You are on page 1of 1

REPORTE DE RESULTADOS DE TUBERIAS - SISTEMA N° 02

PROYECTO: "MEJORAMIENTO, AMPLIACION DEL SISTEMA DE AGUA POTABLE Y SANEAMIENTO BASICO EN EL CENTRO POBLADO SAN JUAN
QUIHUARES DISTRITO DE RONDOCAN, PROVINCIA DE ACOMAYO - CUSCO"

DIAMETER HAZEN VELOCITY


ID LABEL LENGTH START NODE STOP NODE MATERIAL FLOW (l/s)
(mm) WILLIAMS C (m/s)

53 P-1 17 T-1 J-1 54.2 PVC 150 0.189625 0.082188


54 P-2 2 J-1 J-2 54.2 PVC 150 0.180375 0.078179
55 P-3 107 J-2 J-3 54.2 PVC 150 0.178062 0.077176
56 P-4 99 J-3 J-4 43.4 PVC 150 0.078625 0.053149
57 P-5 49 J-4 J-5 22.9 PVC 150 0.02775 0.067376
59 P-7 142 J-6 J-7 22.9 PVC 150 0.004625 0.011229
60 P-8 88 J-6 J-8 22.9 PVC 150 0.00925 0.022459
61 P-9 45 J-8 J-9 22.9 PVC 150 0.002313 0.005615
63 P-11 62 J-10 J-11 22.9 PVC 150 0.002313 0.005615
65 P-13 3 J-12 J-13 22.9 PVC 150 0.0185 0.044917
66 P-14 109 J-13 J-14 22.9 PVC 150 0.004222 0.010252
67 P-15 10 J-14 J-15 22.9 PVC 150 0.00191 0.004637
68 P-16 47 J-15 J-16 22.9 PVC 150 0.00191 0.004637
69 P-17 88 J-13 J-16 22.9 PVC 150 0.005028 0.012207
70 P-18 55 J-12 J-17 29.4 PVC 150 0.074 0.109005
71 P-19 97 J-17 J-18 29.4 PVC 150 0.062437 0.091973
72 P-20 115 J-18 J-19 29.4 PVC 150 0.013875 0.020438
73 P-21 134 J-18 J-20 22.9 PVC 150 0.011563 0.028073
74 P-22 173 J-1 J-21 22.9 PVC 150 0.004625 0.011229
76 P-23 47 J-4 PRV-1 29.4 PVC 150 0.02775 0.040877
77 P-24 200 PRV-1 J-10 29.4 PVC 150 0.02775 0.040877
79 P-25 28 J-5 PRV-2 22.9 PVC 150 0.025438 0.061761
80 P-26 77 PRV-2 J-6 22.9 PVC 150 0.025438 0.061761
82 P-27 10 J-3 PRV-3 43.4 PVC 150 0.094812 0.064091
83 P-28 33 PRV-3 J-12 43.4 PVC 150 0.094812 0.064091

You might also like