You are on page 1of 2

TOS = 5.

350

Height = 1.75 m

C.O.L req = 5.35-1.75 + 0.075 = +3.675

Differential = 100 mm

Need approval from TWA that the Anchors


Pile will be less than 40xD,

TWA: please comply with the minimum


anchorage length requirement 40xD
TOS = 5.200

Height = 1.45 m

C.O.L req = 5.20-1.45 + 0.075 = +3.825

Differential = 250 mm

Need approval from TWA that the Anchors


Pile will be less than 40xD,
TWA: please comply with the minimum
anchorage length requirement 40xD
TOS = 5.200
Height = 1.45 m
C.O.L req = 5.20-1.45 + 0.075 = +3.825
Differential = 250 mm
Need approval from TWA that the Anchors
Pile will be less than 40xD,

TOS = 5.350

Height = 3.2 m (to accommodate Pit Lift Level)

C.O.L req = 5.35-3.2 + 0.075 = +2.225

Pile No.269 Need approval from TWA to cut/design


until level +2.225, because the C.O.L more than their
buttom Tolerance Maximum 200 mm from C.O.L
that TWA sent in 15 Sept 2022

TWA: No objection

TOS = 5.350
Height = 1.6 m
C.O.L req = 5.350-1.6 + 0.075 = +3.825
Pile No . 265 ,267 Need Extention

TOS = 4.850
Height = 1.6 m
C.O.L req = 4.850-1.6 + 0.075 = +3.325
Pile No . 257 Need Extention

TWA: No objection. Please follow our pile details accordingly


and submit MOS with PE endorsement for our review.