa América do Sul Ltda. Room 1801, Tower B, Hongqiao Nanfeng City,
Alameda Xingu, 850 - Alphaville Industrial, No.100 Zunyi Road, Changning District,
Barueri - São Paulo/SP, 06455-030, Brazil Shanghai, 200051, China
http://www.yokogawa.com.br http://www.yokogawa.com/cn/
Yokogawa Europe B. V. Yokogawa Engineering Asia Pte. Ltd.
Euroweg 2, 3825 HD Amersfoort, The Netherlands 5 Bedok South Road, Singapore 469270, Singapore
http://www.yokogawa.com/eu/ http://www.yokogawa.com/sg/
Yokogawa Electric CIS Ltd. Yokogawa Electric Korea Co., Ltd.
1, Samarskaya street, business center Novion, Moscow, 129110, Russia (Yokogawa B/D, Yangpyeong-dong 4-Ga), 21, Seonyu-ro 45-gil,
http://www.yokogawa.ru Yeongdeungpo-gu, Seoul, 07209, Korea
http://www.yokogawa.com/kr/
Yokogawa Middle East & Africa B. S. C. (c)
Building 577, Road 2516, Busaiteen 225, Muharraq, Bahrain Yokogawa Solution Service Corporation
http://www.yokogawa.com/bh/ 9-32, Nakacho 2-chome, Musashino-shi, Tokyo 180-8750, Japan
http://www.yokogawa.com/yjp/
Yokogawa India Ltd.
Plot No.96, Electronic City Complex, Hosur Road, Bangalore - 560 100, India
https://www.yokogawa.com/in/
Printed in Japan, 103(KP) [Ed : 05/d]

Trademarks
All brand or product names of Yokogawa Electric Corporation in this bulletin are trademarks or registered trademarks of Yokogawa Electric
Corporation. All other company brand or product names in this bulletin are trademarks or registered trademarks of their respective holders.

Subject to change without notice.