Professional Documents
Culture Documents
Ultimate Load of Total Weight of Pool = 1.4 x DL = 1.4 x 104.24 ton = 145.94 ton
We have 4 Point to support Pool Structure so Each Pile should supporting 145.94 : 4 Pile = 36.49 ton /Pile (364.9 KN/Pile)
Base on Consultant Design we need 52 ton ( 520 KN) Allowable Bearing Capacity
In This drawing we used Bore Pile diameter 300 mm (Circle Bore Pile) to support Pool structure with the Depth of Pile approximately 15 m. We
would like to propose to change the pile with Driven Rectangular Pile with dimension 200 mm (Rectangular Pile) Base on Bore Hole data from
Spectra (Soil Investigation Data) we can calculated Allowable Bearing Capacity of pile as below:
Base on Bearing Capacity Calculation Using Software the conclusion is Rectangular Driven Pile 200 mm Satisfy to Support Pool Load 364.9 KN /
Pile
ATTACHMENT