You are on page 1of 1

KEY PLAN:

UP

DN
VOID

DN

VOID

UP

UP

VOID

DN

VOID
DN

UP

11 11
DT_02 DT_02

C18 C17 C16 C15 C14 C13 C12 C11 C10 C9 C8 C7 C6 C5 C4 C3 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 UP
DN

VOID

VOID
DN

DN
UP
UP

VOID
XL1 XL1 dpa NOTES:
EXC.1 EXC.4
1. Drawing to be read in conjunction with dpa's specifications and
schedules.
XL4 XL4 XL4 XL4 XL4 XL4 XL4 2. Do not scale this drawing. Figured dimensions must be used. Any
EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 detail or dimensional conflicts should be referred to dpa lighting
consultants for clarification. All dimensions to be checked on-site.
3. Contractor to ensure all luminaire installations are free of obstruction
XL4 XL4 XL4 XL4 XL4 XL4 XL4 XL4 from other services or structural elements.
EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 4. All luminaires to be accessible for installation and periodic
maintenance.
12
5. Remote drivers to be mounted in a clean, dry and accessible location
XL4 XL4 XL4 XL4 XL4 XL4 XL4 within manufacturer's specified maximum distances. Multiple drivers
EXC.2 EXC.2 EXC.2 DT_02 EXC.2 EXC.2 EXC.2 EXC.2 may be required. Exact quantities and schematics to be confirmed by
electrical contractor/consultant.
6. Installing Contractor to ensure that all drivers/control gear are
XL4 XL4 XL4 XL4 XL4 XL4 XL4 XL4 compatible with the lighting control system.
EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 7. All equipment supplied by the installing contractor shall comply with all
statutory and local authority requirements.
8. All cable, conduit and containment to electrical contractors detail and
XL4 XL4 XL4 XL4 XL4 XL4 XL4 specification.
EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2

dpa LEGENDS:
XL4 XL4 XL4 XL4 XL4 XL4 XL4 XL4
EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 Denotes luminaire

XL4 XL4 XL4 XL4 XL4 XL4 XL4


EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 XX Denotes type reference
XX
Denotes lighting control channel number
XL4 XL4 XL4 XL4 XL4 XL4 XL4 XL4
EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2

XL4 XL4 XL4 XL4 XL4 XL4 XL4 XX Denotes Elevation number
EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2 EXC.2
XL2 XL2 XX Denotes Drawing number
EXC.3 NOTE:
REFER TO D8210_EX_PL_01_02 FOR THE DROP-OFF AREA LIGHTING
EXC.3

R0 DETAILED DESIGN DR EM dpa 08/09/22


TOWER C - FRONT ELEVATION TOWER C - REAR ELEVATION
01 1 : 300 02 1 : 300 REV.
OWNER:
DESCRIPTION DRN. CKD. APPD. DATE

VIKAS TELECOM PVT. LTD.


Embassy Point, 1st Floor, 150 Infantry Road, Bangalore
560001 India

DESIGN CONSULTANT:

SMALLWOOD
83 Clemenceau Ave #14_03, UE Square Singapore 239920
AA AB AC AD AD AC AB AA website -  smallwood-sg.com T - +65.6835.4355

ARCHITECT:

COLLIERS INTERNATIONAL
First Floor | Sunnigdale
Embassy Golf Links Business Park, 
Domlur | Benguluru - 560071 | India
www.colliers.com

PROJECT MANAGER:

COLLIERS INTERNATIONAL
First Floor | Sunnigdale
Embassy Golf Links Business Park, 
Domlur | Benguluru - 560071 | India
www.colliers.com

LIGHTING CONSULTANT:

dpa dpa lighting consultants FZ LLC


Design House, PO BOX 500072
Dubai, UAE
Telephone: +971 (4) 369 4030
Email: dubai@dpalighting.com
Website: www.dpalighting.com

PROJECT:

13 Mixed-Used Development at Embassy


DT_02
Tech Village Bangalore, India

XL2 XL2 TITLE:


EXC.3 EXC.3

Exterior Lighting Elevations: Office Block C

STATUS:

DETAILED DESIGN
SCALE DATE DRAWN CHECKED SIZE

1:300 08.09.2022 DR EM A1

DWG. NO. REV. NORTH


TOWER C - ELEVATION C TOWER C - ELEVATION D
03 1 : 300 04 1 : 300
D8210_EX_EL_00_03 R0