RTD & THERMOCOUPLE:

RTDs are high precision devices used to measure temperature in corrosive & non corrosive
media. They are used to measure temperature from -400 °C to 600 °C. They are unequal in
performance. Stability over long period of continued use makes them unmatched for reliability.

THERMOCOUPLES are designed to suit various applications. Thermocouple assemblies are


generally used to measure temperature up to 1800 °C.

Mineral Insulated L – Shaped Mineral Insulated Male/Female


Thermocouple Assy. Thermocouple Connector (QRT Type)

High Alumina Ceramic Sheath Beaded Elements with metal Nipple-Union (N-U-N)
for high temp. application sheath & flange or threaded threaded thermowell

Coated with PTFE Coated with Cobalt base Flanged thermowell with
Alloy / Tungsten carbide open end ceramic tube

SPECIALITY THERMOCOUPLE

* Temperature sensors for Steam Sterilizers * Thermocouple for forging, & blast furnace
* Sensors for measurement of bearing temp. * Thermocouple for gas carburizing / salt bath
* Thermocouples with weld / pad fittings * Thermocouple for hot deep galvanizing
* Spring loaded Sensor with explosion proof housing * Thermocouple for gas turbine
* Roller type sensors for rotating machinery & turbines. * Thermocouple for rotary kiln
* Thermocouple for portable temperature indicators * Preheater / Precalciner Tower Thermocouple

ELTEC CABLES & INSTRUMENTS


Cell. 94269 69542 Telefax. 91-281-2459019 Email: eltecin@gmail.com
TECHNICAL SPECIFICATIONS:

Element RTD:
2 Wire / 3 Wire / 4 Wire / 6 Wire -150 – 600 °C
THERMOCOUPLE:
J (Fe / Const) 0 – 700 °C
T (Copper / Const) 0 – 400 °C
E (Chromel / Const) 0 – 800 °C
K (Chromel Alumel) 0 – 1100 °C
R (Pt / Pt – Rh 13%) 0 – 1500 °C
S (Pt / Pt – Rh 10%) 0 – 1500 °C
B (Pt – Rh 6%/ Pt – Rh 30%) 0 – 1700 °C
G,C,D (Tungsten / Rhenium) 0 – 2400 °C
Sheath Material SS 304 / SS 310 / SS 316 / Inconel 600 / SS 446 / Ceramic
Sheath O.D. 3mm to 35 mm or more
Junction Grounded / Ungrounded / Open
Insulation Mineral / Ceramic
Element Simplex / Duplex / Triplex
Termination HEAD – Flame proof or Weather Proof Cast Aluminum /SS /C.I.
Seal Pot with Male / Female Connectors
SS base plate with flying leads for Temp. Transmitters
Mounting ¼ “, 3/8 “, ½ “, ¾ “ BSP Thread / Adjustable or Fixed Flange
Termination Flame Proof or Weather Proof Head with Single, Double entry from
Cast Aluminum / Cast Iron / SS / Plastic
Seal Pot with flying leads
Seal Pot with Male / Female Connectors (QRT)
Ceramic Terminal Block with SS Base Plate
SS Base Plate with flying leads for Temperature Transmitter

ORDERING SPEICIFICATIONS:

 Temperature to be measured
 Type (Straight / L Shaped)
 Element Type (J / T / K / E / S / R / B)
 Simplex / Duplex
 Insulation (Mineral / Ceramic)
 Junction ( Grounded / Ungrounded / Open )
 Sheath O.D.
 Sheath Length
 Sheath Material ( S.S. 304 / 310 / 316 / Inconel 600 / 800 / HRS 446 / C.I. / Ceramic )
 Mounting ( BSP Thread / Adjustable Flange / Welded Flange )
 Termination (Head – FP / WP / QRT Type etc.)

RTD (PT–100) – 2 Wire / 3 Wire / 4 Wire / 6 Wire (-150 to 600 °C)


a. Wire Length
b. Probe Length
c. Accuracy (Class A/ B)

 For L Shaped Thermocouple, Please mention Sheath O.D. / Length & Material for
Hot End Arm & Cold End Arm separately.
 Thermocouple Assy. with Double Tube Ceramic Protection is also available for
high temp. applications