You are on page 1of 4

FICHE TECHNIQUE N°114 SAPV

04/02/2009 : Creation of the Technical sheet – indice A

How to place the sensor Machine STEP


Object: Explanations regarding How to place the Machine Step
sensor machine correctly.

The Machine STEP sensor (E30.0 for Universal or E12.6 for Serial 2 machine) is the
sensor of reference for the positioning of several other sensors of the machine. A bad
positioning of this sensor would involve a direct defect “Defect control of machine STEP
sensor” or indirect (bad ejection, blowing in the vacuum or different defect…).

1/ Presentation

The positioning of the machine STEP sensor is very important. However, its
positioning depends on the good performance of the Incremental Coder and of the position
of the Initialisation Wheel sensor (E40.5 for Universal or E36.0 for Serial 2 machine).

E40.5 (Universal)
E36.0 (Serial 2)

E30.0 (Universal)
E12.6 (Serial 2)

E30.0 (Universal)
E12.6 (Serial 2)

Page 1 sur 4 RAA 04/02/2009


1/ Position of the Machine STEP sensor on the Universal (E30.0)

The machine STEP sensor E30.0 must be positioned with 5 degrees for all type of
machine. The sensor must be positioned on the rising face of station 1:
Page WHEEL (1)/ BLOWING (2), bring the station 1 to 5 degrees (3).

1/ Position of the Machine STEP sensor on the Serial 2 (E12.6)

The position of the STEP machine sensor E12.6 is different according to the
type of machine PM, MM, GM, and TM:

Page 2 sur 4 RAA 04/02/2009


The machine STEP sensor E12.6 must be positioned according to the table above:
ALARMS page/ PLC card malfunction visualization (1)/ PLC Information (2)

Page 3 sur 4 RAA 04/02/2009


3

The value in Encoder Value, as in degree of station 1 will be visible on this page (3).

Good Luck !

Page 4 sur 4 RAA 04/02/2009