You are on page 1of 2

DS 21.

02
January 1997

UNIVERSAL DIFFERENTIAL
PRESSURE SWITCH
Type SPU
Spec No. 131-X-XXX
Applications
Can be used to signal when the pressure difference is too high due to
a blocked filter; too low due to flow failure, or for level control in a
pressurised vessel. Not suitable for use on a vacuum.

Conduit
Thread
Adjusting
Nut

Weight:
1.4 Kg (SPU 1201)
1.8 Kg (SPU 1202)

Type A B C D E F G H J K
Low Low SPU 1201 100 38 92 17.0 18.6 53.2 1⁄4"BSP 77 21.4 14.5
SPU1202 SPU1201 SPU 1202 92.4 42.9 100 17.0 18.6 52.6 1⁄8"BSP 90 16.2 12.5

High Dimensions in mm

High

SPECIFICATION
Type: SPU 1201 Universal Pressure Switch – Specification No. 131-1-201
SPU 1202 Universal Pressure Switch – Specification No. 131-1-202
Maximum Line Pressure: 34 bar

SPU 1201
Pressure Range: 0.2 to 4 bar
Reset Differential: 0.1 bar approx.
Maximum Differential Pressure Overload: 16 Bar

SPU 1202
Pressure Range: 12 to 250 mbar
Reset Differential: 7 mbar approx.
Maximum Differential Pressure Overload: 1 Bar

ELECTRICAL RATING
Single pole, double throw microswitch: 5 A at 250Vac (Resistive)
2 A at 440Vac (Resistive)
Earth Connection Provided
Ambient Temperature Limits: –10°C to +80°C

CONSTRUCTION
Diaphragm: Beryllium Copper
Seals: Nitrile Rubber
Pressure Chambers: Brass
Pressure Connections: SPU 1201 1⁄4" BSP
SPU 1202 1⁄8" BSP
Microswitch Housing: Zinc Diecast
Top Cover: Steel with Neoprene Gasket
Mounting Bracket: Steel zinc plated
Degree of Protection: IP65
Terminals: Accept 1mm2 wire. Larger sizes are not recommended.
Cable Entry: 20mm conduit thread adaptor supplied. SPU thread also suitable for a cable gland nut.
Pressure Medium: Air, Nitrogen, Inert Gases, Water, Steam or Mineral Oils
01/97 2 DS 21.02

INSTALLATION MOUNTING BRACKET DETAILS


Connect the high pressure and low pressure connections to the
appropriate tapping points. (HIGH or HP, LOW or LP).
In applications involving flow where differences in line pressure
between the two connections are always within the range of the switch
there is no need to fit valves.
Not suitable for use on a vacuum.

Mounting Considerations
The mounting bracket is fitted as standard.

Wiring Instructions
1. Ensure the switch is isolated.
2. Remove the lid and terminal cover.
3. User terminals 1 and 2 (or C and NC) for closed circuit below
operating pressure.
Two Slots 6.7 Wide
4. Use terminals 1 and 3 (or C and NO) for closed circuit above 12.7 Long
operating pressure.
Dimensions in mm Fig.1
5. Ensure Earth connection is used.

Adjustment WIRING
Normally Open Contact
A quarter turn of the adjusting nut will give a change in setting of
approximately 10% of the range of the SPU. (400 mbar on the
SPU 1201, 25 mbar on SPU 1202). Fig. 3.

Common Contact Normally Closed Contact

Fig.2

ADJUSTMENT

INCREASE

Adjusting Nut

Operating
Pressure
Adjustment

DECREASE

Fig.3

CAUTION
• This is a mains operated device. Local wiring regulations and usual safety precautions must be observed. Note earthing
requirements.
• Not suitable for use on a vacuum.
• Observe maximum ambient temperature.
• Interference with those parts under sealed covers renders the guarantee void.
• Design and performance of Satchwell equipment are subject to continual improvement and therefore liable to alteration without notice.
• Information is given for guidance only and Satchwell do not accept responsibility for the selection of its products unless information has
Printed in England

been given by the Company in writing relating to a specific application.


• A periodic system and tuning check of the control system is recommended. Please contact your local Satchwell Service Office for details.
©Satchwell Control System Limited - 1995 (revised January 1997)
REGIONAL OFFICES:
Satchwell Control Systems Limited, Farnham Road, Slough, Berkshire, United Kingdom SL1 4UH Bristol (0117) 9277708 London North (01753) 550550
Tel: +44 (0)1753 550550, Fax: +44 (0)1753 824078 Coventry (01203) 633220 London South (01753) 550550
Glasgow (013552) 33732 Manchester (0161) 440 8545
Haywards Heath (01444) 441800 Newcastle (0191) 232 9378
Heathrow (0181) 569 6660 Nottingham (0115) 925 6555
Leeds (0113) 2588203 Stansted (01279) 680127
London City (0171) 403 8320 Wales (01633) 877123