You are on page 1of 2

Check 

for M 30‐ Trough bolt for Bo om Bracket (STEEL GRADE 8.8)

Fx ≔ 64 kN

Fy ≔ 112 kN

Fz ≔ 2.017 kN Mx ≔ Fy ⋅ 300 mm = 33.6 kN ⋅ m

Ul mate Tensile Strength of bolt fub ≔ 800 MPa


Dia of SS Bolt Used ds1 ≔ 30 mm
No of Bolts Ns1 ≔ 4

Bolt Parameters as per BS EN‐1993‐1‐8

αv ≔ 0.5 k2 ≔ 0.9 γM2 ≔ 1.25

Created with PTC Mathcad Express. See www.mathcad.com for more information.
Max Forces/ Bolt:

Fy Mx
Tensile/Comp Force/bolt Ft_Ed ≔ ―― + ―――― = 112 kN
Ns1 200 mm ⋅ 2

Max Horizontal Shear/bolt Fh_s ≔ Fx Fh_s = 64 kN

Max Ver cal shear/bolt Fv_s ≔ Fy Fv_s = 112 kN

No of Shear Plane n≔2


‾‾‾‾‾‾‾‾‾‾
⎛F 2 + F 2 ⎞
Resultant Shear force/ bolt ⎝ v_s h_s ⎠
Fv_Ed ≔ ――――― Fv_Ed = 64.498 kN
n

Tensile Stress Area of bolt As ≔ 561 mm 2


(ISO 898‐1:2009)
As
Shear Capcity/bolt Fv_rd ≔ αv ⋅ fub ⋅ ―― = 179.52 kN Fv_rd > Fv_Ed = 1 Hence Safe
γM2

As
Tension Capacity Ft_rd ≔ k2 ⋅ fub ⋅ ―― = 323.136 kN Fv_rd > Ft_Ed = 1 Hence Safe
γM2
Check for Interac on Equa on

Fv_Ed Ft_Ed
―― + ――― = 0.607 0.607 < 1 Hence Safe
Fv_rd 1.4 Ft_rd

Created with PTC Mathcad Express. See www.mathcad.com for more information.