You are on page 1of 1

POSCO E & C

Test Report for Sieve Analysis of Coarse Aggregate


Test Method : ASTM C136

Matarbari Ultra Super Critical Coal-Fired Power


Name of Structure : Project Lab. Reference No .

Component of Structure : Testing Place: Laboratory

Type of materials : Coarse Aggregate 20mm Date of sampling : 10-04-2022, 10:30AM

Source of materials: Stone Date of testing: 23-04-2022, 04:00PM

Sampling Place: Panta-Ocean Testing Temperature: 25℃

Cumulative wt. Cumulative


Wt. Retained Percent Passing Specification Limit
Sieve Size Retained Retained
gm gm % % LCL UCL
1-in 25 mm 7428 7428 54.9 45.1 100 - 100

3/4-in 19 mm 3672 11100 82.0 18.0 90 - 100

.3/8-in 9.5mm 1524 12624 93.2 6.8 20 - 55

No. -4 4.75mm 670 13294 98.2 1.8 0 - 10

No. -8 2.36mm 74 13368 98.7 1.3 0 - 5


Pan 170.0 13538 100.0 0.0
Total 13538.0

Weight before testing 13540 Test Result :

Aggregate Mass loss(%) 0.01

100
90 LCL
Percent of Passing(%)

80 UCL
70
Percent Passing
60
50
40
30
20
10
0
25 mm 19 mm 9.5mm 4.75mm 2.36mm
Size of test sieve

Remarks:

Lab Manager QA/QC Engineer's Representative


SUMITOMO
Sinohydro POSCO Matarbari JV Consultants

You might also like