You are on page 1of 4

Weight of Pool Structure

1. Pilecap = 1.5 m x 1.64 m x 0.3 m x 2.4 t/m3 x 4 PC = 7.08 ton


2. Slab 20 cm = 5.17 m x 7.35 m x 0.2 m x 2.4 t/m3 = 18.23 ton
3. Outside Wall 20 cm = (5.17 m + 7.35 m) x 2 side x 0.2 m x 1.48 m (height) x 2.4 t/m3 = 17.78 ton
4. Inside Wall 20 cm = 5.17 m x 0.2 m x 1.48 (height) x 2.4 t/m3 = 3.67 ton
5. Slab Filter room 10 cm = 5.17 m x 0.1 m x 1 m (width) x 2.4 t/m3 = 1.24 ton
6. Water 1.48 m (Height) = 5.17 m x 7.35 m x 1.48 m (height) x 1 t/m3 = 56.24 ton
7. Total Weight Pool Structure = 7.08 + 18.23 + 17.78 + 3.67 + 1.24 + 56.24 ton = 104.24 ton

Ultimate Load of Total Weight of Pool = 1.4 x DL = 1.4 x 104.24 ton = 145.94 ton

We have 4 Point to support Pool Structure so Each Pile should supporting 145.94 : 4 Pile = 36.49 ton /Pile (364.9 KN/Pile)

Base on Consultant Design we need 52 ton ( 520 KN) Allowable Bearing Capacity

In This drawing we used Bore Pile diameter 300 mm (Circle Bore Pile) to support Pool structure with the Depth of Pile approximately 15 m. We
would like to propose to change the pile with Driven Rectangular Pile with dimension 200 mm (Rectangular Pile) Base on Bore Hole data from
Spectra (Soil Investigation Data) we can calculated Allowable Bearing Capacity of pile as below:

Bore Hole Rectangular Pile 200 mm Rectangular Pile 200 mm


(area 400 cm2) Consultant Design (area 400 cm2) Soil Investigation Data
Allowable Bearing Capacity (KN) Allowable Bearing Capacity (KN)
BH1 520 905.27
BH2 520 571.21
BH3 520 520.17
See attachment calculation below

Base on Bearing Capacity Calculation Using Software the conclusion is Rectangular Driven Pile 200 mm Satisfy to Support Pool Load 364.9 KN /
Pile
ATTACHMENT

You might also like