MPG- 60 KVA-PK@50Hz

60 kVA / 48 kW
POWERED by Perkins

DIESEL GENERATING SET 440/254V, 415/240V, 400/230V, 380/220V - 50 Hz

MODEL MPG-60kVA-PK@50 Hz
kVA 66
Standby
Power kW 52.8
Pf. 0.8 kVA 60
Prime
kW 48

Standby : Power available in the event of a main power network failure up to a maximum of 500 hr. / year of which 300 hours may be run continiously, load factor maybe up to 100 % of standby power.
No overload is permitted.
Prime : Power available at variable load with a load factor not exceeding 80% of rated power. Overload of 10% is permitted for 1 hour every 12 hours.

High quality, reliable and complete power unit


Compact design
Easy start and maintenance possibility
Every generating set is subject to a comprehensive test program which includes full load testing, checking and provision
of all control and safety shut down functions testing
Fully engineered with a wide range of options and accessories: Canopy, sound proof canopy and on - road trailer

Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.

www.mpg.com.lb
ENGINE

Perkins
Model 1103A-33TG2

Engine Power Output kWm 60.5


at rated rpm HP 81.1
Aspiration and Cooling Natural
Total Displacement Litre 3.3
No. of Cylinders and Build 3-.Inline
Engine Speed rpm 1500
Bore and Stroke mmxmm 105X127
Compression Ratio 17.25:1
Governor Mechanical
Fuel Consumption at full load L/hr 13.9
Fuel Tank Capacity Litre 8 Hours
Oil Capacity Litre 8.3
Coolant Capacity Litre 10.2
Radiator Cooling Air m³/min 89
Air Intake – Engine m³/min 3.9
Exhaust Gas Flow m³/min 10.4

Heavy duty Perkins diesel engine Cooling radiator and fan


Four stroke, water, cooled, turbo charged Starter battery (miantenance free) including Rack and Cables
Direct injection fuel system Flexible fuel connection hoses and manual oil sump drain valve
Mechanical Governor system Industrial capacity exhaust silencer and steel bellows
12/24 V D.C. starter and charge alternator Jacket water heater(at automatic models)
Replaceable fuel filter, oil filter and dry element air filter Operation manuals and circuit diagram documents

ALTERNATOR

Design Brushless single bearing, revolving field


Stator 2/3 pitch
Rotor Single bearing, flexible disc
Insulation System Class H
Standard Temperature Rise 125 - 163°C Continuous
Exciter Type Self Excited
Phase Rotation A (U), B (V), C (W)
Alternator Cooling Direct drive centrifugal blower fan
AC Waveform Total Harmonic Distortion No load < 1.5%. Non distorting balanced linear load < 5%
Telephone Influence Factor (TIF) <50 per NEMA MG1 - 22.43
Telephone Harmonic Factor (THF) <2%

Brushless, single bearing system, flexible disc, 4 poles Impregnation with tropicalised epoxy varnish
Insulation class H Solid state Automatic Voltage Regulator
Standard degree of protection IP21 (*IP22/IP23 is available) Stator winding with 2/3 pitch for improved harmonics
Self-exciting and self-regulating

www.mpg.com.lb
CONTROL SYSTEM

Control supervision and protection panel is mounted on the genset base frame. The control panel varies depending
on requirment, in general Meico power generatorsare equipped with DSE 6010 MKII.
The main features for DSE 6010 MKII are as follows:

KEY BENEFITS KEY FEATURES


• Hours counter provides accurate • Large back-lit icon display • CAN, MPU and alternator speed sensing in one variant
information for monitoring and • Heated display option available • 3 engine maintenance alarms
maintenance periods • Fully configurable via the fascia • Engine speed protection
• User-friendly set-up and button or PC using USB • Engine hours counter
layout for ease of use communication • Engine pre-heat
• Multiple parameters are • Efficient power save mode • Engine run-time scheduler
monitored simultaneously which • 3 phase generator sensing • Engine idle control for
are clearly displayed on a large • 3 phase mains (utility) sensing starting &stopping
back-lit icon display (DSE6620 only) • Fuel pump control
• The module can be configured • Generator/load power • Real time clock
to suit a wide range of monitoring (kW, kV A, kV Ar, pf ) options available
applications • Generator overload protection • Battery voltage
• Compatible with a wide range • Generator/load current monitoring
of CAN engines, including tier 4 monitoring and protection • Start on low battery
engine support • Breaker control via fascia voltage
• Uses DSE Configuration Suite buttons • Configurable remote
PC Software for simplified • Fuel and start outputs start input
configuration (configurable when using CAN) • 1 alternative configuration
• Licence-free PC software • 4 configurable DC outputs • Comprehensive warning,
• IP65 rating (with optional • 4 configurable analogue/digital electrical trip or shutdown
gasket) offers increased inputs protection upon fault condition
resistance to water ingress • 6 configurable digital inputs • LCD and LED alarm indication
• Configurable staged loading • Configurable event log (50)
outputs

Also Gensets can be equipped with different control panels depending on usage such as:
DSE 6610: Basic Autostart operation with stand alone application
DSE 7310: advanced Autostart operation with high protections
DSE 7320: advanced auto mains failure operation with high protection
DSE 8610: for synchronization application/solution

OPTIONAL EQUIPMENTS

Diesel Engine Panel Accessories


Oil heater Charge ammeter Bulk fuel tank
Transfer Switch 3Pole Automatic filling system
Alternator Transfer Switch 4 Pole Fuel - water separator filter
3/4 Pole Output Circuit Breaker Earth Fault, single set Low fuel level alarm
Anti - condensation Heater Residential silencer
Enclosure or sound proof canopy
Trailer
Manual oil drain pump
Tool kit for maintenance

www.mpg.com.lb
CHASSIS

The complete gen-set is mounted as whole on a heavy-duty fabricated, steel base frame
Anti-vibration pads are fixed between the engine/ alternator feet and the base frame
Base frame design incorporates an integral fuel tank (Up to 750 kVA)
The generating set can be lifted or carefully pushed / pulled by the base frame
Dial type fuel gauge and drain plug on the fuel tank
Forklift pockets within base frame (up to 500kVA)

DIMENSIONS

OPEN TYPE
155X80X140
DIMENSIONS (LxWxH) cm

DRY WEIGHT kg 884

SOUND ATTENUATED TYPE 75dBA @ 3m in open space


DIMENSIONS (LxWxH) cm 240X96X130

DRY WEIGHT kg 1225

CANOPY

All canopy parts are designed with modular principles

Doors on each side

All metal canopy parts are powder coated

Exhaust silencer is protected against environment influences

Easy lifting and moving

Easy maintenance and operation

Head Office: Bechara El Khoury Blvd. Bechara El Khoury Tower, 9th Flr. Factory: Jounblat Street - Sibline - Chouf - Meico Bldg.
Tel. 01 664 800/1/2/3, Fax. 01 664 804. P.O.Box: 155.521, Beirut, Lebanon Tel. (07) 970680/1/2, Fax. (07) 970683, Mobile. (03) 463030
Saudi Arabia Branch
Riyadh Tel. 011-2912848; Jeddah Tel. 012-6132964 Email. info@mpg.com.lb, www.mpg.com.lb, www.meicopowergenerators.com