You are on page 1of 1

WIND LOAD CALCULATION REPORT

(As per IS:875, Part III - 2015)


I.Basic Information
Structure Information
Project Info.
RCH ,CHENNAI
Client Name:
Architect :
Part : D
Façade Consultant: Aluvision Façade Soulutions Pvt. Ltd.
Wind Pressuer Calculated For Corner condition - Full height from ground level

Basic Wind Speed (Vb)


Basic Wind Speed (V b) = 50 m/s CHENNAI

Building Life For Design 100 Years

{ Terrain with numerous closly spaced


Terrain Category = 3 obstructions upto 10meter }

Building Dimensions
Height (H) = 26.85 m H/W = 1.0 > 1/2 & < 3/2
Width (W) = 27.000 m L/W = 1.1 < 3/2
Length (L) = 31.000 m

II.Design Wind Speed (Vz)


(As per IS:875, Part III - 2015)
Design Wind Speed (Vz) = Vb X k1 X k2 X k3 X k4
Where,
k1 (Probability Factor) 1.08
k2 (Terrain,Height,Size Factor) 1.04 { full height }
By interpolation method
k3 (Topography Factor) 1.00
k4(Importance factor for the cyclonic reg) 1.15
Design Wind Speed (V z) = 64.85 m/s

III. Design Wind Pressure (Pd)


Calculation
Wind Pressure (P z) = 0.6 X V z2
= 2,523.15 N/m 2
Design Wind Pressure (P d) = kd X ka X kc X Pz
Where,
kd (Wind Directionality Factor) = 0.90
ka (Area Averaging Factor) = 1.00
kc (Combination Factor) = 1.00 (Clause 7.3.3.13)
Design Wind Pressure (P d) = 2270.84 N/m2

IV. Design Wind Load (F)


Information
Design Wind Load (F) = C p X Pd
Where
C pe (External Pressure Coeff) = -1.10
C pi (Internal Pressure Coeff) = -0.20
C p (Pressure Coeff) = C pe -Cpi
= 1.30
Design Wind Load (F) = C p X Pd
= 1.30 X 2,271 N/m 2
Calculated Design Wind Load = 2,952 N/m 2
295.21 Kg/m 2

IV. Design Wind Pressure 300.0 Kg/m2 SAY