STANDARD CHECKLIST FOR S3D MODEL


Str ID/ Doc. Title : MOC Originator (Sign/Date)
Department/Section : CIVIL MOC Checker (Sign/Date)
Project Name : PJ HARMONY MOC ALE/LE (Sign/Date)
Project Code : 0-8008-15-3002 MOC TA (Sign/Date)

ITEM ITEMS TO BE VERIFIED


Checker/
NO. DESCRIPTION OR ALE LE/TA REMARKS
1.0 GENERAL
1.1 Have you checked model is in the CORRECT HEIRARCHY?
1.2 Are the materials set as STEEL?
1.3 Are all members in RELATIONSHIP?
1.4 Is your structure located on the CORRECT COORDINATES?
1.5 GRID NAMES are as per PIPING INFO?
1.6
1.7
2.0 MEMBER PARTS
2.1 Have you checked the COLUMN ORIENTATION? **
2.2 Have you checked the BRACE ORIENTATION?
2.3 Are the MEMBER SIZE as per latest STAAD? **
2.4 Have you checked the CARDINAL POINTS of members?
2.5 FCJ is modeled at correct elevation?
2.6 Are the FP modeled correctly? **
2.7 Are the beams with pipe above lowered by 50mm? **
2.8 Are the beams with stopper lowered by 150mm (minimum)? **
3.0 ACCESSORIES
3.1 FLOOR boundaries and HR on member’s outside EDGE?
3.2 Have you checked the WP of STAIRS? **
Have you checked the location of LADDER considering the PEDESTAL size? (min 100mm
3.3 clearance from pedestal) **
3.4 Are the CLADDING modeled correctly?

3.5 Are the OPENINGS modeled?

3.6 Have you modeled the HR as per requirement in Dwg? (TPO, MTO, Removable HR)
4.0 FRAME CONNECTION
4.1 Have you check the elevation of HBRACE in terms of BOLTS in EM connection? **
4.2 Have you checked WHITMORE in VERTICAL BRACE AND BP detail? **
4.3 Have you checked WHITMORE in HORIZONTAL BRACE AND adjacent beam connection? **
4.4 Are the correct connection inputted?
4.5
5.0 CLASH CHECK
5.1 Have you checked the clashing with the following? **
5.2 Have you checked Civil members VS PIPES? **
5.3 Have you checked Civil members VS E&I Cable Tray? **
5.4 Have you checked Civil members VS Equipment? **
5.5 Have you checked Steel members VS Foundation? **
5.6 Have you checked the HEAD ROOM Clearance? **
5.7 Are the OPENING free of any CLASH? **
5.8 Are trolley beams operation free from any obstruction?
6.0 CONDUCT “TO DO LIST”

LEGEND: OR – Originator / Engineer ALE - Asst. Lead Engineer LE - Lead Engineer TA – Technical Auditor

NOTES: 1. Shaded cells are items not applicable to personnel verification.


2. Indicate verification of items at appropriate cells by indicating () for completed checking and ( N/A ) if not applicable.
3. Comments with “**” are considered MAJOR COMMENT

Form No. F-1025 <4>