You are on page 1of 1

1.

A kind of diagram that is used in designing or troubleshooting electrical installation control equipment so
arranged to facilitate tracing of the circuit?
2. These are sheet metal troughs with hinged or removable covers for housing and protecting electrical wires and
cables in which conductors are laid in place.
3. Which of the following electrical parameters apply or labelled to all kind of switches?
4. Which of the following electrical parameters apply to an incandescent bulb are?
5. When tightening a terminal screw connection with the splice wire, the end of the splice wire should pass around
the screw in the same direction as the screw is turned, so that _______________.
6. One most advantage using rubber insulation tape in splice is _______________.
7. A part providing an appropriate degree protection of equipment against contains external influences and
defined degree of protection against contacts with live parts any direction.
8. Locknut, bushing and connectors are called electrical ____________.
9. Why it necessary to use torque wrench is tightening bolted joints of copper bus bars inside bus ducts and bus
ways?
10. What is the commonly used conduit in Service Entrance?
11. What are the types of fitting commonly used for exposed conduit support?
12. What do you call a fitting resembling a pipe or box with a removable cover access to electric conduit?
13. When raceways are exposed to widely different temperature it should be ____________.
14. The box use for convenience outlet is
15. Before adding to or altering an installation, you must ensure that _______________.
16. A mechanical connector that is crimped unto a conductor for both splice and termination is known as.
17. What will you do if the load schedule reflects a 20AT/2.0 mm2 lighting branch circuit of which circuit is
overrated?
18. Commonly used adhesive materials for joining of PVC conduit
19. The size of circuit breaker to be used in 40 A motor full load current is.
20. A live duplex wire can be de-energized quickly and safely by cutting ___________.
21. The selection requirements for circuit breaker are.
22. When measuring load current, an ammeter is connected __________.
23. The material used in long length of busbar joints to give allowance for thermal expansion is ____________.
24. When measuring load resistance, the ohmmeter is connected __________.
25. The current is directly proportional to the voltage and inversely proportional to resistance.
26. What is the ampacity of 8.0 mm2 THW wires?
27. What amount of current will be drawn by incandescent bulb connected to a 115-volt circuit if its resistance is
264.5 ohms?
28. When measuring ballast resistance if it is defective or good, it is necessary that the source
29. A circuit breaker is an electrical protective device which _________.
30. It is the connection between the grounded circuit conductor and the equipment grounding conductor at the
service?
31. The 24 hours protection for home and commercial building to monitor and access the video any time anywhere
on this device.
32. Which of the following is an output device?
33. The Auxiliary device of CCTV that monitor the motion daily.
34. The technical term for the type THW wires used mostly is industrial wirings is.
35. Which of the following is an input device?
36. When skinning a small wire, the insulation should be “pencil down” rather that cut square to ___________.
37. A part of Auxiliary device that capture live vents and save as video files.
38. The minimum size of conduit commonly used in laying- out of Auxiliary devices.
39. An electricians should always have his tools in good working condition, the most important reason being is ____.
40. What type of hand tools commonly used in boring of ½” diameter hole in a panel board?
41. What are the types of fitting commonly used for tightening between the boxes and the conduit?
42. Part of Auxiliary System that set the motion-trigger action individually for each camera?
43. The box use for typical switches?