You are on page 1of 1

REFER TO HOT-01-100-02

REFER TO HOT-01-100-01

01 02 03 04 4.6 05 06 07
9100 8850 9000 9000 9000 9000
STRUCTURE OPENING
PLOT BOUNDARY LINE
Q
9000

W= OPENING WIDTH
SSL
H= OPENING HEIGHT
BOO= bottom of opening
from SSL
P
SCHEDULE OF STIFFENERS COLUMNS
9000

SIZE MAXIMUM
No. SPACING REINFORCEMENT
L W in (m)
WP1 200 100 2 4T16 T8@200
WP2 200 150 3.50 4T16 T8@200
WP3 200 200 6 4T16 T8@200
wall type ? WP4 200 250 6 4T16 T8@200
N
850

WL03 WL03
500

F:-- F:--
STC:-- STC:--
150

W= thickness of the wall


150

725 4300 360 450 150


W
150 L= Length parallel to wall
L
D
150

105-A101
150 450 150 WL03
300

E F:1 h
105-A101 STC:--
J
150

WL03 UNIT TYPE-A2


105-A101

150
F:2 h LOWER
8850

WALL TYPES LEGEND


STC:--
105-A101

860
WL03
F:2 h
150

1470
B
THICKNESS DENSITY Kg/M 3 LAYERS
STC:--

560 200
I 645
105-A101
105-A101 C G
105-A101
150 H 1875 150 300 130 6165 TYPE CODE
105-A101

150
105-A101 WL03
WL03
F:2 h
STC:50
WL01 100 1164 100mm Light weight Hollow block

305
F:2 h WP2
2540

STC:-- WL03
550 WL05 WL01 F:2 h
WL02 150 1015 100mm Light weight Hollow block

810 150
F:2 h K F:1 h WL01 STC:-- 2025 3235 200 3230
F:2 h
675 150

ASTC:54 STC:--
105-A101
WL03 150 1536 150mm CMU Hollow block

1075
STC:--
400 6100 150 1415 315 100 2820 100 300 1950 300
F WP2
WP1

150
200 1277 200mm Light weight Hollow block
100

WP4
WL04
170

105-A101
250

1310 200 1310 WL02


3020 200 3015
200

F:2 h
3025 200 3025 575 A
STC:50
WL06 200 1277 200mm CMU Hollow block
650

670
WL02 105-A101
1200
1570

F:2 h
WL05 250 1240 250mm CMU Hollow block
1570

STC:--
M

3190
wall type ? STAIR-A FIRE SERVICE NWPE 03 NWPE 04

1400

1400
WP2

105-701 VESTIBULE 1112 1113 STAIR-C


200

370 200

940

120
105-301 105-702
WL04 WL04
380 820 100 180
F:2 h F:2 h
WALL TYPES LEGEND

600 225 425


STC:-- STC:--
TERRACE

630
A
1570

350 100
1100

4225
105-701 105-801
450 150 A TYPE CODE THICKNESS LAYERS

600
105-702
250 100

WL10 100 100mm AAC

150
WL06

150
400

150 400
WP2
PLOT BOUNDARY LINE

F:2 h
2390 200 2390 150 4075 STC:55

150 150 900


WL03
F:2 h WL04
1200 150 300 500 250
150 485 1800 335 150 1200 380 150 2600 150 WL11 200 200mm AAC
STC:50 F:1 h
ASTC:54
A WL03
F:2 h
WL03
F:2 h
WL03
F:2 h WL12 250 200mm AAC + 50 INSULATION
2390
WL02
WP2 TRASH A 105-503 STC:50 STC:-- STC:50
F:2 h
RESIDENTIAL

900
2190 200 2040 150 STC:40
105-302 105-302
LIFT LOBBY WL13 310 200mm AAC + 50 INSULATION + 2 x 12.5mm PLASTER BOARD
WL03
Details for725the 105-001
250 250mm AAC

615 175
F:2 h
WL14
9000

96
STC:50

°°
WL03
garbage chute
F:2 h
opening

1185
ASTC:54 MECH. RISER WL03

675
105-504 F:2 h

500
STC:60

84
B

2445

°
200
UNIT TYPE-A3 105-A102 50 490
LOWER

760
210 150 1180 1000 360 150 100 1750 250 ELEC. RM. WL14
105-A102 A
WL14
F:2 h 105-502 F:2 h
STC:--

1260
105-001 STC:--
1180

1770
A

2585
WL13
105-504

150

150
A F:2 h
105-502 3575 STC:60 200 3575
F WL03
F:-- WP3
105-A102

200
STC:60
WL13
F:1 h 345 2000 770
STC:60 A B
105-501
L

2050
105-001
DOOR SCHEDULE_LEVELS 07

200

310

310
A
310
105-A102 310 975 1800 310 3740 3490
100

WP3
CORRIDOR
STRUCTURAL OPENING (CLEAR)

3900

200
E 105-002 CORRIDOR DOOR NUMBER
105-A102 WL13 WL04 WL04 WL04 WL04
105-002

2770
F:1 h F:-- F:-- F:-- F:--
STC:-- STC:45 STC:50 ASTC:54 STC:45
WIDTH HEIGHT FIRE RATED IN MINUTES ASTC

1650
110 200 2650 490 150 1160 200 1310 2000 1085 200 6000 200 5800 200 1760
J.8
WL13
D
F:1 h
STC:60
WP2 WP3 WP3 WP3
105-A101 D 1020 2335

385
105-A102 MECHANICAL A
JANITOR
AHU ROOM 105-011 105-A101 J 920 2335

WP3
105-307 SHOWER

200

5660
C 105-501
105-019
105-A102 150 300 150 WL13
F:1 h
A 105-A101 B 1020 2335
STC:-- 105-307
WL13
FFL +28.225
DIETITIAN
MEMBERS
LOCKER AND
105-A101 I 920 2335

200
F:2 h TOC +28.125 ABLUTION
105-303 1100 2200
9000

STC:--
105-014 PRAYER ROOM OFFICE CHANGING
A

2770
105-015 105-017 105-018

1785

1650
A
105-013
ADA SHOWER
105-304 A 1800 2435
135 1100 TOILET
CORRIDOR 105-013 105-022
105-305 A 1020 2435 39

96
°
105-012
A ENTRANCE
105-306 A 1020 2435 60

750
105-303 LOBBY A
105-011 105-014
105-A102 B 1020 2335

96°

150
PANTRY
VESTIBULE
105-304
105-A102 F 1020 2335
105-305

2080

1825
CORRIDOR CORRIDOR MALE FITNESS
105-504 A 1800 2200 120 39

1550
60 105-016 105-016 LOCKER &

96
CHANGING
150 1020 100 150 210 200 150 84°

1290
°
SPA MANAGER
OFFICE
1080 780
A
1020 WL04
F:2 h 105-020 105-501 A 1000 2000 60 39

270 150
A

1165
WL03 STC:60
105-004 105-304

150
F:2 h WL03
K
105-305 STC:-- F:2 h
ASTC:55 105-502 A 1020 2435 120 39

150
A
1020 2435

630 200
WL02
105-004
CORRIDOR
105-A102 A

1030

150 1130
F:1 h
ASTC:54 105-005
WP2
2205 200 2205 150
ENTRANCE 105-A102 E 1020 2335

100
150

150
NWPE 10 LOBBY
1440 200 1440 500
WP2
105-A102 C 1000 2335

2700
1501 105-011

1020 100
WL02
A

1400
F:1 h
105-008
105-A102 D 1780 2335
STC:--

1305
SLUICE /

1700
STORAGE WL04
105-306 WL02 F:2 h
105-A101 C 1020 2335

WP2

200 470
F:1 h

200 525
STC:60

200
STC:--
1020 2335

WP2
105-A101 E

200
1305
WP2
150 220 1020 220 150 1490 200 1490 150 1100 150 100 200 2150 200
105-A101 A 1100 2435 60

675
A
105-306 WL04
F:2 h
VOID ABOVE STC:60
MALE FITNESS
105-A101 K 1020 2335
370 1020 370
9000

WL02
F:1 h
105-010
MALE FITNESS 105-A101 H 920 2335
STC:--
105-010
BARBERS /
HAIR SALOON
105-A101 F 1995 2335 39
105-007
105-A101 G 920 2335
MALE BEAUTY
SALOON MALE SPA & 105-701 A 1100 2200 120
105-006 FITNESS
RECEPTION 105-702 A 1100 2435 120
Put one wind post 105-009 Put one wind post
here 105-503 A 1800 2235 120
400 here WL11
F:--
STC:54

WL11
F:--
STC:54

WL11
F:--
STC:54

WL11
F:--
ASTC:60

WL11
F:--
ASTC:60
105-302 A 1000 2200 120
200 600 200 6000 200 6000 200 6000 200 6000 200 6000 200 6000 200 6105 445
105-307 A 820 2435

575
WP3 WP3 WP3 WP3 WP3 WP3 WP3
J 105-013 A 1020 2435
2330
WL12
F:--

WP3
200 2330 3885 3870
WP3
200 4030 900
WL12
F:-- 3950
WP3
200 3950 905 3795
WL12
F:--

WP3
200 4100 900 3750
WL12
F:-- 2075
WP3
200 2075 450
NOTE: ALL DOORS OPENING HEIGHTS FROM FLOOR FINISH LEVEL (FFL)
STC:-- STC:-- STC:-- STC:--
9000
H
REFER TO HOT-01-100-01
REFER TO HOT-01-100-03