The new ECS on the

747-8 takes advantage


of new technology to
offer greater capacity,
increased efficiency, and
improved maintainability.

18
aer o q uar t er ly    qt r_01 | 12
Inside the 747-8
New Environmental
Control System
The Boeing 747-8 includes a new environmental control system (ECS) that integrates the
air supply control system and the cabin air-conditioning and temperature control system.

By André Brasseur, Service Engineer;


Will Leppert, Service Engineer; and
Alexis Pradille, Service Engineer, Liebherr Technical Services

The 747-8 ECS increases cooling capacity increased reliability, and reduced mainte­ system, allowing for increased efficiency
and improves performance and main­ nance compared to earlier technology. of bleed air and a reduction in bleed air
tainability, while providing a common 747 Changes to the air supply control system penalties. That, in conjunction with the
platform with simplified flight deck interfaces. (ASCS) and cabin air-conditioning and improved maintainability achieved through
The system’s architecture integrates temperature control system (CACTCS) the placement of LRUs and LRU com­
more functions in fewer line replaceable combine to provide the 747-8 greater ponents, helps reduce operating and
units (LRUs) to maximize efficiency and cooling capacity as well. maintenance costs.
reliability and to simplify troubleshooting. The 747-8 ECS uses new technologies Other key improvements in the new
This article provides an overview of the to improve performance. These include an ECS include an advanced new bleed
design of the 747-8 ECS and in-service integrated air system controller (IASC) and system and true subfreezing packs.
support. the associated software. In addition, the
system uses high-pressure water separa­
Advanced bleed system
tion to dry out the air within the air cycle
Performance and reliability
machine upstream of turbine section input,
The 747-8 airplane is powered by General
as well as pressure sensors to provide
A robust ECS is important for cabin safety Electric GENX-2B engines. The engine
input to the IASC for icing control.
and comfort. The 747-8 uses an ECS that bleed systems supply air from the engine
Combined, these technologies help
offers digital control, lighter weight, compressor. There are four identical engine
improve the efficiency and reliability of the
19
W W W . boeing. c om/ co m m e r c ia l / a e ro m a g a zine
The air-conditioning pack incorporates a water extraction
loop within the pack to extract water and avoid ice
formation at the ACM turbine outlet. This is accomplished
by routing the air appropriately within the pack; water
separation is accomplished within the pack itself as part
of the air-conditioning process.

bleed systems per airplane with indepen­ 747-8 subfreezing pack overcome environmental limitations include
dent control and indication for each system the use of:
(see fig. 1). The 747-8 air-conditioning pack has several
■■ High-pressure water separation, which
The air temperature and air pressure are key features that allow it to be classified as
mitigates the buildup of ice within the air
regulated before being delivered to airplane a true subfreezing pack, which will operate
cycle machine (ACM).
systems. The bleed air is used for CACTCS, to temperatures below the freezing point
engine anti-ice, wing anti-ice, the hydraulic of water at all altitudes (see fig. 2). While ■■ Integrated pack control features that
air-driven pump, the leading-edge flap drive earlier air-conditioning packs can drive mitigate ice formation within the air-
unit, the nitrogen generation system, aft subfreezing during all conditions, there are conditioning pack.
cargo heat, total air temperature probe limitations that need to be placed upon the ■■ A compact mixing section at the turbine
aspiration, and hydraulic reservoir pressur­ system due to the operating environment outlet of the pack, which allows recir­
ization. All four engine bleed systems are and the technology implemented within culated air from the airplane ambient
connected by a common manifold. the system. As a result, below 25,000 feet environment to be mixed directly with
Technological advancements enabled (7,620 meters), where environmental icing pack outlet air prior to implementing
Boeing to make several improvements is a factor, the pack turbine discharge outlet discharge temperature limitations.
to the bleed system on the 747-8. These (i.e., pack outlet) is limited to approximately
High-pressure water separation. The air-
improvements include: 35 degrees F (1.67 degrees C) prior to
conditioning pack incorporates a water
mixing of recirculated air in the main dis­
■■ New digital bleed. The system has no extraction loop within the pack to extract
tribution plenum. At cruise, where icing
mechanical position switches and water and avoid ice formation at the ACM
concerns are not a critical issue for opera­
reduced use and consolidation of sensors. turbine outlet. This is accomplished by
tion, many packs do drive subfreezing as
routing the air appropriately within the
■■ No remote valve controllers. The torque conditions warrant.
pack; water separation is accomplished
motor and solenoid are built into the The 747-8 pack incorporates technology
within the pack itself as part of the air-
valve design, allowing for easier trouble­ that enables it to function as a subfreezing
conditioning process.
shooting and improved fault isolation. conditioned air supply during all phases of
Air that has been heated in the ACM
operation, both on the ground and in flight.
■■ Fewer servo/sense lines. This increases compressor section is first cooled by the
Key factors that enable this technology to
system reliability. main heat exchanger. The air is then further

20
aer o q uar t er ly    qt r_01 | 12
Figure 1: 747-8 engine bleed system
The system schematic (top) and component locations (bottom) in the 747-8 engine bleed system.

1 Delta Pressure Sensor


2 Engine Anti-Ice Valve
3 Fan Air Modulating Valve Fan
4 High-Pressure Shutoff Valve To Inlet Lip
5 Intermediate Pressure
Check Valve
2
Outboard Inboard
6 Intermediate Pressure Sensor
Strut Only Strut Only
7 Bleed Manifold Pressure Sensor
4th Stage 5
8 Pressure Regulating Valve Port 6

9 Over Pressure Valve 3

10 Manifold Temperature Sensor 10 10

11 Precooler 8 11 9

To
Airframe
10th Stage Ducts
4
Port
1

Starter
7

3 2

11

8 5

21
W W W . boeing. c om/ co m m e r c ia l / a e ro m a g a zine
Figure 2A: 747-400 air-conditioning pack system
Compare this 747-400 to the 747-8 air-conditioning pack system shown in figure 2B. Note the locations of the respective water separator/extractor systems as
well as the pack temperature sensor relative to the mixer discharge temperature sensor.

To Conditioned
Ram Outlet Air
Air Plenum
1 Compressor Bypass Check Valve 1 2 3 4 5 6
2 Water Collector
3 Secondary Heat Exchanger
4 Ram Air Exit
5 Primary Heat Exchanger 16
6 Pack Flow Control
and Shutoff Valve
15
7 Cooling Air Check Valve
8 Fan
9 Turbine Bypass Valve 14 From Pneumatic
10 Turbine System
11 Compressor
12 Ram Air Inlet 13
13 Air Cycle Machine
14 Water Separator
15 Pack Temperature Sensor
12
16 Overtemperature Switch

11 10 9 8 7

cooled below its dew point as it travels injectors to increase cooling efficiency of The ability to adjust this temperature
through the condenser section. Within the the ram air subsystem. This functionality is in conjunction with the necessary compo­
condenser section, water droplets are particularly critical for ground operations. nents and controls to sense flow restrictions
formed, allowing water to be removed associated with ice buildup within the ACM
Integrated pack control. The pack temper­
from the system. enables the system to avoid and control ice
ature is modulated using the ram air door
The water extractor then removes the formation within the condenser. In addition,
actuators (RADAs) and the temperature
water particles from the high pressure in the the ability to control the temperature within
control valve (TCV). The RADAs modulate
ACM by creating a vortex, which forces this stage of the ACM operation increases
the ram air flow to regulate ACM compres­
the water to collect at the walls of the unit. the efficiency and performance of the high-
sor outlet temperature.
The dried air then passes into the reheater, pressure water extraction process.
The TCV position controls the amount of
where the air is again raised to the temper­ The components and technology
hot air that bypasses the turbine, allowing it
a­ture of the air entering the water extraction provided within the ACM allow the unit to
to adjust the ACM speed and subsequent
loop before entering the ACM turbine inlet. function as a cooling unit with increased
pack discharge temperature downstream
The water that is removed is then capacity due to the use of a “defrost cycle,”
of the water extractor prior to flow injection
injected into the ram heat exchanger as required to mitigate the presence of ice.
into the ACM turbine section.
cooling air inlet by means of the water This protects the pack against the damage

22
aer o q uar t er ly    qt r_01 | 12
Figure 2B: 747-8 air-conditioning pack
A diagram of the 747-8 air-conditioning pack system.

20
1 Compressor Discharge
Temperature Sensor
2 Reheater Ram Air Inlet From Trim
3 Condensor To Distribution
11
4 Compact Mixer
5 Water Extractor
From Flow
17
Control 1 To Distribution
6 Pack Temperature Sensor Valve 10
2 Manifold
18
7 Air Cycle Machine
8 Temperature Control Valve To Ram 4
3
Air Exit 9 12
9 Plenum
16 15 From
10 Ram Heat Exchanger Recirculation
11 Water Injector(s) 5 6
21
19 7
12 Mixed Discharge
Temperature Sensor 13
From Cabin
Cooling Pack 8
13 Pack Discharge Pressure Sensor
14 Integrated Air System Controller
15 Turbine 14

16 Compressor Pack System


17 Main Heat Exchanger
18 Primary Heat Exchanger
19 Ram Air Exit Actuator
20 Ram Air Inlet Actuator
21 Fan
4 3 2 1

5 6 7 8 9 10 17 18

23
W W W . boeing. c om/ co m m e r c ia l / a e ro m a g a zine
Figure 3: 747-400 and 747-8 interface similarity 
Flight deck controls for the new environmental control system are very similar to those on the 747-400, easing the transition to the new airplane for flight crews.

Cabin air-conditioning and temperature control system panel:


747-400 Freighter 747-8 Freighter

FLT FAN FLT TE MP FWD MAIN AFT


FAN TEMP FWD MAIN AFT DE CK DE CK
DECK AUTO AUTO DECK AUTO AUTO AUTO AUTO
TE MP
TEMP
ON
ON

C MAN W C MAN W C MAN W C MAN W C MAN W C M AN W


ALTN VE NT
FWD LOWER AFT FWD LOWE R AFT
ZONE RST TRIM AIR AUTO LOBE AUTO AUTO LOB E AUTO
TEMP ON CLOSE OPE N TE MP
ON
SYS INOP
FAULT

EQUIP COOLING C W C MAN W E QUIP COOLING C W C OFF W


MAN NORM OFF
NORM HI FLOW PACK RST AFT CARGO HT HI FLOW PACK RST L- TRIM AI R -R
STBY OVRD STBY OVRD

ON ON ON ON ON

SYS TEMP SYS


FAULT A FAULT A

Air supply control system panel:


747-400 747-8

1 PACKS 2 PACKS 3 1 PACKS 2 PACKS 3


NORM NORM NORM
OFF A OFF A OFF A
B B B
OFF OFF OFF
L ISLN R ISLN L ISLN R ISLN

VALVE W C VALVE

WING WING
TAI TAI WAI WA I
APU APU
SYS SYS SYS SYS
ON
FAULT FAULT FAULT FAULT

VALVE 1 2 VALVE 3 4
1 2 3 4

ON ON ON ON
ENGINE E NGINE
BLEED OFF OFF OFF OFF
OFF OFF OFF OFF B LE E D

Cabin air-conditioning and temperature control system panel:


747-400 Passenger 747-8 Passenger

PASS TEMP FLT DECK CARGO TEMP PASS TEMP FLT DECK ALT CARGO TEMP
AUTO AUTO AUTO AUTO AUTO AUTO

C W C W C W C W C W C W
ALTN MAN MAN ALTN MAN OFF
ALTN VENT
ZONE RST TRIM AIR UPR-RECIRC-LWR AFT CARGO HT UPPER - RECIRC -LWR

ON ON ON ON ON ON ON
CLOSE OPEN
SYS TEMP INOP
FAULT

EQUIP COOLING EQUIP COOLING


NORM HI FLOW PACK RST GASPER HUMID NORM HI FLOW PACK RST L - TRIM AIR -R
STBY OVRD STBY OVRD
ON ON ON ON ON ON

SYS SYS
FAULT A FAULT A

24
aer o q uar t er ly    qt r_01 | 12
that could be caused by ice buildup within In this way, the compact mixer allows requests will be coordinated closely
the ACM. Because of this capability, the the turbine discharge temperature to float with Liebherr-Aerospace, the supplier
747-8 pack can safely operate below well below freezing to directly address of key components in the system. The
freezing and provide increased cooling the air-conditioning load imposed by the Liebherr-Aerospace Customer Support &
capacity during all operating conditions. recirculated air from the main cabin zones Services network deployed for the 747-8
and allows the pack to provide more of its includes spares, repair, and field support
Compact mixing section. The pack
available capacity as a result. For example, services stationed in China, France,
discharge air from the ACM turbine section
during hot-day ground conditions with very Germany, Russia, Singapore, United
is then sent to the compact mixer prior to
warm recirculated air injection, the pack has Arab Emirates, and the United States.
distribution into the main airplane cabin
the capacity to drive cold, as necessary, to A Liebherr-Aerospace field service repre­
area. The compact mixer ensures the
maintain a temperature above 37 degrees F sentative will work closely with customers.
efficient mixing of outside air delivered by
(3 degrees C) at the discharge downstream Liebherr will also be available to help
the ACM with recirculated air from the main
of the compact mixer section. respond to in-service requests. Customers
cabin zones. Consequently, rather than
can send support service requests to
controlling the pack discharge temperature
Boeing or contact Liebherr’s field service
downstream of the turbine directly, the Familiar flight deck interfaces
engineering staff directly.
compact mixer outlet temperature is con­
trolled according to the following schedule, The monitoring and control functions
which is strictly based on altitude: of ASCS and CACTCS are integrated in Summary
centralized software that is fit into three
■■ From 0 to 25,000 feet (0 to 7,620 meters),
interchangeable digital controllers. System The new ECS on the 747-8 takes advan­tage
control the minimum outlet temperature
control has been managed to keep a of new technology to offer greater capacity,
to 37 degrees F (3 degrees C).
flight deck interface similar to the 747-400 increased efficiency, and improved main­
■■ From 25,000 to 30,000 feet (7,620 to
(see fig. 3). tain­ability while maintaining a flight deck
9,144 meters), control the minimum
interface similar to that on the 747-400.
outlet temperature linearly from
In-service requests will be coordinated
37 degrees F (3 degrees C) at New approach to in-service
requests
closely with Liebherr-Aerospace, the
25,000 feet (7,620 meters) to
supplier of key components in the system.
29 degrees F (-2 degrees C) at
For more information, please contact
30,000 feet (9,144 meters). The new 747-8 ECS also represents a
André Brasseur at andre.g.brasseur@
■■ Above 30,000 feet (9,144 meters), new way of managing in-service requests
boeing.com. 
control the minimum outlet temperature designed to provide operators with the
to 29 degrees F (-2 degrees C). fastest possible response. In-service

25
W W W . boeing. c om/ co m m e r c ia l / a e ro m a g a zine