NO LOAD AND BLOCKED ROTOR TEST ON 1Ф INDUCTION MOTOR

AIM:
To draw the equivalent circuit of a single phase induction motor by conducting the no-
load and blocked rotor test.

APPARATUS REQUIRED:

S.No Name of Range Type Qty.


Apparatus
1 Voltmeter (0-300)V MI 1
(0-150)V MI 1
2 Ammeter (0-10)A MI 1
(0-2)A MI 1
3 Wattmeter (330V,10A) UPF 1
(300V,5A) LPF 1
4 Connecting As reqd.
wires

FUSE RATING:

125% of 7.6A=10A

PRECAUTIONS:

NO LOAD TEST:

 Initially TPST Switch is kept open.


 Autotransformer is kept at minimum potential position.
 The machines must be started on no load.
BLOCKED ROTOR TEST:

 Initially the TPST Switch is kept open.


 Autotransformer is kept at minimum potential position.
 The machine must be started at full load(blocked rotor).

PROCEDURE:

NO LOAD TEST:

1. Connections are given as per the circuit diagram.


2. Precautions are observed and the motor is started at no load.
3. Autotransformer is varied to have a rated voltage applied.

BLOCKED ROTOR TEST:

1. Connections are given as per the circuit diagram.


2. Precautions are observed and motor is started on full load or blocked rotor position.
3. Autotransformer is varied to have rated current flowing in motor.
4. Meter readings are the noted.

FORMULAE-

NO LOAD TEST-

 cos Ф = Wo/VoIo
 Iw = Io cosФ
 Im = Io sin Ф
 Ro = Vo/Iw
 Xo = Vo/Im

BLOCKED ROTOR TEST-

Z01= Vsc/Isc Ω
R01 = Wsc/Isc2 Ω
X01 = √(Z012 – R012) Ω
TABULATION

NO LOAD TEST-

S.No. Vo(volts) Io(amps) Wo(watts)


m.f Observed Acual

BLOCKED ROTOR TEST-

S.No. Vsc(volts) Isc(amps) Wsc(watts)


m.f Observed Actual

RESULT-

Thus the no load and blocked rotor test on the single phase induction motor has been conducted
and the equivalent circuit has been drawn.