Design of Intake well

S.No. Data Value Unit Remarks


1 River Bed Level 219.4 m
2 Lowest Water Level of River 222.2 m
3 Highest Flood Level River 232.1 m
4 Pump Floor Level of Intake Well 233.1 m
5 Pump Discharge Pipe Level 234.1 m Depends on pump dimension
6 Roof level of pump house 239.1 m
7 Maximum Demand 12.4 MLD
8 Number of working Hour 16.0 Hr
9 Design Intake well for Volume
10 Design of Wet well
11 Design Discharege for 16 hr operation 12.4 MLD
12 12.89 m3/min
13 Considering detention time 20 mins
14 Volume of well required 257.81 m3
15 Considering depth of intake well below floor level 10 m
16 Surface area of wet required 25.78 m2
17 Diameter of well required 5.73 m
18 Diameter of well provided 6 m
19 Providing a silt pocket below required depth 0.5 m
20 Bottom level of intake well 208.9 m
21 Foundation level of intake well 207.4 m Assumed depth of foundation 1.5 m
22 Total Height of intake well 24.2 m
23 Size of pipe connected in river
24 Total disharge 12.89 m3/min
25 Number of discharge pipe 1 nos.
26 Design velocity 1.2 m/sec
27 Requried area of pipe 0.18 m2
28 Dia of pipe required 0.48 m
29 Dia of pipe provided 0.5 m
30 Level of pipe to be connected in the river with coarse screen and gates/vavle
31 Total three pipe will be connected
32 One below LWL
33 Two between LWL and HFL
34 Pump Design at intake
35 Deisgn Discharge 0.215 m3/sec
36 Total number of working pumps provided 2 nos.
37 Capacity of pump required 386.719 m3/hr VT Pumps
38 Diameter of the main 0.4 m
39 Length of rising main 7633.5 m 5% increased
40 Type of pipe DI
41 Pump head requried 27.5 m