Professional Documents
Culture Documents
VARIES
INTERIOR INTERIOR
A
COLOUR) POLYSULPHIDE SEALANT 12-15mm THICK WALL FINISH POLYSULPHIDE SEALANT WITH FULL OVERLAP AT WALL JUNCTIONS
B
(REFER TO FINISHES SCHEDULE) PLASTER STOP BEAD (REFER TO SPECS.)
PLASTER STOP BEAD PLASTER STOP BEAD
CORNICHE SIDE
MASTIC / POLYSULPHIDE SEALANT
DENSE CONCRETE BLOCKWORK FULLY
(TO MATCH WALL FINISH COLOUR)
BONDED INTO FLANKING WALLS UNLESS
MOVEMENT JOINTS INCORPORATED TO
VARIES
WALL FINISH (REFER TO FINISHES
VARIES
D
SCHEDULE)
C
10
LC
VARIES
SCHEDULE) VERIFY COLUMN DIMENSIONS INTERIOR
RC WALL (REFER TO
STRUCTURAL DRAWINGS)
RC WALL (REFER TO
STRUCTURAL DRAWINGS)
INTERIOR INTERIOR
VARIES
INTERIOR INTERIOR
GALVANIZED STEEL MESH 12-15mm THICK WALL FINISH DENSE CONCRETE BLOCKWORK FULLY
REINFORCEMENT TO ALL BLOCKWORK (REFER TO FINISHES SCHEDULE) BONDED INTO FLANKING WALLS UNLESS
AT EVERY SECOND HORIZONTAL LAYER MOVEMENT JOINTS INCORPORATED TO
INTERIOR
(REFER TO SPECS.) ABUTMENT. TO BE CONSTRUCTED IN HALF
LAP STRETCHER BOND WITH RECESSED Rev. No. Date By Description Resp. Consult
RC SLAB (REFER TO STRUCTURAL
JOINTS TO RECEIVE FINISH AS PER SPEC. 01 2020/07/30 EB UPDATED IFC SET DSA
DRAWINGS) 02 2020/10/15 SE UPDATED IFC SET DSA
12-15mm THICK WALL FINISH (REFER TO
FINISHES SCHEDULE) 400
12-15mm THICK WALL FINISH (REFER TO
FINISHES SCHEDULE)
15
INSULATION RAMMED MINERAL WOOL SKIMMED AND PAINTED SOFFIT RC SLAB (REFER TO STRUCTURAL
CL DRAWINGS)
IN SOLID BLOCKWORK
DENSE CONCRETE BLOCKWORK FULLY
FULL COURSE
200 MASTIC / POLYSULPHIDE SEALANT
VARIES
BONDED INTO FLANKING WALLS UNLESS
FIRE SEALANT TO MATCH BLOCKWORK
MOVEMENT JOINTS INCORPORATED TO
FIRE RATING
200
ABUTMENT. TO BE CONSTRUCTED IN
HALF LAP STRETCHER BOND WITH
RECESSED JOINTS TO RECEIVE FINISH
GALVANIZED STEEL DEFORMED PLATE
RESTRAINT TIES TO ALTERNATE JOINTS
(REFER TO SPECS.)
15
GALVANIZED STEEL MESH DENSE CONCRETE BLOCKWORK FULLY
INTERNAL UPVC PLASTER STOP BEAD. DENSE CONCRETE BLOCKWORK FULLY BONDED INTO FLANKING WALLS UNLESS
REINFORCEMENT TO ALL BLOCKWORK
BONDED INTO FLANKING WALLS UNLESS MOVEMENT JOINTS INCORPORATED TO
AT EVERY SECOND HORIZONTAL LAYER GALVANIZED STEEL MESH REINFORCEMENT
MOVEMENT JOINTS INCORPORATED TO ABUTMENT. TO BE CONSTRUCTED IN
10
(REFER TO SPECS.) TO ALL BLOCKWORK AT EVERY SECOND 50mm WIDE RULED JOINT LEVELLING
12-15mm THICK WALL FINISH 50mm WIDE RULED JOINT LEVELLING ABUTMENT. TO BE CONSTRUCTED IN HALF LAP STRETCHER BOND WITH
HORIZONTAL LAYER (REFER TO SPECS.) PAD. FIXED WITH 32mm SS SCREWS
(REFER TO FINISHES SCHEDULE) PAD. FIXED WITH 32mm SS SCREWS HALF LAP STRETCHER BOND WITH RECESSED JOINTS TO RECEIVE FINISH
RECESSED JOINTS TO RECEIVE FINISH
VARIES
AS PER SPEC.
LATERAL RESTRAINT PROPRIETARY SLIP TIES FOR
MOVEMENT JOINTS BETWEEN BLOCK WORK AND
ABOVE CEILING
ABOVE CEILING
12-15mm THICK WALL FINISH CONCRETE COLUMN CONNECTIONS. SIZE TO SUIT
MIN. 150
(REFER TO FINISHES SCHEDULE) LOCATION
MIN. 150
400
SECTION FIXING CENTRES ALTERNATIVE COURSES UNLESS 12-15mm THICK WALL FINISH (REFER TO
INDICATED. FINISHES SCHEDULE)
WALL FINISH TO BE FULL HEIGHT IF
SOFFIT IS TO BE SKIMMED AND PAINTED
GALVANIZED STEEL MESH REINFORCEMENT TO
DENSE CONCRETE BLOCKWORK FULLY ALL BLOCKWORK AT EVERY SECOND
BONDED INTO FLANKING WALLS UNLESS HORIZONTAL LAYER (REFER TO SPECS.)
DENSE CONCRETE BLOCKWORK FULLY BONDED GALVANIZED STEEL MESH REINFORCEMENT TO ALL MOVEMENT JOINTS INCORPORATED TO
INTO FLANKING WALLS UNLESS MOVEMENT JOINTS BLOCKWORK AT EVERY SECOND HORIZONTAL LAYER WITH ABUTMENT. TO BE CONSTRUCTED IN HALF
INCORPORATED TO ABUTMENT. TO BE FULL OVERLAP WALL JUNCTIONS (REFER TO SPECS.) LAP STRETCHER BOND WITH RECESSED
CONSTRUCTED IN HALF LAP STRETCHER BOND WITH JOINTS TO RECEIVE FINISH AS PER SPEC. GALVANIZED STEEL MESH 25 25
RECESSED JOINTS TO RECEIVE FINISH AS PER SPEC. 25 REINFORCEMENT TO ALL BLOCKWORK AFFL AFFL
12-15mm THICK WALL FINISH AFFL
12-15mm THICK WALL FINISH (REFER TO FINISHES SCHEDULE) AT EVERY SECOND HORIZONTAL LAYER
10
10 INTERIOR 10 (REFER TO FINISHES SCHEDULE)
10
WITH FULL OVERLAP WALL JUNCTIONS SUSPENDED CEILING (REFER TO
SUSPENDED CEILING (REFER TO (REFER TO SPECS.) FINISHES SCEDULE) . FOR CEILING GALVANIZED STEEL MESH
FINISHES SCEDULE) . FOR CEILING HEIGHTS REFER TO REFLECTED REINFORCEMENT TO ALL BLOCKWORK
HEIGHTS REFER TO REFLECTED CEILING PLANS AT EVERY SECOND HORIZONTAL LAYER
CEILING PLANS (REFER TO SPECS.)
INTERIOR INTERIOR 12-15mm THICK WALL FINISH
15 200 15 12-15mm THICK WALL FINISH (REFER TO FINISHES SCHEDULE)
(REFER TO FINISHES SCHEDULE) 12-15mm THICK WALL FINISH
(REFER TO FINISHES SCHEDULE)
INTERIOR INTERIOR
VARIES
INTERIOR INTERIOR
VARIES VARIES
NOTE:
FULL HEIGHT WALL (TO SLAB SOFFIT) TO BE USED FOR ALL FIRE RATED & ACOUSTIC RATED WALLS.
PLAN INTERIOR 12-15mm THICK WALL FINISH (REFER TO
FOR ALL RATED WALLS, REFER TO THE SPECIALIST CONSULTANTS DETAILS & SPECIFICATIONS
FINISHES SCHEDULE)
10
12-15mm THICK WALL FINISH (REFER TO 12-15mm THICK WALL FINISH (REFER TO DENSE CONCRETE BLOCKWORK FULLY SELECTED PAINT FINISH (REFER TO
FINISHES SCHEDULE) FINISHES SCHEDULE) BONDED INTO FLANKING WALLS UNLESS FINISHES SCHEDULE)
MOVEMENT JOINTS INCORPORATED TO
12-15mm THICK WALL FINISH (REFER TO ABUTMENT. TO BE CONSTRUCTED IN
FINISHES SCHEDULE) 12-15mm THICK WALL FINISH (REFER TO HALF LAP STRETCHER BOND WITH
FINISHES SCHEDULE) RECESSED JOINTS TO RECEIVE FINISH
DENSE CONCRETE BLOCKWORK FULLY
FINISHES SCHEDULE)
AS PER SPEC.
VARIES (REFER TO
BONDED INTO FLANKING WALLS UNLESS
MOVEMENT JOINTS INCORPORATED TO
ABUTMENT. TO BE CONSTRUCTED IN
HALF LAP STRETCHER BOND WITH
RECESSED JOINTS TO RECEIVE FINISH
AS PER SPEC.
SEALANT (TO MATCH WALL FINISH 0.25mm THICK DPC TO EXTEND OVER PROJECT:
COLOUR) FULL WIDTH OF WALL WITH OVERLAP AT
JUNCTIONS & CORNERS
FOUR SEASONS MIXED-USE
RESIDENTIAL HOTEL
VARIES