Professional Documents
Culture Documents
sidel.com
OPE
Sidel - Italy
formacao
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Cap 7
Cap 6
Cap 5
Cap 4
Cap 3
Cap 2
Cap 1
Lista de capítulos
HMI
ÍNDICE
DIAGNOSTICS
MANUTENÇÃO
PROCEDIMENTOS SOP
VISÃO GERAL & LAYOUT
OPE
PONTOS DE ISOLAMENTO
PICTOGRAMAS E SEGURANÇA
7
5
6
4
3
2
1
DOCUMENTAÇÃO TRAINING
DIVISÃO
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
CAPITULO 1
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
CAPITULO 2
PICTOGRAMAS E SEGURANCA
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
sidel.com
Pictogramas de segurança
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Símbolos de segurança -
Sinais de advertência
Atenção - Ler sempre com atenção. (ISO 7010).
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Símbolos de proibição
Passagem proibida a pessoas não autorizadas. (IEC 1310-1:1995 – 92/58/CEE).
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 1
sidel.com
Áreas perigosas
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Áreas perigosas
Any other use of this document content requires the explicit written permission from Sidel.
pela área em quadrículos.
SIDEL - Damm Font Salem - Portugal 2019
■ São as áreas nas quais existem riscos durante as operações normais. Estas áreas são
isoladas por meio de dispositivos de proteção, pois os riscos maiores existem quando um
■ As condições de acesso à área perigosa são em função das intervenções que devem ser
realizadas e classificadas do seguinte modo:
- Intervenções no produto
- Intervenções na máquina
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Page 1
sidel.com
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Segurança do operador
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 2
■
■
■
■
■
Outros
seguranças
Bloquear
Posicionamento
Impedir o acesso
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Legenda das principais funções das
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Interruptor geral elétrico
No quadro elétrico, na parte anterior.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Bloqueia imediatamente os
movimentos da máquina.
Page 6
– Protetores fixos
– Protetores móveis
– Barreiras fotoelétricas
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Dispositivos de proteção
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 7
normais
remoção.
cárter em chapa de ferro.
Public
Podem ser constituídos por grelhas
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Os protetores móveis (portas)
Podem ser constituídos por
grelhas metálicas, cárter em
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Page 9
ultrapassadas.
por uma pessoa.
de um alarme luminoso.
Public
São ativadas quando ultrapassadas
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Dispositivo ‘paraquedas’
Correspondente ao levantamento
corpo central.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
1
Constituído de dois órgãos, um
para cada lado, no qual um cilindro
pneumático (1) aciona o perno (2)
Bloqueia imediatamente os
movimentos de elevação
Page 1
sidel.com
máquina
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Procedimento de entrada na
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Procedimento de entrada na máquina
Pass Procedimento
o
Ajustar todas as unidades operativas que exigem a
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
1
regulação manual para que estejam prontas para
manusear o produto que deseja enviar para produção.
É aconselhável usar o produto selecionado como um guia
de referência.
Executar o procedimento de
desbloqueio da proteção para poder
entrar na máquina.
Obs.:______________________________________
___________________________________________
___________________________________________
___________________________________________
__________________________________________
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
2 O operador entra na
máquina através de
A desbloqueio das proteções
de segurança, seguir esses
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
3
máquina, o bloqueio de
C segurança é realizado
seguindo as etapas a
continuação:
HMI
CAPITULO 3
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
sidel.com
Painel do operador
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 2
A
A
Símbolo
Public
Chave dos símbolos
Área selecionada
Botão pressionado
subpágina funcional
Subpágina funcional
Botão para chamar uma
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
4
2
1
Page 3
Estrutura HMI
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
3
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 4
B
2
C
D
3
8
4
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
5
Estrutura HMI - Barra de estado
6
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
5
3
2
A
Page 5
A
utilizador
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
r
op
dir
ins
Utilizado
Nível
Inspetor
Operador
Supervisor
Barra de estado: A- Digitar palavra-passe
passe
Palavra-
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 6
B
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Barra de estado: B- Informação
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
1
C
Page 7
C
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Barra de estado: C- Alarmes
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 8
D
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Barra de estado: D- OPL
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 9
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
1
Página de alarmes - Restabelecer alarmes
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 10
9
8
7
6
5
4
3
2
1
11
10
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Estrutura da página - Barra do navegador
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 11
2
3
4
5
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
7
Visor
ON
OFF
8
ON desabilitado
OFF desabilitado
Estrutura da página - Barra de controlo
10
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 12
Receção
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
1
4
2
3
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 13
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Funções automáticas
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 14
Ícones de comando
E._________________________
B._________________________
A._________________________
D._________________________
C._________________________
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
1
Funções automáticas: Área de comandos
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 15
B
A
Public
Comandos manuais
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 16
Ícones de comando
B._________________________
A._________________________
D._________________________
C._________________________
D._________________________
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Comandos manuais: Área de comandos
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 17
A
3
4
10
6
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
A
9
8
2
7
1
Controlos manuais - A: Elevador máquina central
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 18
Ícones de comando
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
D._________________________
C._________________________
B._________________________
A._________________________
Controlos manuais: Área de comandos
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 19
1
B
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
2
5
Controlos manuais - B: Zona de armazenamento das paletes
3
4
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 20
C
3
4
10
6
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
C
9
8
2
7
1
Controlos manuais – C: Elevador máquina central
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 21
Ícones de comando
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
D._________________________
C._________________________
B._________________________
A._________________________
Controlos manuais: Área de comandos
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 22
D
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
1
Controlos manuais - D: Zona transportador paletes
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 23
E
E
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
1
Controlos manuais - E: Zona transportador paletes
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 24
Receita - Ativa
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
5
4
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 25
Receita - Geral
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
1
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 26
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
1
Receita - configuração intercalar plataforma
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 27
Eficiência
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
1
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 28
Ícones de comando
D.______________________
C.______________________
B.______________________
A.______________________
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Eficiência - Área de comandos
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 29
A
Layout
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Layout - Ícones de indicação do sistema
Ícones Significado Ícones Significado Ícones Significado
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Page 31
3
1
Public
A
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 32
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Layout - detalhe motores
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 33
D
A
B
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Diagnósticos de redes
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
2
A
Page 34
Public
1
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 35
B
Public
1
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 36
D
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
D
Diagnóstico de redes – D: Inversor
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 37
D
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Diagnóstico de redes – D: Inversor
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 38
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Diagnóstico de redes – D: Inversor
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 39
Manutenção
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
1
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 40
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Manutenção - área de comandos: Lubrificação
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 41
Ícones de comando
B._________________________
A._________________________
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Manutenção - Área de comandos
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 42
A
Parâmetros
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 43
codificador
A.1
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
A.3
A.2
A
Parâmetros - A: Configuração do
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
A.1
Page 44
A.3
A.2
A1
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
configuração do codificadorA.1
A.3
A.2
Parâmetros - A: Configuração do codificador:
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 45
B
codificador
B.1
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
B.2
B
Parâmetros - B: Configuração do came do
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 46
B.1
B
Public
B
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 47
B.2
B
Public
B
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 48
Serviços
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 49
A
A.1
A
Public
A.2
A.3
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 50
A.1
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
A.1
Serviços - A: Gestão IHM -
A.1 Alterar o idioma de exibição
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 51
A.2
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
A.2
Serviços - Gestão HMI -
A.2 Informação do projeto
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 52
A.3
Public
A.3 Limpeza do ecrã
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
CAPITULO 4
PONTOS DE ISOLAMENTO
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
sidel.com
Pontos de isolamento
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Quando se utilizam os pontos de isolamento
O interruptor principal da máquina 'switch' (ON / OFF) está localizado no
quadro elétrico, no sistema de ar comprimido, no painel do operador e nos
interruptores do motor. Podem ser trancados com cadeado.
Os interruptores "switch" são desligados nos seguintes casos:
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
1. Risco elétrico.
2. Intervenção elétrica na máquina ou no quadro elétrico, se necessária, e
de acordo com o previsto no procedimento específico ou no manual de
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
cadeado o 'switch' na
posição OFF (0) e
observar os
procedimentos de
Desativado
Ativado
Ponto a
bloquear com
cadeado
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
comprimido, bloquear
com cadeado o 'switch' na
posição OFF (0) e
observar os
procedimentos de
Ponto a
bloquear
Desativado com cadeado
Ativado
PROCEDIMENTOS SOP
CAPITULO 5
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
sidel.com
ARRANQUE
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
ARRANQUE
Passo Procedimento
1 Antes de ligar o ar comprimido e as fontes de alimentação da máquina, remover todos os objetos que não
Any other use of this document content requires the explicit written permission from Sidel.
pertençam à máquina.
SIDEL - Damm Font Salem - Portugal 2019
Verificar se os raios das barreiras de segurança e das fotocélulas não estão obstruídos.
2 Gire o interruptor principal do gabinete elétrico no sentido horário até travar na posição ON.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
6 Ajustar todas as unidades operativas que exigem a regulação manual para que estejam prontas para manusear o
produto que deseja enviar para produção.
Quando terminar, fechar todas as portas abertas para realizar as operações de ajuste e restabelecer os alarmes.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Botão da página de
Seletor no modo automático.
comandos manuais.
Seletores manual/automático.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
12 Quando o procedimento de arranque tiver sido concluído, é aconselhável monitorizar a máquina através de todos os
vários estágios dos primeiros ciclos de produção.
sidel.com
Desligar
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Desligar
Passo Procedimento
1 Antes de desligar a máquina, é aconselhável acabar o produto já no interior da máquina.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
5 Quando a máquina tiver sido esvaziada, desarmar o transportador de entrada e saída pressionando no seguinte
botão.
8
Passo
Page 4
Desligar
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Procedimento
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
sidel.com
Troca de produção
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Troca de produção
Passo Procedimento
1 1. Pressionar o botão de login.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Menu suspenso.
Confirmar o botão do programa ativo
(azul) = arranque ativado.
Notas:
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Executar o procedimento de
desbloqueio da proteção para poder
entrar na máquina.
Notas:
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Notas:
_______________________________________________
_______________________________________________
Botão da página de _______________________________________________
alarmes. _______________________________________________
_______________________________________________
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
2. Reinicializar a máquina.
Notas:
_______________________________________________
Botão Iniciar / Parar. _______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
confirmado,
ativa os botões:
1. Transportador de paletes de
alimentação.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
DIAGNOSTICS
CAPITULO 6
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
sidel.com
de segurança
Restabelecimento das barreiras
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Restabelecimento das barreiras de segurança
Passo Procedimento
1
Ativar as barreiras de segurança.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Se a luz do botão permanecer acesa no modo fixo, isto pode significar que:
1) A barreira está obstruída;
2) A barreira não está alinhada;
3) Não funciona corretamente.
Exemplo.
Notas:
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
_______________________________________________
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
A máquina é dividida em áreas que são protegidas por proteções fixas e/ou barreiras de
segurança. Estas áreas podem ser facilmente identificadas nos layouts exibidos nos
painéis do operador, graças às suas respetivas cores.
Estas podem ser consideradas como unidades independentes e, portanto, são apenas
paradas pelos elementos de segurança que controlam esta área específica, portanto, o
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Exemplo.
Notas:
______________________________________
______________________________________
______________________________________
______________________________________
______________________________________
______________________________________
_______
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0020 Porta 4 aberta - 0770S8 - Andar de cima
0021 Porta 5 aberta - 0771S0 - Andar de baixo
0022 Porta 6 aberta - 0771S3 - Andar de baixo
0023 Porta 7 aberta - 0771S5 - Andar de baixo
0024 Porta 8 aberta - 0771S8 - Andar de baixo
0033 Emergencia pressionada OP01 - 3820S1
0034 Emergencia pressionada OP02 -
0035 Emergencia pressionada OP03 - 4216S2
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0078 Segurança Barreira Zona 6
0079 Segurança Barreira Zona 7
0080 Segurança Barreira Zona 8
0097 Seccionador motor 0200Q0 aberto
0098 Seccionador motor 0205Q0 aberto
0099 Seccionador motor 0215Q0 aberto
0100 Seccionador motor 0240Q0 aberto
0101 Seccionador motor 0240Q3 aberto
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0167 Máquina erro -
0168 Máquina erro -
0169 Máquina erro -
0170 Máquina erro -
0171 Máquina erro -
0172 Máquina erro -
0173 Máquina erro -
0174 Máquina erro -
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0244 Segurança termomagnetico motor Zona 3
0245 Segurança termomagnetico motor Zona 4
0246 Segurança termomagnetico motor
0247 Segurança termomagnetico motor
0248 Segurança termomagnetico motor
0249 Segurança termomagnetico motor
0250 Segurança termomagnetico motor
0251 Segurança termomagnetico motor
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0341 Controle FBK parada de segurança Inversor 0240U0 - Elevador Camada
0342 Controle FBK Inversor
0343 Controle FBK Inversor
0344 Controle FBK parada de segurança Inversor 0400U0 Transporte Central Palete
0345 Controle FBK parada de segurança Inversor 0420U0 Transporte Entrada Palete
0346 Controle FBK parada de segurança Inversor 0430U0 Transporte Entrada Palete
0347 Controle FBK parada de segurança Inversor 0440U0 Transporte Entrada Palete
0348 Controle FBK parada de segurança Inversor 0450U0 Transporte Entrada Palete
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
0349 Controle FBK parada de segurança Inversor 0460U0 Transporte Entrada Palete
0350 Controle FBK parada de segurança Inversor 0470U0 Transporte Entrada Palete
0409 Controle FBK accionamento freio Empurrador - 0206K7
0410 Controle FBK accionamento freio Extractor folhas - 0216K7
0413 Controle FBK accionamento freio Elevador camada - 0241K6-K7
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0460 Erro circuito porta de segurança Zona 3 (Armazém de paletes)
0461 Erro circuito porta de segurança Zona 4
0462 Erro circuito isolador de manutenção
0463 Erro Circito porta Zona 6
0464 Erro Circito porta Zona 7
0465 Erro circuito barreiras de segurança Zona 1 (Máquina)
0466 Erro circuito barreiras de segurança Zona 2 (Transportadores garrafas)
0467 Erro circuito barreiras de segurança Zona 3 (Armazém de paletes)
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0519 Falha no pneu -
0520 Falha no pneu -
0521 Um ou mais nó Profibus no alarme. Confira a página de diagnóstico Profibus
0522 Um ou mais nó Profinet no alarme. Confira a página de diagnóstico Profinet.
0529 Magazine cornice falha - Paraquedas elevador magazine cornici bloqueado
0530 Magazine cornice falha - Encoder magazine cornice bloqueado
0531 Magazine cornice falha - Guia pneumatica magazine cornici bloqueado
0532 Magazine cornice falha - Segurança elevador magazine cornici
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0577 Paraquedas elevador de camada bloqueado
0578 Falha do codificador Empurrador
0579 Falha do codificador Elevador de camada
0580 Máquina falha -
0581 Máquina falha -
0582 Máquina falha -
0583 Máquina falha -
0584 Máquina falha -
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0739 Comunicação externo -
0740 Comunicação externo -
0741 Comunicação externo -
0742 Comunicação externo -
0743 Comunicação externo -
0744 Comunicação externo -
0745 Comunicação externo -
0746 Comunicação externo -
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0800 Rastreamento pallet -
0801 Rastreamento pallet -
0802 Rastreamento pallet -
0803 Rastreamento pallet -
0804 Rastreamento pallet -
0805 Rastreamento pallet -
0806 Rastreamento pallet -
0807 Rastreamento pallet -
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
0970 Falha dispositivo Profinet n.105: 1195U1
1013 Falha Nó profibus n.020: 0200U0
1014 Falha Nó profibus n.021:
1023 Falha Nó profibus n.030: 0205U0
1025 Falha Nó profibus n.032: 0215U0
1026 Falha Nó profibus n.033: 0240U0
1028 Falha Nó profibus n.035: 0280U0
1029 Falha Nó profibus n.036: 0300U0
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
sidel.com
Diagnóstico de alarme
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 2
Alarme 001
Circuito de emergência aberto.
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
O botão de paragem de emergência indicado foi pressionado.
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Programa ou camadas não selecionadas
Alarme 145 Programa ou camadas não selecionadas
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 6
Alarme 722
Entrada paletes não habilitada pela IHM.
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
O transportador de entrada de paletes está desativado.
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Máquina parada pelo OP01 Pressionar
restabelecer e reiniciar
Alarme 778 Máquina parada a partir do OP1.
Any other use of this document content requires the explicit written permission from Sidel.
Causa O botão de paragem foi pressionado ou houve uma prioridade de alarme um ou dois.
SIDEL - Damm Font Salem - Portugal 2019
Solução Pressionar o botão Executar ou Verificar e restaurar o alarme ocorrido e pressionar o botão Executar.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Exemplo
genérico
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Exemplo
genérico
Page 9 Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Proteções abertas Máquina zona 1
Alarme 065 Proteções desbloqueadas Máquina zona 1
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
foi restabelecida.
Causa
Solução
Alarme 100
Page 12
desligado.
Seccionador do motor acionado - 0240Q0
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
genérico
Exemplo
Seccionador do motor acionado - 0240Q0
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Perfil palete transportador central
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Solução Abrir o painel elétrico e armar o interruptor novamente. Antes de ligar, controlar se o circuito conectado ao
disjuntor acionado está em ordem.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Solução Abrir o painel elétrico e controlar o estado do disjuntor, identificar qual o componente que causou o problema
(por exemplo, o disjuntor de controlo ou a proteção magnetotérmica, etc.). Antes de ligar, controlar se o circuito
Exemplo
genérico
Page 15 Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Controlo FBK, contactores 945k1-2
Alarme 0281 Controlo FBK, contactores 945k1-2.
Causa Existe um problema com o funcionamento dos contactores 945k1 e 945k2 que controlam o circuito de paragem
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Solução Abrir o painel elétrico e controlar o estado do inversor danfoss. Ver os manuais Danfoss para detalhes de
diagnóstico.
Any other use of this document content requires the explicit written permission from Sidel.
Alarme 339 Controlo do inversor FBK Dispositivo empurrador camada 205U0
SIDEL - Damm Font Salem - Portugal 2019
Solução • Controlar se não está premido o botão de paragem de emergência ou se uma das portas da máquina foi
aberta. Controlar e redefinir o botão de paragem de emergência ou fechar as portas indicadas na HMI.
• Controlar se o inversor indicado está ligado.
• Controlar se o inversor indicado está em funcionamento (e não no modo de paragem local) consultando
o painel de controlo do inversor
Causa O circuito elétrico que controla a operação do motor não funciona corretamente.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Solução Controlar visualmente o estado do transportador de paletes. Abrir o painel elétrico e controlar o circuito de
controlo do motor 465M1. Especialmente os dispositivos 465Q1, 465K5 e 465K6.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa O interruptor Ethernet mostrado abaixo indica, por meio do contacto de falha mostrado, que não pode funcionar
corretamente.
Solução Controlar o funcionamento do dispositivo, controlar se está conectado e alimentado corretamente; consultar o
manual do dispositivo, se necessário.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Exemplo
Page 23 Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
genérico
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Um ou mais nós Profibus em alarme.
Controlar a página de diagnóstico do
Alarme 521 Um ou mais nós Profibus em alarme. Controlar a
Profibus
página de diagnóstico do Profinet
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 26
Alarme 561
bloqueado
bloqueado
Sensores fora de posição
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
genérico
Exemplo
Dispositivo de paragem saída palete
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 27
Alarme 562
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
genérico
Exemplo
Porta de entrada paletes bloqueada
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 28
Alarme 563
Sensores fora de posição
Guias laterais paletes bloqueadas
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
genérico
Exemplo
Guias laterais palete bloqueadas
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Segurança descendente elevador paletes
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa O sensor de segurança descendente do elevador ativou o respetivo came, de modo que o ponto de descida
mínimo possível foi atingido.
Solução Se estiver a operar no modo manual, restaurar o elevador para uma faixa operacional aceitável.
Pressionar o botão de restabelecimento.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa O sensor de segurança ascendente elevador ativou o respetivo came, de modo que o ponto de subida máximo
possível ou a altura máxima foram atingidos.
Solução Se estiver a operar no modo manual, restaurar o elevador para uma faixa operacional aceitável.
Exemplo
Page 30 genérico
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Segurança garfos armazém plataforma
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa Foi detetada uma falha no funcionamento da unidade de acionamento que controla a extensão/retração dos
garfos do armazém das plataformas
Solução Controlar se a unidade de acionamento em questão está a funcionar corretamente.
Controlar que não existem obstáculos ao movimento dos garfos.
Exemplo
genérico
Page 31 Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Segurança garfos armazém estrutura
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa Foi detetada uma falha no funcionamento da unidade de acionamento que controla a extensão/retração dos
garfos do armazém das estruturas
Solução Controlar se a unidade de acionamento em questão está a funcionar corretamente.
Controlar que não existem obstáculos ao movimento dos garfos.
Exemplo
genérico
Page 32 Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Cilindro ascendente/descendente
removedor plataformas bloqueado
Alarme 548 Cilindro ascendente/descendente
removedor plataformas bloqueado
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Exemplo
genérico
Page 35 Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Elevada temperatura do gabinete elétrico
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
não é dado
Causa
Solução
Page 38
Alarme 836
graxa ativado
Nível mínimo de graxa
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Nível mínimo de graxa
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 39
Alarme 763
Nível máx. fotocélula
Armazenamento plataforma cheio
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Armazenamento cheio
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
sidel.com
Diagnóstico de alarme
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 2
Alarme 001
Circuito de emergência aberto.
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
O botão de paragem de emergência indicado foi pressionado.
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Programa ou camadas não selecionadas
Alarme 145 Programa ou camadas não selecionadas
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 6
Alarme 722
Entrada paletes não habilitada pela IHM.
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
O transportador de entrada de paletes está desativado.
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Máquina parada pelo OP01 Pressionar
restabelecer e reiniciar
Alarme 778 Máquina parada a partir do OP1.
Any other use of this document content requires the explicit written permission from Sidel.
Causa O botão de paragem foi pressionado ou houve uma prioridade de alarme um ou dois.
SIDEL - Damm Font Salem - Portugal 2019
Solução Pressionar o botão Executar ou Verificar e restaurar o alarme ocorrido e pressionar o botão Executar.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Exemplo
genérico
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Exemplo
genérico
Page 9 Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Proteções abertas Máquina zona 1
Alarme 065 Proteções desbloqueadas Máquina zona 1
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
foi restabelecida.
Causa
Solução
Alarme 100
Page 12
desligado.
Seccionador do motor acionado - 0240Q0
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
genérico
Exemplo
Seccionador do motor acionado - 0240Q0
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Perfil palete transportador central
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 16
Alarme 561
bloqueado
Sensores fora de posição
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
genérico
Exemplo
Dispositivo de paragem saída palete bloqueado
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 17
Alarme 562
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
genérico
Exemplo
Porta de entrada paletes bloqueada
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 18
Alarme 563
Sensores fora de posição
Guias laterais paletes bloqueadas
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
genérico
Exemplo
Guias laterais palete bloqueadas
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Segurança ascendente elevador paletes
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa O sensor de segurança ascendente elevador ativou o respetivo came, de modo que o ponto de subida máximo
possível ou a altura máxima foram atingidos.
Solução Se estiver a operar no modo manual, restaurar o elevador para uma faixa operacional aceitável.
Exemplo
Page 19 genérico
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Segurança garfos armazém plataforma
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa Foi detetada uma falha no funcionamento da unidade de acionamento que controla a extensão/retração dos
garfos do armazém das plataformas
Solução Controlar se a unidade de acionamento em questão está a funcionar corretamente.
Controlar que não existem obstáculos ao movimento dos garfos.
Exemplo
genérico
Page 20 Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Segurança garfos armazém estrutura
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Causa Foi detetada uma falha no funcionamento da unidade de acionamento que controla a extensão/retração dos
garfos do armazém das estruturas
Solução Controlar se a unidade de acionamento em questão está a funcionar corretamente.
Controlar que não existem obstáculos ao movimento dos garfos.
Exemplo
genérico
Page 21 Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Cilindro ascendente/descendente
removedor plataformas bloqueado
Alarme 548 Cilindro ascendente/descendente
removedor plataformas bloqueado
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Exemplo
genérico
Page 24 Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Public
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Elevada temperatura do gabinete elétrico
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
não é dado
Causa
Solução
Page 27
Alarme 836
graxa ativado
Nível mínimo de graxa
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Nível mínimo de graxa
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Causa
Solução
Page 28
Alarme 763
Nível máx. fotocélula
Armazenamento plataforma cheio
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Armazenamento cheio
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 1
sidel.com
SIDEL
Identificação do alarme
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Objetivo
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Page 3
S7/SCL/Schneider
Public
alarme
Código do
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 4
S7/SCL/Schneider
Abrir o projeto do passo 7 e navegar em:
<ProjectName>/CPU/S7 Program/Blocks
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 5
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
«alarmes gerais» FC 200, FC 201 e DB9.
Identificação de alarme no
Se o código variar de 0 a 999, a lógica deve ser descrita nos
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 6
correspondentes
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Identificação de alarme no
Abrindo DB9, é possível encontrar a lista de erros com os
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Identificação de alarme no
S7/SCL/Schneider
Códigos com alcance maior que 999 são Alarmes Específicos-FB.
Cada módulo possui um FB dedicado à lógica do It, portanto, os
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Page 9
620.
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Identificação de alarme no
Para verificar a qual tarefa pertence o código para
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 10
DB616-HMI PAL C30.
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Open Block (Abrir Bloco) ou Ctrl + Alt + O.
Neste caso, o alarme é encontrado dentro
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 11
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Verificar o prefixo dos números do alarme.
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 12
simbólico.
atentamente o nome simbólico.
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 13
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Identificação de alarme no
S7/SCL/Schneider
Converter 26 de decimal para forma
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Código do 18 26
erro:
Page 15
código do alarme.
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Identificação de alarme no
Abrir cada bloco e usar Ctrl+f para encontrar o
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 16
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Quando o alarme for encontrado, usar Ctrl + f
novamente e procurar a constante do alarme.
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 17
escrito.
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
o PLC pelo controlador Schneider PacDrive.
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 18
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Identificação de alarme no
S7/SCL/Schneider
Semelhante à estrutura do software s7, o software do
Any other use of this document content requires the explicit written permission from Sidel.
construtor de lógica é dividido em módulos específicos
SIDEL - Damm Font Salem - Portugal 2019
Page 20
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 21
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 22
S7/SCL/Schneider
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Identificação de alarme no
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
MANUTENCAO
CAPITULO 7
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 1
sidel.com
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Lubrificação lincoln
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Avisos para a segurança
-As indicações para a segurança aqui fornecidas não devem ser consideradas
completas. Para qualquer pergunta ou problema contactar o serviço de assistência aos clientes
Any other use of this document content requires the explicit written permission from Sidel.
através do sítio internet da Lincoln (www.lincolnindustrial.com).
SIDEL - Damm Font Salem - Portugal 2019
- O lubrificador deve ser abastecido com o óleo ou a massa lubrificante adequados e pré-regulado de
modo (com a configuração regular, a aplicação e
o uso conforme as instruções) a poder funcionar sem problemas e sem
causar perigos para as pessoas.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Reparação
■ Eventuais reparações do sistema devem ser realizadas exclusivamente por pessoal
devidamente autorizado e qualificado com um conhecimento comprovado das
normas vigentes.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
– Antes de introduzir o lubrificante nas bombas com enchimento por cima da tampa, é
necessário desativar a alimentação da tensão.
– Para tornar mais rápida e segura a identificação dos tipos de lubrificantes a utilizar, respeitar
as tabelas indicadas no capítulo 7- MANUTENÇÃO ORDINÁRIA, parágrafo-LUBRIFICAÇÃO,
do manual de uso e manutenção fornecido com a máquina.
Page 5
1
2
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
3
6
5
Esquema genérico de distribuição
4
4
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 6
Tipo de lubrificante
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 7
8
Descrição
5
1
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
3
9
7
6
4
2
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Descrição
Bomba de lubrificação centralizada 203 QuickLub
– É adequada para a lubrificação automática dos pontos de lubrificação a ela conectados.
– Funciona segundo os ciclos de lubrificação pré-estabelecidos (tempo de pausa e trabalho)
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
– Poder ser dotada de sistema de controlo de nível mínimo do reservatório da massa lubrificante
com ou sem placa eletrónica incorporada.
– Durante o tempo de trabalho, a bomba distribui o lubrificante nos pontos de lubrificação a ela
conectados através de um ou mais distribuidores.
Page 9
3
1
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Modalidade de funcionamento
A
2
3
A
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 10
B
A
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Modalidade de funcionamento
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Características técnicas
Bomba Motor
■ Temperatura de exercício: ...-40°c 70°c ■ Motorredutor de corrente contínua (blindado)
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Page 12
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Página de lubrificação - painel operador
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 13
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Distribuidores progressivos
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 14
SÍMBOLO
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Fase 1
Lubrificante da bomba sob pressão
DESCRIÇÃO
A
A
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 15
Fase 2
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
5
Fase 3
Modalidade de funcionamento
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 16
3
Fase 4
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
1
Fase 5
A
Modalidade de funcionamento
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 17
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Simulação de funcionamento do distribuidor
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 1
sidel.com
processo
MANUTENÇÃO
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Documentação técnica
Modelos e descrição do
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Índice
Any other use of this document content requires the explicit written permission from Sidel.
Tipos de manutenção
SIDEL - Damm Font Salem - Portugal 2019
6 Pictogramas e Codificação
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Page 4
FMEA / AMDEC
Plano de manutenção
LILA
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
SOP AJUSTE
SOP LIMPEZA
SOP INSPEÇÃO
SOP LUBRIFICAÇÃO
SOP SUBSTITUIÇÃO
Ordinária
Ferramentas e Processo de manutenção
Manutenção
Manutenção
Extraordinária
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Plano de manutenção
Definição:
Plano de manutenção (às vezes chamado de “cronograma de trabalho”) –
Selecção de listas de verificação e outras ordens de trabalho ad-hoc agrupadas
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
para serem emitidas para uma equipa de trabalho para conclusão durante um
período de manutenção definido.
# LILA para
cada posição
de famílias Componentes Descrição da tarefa Frequência / Habilidade / Tempo por
tarefa
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Page 7
Ação
Descrição
pictogramas
Segurança e
Tipo de SOP
Equipamento
passo a passo
Limpeza
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Inspeção
SOP para Manutenção ordinária
# SOP
Lubrificação
# recurso
Ilustrações
Frequência
Tempo para
Comentários
esta operação
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 8
Ajuste
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Substituição
SOP para Manutenção Extraordinária
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 9
(exemplo)
Public
Outros pictogramas
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 10
T° frio
T° quente
7 bars On
7 bars Off
6 ou 7 bars
Energia elétrica
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Cola
Túnel
Legenda Pictogramas / Codificação
Máquina em
Modo Manual
funcionamento
Máquina ligada
Máquina desligada
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
Page 11
Public
Title, 04 March 2019 [Public / Internal / Restricted / Highly confidential]
Legenda Pictogramas / Codificação
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
SIDEL - Damm Font Salem - Portugal 2019
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL – Damm Font Salem, Portugal 2019
GIBG0272 PLANO DE MANUTENÇÃO REVISÃO 1.0 (PT-BR)
* = SOMENTE SE PRESENTE
** = SOMENTE UTILITÁRIOS NÃO FORNECIDOS COM A LUBRIFICAÇÃO AUTOMÁTICA
FAMÍLIA DESCRIÇÃO DO GRUPO TAREFA HAB/DESAB DESCRIÇÃO DA TAREFA FREQÜÊNCIA CONDICIONAL ID DO SOP ID DO SOP N° OPERADOR ESPECIALIDADE TEMPO/MÍN. FERRAMENTAS ESPECIAIS
101 ELEVADOR CT DESLIGADO ROLAMENTO DE ESFERAS PARA VERTICAL MOVIMENTO 1.500 CILT - 01.01.0001 1 2 10
101 ELEVADOR GR DESLIGADO LUBRIFICAR UTILITÁRIOS FORNECIDOS COM BICO DE GRAXA** 500 CILT - 01.01.0001 1 2 10
101 ELEVADOR CT DESLIGADO DESLIZAMENTO ROLOS 1.500 CILT - 01.01.0001 1 2 20
101 ELEVADOR RP DESLIGADO ROLAMENTO DE ESFERAS PARA VERTICAL MOVIMENTO x ERP - 0001 1 2 120
101 ELEVADOR RP DESLIGADO DESLIZAMENTO ROLOS x ERP - 0001 1 2 120
101 ELEVADOR RP DESLIGADO CORRENTE x ERP - 0118 2 2 240
101 ELEVADOR RP DESLIGADO CORRENTE x ERP - 0037 2 2 240
101 ELEVADOR CT DESLIGADO CORRENTE 1.500 ECT - 002 CILT - 01.01.0001 1 2 10
102 UNIDADE ACIONAMENTO CT DESLIGADO VERIFICAR NÍVEL DE ÓLEO NAS ENGRENAGENS REDUÇÃO 1.500 ECL - 015 CILT - 01.01.0001 1 2 10
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
102 UNIDADE ACIONAMENTO CT DESLIGADO FREIO DO MOTOR * 1.500 CILT - 01.01.0001 1 2 10
102 UNIDADE ACIONAMENTO CT DESLIGADO JUNTAS DE CARDÃ 1.500 CILT - 01.01.0001 1 2 10
102 UNIDADE ACIONAMENTO RP DESLIGADO FREIO DO MOTOR * x ERP - 0004 1 2 60
102 UNIDADE ACIONAMENTO RP DESLIGADO JUNTAS DE CARDÃ 500 ERP - 0005 1 2 60
102 UNIDADE ACIONAMENTO RP DESLIGADO TROCAR O ÓLEO NAS ENGRENAGENS DE REDUÇÃO 30.000 ERP - 0006 2 2 30
103 ÁRVORE DE CONTENÇÃO RP DESLIGADO CILINDROS PNEUMÁTICOS 12.000 ERP - 0007 1 2 30
103 ÁRVORE DE CONTENÇÃO RP DESLIGADO CANOAS LINEAR LEVANDO 12.000 ERP - 0020 1 2 30
104 VÁLVULA SOLENOIDE MONOESTÁVEL SIMPLES CT DESLIGADO VERIFICAR E LIMPAR AS VÁLVULAS SOLENÓIDE 500 CILT - 01.01.0001 1 2 5
104 VÁLVULA SOLENOIDE MONOESTÁVEL SIMPLES RP DESLIGADO VÁLVULAS SOLENÓIDE x 1 2 5
108 CARRO RP DESLIGADO TRAVÃO DO MOTOR * x ERP - 0004 1 2 60
108 CARRO CT DESLIGADO TRAVÃO DO MOTOR * 1.500 CILT - 01.02.0002 1 2 10
108 CARRO CT DESLIGADO VERIFICAR NÍVEL DO ÓLEO NAS ENGRENAGENS DE REDUÇÃO 1.500 CILT - 01.02.0002 1 2 10
108 CARRO RP DESLIGADO MUDAR ÓLEO NAS ENGRENAGENS DE REDUÇÃO 30.000 ERP - 0006 2 2 30
108 CARRO RP DESLIGADO CILINDROS PNEUMÁTICOS 12.000 ERP - 0007 1 2 30
108 CARRO CT DESLIGADO CILINDROS PNEUMÁTICOS 500 ECL - 013 CILT - 01.02.0002
108 CARRO RP DESLIGADO MANGAS DE ROLAMENTO LINEAR 12.000 ERP - 0020 1 2 30
108 CARRO CT DESLIGADO MANGAS DE ROLAMENTO LINEAR 500 ECL - 005 CILT - 01.02.0002
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
108 CARRO CT DESLIGADO VERIFICAR E LIMPAS AS VÁLVULAS SOLENOIDES 500 ECL - 014 CILT - 01.02.0002 1 2 5
108 CARRO RP DESLIGADO VÁLVULAS SOLENOIDES x ERP - 0060 1 2 5
108 CARRO RP DESLIGADO CORREIA DENTADA ACIONADA 18.000 ERP - 0010 1 2 60
108 CARRO CT DESLIGADO CORREIA DENTADA 1.500 ECT - 037 CILT - 01.02.0002 1 2 10
108 CARRO CT DESLIGADO ROLOS DE BORRACHA 1.500 CILT - 01.02.0002 1 2 10
108 CARRO RP DESLIGADO ROLOS DE BORRACHA 18.000 ERP - 0012 1 2 60
108 CARRO GR DESLIGADO LUBRIFICAR AS UTILIDADES FORNECIDAS COM BOCAL DE LUBRIFICAÇÃO ** 1.500 EGR - 002 CILT - 01.02.0002 1 2 10
108 CARRO CT DESLIGADO CARRO DE ROLAMENTOS 1.500 CILT - 01.02.0002 1 2 10
108 CARRO RP DESLIGADO CARRO DE ROLAMENTOS 18.000 - 1 5 -
109 GUIA DE COMPRAS CT DESLIGADO CORREIA DENTADA 1.500 ECT - 037 CILT - 01.01.0001 1 2 10
FAMÍLIA DESCRIÇÃO DO GRUPO TAREFA HAB/DESAB DESCRIÇÃO DA TAREFA FREQÜÊNCIA CONDICIONAL ID DO SOP ID DO SOP N° OPERADOR ESPECIALIDADE TEMPO/MÍN. FERRAMENTAS ESPECIAIS
1101 UNIDADE ELÉTRICA CT DESLIGADO VERIFICAR OS CONTATORES RELATIVAMENTE A DESGASTE 1.500 CILT - 70.01.0001 1 2 15
1101 UNIDADE ELÉTRICA CT DESLIGADO DISPOSITIVOS DE EMERGÊNCIA 1.500 CILT - 70.01.0001 1 2 20
1101 UNIDADE ELÉTRICA CL DESLIGADO FILTROS DO COMUTADOR 500 ECL - 002 CILT - 70.01.0001 1 2 15
1101 UNIDADE ELÉTRICA CT DESLIGADO VERIFICAR O FUNCIONAMENTO DO DIFERENCIAL 1.500 ECT - 001 CILT - 70.01.0001 1 2 5
1401 TRANSPORTE CENTRAL CT DESLIGADO VERIFIQUE E TOME A CORRENTE 500 ECT - 002 CILT - 02.01.0001 1 2 10
1401 TRANSPORTE CENTRAL RP DESLIGADO PALETA DE TRANSPORTE x ERP - 0015 1 2 60
1402 MOTOR DE TRANSPORTE CENTRAL CT DESLIGADO VERIFIQUE O NÍVEL DE ÓLEO NAS CAIXAS DE ENGRENAGENS 1.500 CILT - 02.01.0001 1 2 10
1402 MOTOR DE TRANSPORTE CENTRAL CT DESLIGADO FREIO DO MOTOR * 1.500 CILT - 02.01.0001 1 2 10
1402 MOTOR DE TRANSPORTE CENTRAL RP DESLIGADO FREIO DO MOTOR * x ERP - 0004 1 2 60
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
1402 MOTOR DE TRANSPORTE CENTRAL RP DESLIGADO SUBSTITUA ÓLEO EM REDUTORES 30.000 ERP - 0006 2 2 30
1801 MAGAZINE DE PALETES COM BRAÇOS GR DESLIGADO CORRENTE 500 EGR - 015 CILT - 18.01.0001 1 2 10
1801 MAGAZINE DE PALETES COM BRAÇOS RP DESLIGADO CORRENTE x ERP - 0052 CILT - 18.01.0001 1 2 10
1801 MAGAZINE DE PALETES COM BRAÇOS GR DESLIGADO ROLAMENTOS 500 EGR - 014 1 2 60
1801 MAGAZINE DE PALETES COM BRAÇOS CT DESLIGADO ROLAMENTOS 500 ECT - 010 1 2 60
1801 MAGAZINE DE PALETES COM BRAÇOS RP DESLIGADO ROLAMENTOS x ERP - 0051 1 2 60
1802 UNIDADE DE ACIONAMENTO DO EMPURRADOR E DO SISTEMA DE REMOÇÃO DE PASTILHAS CT DESLIGADO VERIFICAR O NÍVEL DE ÓLEO NAS ENGRENAGENS DE REDUÇÃO 1.500 CILT - 18.01.0001 1 2 10
1802 UNIDADE DE ACIONAMENTO DO EMPURRADOR E DO SISTEMA DE REMOÇÃO DE PASTILHAS CT DESLIGADO FREIO DO MOTOR * 1.500 CILT - 18.01.0001 1 2 10
1802 UNIDADE DE ACIONAMENTO DO EMPURRADOR E DO SISTEMA DE REMOÇÃO DE PASTILHAS RP DESLIGADO FREIO DO MOTOR * x ERP - 0004 1 2 60
1802 UNIDADE DE ACIONAMENTO DO EMPURRADOR E DO SISTEMA DE REMOÇÃO DE PASTILHAS RP DESLIGADO SUBSTITUIR O ÓLEO NAS ENGRENAGENS DE REDUÇÃO 30.000 ERP - 0006 2 2 30
1803 VÁLVULA SOLENÓIDE BIESTÁVEL SIMPLES CT DESLIGADO CONTROLAR E LIMPAR AS VÁLVULAS SOLENÓIDE 500 CILT - 18.01.0001 1 2 5
1803 VÁLVULA SOLENÓIDE BIESTÁVEL SIMPLES RP DESLIGADO VÁLVULAS SOLENÓIDE x ERP - 0060 1 2 5
1803 VÁLVULA SOLENÓIDE BIESTÁVEL SIMPLES CL DESLIGADO VÁLVULAS SOLENÓIDE 500 ECL - 014 1 2 5
1803 MAGAZINE DE PALETES COM BRAÇOS CT DESLIGADO CILINDRO DO CARRO 6.000 ECT - 011 1 2 5
4301 TRANSPORTADOR DE CORRENTE CT DESLIGADO VERIFICAÇÃO E TENSIONAMENTO DA CORREIA 500 ECT - 002 CILT - 45.01.0002 1 2 10
4301 TRANSPORTADOR DE CORRENTE GR DESLIGADO VERIFICAÇÃO E TENSIONAMENTO DA CORREIA 6.000 EGR - 016 CILT - 45.01.0002 1 2 10
4301 TRANSPORTADOR DE CORRENTE RP DESLIGADO TRANSPORTADOR DE PALETES 500 ERP - 0117 1 2 60
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
4303 UNIDADE ACIONAMENTO TRANSPORTADOR DE CORRENTE CT DESLIGADO VERIFICAR NÍVEL ÓLEO NAS ENGRENAGENS REDUÇÃO 1.500 CILT - 45.01.0002 1 2 10
4303 UNIDADE ACIONAMENTO TRANSPORTADOR DE CORRENTE CT DESLIGADO FREIO DO MOTOR * 1.500 CILT - 45.01.0002 1 2 10
4303 UNIDADE ACIONAMENTO TRANSPORTADOR DE CORRENTE RP DESLIGADO FREIO DO MOTOR * x ERP - 0004 1 2 60
4303 UNIDADE ACIONAMENTO TRANSPORTADOR DE CORRENTE RP DESLIGADO TROCAR ÓLEO NAS ENGRENAGENS DE REDUÇÃO 30.000 ERP - 0006 2 2 30
4306 FOTOCÉLULA CL DESLIGADO VERIFICAR E LIMPAR AS FOTOCÉLULAS 500 ECL - 002 CILT - 45.01.0002 1 2 5
4306 FOTOCÉLULA CT DESLIGADO VERIFICAR E LIMPAR AS FOTOCÉLULAS 500 ECT - 001 CILT - 45.01.0002 1 2 5
4310 VÁLVULA SOLENÓIDE MONOESTÁVEL ÚNICA CL DESLIGADO VERIFICAR E LIMPAR AS VÁLVULAS SOLENÓIDE 500 ECL - 014 CILT - 45.01.0002 1 2 5
4310 VÁLVULA SOLENÓIDE MONOESTÁVEL ÚNICA RP DESLIGADO VÁLVULAS SOLENÓIDE x ERP - 0060 1 2 5
4401 TRANSPORTADOR DE CORRENTE CT DESLIGADO VERIFICAÇÃO E TENSIONAMENTO DA CORREIA 500 ECT - 002 CILT - 45.01.0002 1 2 10
4401 TRANSPORTADOR DE CORRENTE GR DESLIGADO VERIFICAÇÃO E TENSIONAMENTO DA CORREIA 6.000 EGR - 016 CILT - 45.01.0002 1 2 10
FAMÍLIA DESCRIÇÃO DO GRUPO TAREFA HAB/DESAB DESCRIÇÃO DA TAREFA FREQÜÊNCIA CONDICIONAL ID DO SOP ID DO SOP N° OPERADOR ESPECIALIDADE TEMPO/MÍN. FERRAMENTAS ESPECIAIS
4910 VÁLVULA SOLENÓIDE MONOESTÁVEL ÚNICA CL DESLIGADO VERIFICAR E LIMPAR AS VÁLVULAS SOLENÓIDE 500 ECL - 014 CILT - 45.01.0002 1 2 5
4910 VÁLVULA SOLENÓIDE MONOESTÁVEL ÚNICA RP DESLIGADO VÁLVULAS SOLENÓIDE x ERP - 0060 1 2 5
5001 TRANSPORTADOR DE CORRENTE CT DESLIGADO VERIFICAÇÃO E TENSIONAMENTO DA CORREIA 500 ECT - 002 CILT - 45.01.0002 1 2 10
5001 TRANSPORTADOR DE CORRENTE GR DESLIGADO VERIFICAÇÃO E TENSIONAMENTO DA CORREIA 6.000 EGR - 016 CILT - 45.01.0002 1 2 10
5001 TRANSPORTADOR DE CORRENTE RP DESLIGADO TRANSPORTADOR DE PALETES 500 ERP - 0117 1 2 60
5003 UNIDADE ACIONAMENTO TRANSPORTADOR DE CORRENTE CT DESLIGADO VERIFICAR NÍVEL ÓLEO NAS ENGRENAGENS REDUÇÃO 1.500 CILT - 45.01.0002 1 2 10
5003 UNIDADE ACIONAMENTO TRANSPORTADOR DE CORRENTE CT DESLIGADO FREIO DO MOTOR * 1.500 CILT - 45.01.0002 1 2 10
5003 UNIDADE ACIONAMENTO TRANSPORTADOR DE CORRENTE RP DESLIGADO FREIO DO MOTOR * x ERP - 0004 1 2 60
5003 UNIDADE ACIONAMENTO TRANSPORTADOR DE CORRENTE RP DESLIGADO TROCAR ÓLEO NAS ENGRENAGENS DE REDUÇÃO 30.000 ERP - 0006 2 2 30
You are not allowed to copy, reproduce, publish, distribute, or otherwise use the content of this document in anyway except for the purpose those document was created.
5006 FOTOCÉLULA CL DESLIGADO VERIFICAR E LIMPAR AS FOTOCÉLULAS 500 ECL - 002 CILT - 45.01.0002 1 2 5
5006 FOTOCÉLULA CT DESLIGADO VERIFICAR E LIMPAR AS FOTOCÉLULAS 500 ECT - 001 CILT - 45.01.0002 1 2 5
5010 VÁLVULA SOLENÓIDE MONOESTÁVEL ÚNICA CL DESLIGADO VERIFICAR E LIMPAR AS VÁLVULAS SOLENÓIDE 500 ECL - 014 CILT - 45.01.0002 1 2 5
5010 VÁLVULA SOLENÓIDE MONOESTÁVEL ÚNICA RP DESLIGADO VÁLVULAS SOLENÓIDE x ERP - 0060 1 2 5
6301 MESA ROTATIVA CL DESLIGADO VERIFICAR OS SENSORES 500 ECL - 003 CILT - 63.01.0004 1 2 5
6301 MESA ROTATIVA CT DESLIGADO CORRENTES 500 ECT - 002 CILT - 63.01.0004 1 2 10
6301 MESA ROTATIVA RP DESLIGADO CORRENTES x ERP - 0117 1 2 60
6301 MESA ROTATIVA GR DESLIGADO COROA DE ORIENTAÇÃO 6.000 EGR - 019 CILT - 63.01.0004 1 5 60
6301 MESA ROTATIVA GR DESLIGADO COROA DE ORIENTAÇÃO 500 CILT - 63.01.0004 1 2 15
6301 MESA ROTATIVA GR DESLIGADO GRELHA E RODA DENTADA 6.000 EGR - 018 CILT - 63.01.0004 1 5 20
6301 MESA ROTATIVA RP DESLIGADO GRELHA E RODA DENTADA x ERP - 0087 1 5 60
6301 MESA ROTATIVA RP DESLIGADO MUDAR ÓLEO NAS ENGRENAGENS DE REDUÇÃO 30.000 ERP - 0006 2 2 30
6301 MESA ROTATIVA CT DESLIGADO VERIFICAR NÍVEL DO ÓLEO NAS ENGRENAGENS DE REDUÇÃO 1.500 CILT - 63.01.0004 1 2 10
6301 MESA ROTATIVA CT DESLIGADO TRAVÃO DO MOTOR * 1.500 CILT - 63.01.0004 1 2 10
6301 MESA ROTATIVA RP DESLIGADO TRAVÃO DO MOTOR * x ERP - 0004 1 2 60
6301 MESA ROTATIVA CL DESLIGADO VERIFICAR E LIMPAR AS FOTOCÉLULAS 500 ECL - 002 CILT - 63.01.0004 1 2 5
6301 MESA ROTATIVA CT DESLIGADO VERIFICAR E LIMPAR AS FOTOCÉLULAS 500 ECT - 001 CILT - 63.01.0004 1 2 5
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
Any other use of this document content requires the explicit written permission from Sidel.
SIDEL - Damm Font Salem - Portugal 2019
sidel.com