ORIGINAL DESIGN IS 255 NOS OF BORPILE VALUE ENGINEERING DESIGN IS 189 NOS OF BOREPILE

ORIGINAL DESIGN DISPLACEMENT 9.5 MM VALUE ENGINEERING DESIGN 10.44 MM


ORIGINAL DESIGN SOIL BASE PRESSURE 7.75 T/M2 VALUE ENGINEERING DESIGN SOIL BASE PRESSURE 8.50 T/M2
ORIGINAL DESIGN PUNCHING SHEAR < 1.00 VALUE ENGINEERING DESIGN PUNCHING SHEAR < 1.00
ORIGINAL EXTRA REBAR REQUIREMENT D25-100 VALUE ENGINEERING REBAR REQUIREMENT D25-100
ORIGINAL SHEAR REBAR REQUIREMENT VALUE ENGINEERING SHEAR REBAR
The Biggest Load
of Pile in this Lift
Area is = 1016 ton

Base on reaction of our pile reaction is 1016 ton, so bearing capacity of pile should bigger than 1016 ton for pile 1200 mm diameter.
Base on reaction of our pile reaction is 1124 ton, so bearing capacity of pile should bigger than 1124 ton for pile 1200 mm diameter.
The Conclusion is based on our analysis and calculation is: