Kontraktor
PT Mutiara Indah Construction
CV Arum Abadi
PLANT TARAHAN
DATA, PENGUJIAN DAN REFERENSI
MATERIAL UNTUK BETON
I MATERIAL DAN PENGUJIAN UNTUK BETON
A. MATERIAL
1. Semen
2. Slag Powder
a. Jenis Slag : Ground Granulated Blast Furnace Slag dari PT Krakatau Strell
3. Air
c. Spesifikasi : ASTM. C 33
d. Pengujian Meliputi : 1 Test method for Organic Impurities in Fine Aggregate for
Concrete (ASTM.C 40)
MATERIAL
WATER Pottable and not contain more than 0.1 % of chloride ions. 1
Teguh Aji P.
Quality Control Dept.
CV ARUM ABADI
Plant Tarahan
Jl Bakauheni Raya KM 15
MATERIAL
WATER Pottable and not contain more than 0.1 % of chloride ions. 1
Teguh Aji P.
Quality Control Dept.
KONTROL PROSES PRODUKSI
II. Kontrol Proses Produksi
Slump test di Plant : ASTM. C 143 (Test Methods for Slump of Hydraulic Cement Concrete)
Test Yield : ASTM. C 138 (Test Method for Unit Weight Yield, and Air Content
(Gravimetric) of Concrete.
Slump Test di Proyek : ASTM. C 143 (Test Methods for Slump of Hydraulic Cement Concrete)
MATERIAL QUALITY CONTROL FLOWCHART
START
- QUARRY VOLUME
- GRADATION MIX TRIAL MIX JOB MIX
ASTM C136-93
- SPECIFIC GRAVITY/ ASTM C 128-93 DESIGN FORMULA
ABSORPTION
- SILT CONTENT ASTM C 177-90 ACI 211.1-89 - MOIST CONTENT ASTM C566-89 ACI 211.1-89
- ORGANIC IMPURITY ASTM C 40-92 ACI 211.-89 - SLUMP TEST ASTM C143-90a ACI 211.1-81
- SOUNDNESS TEST ASTM C 88-90 DOE - UNIT WEIGHT ASTM C138-92 DOE
- SETTING TIME ASTM C403-92
- VISUAL CONDITION ACI 311.4R-88
- STRENGTH ASTM C39-93a
COARSE AGGREGATE
- QUARRY VOLUME
- GRADATION ASTM C136-93
- SPECIFIC GRAVITY/ ASTM C 127-88
ABSORPTION
- SILT CONTENT
BATCHING PLANT PRODUCTION
ASTM C 177-90
- ABRASION TEST ASTM C 131-89
- SOUNDNESS TEST ASTM C 88-90 - AGGREGATE & CEMENT SCALE CONTROL ASTM C94-94
- WATER & ADDITIVE FLOW CONTROL ASTM C94-94
- AGGREGATE MOISTURE CONTENT ASTM C566-89
- CONRETE UNIT WEIGHT UNIT WEIGHT ASTM C138-92
- CONCRETE VISUAL CHECK ASTM 311.4R-88
CEMENT
- GRAIN FINENESS ASTM C024
- SETTING TIME ASTM C191-77
- SPECIFIC GRAVITY/ ASTM C188-78
TRANSPORTATION
TRANSPORTATION ASTM C94-94
FLY ASH
ADDITIVE
LABORATORY
MAIN
CONTRACTOR
END
PENGENDALIAN MUTU PRODUKSI
III. Pengendalian Mutu Produksi
a. Minimal diambil satu kali pengambilan benda uji untuk setiap mutu dalam satu hari pengecoran atau,
b. Minimal diambil satu kali pengambilan untuk setiap volume, 114 - m3 ( 150 cu yd ) untuk setiap mutu dalam
satu hari pengecoran atau,
c. Minimal satu kali pengambilan untuk pengecoran konstruksi plat atau dinding dengan luas (5000 sq ft)
464.5 m2.
Sesuai hal tersebut diatas maka pengambilan benda uji diatur sebagai berikut :
Untuk Pengecoran precast maka jumlah sample diambil 4 sample dengan rincian
pengetesan adalah :
1 Buah umur 5 hari
1 Buah umur 7 hari
2 Buah umur 28 hari
Pengambilan sample sesuai dengan ASTM C.172
(Practice for sampling Freshly Mixed Concrete)
Pengetesan benda uji sesuai dengan ASTM. C 39 (Test Method for Compresive Strength of Cylindrical
Concrete Specimens)
START
AGGREGATE
FLY ASH CEMENT WATER ADMIXTURE
QUARRY
SELECTION
NO
QUANTITY
TEST
OK
NO
QUALITY
TEST
OK
TRIAL
START
PRODUCTION
BATCHING PLANT
MIX DESIGN
ERECTION
SCALE
NO REPAIRING
YIELD & YES NO
VISUAL CALIBRATION
DEVIATION CHECK
TREND RESULT
MONITOR
OK
FOR
THE
NEXT PRODUCTION
PRODUCT
CONTROL
DELIVERY
SAMPLING
END
EVALUASI PENERIMAAN BETON
IV. Evaluasi Penerimaan Beton
Ketentuan Umum
a. Satu hasil test adalah dari 2 benda uji dalam sample yang sama.
b. Evaluasi berdasarkan 30 atau lebih hasil test (Umur 28 hari) yang dihitung dengan rumus :
f'c = fcr - 1.34 S
c. Untuk hasil test, 15 s/d 29 untuk Deviasi Standar dikalikan Faktor koreksi :
d. Secara khusus kekuatan dari masing2 mutu sesuai dengan yang disyaratkan :
1. Rata-rata dari semua pasangan tiga hasil test berurutan sama atau lebih dari f'c.
2. Tidak ada satupun hasil test (Rata2 dua Cylinder) dibawah f'c.
HASIL TEST SEMEN
SLAG POWDER
HASIL TEST AGREGAT KASAR
CV ARUM ABADI
Plant Tarahan
Jl Bakauheni Raya KM 15
SIEVE ANALYSIS
100
90
80
PASSING PERCENTAGE
70
60
50
40
30
20
10
0
0,1 1 10 100
RUN NO : I II
NO. OF FLASK
A - C 1,237 1,370
4 WATER ABSORPTION -------------------------- x 100 %
C 1,304
REMARKS :
DESCRIPTION &
SOURCE OF SAMPLE Crushed Stone ex Tanjung
RUN NO : I II
REMARKS 0,57%
SIEVE ANALYSIS
100
90
80
PASSING PERCENTAGE
70
60
50
40
30
20
10
0
0,1 1 10 100
RUN NO : I II
NO. OF FLASK
REMARKS :
RUN NO : I II
REMARKS 2,69%
®
Plastiment -V105
Mid-Range Water-Reducing Admixture
Product Plastiment® -V105 is a highly effective liquid Mid Range Water Reducing
Description admixture for the production of medium to high workability concrete
Plastiment® -V105 is chloride free admixture and is compatible with all types
of Portland Cement including Sulphate Resistant Cement (SRC).
Construction
Uses Plastiment® -V105 is suitable for the production of site mixed as well as ready
mixed concrete
Used for concrete with extended transport or placing times
Used for concrete in hot climates where long slump retention is required
Used for concrete using high absorbent sand
Used for concrete using high percentage of quarry dust
Back
Table of Contents
Note:
Typical dose rate is 0.30% -0.50% by weight of cementitious material for
normal absorbent sand e.g. silica sand
For use in high absorbent sand e.g. volcanic sand or in the case of use of
more than 30% of quarry dust (manufactured sand) the typical dose rate is in
the range of 0.45 – 0.90%
For more specific requirements, advice is available from our Technical Service
Department to determine the usage rate for optimum results.
Application Instructions
Dispensing Plastiment® -V105 shall be dispensed with the mixing water into the truck mixer
Do not dilute Plastiment® -V105
Application Method / The standard rules of good concreting practice, concerning production and
Tools placing, are to be followed.
Laboratory trials before concreting on site are strongly recommended when
using a new mix design or producing new concrete components.
Fresh concrete must be cured properly and as early as possible.
Cleaning of Tools Clean all tools and application equipment with water immediately after use.
Hardened / cured material can only be removed mechanically.
Notes of Application / When accidental overdosing occurs, Plastiment® -V105 does not entrain
Limitations excessive amounts of air, however the set retarding effect increases. During
this period the concrete must be kept moist in order to prevent premature
drying out.
Value Base All technical data stated in this Product Data Sheet are based on laboratory
tests.
Actual measured data may vary due to circumstances beyond our control.
Health and Safety For information and advice on the safe handling, storage and disposal of
Information chemical products, users should refer to the most recent Material Safety Data
Sheet (available on request) containing physical, ecological, toxicological and
other safety-related data.
Legal Notes The information, and, in particular, the recommendations relating to the application and end-use of
Sika products, are given in good faith based on Sika’s current knowledge and experience of the
product when properly stored, handled and applied under normal conditions in accordances with
Sika’s recommendations. In practice, the differences in materials, substrates and actual site
conditions are such that no warranty in respect of merchantability or of fitness for a particular
purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from
this information, or from any written recommendations, or from any other advice offered. The user of
the product must test the product’s suitability for the intended application and purpose. Sika reserves
the right to change the properties of its products. The proprietary rights of third parties must be
observed. All orders are accepted subject to our current terms of sale and delivery. Users must
always refer to the most recent issue of the local Product Data Sheet for the product concerned,
copies of which will be supplied on request.
Branches
PT. Sika Indonesia Surabaya :
Jl. Raya Cibinong- Bekasi km. 20 Puri Niaga Blok G No. 29, Jl. Raya Rungkut Menanggal 11, Surabaya
Tel : 031-8690202 ; Fax : 031-8682123
Limusnunggal- Cileungsi Medan :
BOGOR 16820 - Indonesia Kawasan Industrial " Medan Star ", Tanjung Morawa Km.19,2
Jl. Pelita Raya Blok R No.32, Deli Serdang 20362
Tel. +62 21 8230025 Tel : 061-7941200 ; Fax : 061-7940822
Fax +62 21 8230025 Batam :
Website : www.sika.co. id Jl. Laksamana Bintan,Komp. Bumi Riau Makmur Blok E No.3,
Sungai Panas, Batam
e-mail: sikacare@id.sika.com Tel : 0778-424928 ; Fax : 0778-450189
Sikament LN
®
Description A highly effective water reducing agent and superplasticizer for promoting
accelerated hardening with high workability.
Complies with A.S.T.M. C 494-92 Type F
Construction
Dispensing Sikament LN can be added to the gauging water prior to its addition to the dry
aggregates or separately to the freshly mixed concrete (on the batching plant or
on site into the truck mixer) where added to truck mixer on site, further mixing for
three to five minutes should be carried out.
Pre-trials are recommended if combinations with the above products are required.
Please consult our Technical Service Department.
Technical Data
Type Modified Naphthalene Formaldehyde Sulfonate
Colour Dark brown
Specific Gravity 1.18 – 1.20 kg/ ltr
Shelf life 1 year in unopened original container
Storage Dry, cool, shaded place
Packaging 240 kg drum
Bulk delivery
Back
Table of Contents
1 Sikament® LN 1/2
Handling
Precautions: Avoid contact with skin and eyes
Wear protective gloves and eye protection during work
If skin contact occurs, wash skin thoroughly.
If in eyes, hold eyes open, flood with warm water and seek medical attention
without delay.
Legal Notes The information, and, in particular, the recommendations relating to the application and end-use of Sika
products, are given in good faith based on Sika’s current knowledge and experience of the product when
properly stored, handled and applied under normal conditions in accordances with Sika’s
recommendations. In practice, the differences in materials, substrates and actual site conditions are such
that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising
out of any legal relationship whatsoever, can be inferred either from this information, or from any written
recommendations, or from any other advice offered. The user of the product must test the product’s
suitability for the intended application and purpose. Sika reserves the right to change the properties of its
products. The proprietary rights of third parties must be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always refer to the most recent issue of the local Product
Data Sheet for the product concerned, copies of which will be supplied on request.
Construction
Branches
PT. Sika Indonesia Surabaya :
Jl. Raya Cibinong- Bekasi km. 20 Puri Niaga Blok G No. 29, Jl. Raya Rungkut Menanggal 11, Surabaya
Tel : 031-8690202 ; Fax : 031-8682123
Limusnunggal- Cileungsi Medan :
BOGOR 16820 - Indonesia Kawasan Industrial " Medan Star ", Tanjung Morawa Km.19,2
Jl. Pelita Raya Blok R No.32, Deli Serdang 20362
Tel. +62 21 8230025 Tel : 061-7941200 ; Fax : 061-7940822
Fax +62 21 8230025 Batam :
Website : www.sika.co. id Jl. Laksamana Bintan,Komp. Bumi Riau Makmur Blok E No.3,
Sungai Panas, Batam
e-mail: sikacare@id.sika.com Tel : 0778-424928 ; Fax : 0778-450189
2 Sikament® LN 2/2
HASIL TEST AIR
LAMPIRAN
DAFTAR REFERENSI