You are on page 1of 8

Gas capacity constraint

CALCULO DE SEPARADOR BIFASICO d Leff Lss


16 3.44 4.77
GIVEN: Z= 0.84 20 2.75 4.42
FLOW RATE 10 MMSCFD 24 2.29 4.29
SP. GRAV. 0.6 28 1.97 4.30
BoPD 8000 36 1.53 4.53
API 40 30 1.83 4.33
P op 1000 PSIA Liquid capacity constraint
Top 60 F
520 R min in ft
CALCULATE K tr d Leff
SP/T = 1.153846154 1 24 19.84
K= 0.3 1 30 12.70
1 36 8.82
GAS CAP. CONSTRAINT 1 42 6.48
2 24 39.68
EC 4.6 dLeff= 55.0368 2 30 25.40
2 36 17.64
Compute Lss for various d 2 42 12.96
3 24 59.52
3 30 38.10
Lss gas 3 36 26.46
3 42 19.44
sandra-4000 4 24 79.37
arturo 6000 4 30 50.79
angel 8000 4 36 35.27
anagm 10000 4 42 25.92
gas cap liq cap
4.77 4.59
4.42 3.67
4.29 3.06
4.30 2.62
4.53 2.04 EQUIPO 3
4.33 2.45 Diana Sanchez
3---4 Ramses Suarez
Raul Cardona
ft Angel Peña
Lss Rs(12xLss/d) Angel Ramon
26.46 13.23
16.93 6.77
11.76 3.92 ok
8.64 2.47
52.91 26.46
33.86 13.54
23.52 7.84
17.28 4.94
79.37 39.68
50.79 20.32
35.27 11.76
25.92 7.40
105.82 52.91
67.72 27.09
47.03 15.68
34.55 9.87
Chart Title
160

140 15.68

120 47.03

13.54
100
33.86
13.23
80
35.27
26.46

60 25.40

19.84
40 36
30
24
20

tr d Leff Lss Rs(12xLss/d)


20

tr d Leff Lss Rs(12xLss/d)


15.68

47.03

35.27

36

You might also like